Pentra DX Nexus. Process efficiency in Hematology

Similar documents
BC Auto Hematology Analyzer

XE-2100 Automated Hematology System. Fast, Accurate, Dependable

Reshaping compact automation. XN-Series Automated Hematology Systems

HumaCount System Line A Better Way to Connect. A Better Way to Work.

Preparation of Blood Films

cobas 6500 urine analyzer series Fully automated urine work area on a modular platform

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

QUALITY CONTROL (QC) INFORMATION AND TROUBLESHOOTING GUIDE HEMATOLOGY

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

KIP 2300 HIGH PRODUCTION CCD SCAN SYSTEM

Hematology Morphology Critique

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

Peel Back Force Tester GPD s Peel Back Force Tester with FORCEWare software is being used to set peel back standards for the entire industry

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

R&D Systems Hematology Products

Discover Your Potential

Discover Your Potential

Pathology No: SHS-CASE No. Date of Procedure: Client Name Address

INNOVATION TO MEET YOUR NEEDS

GC-xt. The most flexible GC /GC-MS liquid sample injector

Laboratory 12 Blood Cells

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

73 Series Spectrophotometers

Datex-Ohmeda Critical Care Monitor

Cedex Bio HT Bioprocess Analyzer. Be Confident. Be Assured.

Scout 1U Rackmount Computer

Department of Pathology and Laboratory Medicine Capital District Health Authority Nova Scotia

How do I Check if My Computer is Compatible with Windows 7

Intelligent laboratory management Delivered by cobas IT middleware

Cell Viability You Can Count On

DCS Data and communication server

Expert workflow management cobas p 312 pre-analytical system The new dimension of laboratory automation

KIP 720 CIS SCANNING SYSTEM WITH ADVANCED KIP REAL TIME THRESHOLDING TECHNOLOGY

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

STAINING OF PBF AND INTERPRETATION OF NORMAL AND ABNORMAL RED CELL MORPHOLOGY

3500/93 System Display

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

High voltage tester HA 1800 Table-top device

Fluorescent Array Imaging Reader

Lab 02: Blood Cytology (20 points)

Standardization, Calibration and Quality Control

thyroid uptake systems

v1 System Requirements 7/11/07

HP Server Console Switch with Virtual Media Overview

Hematology Reagents and Controls Our products for your critical process

SA-9600 Surface Area Software Manual

Unleash Your Potential

ADVANCED DIRECT IMAGING. by ALTIX

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

EC-12R EC-12RM EC-12R/S EC-12SResting and Stress ECG Family. Technical specification

Fiber Optic Distributed Temperature Sensor (B-DTS)

Barcode Reader Series BCL 31, BCL 32, BCL 34

DIODE PUMPED CRYSTALASER

Tracer Summit Web Server

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

HDO700 P FIBRE OPTIC TRANSMITTER

QuickSpecs. HP IP Console Switch with Virtual Media Overview

Nederland België / Belgique

How To Use Bodescan For 3D Imaging Of The Human Body

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

Coatron A4. Fully automated Hemostasis Analyzer. Made in Germany REF: Innovation in Coagulation

Cisco 7816-I5 Media Convergence Server

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

HORIZON Software Materials testing data acquisition and analysis software

OT 40L / 90L. Laboratory Steam Sterilizers

Symmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE

Minimum Hardware Specifications Upgrades

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Computer Requirements

1/4 Specifications Hidex 300 SL automatic TDCR liquid scintillation counter

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

TrueAlarm Fire Alarm Systems

D Next-generation LED phototherapy NanoBlu 500

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

Calibration Verification

Rugged and open to your applications

Computer Creep System

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Phaser 5550N Adds 10/100/1000 Ethernet

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Industrial Bar Code Scanners

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

LABORATORY 2 Staining and processing of blood parasites Differential counts of leukocytes (giemsa stains)

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

Overland 2 TB SnapServer 210 NAS Server. Overland 4 TB SnapServer 210 NAS Server Operating System GuardianOS GuardianOS

UniOP epad33 and epad33t

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

Centralized Orchestration and Performance Monitoring

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

Cronos -1 Gamma Object / Tool Monitors

Georgia Northwestern Technical College Practical Nursing Program CLINICAL DAILY ASSESSMENT WORKSHEET FOR MODULES I-IV STUDENT: CLINICAL INSTRUCTOR:

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

Thyroid Uptake Systems The Ultimate... User Friendly... Intuitive Captus 3000 Thyroid Uptake And Well System

Artikel-Detailinformationen

COULTER LH 750 HEMATOLOGY ANALYZER. COULTER LH 780 HEMATOLOGY ANALYZER Training Modules. This Training Guide belongs to:

RiMatrix S Make easy.

Transcription:

Pentra DX Nexus Process efficiency in Hematology

Pentra DX Nexus Be productive and flexible 120 samples per hour 28 parameters Automatic reflex testing Automatic validation of results Integrated cytology atlas SPS evolution Reliability Comfort Large color touch screen. Intuitive interface with virtual keyboard. Ergonomics Ergonomics Smart access to all functionalities. Enhanced visibility. Comprehensive icons. External links USB port for multi-data exchange and hardware connection.

Hematopoiesis through Pentra DX Range Differentiation and quantification of hematopoietic populations using 6 analytical systems SCIENTIFIC BOOK > Erythropoiesis 3 channels: erythroblasts / reticulocytes / erythrocytes > Thrombopoiesis 1 channel: thrombocytes > Leukopoiesis 3 channels: leukocytes / basophils / erythroblasts Concentrated Technology 5 recognized measurement principles included on a single analyser. Reference methods Impedancemetry Flow cytometry CBC DIFF RET NRBC Fluorometry Cytochemistry DHSS In the heart of hematopoiesis Comfort (1) (2) (4) (3) Quality Complete traceability for each run including identification, lot number and expiration date on reagents and controls. Compatibility Compatible racks with most pre-analytical systems and post analytical systems. Two models of racks. Environment New laser source require less space, reducing heat and noise. (1) Laser LED (2) Photomultiplier (3) Hydrofocalisation (4) Impedancemetry (5) Optical mesurement (5)

DHSS Concept Flow cytometry Injection of the sample prepared in a double hydrodynamic flow cytometer (HORIBA Medical patent), and determination of the cell complexity by measuring the absorbance of a polychromatic light source, or the fluorescence by fluorocytometry (Diode type laser at 488 nm wavelength). LMNE matrix Full leukopoiesis analysis: Mature populations 5 DIFF Reduced slide review Diagnostic and follow-up tool for rapid decision-making Erythroblasts Fluorescence-based count: Erythroblast analysis in routine or reflex mode based on: - internal laboratory rules - detection alarms - patient demographics... Use of Thiazole Orange fluorochrome Double Hydrodynamic Sequential System (HORIBA Medical Patent) Reticulocytes Differential diagnosis of anemia: Classification and monitoring of anemia based on the Reticulocyte count and the CRC (Corrected Reticulocyte Count) Follow-up of iron-deficiency anemia based on the MRV (Mean Reticulocyte Volume) Detection and monitoring of the erythropoietic response according to three stages of maturation: RET High, RET Medium, RET Low and maturation parameters (IRF, MFI, and MRV) Erythroblasts Reticulocytes Red blood cells Cytochemistry Incubation of the sample at a regulated temperature and cells stained with Chlorazol Black. This reagent stains specifically leukocyte cytoplasm, granules, and nuclei.

SPS Evolution Perfect standardization of blood smears Integrated slide-maker* 120 slides per hour Fully automated and secured process Positive identification Barcode reading Patient data printed automatically on slide Choice of staining protocols May-Grünwald Giemsa, Wright, Wright Giemsa, etc. Smearing flexibility User-defined smearing profiles based on the laboratory s own rules Sampling volume: 50 µl of whole blood (additional) On primary closed tube * Optional module Expert validation station Results validation Full management of samples Alarms triggered according to patient profile Delta check Programmable rerun and reflex test rules Automatic validation Standardization of Lab rules (integrated catalog) International recommendation rules for Hematology review (ISLH, Laboratory Hematology 11:83-90 2005 Carden Jennings Publishing Co., Ltd. doi: 10.1532/LH96.05019) integrated in routine Automatic validation based on rules, flags, patient history, etc. Integrated cytology atlas: Hematovision Aid to accurate diagnosis support Excellent education tool Quality assurance Control blood management Graphical and table statistics XB management QCP Export (Quality Control Program) Complete traceability (reagents & controls) for each run

Pentra DX Nexus Technical Specifications PHYSICAL SPECIFICATIONS Dimensions & Weight Height Without SPS 73 cm 28.7 in With SPS 73 cm 28.7 in Width 120 cm 47.2 in 170 cm 66.9 in SOFTWARE SPECIFICATIONS Depth 55 cm 21.6 in 55 cm 21.6 in Weight 110 kg 242.5 lb 170 kg 374 lb Printer Laser Throughput Up to 120 samples/hour in CBC, DIFF, CBR, SPS modes Up to 60 samples/hour in DIR, ERB, CBE modes Quality Control Management 48 selectable QC files XB: 100 operator selectable files with statistics (20 samples per file) With-in run Levey-Jennings graphs Operating temperature 16-34 C (61-93 F) room temperature Specimen volume Manual cycle 130 µl Automatic cycle 200 µl Logs Reagents, quality control, calibration, maintenance, user, settings, communication, errors, blanks Power requirements Power supply from 100 VAC to 240 VAC (± 10) 50 Hz to 60 Hz Power consumption Pentra DX120 900 VA PERFORMANCE DATA Reagents ABX Diluent ABX Lysebio (cyanide free) ABX Fluocyte ABX Leucodiff ABX Basolyse ABX Cleaner Linearity Parameters WBC RBC HGB HCT PLT PARAMETERS CBC WBC RBC HGB HCT MCV MCH MCHC RDW PLT MPV Differential Leukocytes NEU# & NEU LYM# & LYM MON# & MON EOS# & EOS BAS# & BAS Reticulocytes RET RET# RETH RETM RETL IMM CRC IRF MRV PLT (platelet concentrated) Standard 0.1-150 0.01-8 0.65-24 1-67 6-1900 6-2800 Unit 106/mm3 g/dl Precision: Parameters WBC RBC HGB HCT PLT NEU LYM MON EOS BAS Range 4.0-10.0 3.6-6.2 12.0-18.0 36-54 150-500 45-80 25-50 2-10 1-5 0.5-2.5 Units 106/mm3 g/dl CV <2 <2 <1 <2 <5 <3 <5 < 10 < 20 < 30 CERTIFICATION EN 61326: 2001 IEC 61000-3-2 : 2000 IEC 61000-3-3 : 2001 IEC 61010-1 : 2001 IEC 61010-2-081 : 2001 IEC 61010-2-101 : 2002 CE 98/79/EC AD-040913-1 Rev.1 Erythroblasts ERB ERB# Data Processing Color LCD: 12.1 in Capacity: 90,000 results Operating System: Windows XP Embedded Processor: Genuine Intel 1.60 GHz RAM (Random Access Memory): 1 GB External DVD/CD drive connected to instrument USB port RS 232C, 5 X USB1 User defined flagging limits Transmit patient & QC to LIS Mono & bi-directional connections 949 453 0500 888 903 5001 www.horiba.com/medical