MidNite Solar E-Panels Explained



Similar documents
FW-X240 AUTO TRANSFORMER Installation Manual

FLOW DIAGRAM OF FIVE DIFFERENT TYPES OF INVERTER SYSTEMS

MIDNITE SOLAR AND SOLAR WASHINGTON

Contractors Guide Central Inverter System Installation

MidNite Solar PV Combiners explained (MNPV)

SOLAR ELECTRIC SYSTEM KITS

Battery Backup for Grid-Tied PV Systems

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Inverter / Charger Installation General Operations and AC and DC Connections

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Applied Electronics. Commercial Dimming System UPDATE NOTICE

HM-W536 Install Guide

Mini Power-Zone Unit Substation

VLT Series 300 Watt True Sine Wave Inverter

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

WHOLESALE DIRECT INC WEST 65TH STREET

Installation and Operation Guide PD4600 Series Converter Replacement

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Battery Power Inverters

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Parallel Redundant Uninterruptible Power Supply

ST Series POWER SUPPLIES USER INSTRUCTIONS

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

RAY-MAX Integrated Solar Power Strip

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

SECTION LOW VOLTAGE LIGHTING CONTROLS

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Freedom SW Sine Wave Inverter/Chargers

Model #: SMART2200CRMXL

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

AC Coupling of Inverters for Grid Tied PV Systems

Intersection Preassembled 19-inch Rack

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where

Best 610 Installation and Operation Manual. Single-phase Input and Output B U and B610010KU Models

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

For Models #6-5001, #6-7501, # & #10-12K1

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Manual. Solar Fountain Mobile Phone Charger

NC-12 Modbus Application

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

THE INPUT/OUTPUT SYSTEM. Key Points

YSmart Technology Co.,Ltd

INSTALLATION & SERVICE MANUAL. Display Panel

Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Specification Requirements DBL 700MX and 1000MX Series UPS

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Distribution Boards & Consumer Units

SYSTEM 4C. C R H Electronics Design

Roy Allen, Technical Training, 17FEB2015 ABB Solar Days Residential Products, Design & Application Rapid Shutdown. ABB Feb 27, 2014 Slide 1

ME-SSI Series Stacking Interface

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Installation and Operation Guide for PD4000 Series Power Control Center

Photovoltaic Solar Energy Unit EESFB

CUTES Solar Power System

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

MCR1900 Media Converter 19-Slot Chassis

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

LIEBERT VNSA Installation Sheet

Product Specification instalert Rapid Messenger Variable Message Sign

Distribution Dry Type Transformers

BB800 Off-Grid Solar System

Model 201 Wiegand Touchpad Reader Installation Guide

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

TruPower-Portable-500W. Solar Starter kit

Air-cooled Generator Battery Charger Installation Guidelines

HMI display Installation Guide

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

MAJORSINE Power Inverter

AC-115 Compact Networked Single Door Controller. Installation and User Manual

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

User s Manual Before using the inverter, you need to read and save the safety instructions.

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

OUTPUT CABLE CONNECTIONS:

AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System

DUMP TARP KITS MANUAL TARP KITS ELECTRIC TARP SYSTEMS MECHANICAL CRANK ARM TARP SYSTEMS

Self Monitoring Power Supply (BPSM)

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

Modular I/O System Analog and Digital Interface Modules

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

New High Current MOSFET Module Offers 177 µω R DS(on)

AC Coupling Grid Tie Inverters With OutBack Battery Based Inverters

Operating Instructions

This page is subject to proprietary rights statement on last page

RV Solar Power Guide

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Transcription:

MidNite Solar E-Panels Explained A MidNite Solar E-panel is an AC/DC Disconnect Box that has the Inverter installed on the door of the E-Panel or above the E-panel. MidNite's E-Panels place the AC and DC breakers in the same Disconnect Box for a compact solution. MidNite makes E-Panels for Magnum, Outback, Schneider Conext SW, Schneider XW and SMA Sunny Islands. Each E-Panel contains a battery disconnect breaker, AC input and output breakers with appropriate bus bars, 120V and 120/240V configurations, bypass breaker, neutral and ground bus bars, shunt and mounting hardware. All units have knockouts for surge protection and conduit connections. The E-panels all have spaces for additional breakers such as for charge controllers and loads. Magnum Energy 120VAC E-Panels for MS and RD series Magnum Energy makes a very interesting line of inverters, both modified and pure sine wave. Internal AC wires are routed to match the Magnum inverter. The accessory components like the DC cover, top shield, remote bracket and such are specific to the Magnum E-Panels. The Magnum has a PV input plus and DC plus busbar as well as the regular AC input and output busbars. This chassis is 14.4 inches wide, so has ample room for all your wiring needs. The chassis is only 3.5" deep so wiring access is the best in the industry. All of the present 12 and 24 volt / 120VAC Magnum inverters have a 120VAC inverter/charger input/output as well as a 120VAC input/output that does not go through the electronics. It is strictly a pass through for the other leg of a 240VAC input. The pass through leg can be useful when attempting to utilize both legs of a 240VAC generator. One leg is used for charging and the other is used to pass through to your 240VAC deep well pump. The 120VAC E-Panel here is not able to handle the extra leg of AC, so look to the 240 E-Panel to accommodate this unique feature. Normal installations jumper AC 1 & 2 on the inverter for 50 amp service at 120VAC. A major advantage of these E-Panels is that they can be tested in the shop to insure that the system is functioning properly. These E-Panels can be field modified to be right hand units. A right hand door is required to do this in the field. 1

The Magnum Energy 240VAC E-Panel for PAE series This is our flagship E-Panel. It accommodates the Magnum Energy MS4448-PAE and MS4024-PAE inverters. These inverters are a true 120/240 input and output. Unlike the regular Magnum MS and RD series that have a second 120VAC pass through leg, these inverters are like having a stacked pair of inverters. It will charge from either a 120VAC source or a 240VAC source. The output is 120/240 just like the utility grid. Compare this system with a stacked pair of 120VAC inverters (from any company) and you will realize thousands of dollars of savings! The Magnum 240VAC E-Panel uses a white steel chassis to match the MS series. It has black and red AC input and output terminal bus bars, red terminal bus bars for PV+ and Bat+, six additional din rail slots, 500A shunt, ground busbar, remote bracket, wall mount brackets, inverter cables, charge control mounting bracket, 120/240 AC bypass switch pre-wired and a 120/240 AC input disconnect prewired. Outback AL PLUS and STS Models These E-Panels come standard with the AC bypass and AC input disconnect pre-wired into the box. It has din-rails for six additional 13mm wide AC or DC breakers along with a battery breaker installed with inverter plus and minus cables. There is a 500 amp/50mv shunt, a battery plus busbar plus a number of features included: battery minus busbar, AC busbars, ground busbar, DC cover, AC flex conduit tubing with couplers, MX60/Classic mounting bracket, grommets and bushings, numerous knock outs for cable entry and exit, lots of hardware for mounting inverter, charge controller etc., wall mounting brackets, installation instructions, wiring diagram mounted on the door. All AL PLUS models are white aluminum and are used in places like Hawaii or Maine or wherever salt air is a factor. Aluminum E-Panels also weigh 9 pounds less than the STS gray powder coated steel versions. These models can be purchased in right hand versions. Schneider Conext SW and XW E-Panels The Conext SW E-Panels are perfect for off-grid, backup power and self-consumption applications. They are made for a single Schneider Electric Conext SW inverter/charger. The SW inverter is mounted directly to the right of the E-Panel. The Conext SW s are available with the 175 amp breaker (MNE175SW) for the SW2524 inverter or with the 250 amp breaker (MNE250SW) for the SW4024 inverter. The MNE175SW or MNE250SW features inverter battery breaker, knockouts for up to 6 din rail mount AC or DC breakers (or the optional Bypass Kit) and 4 panel mount or DC-GFP80 breakers. Massive tin plated copper bus bars directly connect to the SW s battery terminals, bus bars for AC inputs, AC output, neutral, ground, PV + in, PV- in, Bat +, Bat-, 500 amp shunt, Location to mount two charge controllers to the top. There are knockouts that correspond to the 1 inch knock outs in the charge controller. The Conext XW E- Panels are perfect for grid-tie and AC coupled applications. MNE250XWP-SINGLE 2

The Conext XWs feature: Inverter battery breaker 2 separate 60 amp AC inputs for generator and utility 60 amp AC bypass switch Knockouts for up to seven din rail mount DC DCGFP63 or AC breakers and 12 panel mount or DC-GFP80 breakers Massive tin plated copper bus bars directly connect to the XW s battery terminals Bus bars for AC inputs AC output neutral, ground, PV + in, PV- in, Bat +, Bat- 500 amp shunt (MNSHUNT) Metal dead front behind the reversible door Charge controllers mount to either side or both sides at once for dual controllers AC bypass can be configured as input & output on/off as well as AC bypass.(note: The XW 60 amp controller can mount on the Right side only due to their isolated communications compartment) The XW MPPT controller requires no mounting bracket. FM60, FM80 and Classic require Right or Left E-Panel charge control mounting brackets. Right hand bracket furnished standard. Main Breaker Current Rating 175 and 250 Number of breaker spaces - 19 Environmental Rating - Type 1 (Indoor) Max. Wire Size - 4/0 AWG Max. AC Voltage - 240VAC Max. DC Voltage - 300VDC Warranty - 5 yrs. Listed by ETL for US & Canada Made in the USA SMA E-Panels MNE250SMA-AC-SINGLE Master E-Panel is for a single Sunny Island AC Coupled system. (MidNite Autoformer and SunnyBoy inverter required) The MNE250SMA-AC SINGLE Master includes the input/output 60amp, 120/240vac bypass system along with separate 60 amp, 120/240vac AC input and output breakers. This E-Panel comes with a 250amp remote trip battery disconnect breaker and inverter cables. Pre-wired with AC input and output wiring. RS485 boards are required when AC Coupling to SunnyBoy inverters if 3 stage charging is desired. MNE250SMA-AC-SINGLE Master One RS485 board goes into the Sunny Island inverter and each SunnyBoy Inverter. AC Coupling to the SunnyBoy grid-tie inverter is possible without RS485 boards. The Sunny Island grid-tie inverter will frequency shift based on battery voltage to knock the grid-tie inverter off line. SunnyBoy inverters can switch between off-grid and grid-tie mode automatically when RS485 boards are used. To program this feature you must use either a SMA service cable (USBPBS) or SMA web box (SUNNYWEBBOXU). 3

The backed up critical loads panel always has 120/240vac available. 60amps is available on leg 1 and 30amps on leg 2 in the critical loads panel. Comes standard with one MNSPD-300 (surge protection device). MNE250SMA-OG-SINGLE - The Off Grid Single is designed for a single Sunny Island off grid system. It includes the 60amp, 120vac Manual input/output bypass system along with separate 60amp, 120vac AC input and output breakers. Comes with a 250amp battery disconnect breaker and inverter cables. Pre-wired with AC input and output wiring. NOTE: A back plate (MNESMA-Short BP or MNESMA-Tall-BP) is recommended for the proper wiring./ MNE250SMA-OG-SINGLE FEATURES: 60amp, 120vac AC output/bypass assembly and independent 60amp MNE250SMA-OG-SINGLE 120vac AC input and output breakers 500A/50mV shunt (MNSHUNT) Neutral and AC IN and OUT terminal busbars 250amp remote trip battery breaker with inverter cables AC wiring to inverter. alignment of the Sunny Island. Warranty - 5 yrs. Listed by ETL for US & Canada Made in the USA MNE250SMA-OG/AC DM - The Dual Master E- Panel works with one of the MNE250SMA-Slave E-Panels to create a 120/240 VAC AC coupled or off -grid system. The MNE250SMA-OG/AC DM includes the 60amp, 120/240vac input/output bypass system. Terminals are provided for hookup to leg 2 from the Slave E-Panel. Comes with 250amp battery disconnect breaker and inverter cables. Pre-wired with AC input and output wiring for leg 1 (master) inverter. (One slave E-Panel is required for 120/240.) MNE250SMA-OG/AC DM 4

MNE250SMA-OG/AC DM FEATURES: 60amp, 120/240vac Output/Bypass system Separate 60amp, 120/240vac AC input and output breakers for the master inverter 250amp remote trip battery breaker with inverter cables 500amp/50mV shunt (MNSHUNT) Battery negative busbar AC input and output busbars Neutral and ground busbars AC input and output wiring All breakers are hydraulic-magnetic and rated for continuous duty Space provided for 6 additional 1/2" wide din rail mount AC or DC breakers and up to 12 3/4" wide panel mount breakers Knockouts located for battery cables AC conduit connections Warranty - 5 yrs. Listed by ETL for US & Canada Made in the USA MNE250SMA-QUAD MSTR - This E-Panel works with three of the MNE250SMA-Slave E-Panels to create a Quad stack of Sunny Islands. The MNE250SMA-Quad Mstr includes the Quad 125amp, 120/240vac input/output bypass system. This E-Panel can be used in conjunction with a Sunny Island inverter as part of a Quad off-grid, battery backup or AC Coupled system. Terminals are provided for hookup to leg 1 + 2 in the Slave E-Panels. This unit comes with a MNE250SMA-QUAD MSTR 250amp remote trip battery disconnect breaker and inverter cables and is pre-wired with AC input and output wiring for leg one (master) inverter. (Three slaves are also required for Quad system.) NOTE: A back plate (MNESMA-Short BP) is recommended for the proper wiring alignment of the Sunny Island. MNE250SMA-QUAD MSTR FEATURES: 125amp, 120/240vac AC Output/Bypass system Separate 60amp, 120/240vac AC input and output breakers for the master inverter 250amp remote trip battery breaker with inverter cables 500amp/50mV shunt (MNSHUNT) Battery negative busbar AC input and Output busbars Neutral and ground busbars AC input and output wiring Transition terminals to Slave E-Panels Space provided for 6 additional 1/2" wide din rail mount AC or DC breakers and up to 12 3/4" wide panel mount breakers. All breakers are hydraulic-magnetic and rated for continuous duty. Knockouts located for battery cables 5

AC conduit connections Warranty - 5 yrs. Listed by ETL for US & Canada Made in the USA MNE250SMA-3PH Master - The MNE250SMA- 3PH Master E-Panel works with two of the MNE250SMA-Slave E-Panels to create a three phase system. The MNE250SMA-3PH Master includes the three phase 60amp input/output bypass system. This E-Panel can be used in conjunction with a Sunny Island inverter as part of a three phase off-grid, battery backup or AC Coupled system. Terminals are provided for hookup to leg two and leg three E-Panels. MNE250SMA-3PH Master This unit comes with 250A remote trip battery disconnect breaker and inverter cables. The MNE250SMA-3PH Master E-Panel is pre-wired with AC input and output wiring for leg one (master) inverter. (Two slaves are also required for three phase.) The three phase master includes the three phase 60amp input/output bypass system. This E-Panel can be used in conjunction with a Sunny Island inverter as part of a three phase off-grid, battery backup or AC Coupled system. Terminals are provided for hookup to leg two and leg three E-Panels. Comes with 250amp battery disconnect breaker and inverter cables. This unit is pre-wired with AC input and output wiring for leg one (master) inverter. (Two slaves are also required for three phase.) This E-Panel does not come with a relay board, RS485 (485USPD-NR) boards or MNSPD surge protection device. RS485 boards are required when AC Coupling to SunnyBoy inverters if three stage charging is desired. One RS485 board goes into the master inverter and each SunnyBoy Inverter. AC Coupling to a SunnyBoy or any other grid-tie inverter is possible without RS485 boards. The Sunny Island inverter will frequency shift based on battery voltage to knock the grid-tie inverter off line. SunnyBoy inverters can switch between off-grid and grid-tie mode automatically when RS485 boards are used. To program this feature you must use either SMA service cable (USBPBS) or SMA web box (SUNNYWEBBOXU). MNE250SMA-SLAVE - The MNE250SMA-SLAVE is a companion E- Panel for dual, triple and quad Sunny Island inverter systems. The Slave E-Panel is the same part number for all multiple SMA E-Panel systems regardless of off-grid, AC coupled, battery backup, three phase or quad. Separate 60amp, 120/240vac AC input and output breakers for the slave inverter 250amp remote trip battery breaker with inverter cables 500amp/50mV shunt (MNSHUNT) Battery negative busbar AC input and Output busbars Neutral and ground busbars MNE250SMA-SLAVE AC input and output wiring Comes with Red busbars installed Additional black and blue insulators included for tailoring to suit the application 6

Space provided for 6 additional 1/2" wide din rail mount AC or DC breakers and up to 12 3/4" wide panel mount breakers Mounting hole spaces for additional terminal busbars Knockouts located for battery cables AC conduit connections Warranty - 5 yrs. Listed by ETL for US & Canada MNX-240 AUTOFORMER - The 6000 Watt Autoformer (based around SMAs Toroid) is for turning a Single Sunny island 120vac inverter into a 120/240vac inverter. The MNX-240 AUTOFORMER is useful for using the single Sunny Island to AC couple with multiple grid-tie inverters. NOTE: A back plate (MNESMAXW-SHORT BP or MNESMA-TALL-BP) is recommended for the proper wiring alignment of the Sunny Island. MNX-240 AUTOFORMER 7