TSX Micro on support with sockets. Study and programming in PLC language



Similar documents
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Programming Logic controllers

Product Information Sheet UH36 Hi Pot Tester

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Quick Connect. quick - simple - efficient.

Charge Controller CC611/CC612 Preliminary datasheet

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Product Information Sheet UH28CS-12kV Hi Pot Tester

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

±15 V Current-Limited Power Supply

PNOZsigma - Base units

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM4TG20 three-phase network control relay RM4-T - range V

NC-12 Modbus Application

Centro-Matic Automatic Lubrication Systems System Controls

Voltage Regulator SPAU 341 C. Product Guide

Smart relays Zelio Logic Step into an intuitive world!

SURGE PROTECTIVE DEVICES

Temperature & Humidity SMS Alert Controller

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Disturbance Recoder SPCR 8C27. Product Guide

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

R.C.C.B. s two-pole LEXIC

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

=============================== WARNING

CB200W Water Leak Detection Panel Application Guide

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Contact expansion modules

Modular I/O System Analog and Digital Interface Modules

Preset Counter signo 721

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Permissible ambient temperature Operation Storage, transport

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

SKR - industry relay

AIS750 Series Alarm Annunciator

Shunt lock function 3066

ICON Server box installation manual Rev. 1.1

EGSTON Standard E2xFxWx 12W

T Substation Maintenance and Commissioning Test Equipment

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Datasheet. PoE Adapters. Provides Earth Grounding and Surge Protection. Helps Protect Against ESD Events. Powers Ubiquiti PoE Devices

HM-W536 Install Guide

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Digital Pressure Measuring Instrument MDR480

48 SERIES Relay interface modules 10 A

*.ppt 11/2/ :48 PM 1

Servo drives. Compact converter IndraDrive Cs

User s Manual Before using the inverter, you need to read and save the safety instructions.

Easily connect your switchboards to facility management solutions

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

E-STOP relays, safety gate monitors

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

ASSEMBLED SOCKET-COMBINATIONS

49 Series - Relay interface modules A. Features

Thyristor-controlled power supplies and battery chargers

Control Devices Catalogue. Control Devices. Preferred and Standard Products

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Programmable Logic Controllers

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018


LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Photovoltaic Solar Energy Unit EESFB

3500/40M Proximitor* Monitor

SELECTION OF FINAL CIRCUIT PROTECTION

Voltech DC1000. Precision DC Bias Current Source

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Installation and Operation Manual

Technical Data. back-up time in minutes 100% load % load

10000HXL31/15000HXL31/20000HXL31

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

INSTALLATION INSTRUCTIONS

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Absolute Rotary Encoder E6CP

Contact expander modules

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

E-STOP relays, safety gate monitors

Operation Guide VIP-45-WIFI. Video Inspection Probe

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Off-grid solar and backup power installations

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

E-STOP relays, safety gate monitors

PLC training panel (Twido version)

Multifunction Digital Timer

38 Series - Relay interface modules A

Multi-Function Ground

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

instabus KNX / EIB System System E F G H

An Alternative Approach to Improving SAIDI and SAIFI Indicators

Transcription:

TSX Micro on support with sockets Study and programming in PLC language

TSX Micro on support with sockets 1. Presentation of the equipment The "TSX Micro on support with sockets" consists in a PLC TSX Micro installed on a support including sockets for various connections. It is designed for people who want to learn programming a PLC in language "List / Ladder, Litteral and Grafcet". 1.1 Composition This assembly is designed for easy and safe connection to operative parts or equipments. A printing next to each socket represents the inputs/outputs. Various LED give information on the operation or the status of the PLC inputs and outputs. A socket for simulation plugged in parallel to the inputs allows testing of a program or an application without operative part. A built-in power supply "Phaseo" 24 Vdc 4,2 A can supply the actuators following their characteristics. www.schneider-electric.com/educationalequipments 3/16

1.2 Data Mechanical data Enclosure : height: 250 mm, width: 400 mm, depth: 350 mm Weight: 5 kg approximately Electrical data Voltage: 230V single-phase ± 10 % Power absorbed: 30 VA Frequency: 50 Hz ± 5 % Current: 16 A, connection by plug 2Ph + Earth Conventional short-circuit current: 3 ka. Rated surge withstand voltage: 2.5 kv Class of protection to electric shocks: ll The electrical network must be fitted upstream of the equipment with an RCD (Residual Current Device) with a sensitivity of 30 ma class AC (not supplied). Technical data of the main components: PLC It is a TSX3721001 with power supply 100-240 Vac including : Internal RAM memory of 20Kwords a slot for a memory extension card a slot for a communication card a terminal socket (TER) a socket for dialogue with the operator (AUX) a back-up battery TSXPLP01. a module 16 inputs 24Vdc / 12 relay outputs a module 8 relay outputs A power supply "Phaseo" 24 V 4,2 A maximum, reference ABL7RE2403. A simulation socket, reference ABE7TS160. 16 yellow safety sockets with the printing: %I1.0 to %I1.15 for connection of inputs. 16 vertes safety sockets with the printing: %Q2.0 to %Q2.11 and %Q4.0 to %Q4.3 for connection of outputs. 3 safety sockets under the inputs/outputs sockets, with the following printings: COM to connect the common points of the outputs in green. 24Vdc 0.4 A maxi: 24 Vdc supplied by the power supply of the TSX Micro in red 0 Vdc: 0 V supplied by the power supply of the TSX Micro in blue. 2 red and blue safety sockets under the "phaseo supply", with the printing: power supply 24 Vdc 3A. A white LED indicator "SOUS TENSION" ("UNDER VOLTAGE"). 4/16 www.schneider-electric.com/educationalequipments

1.3 Main functions The "TSX micro on support with sockets" can be used with or without operative part: Without operative part, simulating a program: Manipulations can be carried out on the PLC: creation or loading of programs, simulation with the switches of the test module and the indicators of the display unit located on the front panel of the TSX Micro. With operative part: Exercises can be carried out on the PLC: creation or loading of existing programs, implementation of the operative part, simulation of a program operation with the switches and the indicators located on the front panel of the TSX Micro. www.schneider-electric.com/educationalequipments 5/16

2. Training course 2.1 Presentation of the training course The "TSX Micro on support with sockets" is used to learn: The various languages, Contacts or Ladder, Grafcet, Litteral, Programming in combinatorial or in sequential, The various function blocks (delay devices, comparators, operations, registers, etc.), Work on words, arithmetic operations, The event tasks, communication through the socket "terminal auxiliary" with various extension units (for instance: dialogue terminal). It is intended for the following educational training cycles: Professional High School University Automated systems industrial computing Electrical engineering Engineering school The hands-on exercises that can be carried out using the "TSX Micro on support with sockets" are different depending on the operative parts connected to it. An example of "traffic management" that can be performed without operative part is given in the following pages. 6/16 www.schneider-electric.com/educationalequipments

2.2 Training example www.schneider-electric.com/educationalequipments 7/16

8/16 www.schneider-electric.com/educationalequipments

www.schneider-electric.com/educationalequipments 9/16

10/16 www.schneider-electric.com/educationalequipments

www.schneider-electric.com/educationalequipments 11/16

12/16 www.schneider-electric.com/educationalequipments

www.schneider-electric.com/educationalequipments 13/16

14/16 www.schneider-electric.com/educationalequipments

3. Items supplied with the equipment 3.1 Devices supplied (Reference MD1AD110) A TSX3721 equipped with: a power supply 24Vdc 3A for inputs and actuators, a socket for simulation, reference ABE7TS160, a cord for mains with a plug 2Ph + Earth 10/16 A for connection to the network, a white indicator. 3.2 Devices not supplied Programming software for TSX Micro in language "Ladder, Litteral and Grafcet" with its cable: PL7 Micro, PL7 Junior or PL7 Pro the micro computer, 3.3 Documentation the extensions, their connecting cable and their software, the cords for safety sockets. A technical manual reference MD1AD111EN www.schneider-electric.com/educationalequipments 15/16

4. Contact details Schneider Electric France Activité Didactique 3F 35 rue Joseph Monier CS 30323 92506 Rueil Malmaison - France http://www.schneider-electric.com/educationalequipments e-mail: FR-didactic@fr.schneider-electric.com 16/16 www.schneider-electric.com/educationalequipments