NLK apparatus EN ( )
|
|
|
- Hilary Thomas
- 9 years ago
- Views:
Transcription
1 Germany Karlsruhe Gablonzer Straße 6 Tel / 721 / Fax / 721 / [email protected] Internet: NLK apparatus EN ( )
2 1. Unpacking and Installation Please carefully unpack the apparatus and check for any damages. It is important to immediately detect potential damages caused by transportation. In this case a direct recording of facts is necessarily. Therefore please contact the manufacturer. Observe technical data for information concerning permissible surrounding conditions. Before starting-up, please check your power supply: 230 V - 50 Hz or 115 V - 60 Hz. Only licensed temperature probes can be used. 2. Installation and Start-up Please observe the following succession when installing the apparatus. ATTENTION - SECURITY ADVICE Unslaked lime is etching. The milk of lime is highly alkaline after slaking.!! Implicitly wear safety glasses and protective gloves!! 1. Set up the rack and mount cross clamp and Dewar clamp. 2. Mount cross clamp for stirrer motor on the rack and fix stirrer motor. 3. Insert blade stirrer into the stirrer chuck and secure it. 4. Put Dewar flask on rack board and fasten it with the Dewar clamp. 5. Adjust stirrer motor and blade stirrer roughly to the Dewar flask. 6. Tune stirrer motor on the lowest speed and align Dewar flaks with stirrer motor accurately, so that the blade stirrer can rotate freely in the Dewar flask. 7. Put on the lid and align stirrer motor with blade stirrer again so that the blade stirrer can rotate freely. The blade stirrer must not touch the glass and the Dewar must be secured by means of Dewar clamp. 8. Attention: check immersion depth of blade stirrer. 9. Close the lid. Insert temperature sensor and secure it. 10. Connect temperature sensor and observe operating instructions of the temperature measuring device.
3 3. General Information Reactivity examination of fine lime while slaking effects via measuring the incipient rise of temperature subject to the duration of reaction (wet slaking curve, NLK). Basis of apparatus and measuring system is EN Test procedures and measuring methods see Building lime - part 2: Procedure EN Products according to EN (Extract of standard ponit 6.6.2) The apparatus shall consist of the six parts shown in Figure 1) Dewar vessel type F9C, Vol ml, internal diameter about 77 mm, internal height about 235mm. 2) Stirrer motor, (300 10) min-1 under load. 3) Stand rack and support. 4) Blade stirrer made of suitable plastics, see drawing. 5) Plastics lid with segment which can be opened, feed opening and bore for the temperature sensor, to fit the Dewar vessel. 6) Calibrated thermometer (or comparable electric temperature measuring instrument) 0 C to 100 C with an accuracy of 0,5 C and a high rate of response (adjustment time from 20 C to 60 C less than 10 s). The penetration depth shall be about 160 mm from a suitable hole on the top edge of the lid. Option: - The following shall be used additionally: a recorder for the temperature measurement. - weighing and feeding device, made of stainless steel
4 Stirrer motor Nr. 2 Thermometer Nr. 6 Lid with segment Nr. 5 Dewar vessel F9C Nr. 1 Blade stirrer NLK Nr. 4 Stand and support Nr. 3
5 3.2. Determination of the water equivalent of the apparatus (extract of standard point 6.6.3) Determine the water equivalent w by measuring the mixing temperature T of an amount of m approximately 650 g in the Dewar vessel. Use the apparatus under the same conditions as for a reactivity test. Fill (450 ± 1) g of water (m c) of a temperature of (20 ± 0,1) C (T c) into the Dewar vessel. Then add (200 ± 1) g of water (m h) of a temperature of (50 ± 0,1) C (T h). Run the stirrer at (300 ± 10) min -1. Measure the temperature T m to ± 0,1 C after (5 ± 0,1) min. w = m h (T h - T m) - m c (T m T c) x 4,19 Joule / Kelvin T m Tc where T m w m,h,c h,c are temperatures, in degrees Celsius; are masses, in grams; is the water equivalent value, in joules per kelvin. Alternative For determination of water equivalent, as well as the entire computation and the automatic operational sequence for the reactivity of the sample (e.g. lime) we recommend the software PDV-NLK3 of the company PDV-Software GmbH to you. Please have a look at there homepage
6 NLK assembly with stand rack Type A for wired sensor Order No.: Scope of delivery without data logging and stirrer motor with its clamp. IKA stirrer motor No.: 1229RW20 Cross clamp No.: Temperature measuring device with wired sensor No.: and Lid with segment No.:11217 Dewar vessel F9C No.:1126 Dewar clamp No.:11223 Cross clamp No.: NLK blade stirrer No.:11219 V2A stand rack No.: 11221
7 NLK assembly with stand rack Type AL for wireless sensor Order No.: 11218L Scope of delivery without data logging and stirrer motor with its clamp. Stirrer motor / No.: 11229RW20 Cross clamp / No.: Temperature measuring device with wireless sensor No.: 11225L and 11228L Lid / No.:11217 Dewar F9C / No.:1126 Dewar clamp / No.:11223 Cross clamp / No.: Blade strirrer NLK / No.:11219L V2A stand rack / No.:11221
8 Order Numbers Type A No.: Order No.:11222 Order No.:11229 Order No.:11228 Order No.:11219 Order No.:11217 Order No.:11223 Order No.:1126 Order No.:11221 Order No.:11225
9 NLK assembly with telescope frame Type B for wired sensor Order No.: Scope of delivery without data logging and stirrer motor with its clamp. IKA stirrer motor No.: 1229RW20 Cross clamp / No.: 11222T Temperature measuring device with wired sensor No.: and Lid with segment / No.:11217 Dewar vessel F9C / No.:1126 Dewar clamp / No.:11223 Cross clamp / No.: 11222T NLK blade stirrer / No.:11219 Telescope frame No.: 11221IKA
10 Order numbers Type B No.: Order No.: 11229RW20 Order No.:11222T Order No.:11221IKA Order No.:11228 Order No.:11217 Order No.:11219 Order. No.:11222T Order No.:11223 Order No.:1126 Order No.:11221IKA Order No.:11225
11 NLK assembly with stand rack Type BL for wireless sensor Order No.: 11235L Scope of delivery without data logging and stirrer motor with its clamp. Stirrer motor No.: 11229RW20 Cross clamp No.: 11222T Temperature measuring device with wireless sensor No.: 11225L and 11228L Lid / No.:11217 Dewar F9C No.:1126 Dewar clamp No.:11223 Cross clamp No.: 11222T Blade strirrer NLK No.:11219L Teleskop frame No.: 11221IKA
12 NLK Assembly with stationary frame type C 3 and three measuring stations NLK Assembly with stationary frame type C3 for one wired sensor and two wireless sensors with data logging, Dewar flasks, lids, long blade stirrers, Dewar clamps, stirring motors. Appropriate evaluation software when required, is sold by PDV. One wired sensor is always required on assemblies with multiple measuring stations, if using one or more wireless sensors. Up to three wireless sensors can get applied, afterwards. The data logger itself additionally needs an embedded radio module. In addition, long version of blade stirrer is needed, when using wireless sensors.
13 NLK Assembly with stationary frame type C for wired and wireless sensors, up to four measuring stations. Part no C2, consisting of: A frame with two Dewar flasks, two lids, two long blade stirrers, two cross clamps and two Dewar clamps (data logging and stirrer motors with their clamps are not included in scope of delivery). Part no C3, consisting of: A frame with three Dewar flasks, three lids, three long blade stirrers, three cross clamps and three Dewar clamps (data logging and stirrer motors with their clamps are not included in scope of delivery). Part no C4, consisting of: A frame with four Dewar flasks, four lids, four long blade stirrers, four cross clamps and four Dewar clamps (data logging and stirrer motors with their clamps are not included in scope of delivery).
14 Accessories and spare parts Cross clamp No.: or 11222T Weighing and feeding device No: Dewar clamp No.: Dewar flask NLK Typ F9-C No.: 1126 Blade stirrer No: for wired sensor Blade stirrer No: 11219L for wireless sensor Lid with segment No: 11217
15 Accessories and spare parts Temperature measuring device for one wired sensor. Part no.: Temperature measuring device with radio module for one wired sensor and up to three wireless sensors. Part no.: 11225L. Power supply for temperature measuring device. Part no.: 11225N Power supply cannot be used, if PDV software is utilised. Temperature sensor Typ K wireless No.: 11228L Temperature sensor Pt100 wired No.: Temp.C 75,00 Comparative measurement 70,00 65,00 60,00 55,00 50,00 45,00 40,00 1. Measurement temperature sensor wireless 1. Measurement temperature sensor wired 35,00 30,00 25,00 20,00 15,00 0 Seconds
16 Accessories and spare parts Stand rack type C for 3 NLK assemblies. Measuring instruments holder 1000 B 400 Stand rack for two NLK systems, width B= 600mm, Stand rack for three NLK systems, width B= 900mm, Stand rack for four NLK systems, width B= 1200mm, Art. No.: 11221C2 Art. No.: 11221C3 Art. No.: 11221C4
17 Article Part no. Complete assemblies NLK Assembly type A for wired sensor Complete assembly with STAND RACK (without temperature-measuring device, stirrer motor/clamp and feeding device as per standard ) NLK Assembly type AL for wireless sensor Complete assembly with STAND RACK (without temperature-measuring device, stirrer motor/clamp and feeding device as per standard ) 11218L NLK Assembly type B for wired sensor Complete assembly with TELESCOPE FRAME (without temperature-measuring device, stirrer motor/clamp and feeding device as per standard ) NLK Assembly type BL for wireless sensor Complete assembly with TELESCOPE FRAME (without temperature-measuring device, stirrer motor/clamp and feeding device as per standard ) 11235L NLK Assembly type C for a wired sensor and wireless sensor(s) Complete assemblies with special STAND RACK (without temperature-measuring device, stirrer motor/clamp and feeding device as per standard ) W ith 2 x Dewar vessels, Lids and Blade stirres 11219L W ith 3 x Dewar vessels, Lids and Blade stirres 11219L W ith 4 x Dewar vessels, Lids and Blade stirres 11219L 11218C C C4 Accessories 1. Temperature-measuring device from TESTO Testo-Datalogger Testo-Datalogger with radio module 11225L Power supply unit 11225N Temperature sensor - wired Temperature sensor - wireless 11228L 2. Stirrer motors from IKA RW 20 digital (plus clamping, e.g. cross clamp R270) 11229RW 20 Eurostar 40 digital (plus clamping, e.g. cross clamp R270) Cross clamp R270 for assemblies type B, BL or C W eighing and feeding device as per standard Spare parts Special Dewar vessel F9C / NLK 1126 Glass refill for special Dewar, F9A / NLK 1116 Plasitic lid with segment Blade stirrer for wired sensor Blade stirrer for wireless sensor 11219L Cross clamp for stand rack (16mm) Cross clamp for telescope frame (30mm) 11222T Dewar clamp up to D=170mm Stand rack Telescope frame 11221IKA Stand rack type C2 without accessories (for 2 NLK-assemblies) Stand rack type C3 without accessories (for 3 NLK-assemblies) Stand rack type C4 without accessories (for 4 NLK-assemblies) For NLK-software: please contact the company PDV directly (KGW does not sell this software) 11221C C C4
18 Software solution for capturing and supporting the analysis process The company pdv-software GmbH, Goslar (Germany) has developed pdv-nlk 3 for capturing, storing, and the mathematical analysis of the measured values?. Measurement data acquisition with pdv-nlk 3 Key Features Measurement data acquisition with two temperature sensors/transducers Analysis according to DIN EN Parameters T0, tmax, Tmax, T'max, tu80, Tu80, T60, T10, T40, R-value, maximum of turnover rate Records values up to four temperature sensors/transducers Representation of the characteristic values in the wet slaking curve diagram Saving (as an image file) and printing of measurement progress Management of measurement data and samples Central master data Integrated device driver for measurement instrument Testo 735, up to 4 channels simultaneously; other drivers on request Calibration of the sensors on two or more points Examination of heat loss of the Dewar vessels Import and Export of existing raw and end data via CSV interface Integration with laboratory information systems (LIS/LIMS) possible Detailed information about this solution can be found online at If you are interested in pdv-nlk 3 please consult directly: pdv-software GmbH [email protected]
Specials. www.ika-apparatuur.nl. designed. 3rd edition 2015 English. for scientists 1
Specials www.ika-apparatuur.nl 3rd edition 2015 English designed for scientists 1 IKA Specials Quarterly Campaign III Three is a charm With over 100 years of experience, IKA continues to strive for delivering
High pressure reactors Where are your limits?
Laboratory equipment High pressure reactors Where are your limits? Modern high pressure reactors need to be technically safe, reliable, economical in use and simple to operate. With Berghof quality and
ATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers
Magnetic Stirrers Patented RET control-visc with white coated heating plate! > Offers excellent chemical resistance > Easy to clean RET controlvisc kg Integrated temperature sensor for precise temperature
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Test equipment for temperature and its reduction
Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Compact ph Measuring Instruments
testo 205, 206, 230 Compact ph Measuring Instruments With innovative probe engineering ph C The new ph measuring instruments with innovative probe engineering Measurement of the ph value plays an important
804 Ti Stand. Manual 8.804.8001EN
804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
Introductory Laboratory EST - Experiment 9 Calorimetry - 1 - Introductory Laboratory Energy Science and Technology. Experiment 9. Physical Chemistry
Introductory Laboratory EST - Experiment 9 Calorimetry - 1 - Introductory Laboratory Energy Science and Technology Experiment 9 Physical Chemistry Calorimetry Abstract The heat of combustion of Naphthalene
Multiple flasks. Easy to adapt. Stuart range of heating blocks
Heating Blocks The Stuart range of heating blocks have been developed in conjunction with DrySyn to provide the best possible solution for heating round bottom flasks. Combined with the Stuart range of
Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid
Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid Introduction Many metals react with acids to form hydrogen gas. In this experiment, you will use the reactions
Highly efficient flue gas analyzer
Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement
Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC
HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586:
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
BLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
Shaking Water Baths THERMOLAB
Shaking Water Baths THERMOLAB "Precision in series" - a synonym for a specialised range of four Shaking Water Baths that are in use all over the world Quality built on Tradition Users in research labs,
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
heat treatment equipment & accessories
heat treatment equipment & accessories Dear Customer, ElectroHeat Sweden AB is an innovative company based in Gothenburg, and has been operating since 1975. We manufacture industrial furnaces and heat
Stainless steel process fittings
Page 1/6 Stainless steel process fittings Installation in pipe systems Installation in tanks and vessels Hygienic version FDA conformity of materials Probe length 120 mm 120 mm Availability of various
STAR Linear Bushings and Shafts Supplement RE 83 117/2001-08. Linear Motion and Assembly Technologies
STAR Linear Bushings and Shafts Supplement RE 83 117/2001-08 Linear Motion and Assembly Technologies STAR Linear Motion Technology Ball Rail Systems Standard Ball Rail Systems Ball Rail Systems with Aluminum
Dissolved Oxygen Sensors
Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit
Evaluation copy. Energy Content of Foods. computer OBJECTIVES MATERIALS
Energy Content of Foods Computer 10 Energy content is an important property of food. The energy your body needs for running, talking, and thinking comes from the food you eat. Energy content is the amount
Rittal TopTherm fan-and-filter unit
Rittal TopTherm fan-and-filter unit System Climate Control More pressure. Higher air flow rates. 2 Assembly without tools Straightforward assembly, exchange and maintenance with no need for tools of any
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
The volume of a penny will be calculated from its mass and density.
Measurement and Density In science a key concern is the quantities involved in chemical processes. These amounts can be directly measured or calculated from other measurements. A measurement consists of
Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.
Conductivity of strong and weak electrolytes TEC Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law. Principle It is possible to
MINIMAT-EC-Servo Screwdriver Spindles
Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range
Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions
Safety precautions Naphthalene is harmful if swallowed. May cause cancer. Is further very toxic to aquatic organisms and can have long-term harmful effects in bodies of water. Equipment 1 Bomb calorimeter
TECHNICAL INFORMATION
TECHNICAL INFORMATION Models No. 2012NB Description 304mm (12") Automatic Thickness Planer CONCEPTION AND MAIN APPLICATIONS * Compact and light weight (27 Kg./59 lbs) automatic thickness planer for easier
VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance
VTS³ and VCS³ Stress Screening Systems More Power for Maximum Quality Assurance Tailor-made for your product: Our proven testing methods Thermal and climatic conditions can affect the production, storage
QUANTIFYING SOLAR ENERGY
www.sustainicum.at QUANTIFYING SOLAR ENERGY Recommendations for implementation in the course Author: E-Mail address: Institution: Philipp Weihs [email protected] BOKU Important considerations Very
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
Clifton Food Range Bath Choice Booklet
Clifton Food Range Bath Choice Booklet Choosing the right equipment for you. - Nickel-Electro Ltd 2012. All rights reserved. Nickel-Electro Ltd., Oldmixon Crescent, Weston-s-Mare, North Somerset, BS24
IKA EUROSTAR 20 digital IKA EUROSTAR 40 digital IKA EUROSTAR 60 digital IKA EUROSTAR 100 digital IKA EUROSTAR 20 high speed digital
20000003928 EUROSTAR_092014 IKA EUROSTAR 20 IKA EUROSTAR 40 IKA EUROSTAR 60 IKA EUROSTAR 100 IKA EUROSTAR 20 high speed Operating instructions EN Reg.-No. 4343-01 2 Fig. 3 1 2 3 4 Fig. 2 Fig. 4 Fig. 8
S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS. Final text for addition to The International Pharmacopoeia
March 2012 S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS Final text for addition to The International Pharmacopoeia This monograph was adopted at the Forty-sixth WHO Expert Committee on Specifications
Determination of the enthalpy of combustion using a bomb calorimeter TEC
Determination of the enthalpy of TEC Related concepts First law of thermodynamics, Hess s law of constant heat summation, enthalpy of combustion, enthalpy of formation, heat capacity. Principle The bomb
Hand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
Measurement data monitoring system
We measure it. Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording C Stationary and mobile data monitoring in one system Flexible system set-up with
Instruction Manual Temp 4/5/6 Temperature Meter Series
Instruction Manual Temp 4/5/6 Temperature Meter Series 68X243607 Technology Made Easy... Rev. 2 01/03-1 - Preface This instruction manual serves to explain the use of the Temp 4/5/6 temperature meter.
Portable digital microprocessor thermometers with interchangeable probes
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
Committing to the future. Everything under control: With testo Saveris TM, measurement data are under control everywhere.
Committing to the future Everything under control: With testo Saveris TM, measurement data are under control everywhere. Unlimited data monitoring. Whether stationary or mobile. The data monitoring system
RET control-visc. The Magnetic Stirrer for Scientists. designed. Phil S. Baran Ph.D. Baran uses IKA equipment. to work perfectly
RET control-visc The Magnetic Stirrer for Scientists Phil S. Baran Ph.D. Recipient of MacArthur Genius Grant Baran uses IKA equipment designed to work perfectly RET control-visc Safety. Power. Intelligence.
EasyTrack 2 Accessories List
EasyTrack 2 Accessories List DATA LOGGER ET6061 EasyTrack2 Data Logger (6 Channel) Measurement Range -150 to 500 C (-238 F to 932 F) Accuracy ±0.5 C (0.9 F). Type K thermocouple. 6000 readings per channel.
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Part of Thermo Fisher Scientific Thermo Scientific Varioklav Laboratory
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
SCHMIDT ManualPress 300 Series Manual Presses with Process Monitoring
Manual Presses with Process Monitoring Process reliability, force/stroke monitoring of the joining process and EN ISO- compatible documentation of the results are becoming the major factors for small and
EJOT Spiralform. The thread formers for metal. EJOT The Quality Connection
EJOT Spiralform The thread formers for metal EJOT The Quality Connection Imprint Editor: EJOT GmbH & Co. KG Industrial Fasteners Division D 57319 Bad Berleburg Layout and Realisation: EJOT GmbH & Co. KG
VDL 53 - Vacuum drying oven for flammable solvents
Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed
MInIMAT-ec. flexible data recording highly accurate
Screwdriving technology Automation Air motors Air tools Handheld Screwdriver electric MInIMAT-ec straight handle design - torque ranges between 0.03-18 nm pistol-grip design - torque ranges between 0.06-18
Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P2.6.3.2. Thermodynamic cycle Heat pump
Heat Thermodynamic cycle Heat pump LD Physics Leaflets P2.6.3.2 Investigating the function of the expansion valve of the heat pump Objects of the experiment g To study the operational components of the
Temperature Calibration; Depths of Immersion
Temperature Calibration; epths of Immersion Author: John P. Tavener Company Isothermal Technology Limited, Pine Grove, Southport, England Abstract Of all the sources of errors and uncertainties in thermal
MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances
Operating Instructions MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances 15043 1/1.00 10 9 8 1 7 6 1 Display 2 Slider switch cd/m² segment test 3 ON/OFF switch 4
globe reactions made easy Process perfection
globe reactions made easy Process perfection Benefits More reactions in less time: The Globe oil drain unit and quick clamp allow single hand vessel changes in seconds Space saving: 50ml, 100ml, 250ml,
DENSITY MEASURING SYSTEMS
SHIBAYAMA SCIENTIFIC CO., LTD. DENSITY MEASURING SYSTEMS Density Gradient Tube Method Direct Reading Type A / Type B Comply with the standards below: JIS K-0061-1992, K-7112 1980 ASTM D1505 Type A /Left
Laboratory Control Software
AVA Lab Control Software V1_Layout 1 10/12/2014 15:33 Page 1 Laboratory Control Software Smart automation, tracking and control From a single stirring hotplate to a multi-device jacketed reaction system
MaraMeter. Indicating Snap Gages
- 9-2 MaraMeter. Indicating Snap Gages Overview MaraMeter. The Indicating Snap Gage is ideal for highly accurate and reliable results on cylindrical work pieces with a narrow tolerance. MaraMeter 840 F
HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long
HYDRAULICS H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long 1. General The series of channels H91.8D has been designed by Didacta Italia to study the hydrodynamic
New thermometers and accessories to grow your business
New s and accessories to grow your business Fluke is introducing a new family of digital, contact s and accessories. Here is the information you will need to order, promote and sell these exciting, new
Tungsten Tip Preparation
1 Tungsten Tip Preparation Andra Mandru, August 2011 General aspects and observations: When performing STM measurements, the stability of the tip plays a crucial role. Therefore, a sharp tip which comes
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.
Breezway Altair Powerlouvre Window 35 Breezway Altair Powerlouvre Window The Powerlourve Window motor is neatly concealed within the Easyscreen TM Frame or the Component Powerlouvre Head Section. Automated
Machine Screws, Dowel Pins and Hardware
Machine Screws, Dowel Pins and Section Contents Plain Socket Head Screws...Page 13-2 Wire Locking Screws...Page 13-3 Captive Screws...Page 13- Ventilation Screws...Page 13- Shoulder Screws...Page 13-
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU
6720616592.00-1.SD Flat roof Rack Mounting AU Installation instructions 2 Contents AU Contents 1 Key to symbols and safety instructions....... 3 1.1 Explanation of symbols................ 3 1.2 Safety
Mitos P-Pump. product datasheet
product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
Pressure -Temperature Relationship in Gases. Evaluation copy. Figure 1. 125 ml Erlenmeyer flask. Vernier computer interface
Pressure -Temperature Relationship in Gases Computer 7 Gases are made up of molecules that are in constant motion and exert pressure when they collide with the walls of their container. The velocity and
The University of Toledo Soil Mechanics Laboratory
1 Grain Size Distribution Sieve Analysis The University of Toledo Soil Mechanics Laboratory Introduction The grain size distribution is a representation of the approximate distribution of soil grain sizes
3 Energy Content of Food
Lab Activity 3 ENERGY CONTENT OF FOOD LAB ACTIVITY 3 Energy Content of Food Purpose The purpose of the activity is to measure the energy content of different kinds of food by burning the food to warm a
SenTix 950 SenTix 980
SenTix 950 SenTix 980 ph combination electrodes with refillable liquid reference system Operating manual ba75843e01 08/2009 SenTix The latest version of the present operating manual can be found on the
Cryogenic Performance of Millitech Model FBI-22 Waveguide Isolator.
THE AUSTRALIA TELESCOPE NATIONAL FACILITY AT Technical Document Series AT/39.3/127 May 2, 2006 Cryogenic Performance of Millitech Model FBI-22 Waveguide Isolator. Russell Bolton Russell Gough Two model
MODEL T10023 ACCESSORY KIT #1 FOR T10010/T10097 WET GRINDER
MODEL T0023 ACCESSORY KIT # FOR T000/T0097 WET GRINDER INSTRUCTION SHEET Introduction The Model T0023 Accessory Kit # for the Model T000/T0097 Wet Grinder includes fixtures for sharpening small knives,
CRITICAL POWER MONITORING CPM20/CPM21 DETAILS
CRITICAL POWER MONITORING CPM20/CPM21 DETAILS The Starline Critical Power Monitor (CPM) is a distributed data acquisition system that enables Current and Power monitoring in busway systems. Each phase
Water Baths. with BioCote antimicrobial protection
Water Baths with BioCote antimicrobial protection Water Baths are one of the most common pieces of laboratory equipment used today, the Stuart range offers three sizes 6, 15 and 24L with digital control.
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132
Laboratory- and sterilisation equipment HMC EUROPE
Laboratory- and sterilisation equipment HMC PROFILE HMC Laboratory- and sterilisation equipment Consistent marketing of technologies and the conversion of new ideas create product ranges, that are tailor-made
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
Wind Direction Smart Sensor (S-WDA-M003)
(S-WDA-M003) The Wind Direction smart sensor is designed to work with HOBO Stations. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Station. All sensor parameters
Shakers. designed. to work perfectly
Shakers designed to work perfectly 1 3D Shakers World in motion! For over a century, IKA has been leading the way with invative techlogies and applications in the field of laboratory, analytical and process
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 24 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia S TABLE OF CONTENT SCOPE 2 DEFINITIONS
Adiabatic Bomb Calorimetry
CHEM 366 II-1 Adiabatic Bomb Calorimetry Introduction Obtaining energy in the form of heat from the combustion or oxidation of thermodynamically unstable (and often kinetically inert) hydrocarbons and
TELESCOPE Motorized Lighting Suspension
TELESCOPE Motorized Lighting Suspension Mod. 8400 FEATURES The De Sisti TELESCOPE is a single point suspension specifically designed to provide rigidity and stabilization of all moving parts. It can extend
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
Specific volume and absorption properties
Accepted 1980 Fluff Specific volume and absorption properties 1 Scope This SCAN-test Method describes the preparation of test pieces of fluff and a procedure for their use in determining the specific volume
Environment-Laboratory Ambient Conditions
ISSUE 3.0: MADE MINOR CLARIFICATION CHANGES. FOR CLIENT LABS Purpose To assure laboratory conditions are stable during the performance of testing and data collection. Why this requirement is important?
Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION
M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.
OT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
Corona process The new ZEISS spectrometer system for the food industry
Interactive PDF Version 1.0 Start Trust needs reliability quality needs ZEISS The real challenge is to offer a product with consistent quality using raw materials which are themselves subject to ongoing
H45 LED - Direct and indirect pendant
RAL 01 10 00 IP 20 230V 50/60Hz Specifications Direct and indirect light pendant linear luminaire. Aluminium profile. Diffusers in frosted polycarbonate profile. Driver included. Supplied with clear base,
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.
Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by
AL-System 6 AQUALOOP System 6. Installation and operating instructions WATER IS OUR ELEMENT. www.intewa.com
AL-System 6 AQUALOOP System 6 Installation and operating instructions WATER IS OUR ELEMENT www.intewa.com Table of contents 1. Introduction and general instructions... 2 2. Scope of delivery... 3 3. Technical
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
Integral Kit Instructions
Integral Kit Instructions For Fisher & Paykel Cabinet widths of 525, 635, 680, 790 mm wide For curved door Models Series B, C, D & G Manual 814980 Updated August 2008 IMPORTANT If your refrigerator has