High pressure reactors Where are your limits?



Similar documents
Autoclave Engineers. Laboratory Stirred Reactors. Stirred Reactors

globe reactions made easy Process perfection

Multiple flasks. Easy to adapt. Stuart range of heating blocks

Self-operated Temperature Regulators Temperature Regulator Type 1u

Bypass level indicator With magnetic display Model BNA

Vacuum drying oven for non-flammable solvents

ORGANIC SAMPLE PREPARATION


Compact pressure switch Flameproof enclosure Ex d Model PCA

Mitos P-Pump. product datasheet

18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

Screw Plug Immersion Heaters

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Mechanical shaft seal types and sealing systems

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Variable V Area Flowmeter Rotameter The Original

Handling Corrosive or Abrasive Liquids

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

MILESTONE. SynthWAVE. The Game Changer in Microwave Synthesis

Homogenizer with Direct Controller. Digital Homogenizer with Remote Controller. Homogenizing Stirrer, for use with Tissue Grinders.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

kymanual or Automatic - it s your Choice

Our convenient autoclave, right on the laboratory bench.«

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

API Flanged Safety Relief Valves Series 526 CATALOG

AUTOCLAVE CORROSION INHIBITOR EVALUATION

API Marine. BMS Presentation. Ballast Measurement Systems

Steam System Best Practices Condensate System Piping

NLK apparatus EN ( )

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Determination of the enthalpy of combustion using a bomb calorimeter TEC

Electronic Flow Switches

High Pressure Equipment Pressure Vessels and Reactors Index

AIR LINE VALVES AND GAUGES

Full Technical Catalog For Closed-loop Sampling System

BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES

Digital Hotplate. Stirrers. Compact & Round Plate Type Hotplate Stirrers. Analog Hotplate Stirrer. Digital Hotplate

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

MINEX -S. Magnetic coupling. You will find continuously updated data in our online catalogue at

Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

CHEMICAL CLEANING UNIT Product number:

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions

Water Baths. with BioCote antimicrobial protection

Typical Aluminum GFM Mass Flow Meter

SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration

Portable digital microprocessor thermometers with interchangeable probes

Backflush filter R8-30W

Seamless stainless tubes for hydraulic and instrumentation systems

for ALL your Rupture Disk needs...

TELESCOPE Motorized Lighting Suspension

Specials. designed. 3rd edition 2015 English. for scientists 1

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

LABOKLAV. Autoclaves Made in Germany.

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

Kompressoren. Adsorption Dryer AD

RET control-visc. The Magnetic Stirrer for Scientists. designed. Phil S. Baran Ph.D. Baran uses IKA equipment. to work perfectly

Laboratory- and sterilisation equipment HMC EUROPE

Drain Back systems Made in Germany

The Safest Heating Method!

ISO/VDMA Actuators. Engineering GREAT Solutions

FAG Induction Heating Devices HEATER. Quality and Safety Redefined


Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Ultrasonic cleaning technology and cleaning chemicals

14 Friedel-Crafts Alkylation

ABEL EM. Electromechanical. Membrane Pumps. The economical alternative. From the reciprocating positive displacement pump specialist

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

Check Valves & Actuated Valves

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

FVA/A1 saturated-steam sterilizer

Cables. Accessories. For Force, Torque and Strain Sensors

Washing. Sterilising. Filling. Closing. Inspecting. Labelling

Overview of the. measurement and control technology range

Best Practice in Boiler Water Treatment

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

MILESTONE START D. Microwave Digestion System

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.

BSL3 and BSL4 Autoclaves. Laboratory Line

Plastic lining by Roschütz

Laboratory Control Software

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

Digital inductive conductivity transmitter

Spetec. Laminar Flow Box. Portable Clean Room Technology

WATERPROOFING OF WET ROOMS

Pipe Cutting and Beveling Clamshells

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Rotary screw compressors kw 5,5 7, , bar MODULO

Transcription:

Laboratory equipment High pressure reactors Where are your limits?

Modern high pressure reactors need to be technically safe, reliable, economical in use and simple to operate. With Berghof quality and safety are an integral part of the design concept. High-quality materials combined with durable PTFE lining and modular configuration options are the decisive plus points for the user. 01

Convenience The high pressure reactors are opened and closed quickly, easily, without tools and with just a couple of hand movements by means of a clamping ring or chain. The fittings are designed to be dead volume-free so that cross-piece and T-pieces are not needed. The risk of contamination is significantly reduced. The high pressure reactors are easy to handle and maintain. All connections can be conveniently removed and remounted by the user for service and cleaning work. Safety Berghof high pressure reactors are designed, built and tested in compliance with 97/23/EC European equipment guideline and in accordance with the German AD- 2000 set of regulations. As independent assessor the TÜV checks the construction and conducts the pressure test where this is prescribed for a CE marking. Each Berghof high pressure reactor is hydrostatically pressure-tested with mandatory overpressure and submitted to a leakage test. Once the test has been passed, and prior delivery, a Berghof high pressure reactor receives an appropriate inspection certificate documenting faultless functioning. Flexibility As regards the very variable configuration of the high pressure reactors customers have a choice. In addition to the extensive selection of standard fittings, optional features such as sample feeds and sample taking under operating pressure are also available. As a result of the modular concept these can be complemented at any time by additional fittings. All components can be supplied in stainless steel or Hastelloy. Modularity The modular concept offers a cost-efficient solution since the reactor lid can be combined with various reactor vessels and inserts so that the capacity of the reactor can be optimally adapted. In addition all inserts can be used as practical storage vessels for reaction solutions. The range of products includes low-capacity high pressure reactors of 25 ml right through to reactors with the pilot plant scale of 5.5 L. Material concept With the integrated material concept of Berghof high pressure reactors the most suitable material can very easily be found for all reaction media. The high pressure reactors and fittings can be supplied in stainless steel or Hastelloy. Such high pressure reactors are particularly suited to organic solvents. The distinctive feature of Berghof reactors is the complete PTFE lining of the reactor vessels and lids. Being several millimetres thick, the robust walls of the inserts and linings offer the most effective protection for all components that come into contact with corrosive materials such as acids and bases. The high quality of the materials used and the precision of the finish result in Berghof high pressure reactors having an above-average service life. Sealing concept Easy handling combined with unsurpassed safety form the basis for the sealing concept of Berghof high pressure reactors. Sealing is effected reliably with a conical flange lock and an O-ring made of PTFE or other materials, thus guaranteeing hermetic sealing of the reactors. 01 Berghof high pressure reactors are easy to handle.

Highpreactor Features Stirring Standard fittings Pressure measurement Special fittings Temperature regulation Reactor lid Closure Reactor vessel Sealing concept Reactor lid PTFE lid lining PTFE O-ring Reactor vessel PTFE insert 01 02 03

Berghof high pressure reactors offer considerable scope for customers individual configuration of the reactor systems. An extensive range of accessories makes laboratory work easier. Reactor lid and vessel Stirring Pressure measurement The high pressure reactors are constructed of stainless steel or Hastelloy. The thickwalled PTFE lining of the reactor lid provides effective protection against corrosion. To protect instruments from corrosion in the gas phase where strong mineral acids or aggressive gases are applied the use of fittings made of Hastelloy is recommended. For optimal corrosion protection of the reactor vessels stable PTFE inserts of various capacities are available. Closure Berghof high pressure reactors offer unsurpassed ease of use. They are opened and closed quickly, easily and without tools with just a couple of hand movements by means of a clamping ring or chain. Seals Conical flange locks with O-rings are used to seal the reactors. The materials used for the O-rings have various application-specific characteristics. PTFE exhibits an unsurpassed resistance to nearly all chemicals and permits application temperatures up to 230 C. FPM (e.g. Viton ) or FFKM (such as Kalrez ) are true elastomers suitable for application temperatures up to 230 C or 300 C. The choice ranges from reasonably priced magnetic stirring bars for low-capacity high pressure reactors up to magnetic coupling with various drives and torque levels. A variety of paddle shapes permit effective adaptation to the media being stirred. The magnetic couplings of stainless steel or Hastelloy can be supplied with PTFE, stainless steel or Hastelloy stirrers. Stirring force is transferred via a removable magnetic coupling in the reactor lid which is mechanically coupled to an external stirrer motor. Standard fittings All standard fittings can be supplied in stainless steel or Hastelloy. A standard fitting consists of a gas valve to vent the reactor and a rupture disc to provide protection against excess pressure. The over-pressure valves are equipped with a coupling for pressure lines to carry off released gases and vapours harmlessly. Options All fittings have easily accessible screw-on clamping rings, making Berghof high pressure reactors extremely service and maintenance friendly. Available fittings include systems for gas or liquid sampling as well as liquid injection under operating pressure. Test reactors can be additionally equipped with cameras and interior lighting for material testing. Either a manometer or an electric pressure sensor is factory-installed for pressure measurement. Pressure transducer made of either stainless steel or Hastelloy can be installed to protect the pressure measuring system against aggressive media. The pressure transducer transfers the reactor pressure to the sensor or manometer without it having to come into contact with the aggressive medium. Temperature regulation The internal temperature of the high pressure reactor is continuously measured with the aid of a temperature probe which is inserted in a dip tube made of stainless steel or Hastelloy and which can be protected with PFA lining. Heating control can be effected with a freely programmable PID temperature regulator. To protect against overheating of the reactor a second independent temperature probe can be built in to provide excess temperature protection. Accessories For optimal regulation and control of the reaction parameters, heaters, temperature regulators, stirrers, stand systems, data loggers and much more round off the portfolio. 01 Sealing concept of Berghof high pressure reactors 02 Individually configurable reactors for maximum flexibility 03 Easy-to-use clamping rings and chains for secure closure

Among the Berghof strengths are the knowledge and skills involved in handling of PTFE. With this know-how Berghof provides its customers with solutions, even where highly corrosive media are being used.

Reactor capacities Overview of Highpreactor capacities (with PTFE insert) BR-25 BR-100 BR-300 BR-1000 BR-4000 25 ml (25 ml) 170 ml (50 ml) (75 ml) (100 ml) (150 ml) 350 ml (300 ml) 1,100 ml (1,000 ml) 5,500 ml (4,700 ml) 40 ml (40 ml) 230 ml (200 ml) 600 ml (500 ml) 1,700 ml (1,500 ml) 900 ml (700 ml) 2,300 ml (2,000 ml) 5,500 4,700 [ml] 2,000 1,500 1,000 700 500 300 200 150 100 75 40 25 BR-25 BR-100 BR-300 BR-1000 BR-4000 PTFE lining Berghof reactors are completely lined with PTFE to provide corrosion protection. For this a stable PTFE insert is placed in the reactor vessel. The reactor lid is, moreover, lined with an additional several mm thick layer of PTFE, while the immersion tubes are encased with PTFE. The stirrer, too, can be completely manufactured from PTFE. Thus all parts of the reactor that come into contact with the media are effectively protected from aggressive reagents. Reactor capacities Every series of reactors (BR-25, BR-100, BR-300, BR-1000 and BR-4000) can be supplied with various capacity modules. Here, fine tuning is achieved by the thickness of the PTFE insert, making it possible to combine the reactor lid with various reactor vessels and inserts. Benefits The PTFE inserts can also be used as practical storage receptacles for reaction solutions so that the risk of cross-contamination or catalyst poisoning is minimised. Areas of application BR-25: The Small One from Berghof is ideal for very small tests with expensive raw materials or those that involve complex manufacturing processes. BR-100: The Handy One from Berghof is the standard reactor for everyday laboratory use. BR-300: The Universal One from Berghof is of particular interest due to its diverse stirring and heating technology. BR-1000: The Big One from Berghof is ideal for more extensive testing. BR-4000: The Strong One from Berghof is just the right unit for pilot plant tests.

Highpreactor Technical specifications Reaction control Temperature regulation is achieved with a temperature probe in a dip tube which registers the internal temperature of the reactor. The easy-to-use temperature controller combines all control and regulation parameters in one compact unit. All process parameters are easily accessible. The built-in data logger allows the parameter to be documented on a PC. Highpreactor Highpreactor Reactor capacity 25 ml - 5.5 L Torque value max. 100 Ncm Materials Max. operating temperature Max. operating pressure Standard fittings Options SS316TI, Hastelloy C-4, optionally with PTFE lid lining and PTFE liners PTFE: 230 C (446 F), SS316TI: 300 C (572 F) 200 bar (2,900 psi) Rupture disc holder, Rupture disc, gas valve gas or liquid sampling and liquid injections at operating pressure, heating/cooling coil Heatings Temperature controller Data logger Special solutions Heating block Electric heating jacket Thermostatic jacket BTC-1000 BTC-3000 BDL-3000 Bottom drain valve EX-protection Seals FPM (e.g. Viton ), PTFE, FFKM (e.g. Kalrez ) Connetcions 8 mm Stirring Magnetic stirring, magnetic coupling and different paddle shapes Stirring speed 0-2,000 rpm Berghof Products + Instruments GmbH Eningen Site Harretstrasse 1 72800 Eningen Germany T +49.7121.894-0 F +49.7121.894-300 laboratorytechnology@berghof.com www.berghof.com 53-129-85-01-01-001, All rights reserved; subject to changes and errors, Printed in Germany