D Next-generation LED phototherapy NanoBlu 500

Size: px
Start display at page:

Download "D-39740-2011. Next-generation LED phototherapy NanoBlu 500"

Transcription

1 D Next-generation LED phototherapy NanoBlu 500

2 02 Is there a powerful phototherapy device that s really compact? D

3 03 BETTER TREaTMENTS SuPPoRT BETTER outcomes The effective treatment of hyperbilirubinemia (jaundice) is crucial to newborn health. Some 60% of normal newborns become clinically jaundiced sometime during the first week of life. 1 If not treated in time, jaundice can cause severe physical damage to the child. In effect, the better the jaundice treatment, the better the outcome. NEXT-GENERaTIoN LED PHoToTHERaPY At Dräger, our focus on minimal stress therapies has led to the development of jaundice screening and therapeutic solutions that are non-invasive, simple-to-use, and highly effective. Designed to meet AAP guidelines for intensive phototherapy, the Dräger NanoBlu 500 is a compact, powerful phototherapy unit for the treatment of hyperbilirubinemia in newborn infants. With light-emitting diodes (LEDs) that emit blue light in the nm spectrum, NanoBlu 500 is aligned with the peak absorption wavelength (450 nm) at which bilirubin is broken down. 2 EaSY on THE BaBY, EMPoWERING FoR THE CaREGIVER Innovative technology enables the NanoBlu 500 to evenly distribute high irradiance with only five LEDs and you can adjust irradiance levels for the specific needs of each infant. An optional integrated radiometer with optical sensor enables you to regularly monitor the light intensity of the phototherapy as recommended by most hospital protocols. In addition, you can automatically document irradiance measurements and download that information to a computer and/or printer for a more complete record. 1 Maisels, M.J. and McDonagh, A.F. Phototherapy for Neonatal Jaundice. New England Journal of Medicine, volume 358, number 9, February 28, 2008, pages Vreman HJ, et al. Light-emitting diodes: a novel light source for phototherapy. Pediatric Research. 1998; 44(5):

4 4 Customizable & connected phototherapy Control & Innovation Control specific irradiance level from 10 to 100%: allows you to accurately match your hospital protocol requirements Access full menu from one interface: provides fast access to device settings, maintenance and calibration, time and calendar, device usage data Generate reports containing hour counter, time of exposure, calendar/clock, and stored irradiance files: lets you document the performance of the phototherapy session Effective application High intensity levels Provides optimal spectrum levels Distributes light uniformly across body of infant Does not require touching the baby or placing an additional device directly in their proximity, which is important for very low birth weight infants D Practicality Trolley or hood-mount option adds flexibility to the work space around the baby Highly flexible and adjustable positioning on babies in incubators or warmers Optional integrated radiometer with optical sensor to ensure optimal performance Long-lasting LED technology and low power consumption compared to fluorescent lights

5 5 Dräger NanoBlu 500 is the first line of defense for the effective treatment of jaundice. It delivers the key criteria for effective phototherapy: the right spectrum of light, at the right intensity, to as much of the baby s skin as possible in a compact, easyto-use package. 50 cm (19.69 ) 40 cm (15.75 ) 30 cm (11.81 ) 14 cm (5.51 ) µw/cm 2 -nm 16 cm (6.3 ) µw/cm 2 -nm 18 cm (7.09 ) µw/cm 2 -nm The Dräger NanoBlu 500 includes five LEDs that provide a high level of blue-spectrum light. They are composed of an Indium and Gallium Nitride (InGaN) semiconductor structure, which enables the use of fewer LEDs and eliminates ultraviolet and infrared filters. The light provides a large ellipse of medium-intensity light coverage, allowing for more light to reach the infant.

6 6 TECHNICaL DaTa Device classification Protection class of trolley mount Class I, continuous operation equipment without applied parts Protection class of hood mount Class II, continuous operation equipment without applied parts Ingress of liquids IPX0, regular equipment - not waterproof Classification in accordance with EU Directive Device class IIa 93/42/EEC Appendix IX UMDNS code/gmdn code 17516/34477 Power Requirements 100 V~ to 240 V~, 50/60 Hz, 50 VA, 1.5 A Physical specifications Dräger nanoblu 500 hood Mount Width Depth Height Net weight Weight when packaged 11.6 cm (4.57 in) 23.0 cm (9.06 in) 5.0 cm (1.97 in) 1.0 kg (2.2 lb) 3.0 kg (6.6 lb) Dräger nanoblu 500 trolley Mount Width Depth Height Net weight Weight when packaged 50.0 cm (19.69 in) 50.0 cm (19.69 in) cm to cm (39.37 in to in) 9.0 kg (19.8 lb) 14.0 kg (30.9 lb) irradiance at 30 cm (11.81 in) Illuminated area fulcrum Minimum 40 μw/cm 2 nm (+10 %) Illuminated area dimensions 40 cm by 37 cm (15.75 in by in) Irradiance adjustment band 10 % to 100 % of maximum irradiance (+10 %) Irradiance adjustment increment at every 10 % optical sensor/radiometer Measurement band Resolution Reading accuracy 0 μw/cm 2 nm to 200 μw/cm 2 nm 0.1 μw/cm 2 nm ±2 μw/cm 2 nm Noise < 52 dba electrical specifications Power Supply Output voltage Output power Input voltage Operating frequency Universal input power supply 12 VDC 50 W VAC 50/60 Hz

7 7 environmental RequiReMents temperature range Operating Storage 18 to 28 C (64.4 to 82.4 F) -20 to 60 C (-4 to 140 F) Relative humidity Operating Storage 10 % to 95 % (non condensing) 10 % to 95 % (non condensing) atmospheric Pressure Operating Storage 700 hpa to 1060 hpa 500 hpa to 1060 hpa Data transmission RS-232 serial port Standard UART protocol Bits per second 9600 bps Data bits 8 Parity None Stop bits 1 Flow control None standards IEC :1988 Medical Electrical Equipment, Part 1: General Requirements for Safety UL st Edition, 2006 Medical Electrical Equipment, Part 1: General Requirements for Safety CAN/CSA-C22.2 No M90, 2005 IEC :2000 Medical Electrical Equipment, Part 2: Particular requirements for the safety of infant phototherapy equipment IEC :2001 Medical electrical equipment -- Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests NanoBlu 500 offers a variety of mounting options.

8 Corporate headquarters Drägerwerk AG & Co. KGaA Moislinger Allee Lübeck, Germany USA Draeger Medical, Inc Quarry Road Telford, PA , USA Tel Toll-free Fax CANADA Draeger Medical Canada Inc. 120 East Beaver Creek Road Suite 104 Richmond Hill Ontario L4B 4V1, Canada Tel Toll-free Fax Manufactured for: Draeger Medical Systems, Inc. Telford, PA 18969, USA The quality management system at Draeger Medical Systems, Inc. is certified according to ISO and ISO Marketing Communications SL Neo Printed in the United States Chlorine-free environmentally compatible Subject to modifications 2012 Drägerwerk AG & Co. KGaA

Sample Usage Protocol Jaundice Meter JM-105

Sample Usage Protocol Jaundice Meter JM-105 D-94164-2013 Sample Usage Protocol Jaundice Meter JM-105 This Sample Usage Protocol is provided as a template for creating a facility or department-specific protocol for using the Dräger Jaundice Meter

More information

D-94164-2013. Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105

D-94164-2013. Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105 D-94164-2013 Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105 2 Assessing jaundice risk without the trauma D-94313-2013 D-7346-2009 While neonatal jaundice or hyperbilirubinemia

More information

D-9282-2009. Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM

D-9282-2009. Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM D-9282-2009 Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM 02 Alarm Management System The central gas supply is one of the hospital s life support systems, and as such is subject to special

More information

The bridge to more efficient care PONTA SUPPLY BEAMS

The bridge to more efficient care PONTA SUPPLY BEAMS MT-4159-2007 The bridge to more efficient care PONTA SUPPLY BEAMS 02 PONTA SUPPLY BEAMS more versatile MT-4056-2007 MT-3978-2007 MT-3965-2007 MT-3987-2007 Uniting improved care with individual flexibility

More information

The column to efficient care DRÄGER GEMINA DUO

The column to efficient care DRÄGER GEMINA DUO MT-0798-2008 The column to efficient care DRÄGER GEMINA DUO 02 Dräger a century of care competence Today, hospitals are under increased pressure to provide state-of-the-art care with less staff and on

More information

Oxylog 3000 plus Emergency & Transport Ventilation

Oxylog 3000 plus Emergency & Transport Ventilation Oxylog 3000 plus Emergency & Transport Ventilation Offering high ventilation performance with features such as AutoFlow integrated capnography and non-invasive Ventilation, the compact and robust Oxylog

More information

Polaris 5xx/7xx Medical Lights and Video

Polaris 5xx/7xx Medical Lights and Video Polaris 5xx/7xx Medical Lights and Video Without light, surgery just isn t possible. Sufficient light is one of the fundamental requirements for the operating theatre. The Polaris lights were designed

More information

Dräger PARAT Escape Hoods

Dräger PARAT Escape Hoods Dräger PARAT Escape Hoods Airborne toxins present an immediate danger to the health of a workforce. When environments turn toxic, a fast, safe escape is crucial. Dräger PARAT Escape Hoods are designed

More information

Infinity Central Monitoring and Remote Access Solutions

Infinity Central Monitoring and Remote Access Solutions Infinity Central Monitoring and Remote Access Solutions Reaching beyond the point of care Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care At Dräger, we re committed

More information

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

Dräger Alcotest 9510 Evidential Alcohol Measuring Device Dräger Alcotest 9510 Evidential Alcohol Measuring Device The Dräger Alcotest 9510 is an advanced breath alcohol measuring instrument for evidential applications. It is designed to comply with national

More information

Anesthesia Information Management DRÄGER INNOVIAN ANESTHESIA

Anesthesia Information Management DRÄGER INNOVIAN ANESTHESIA D-24993-2010 Anesthesia Information Management DRÄGER INNOVIAN ANESTHESIA D-24994-2010 Imagine a solution that puts the focus back on the patient by automating the anesthesia patient record giving you

More information

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications Bar Code Reader Series BCL 20 A flexible reader for a variety of applications PRODUCT INFORMATION The benchmark for flexibility. Laser scanners of the BCL 20 series as variable as your requirements demand.

More information

Dräger Globe-Trotter GT5400 Neonatal Transport

Dräger Globe-Trotter GT5400 Neonatal Transport Dräger Globe-Trotter GT5400 Neonatal Transport The Globe-Trotter GT5400 is the result of Dräger s ongoing commitment to developing a safer and more stable neonatal transport system. This system meets global

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying

Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying Concentrated liquid cleaning agent for manual cleaning of respiratory masks, respiratory protection equipment, diving apparatus

More information

Guideline Laser Series

Guideline Laser Series Guideline Laser Series Highly visible alignment laser for visually demanding surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)

More information

Dräger X-dock Release Notes Software-Update 01.07.00 and Manager Software 1.7.0

Dräger X-dock Release Notes Software-Update 01.07.00 and Manager Software 1.7.0 Supported operating system (X-dock Manager) Windows 7 Windows 8 Windows Server 2008 R2 Windows Server 2012 R2 Supported firmware versions (X-dock Manager) X-am 2000: > = v6.0 X-am 2500/5x00: > = v6.6 Pac

More information

D-1188-2009. Move life-critical patient data on your existing network INFINITY ONENET

D-1188-2009. Move life-critical patient data on your existing network INFINITY ONENET D-1188-2009 Move life-critical patient data on your existing network INFINITY ONENET 02 One Network rather than two MT-1351-2007 Patient monitoring data is life-critical. That s why hospitals have traditionally

More information

Moving beyond telemetry INFINITY M300

Moving beyond telemetry INFINITY M300 D-19757-2009 Moving beyond telemetry INFINITY M300 02 MT-4187-2006 MT-4488-2006 D-19730-2009 03 Transforming telemetry into patient-worn monitoring From the standpoint of patient monitoring, today s busy

More information

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust

More information

Datex-Ohmeda Critical Care Monitor

Datex-Ohmeda Critical Care Monitor GE Healthcare Datex-Ohmeda Critical Care Monitor Comprehensive monitoring for the challenging Critical Care environment Critical Care monitor offers a flexible range of module frame options, displays and

More information

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

Quasi-Continuous Wave (CW) UV Laser Xcyte Series COMMERCIAL LASERS Quasi-Continuous Wave (CW) UV Laser Xcyte Series Key Features 355 nm outputs available Quasi-CW UV output Field-proven Direct-Coupled Pump (DCP ) TEM00 mode quality Light-regulated output

More information

R&S SMZ Frequency Multiplier Specifications

R&S SMZ Frequency Multiplier Specifications Test & Measurement Data Sheet 02.00 R&S SMZ Frequency Multiplier Specifications CONTENTS Definitions... 3 Specifications... 4 RF performance...4 Frequency...4 Level...4 Spectral purity...4 Connectors...5

More information

Dräger PSS 3000 Self Contained Breathing Apparatus

Dräger PSS 3000 Self Contained Breathing Apparatus Dräger PSS 3000 Self Contained Breathing Apparatus The Dräger PSS 3000 is a new generation of high performing breathing apparatus for firefighters. Combining comfort with exceptional pneumatic performance,

More information

Your personal anesthesia assistant DRÄGER PRIMUS

Your personal anesthesia assistant DRÄGER PRIMUS D-16232-2009 Your personal anesthesia assistant DRÄGER PRIMUS 02 DRÄGER PRIMUS An entire world of care You re playing a vital role in an increasingly complex healthcare system. Your job is to provide state-of-the-art

More information

GE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care

GE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care GE Healthcare Lullaby Warmer Because every baby deserves a high standard of care A confident choice for infant warming At GE Healthcare, we share your commitment to providing high quality care for all

More information

Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels

Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels Scanner Parts Document table Power cord Document cover Transparency unit (TPU) under lid Web Transparency unit (TPU) connector TPU indicator light e-mail Carriage and lamp (in the home position) USB port

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

digital quality control fail pass at your fingertips Smart Metrology Solutions.

digital quality control fail pass at your fingertips Smart Metrology Solutions. digital quality control fail pass µphase smartgage The clever innovation in digital metrology by FISBA, which lets you smarten up your quality management and economize your production processes, yet spares

More information

Bar code scanners CLV45x / CLV450 / Standard Density

Bar code scanners CLV45x / CLV450 / Standard Density ONLINE DATA SHEET www.mysick.com Bar code scanners CLV45x / CLV450 / Standard Density CLV450-0010 Bar code scanners CLV45x / CLV450 / Standard Density Model Name > CLV450-0010 Part No. > 1018556 At a glance

More information

Agila Ceiling Supply Unit Medical Supply Units

Agila Ceiling Supply Unit Medical Supply Units Agila Ceiling Supply Unit Medical Supply Units Featuring a wide range of configurations and options to choose from, the compact and highly ergonomic Dräger Agila family uses a minimum of precious care

More information

Count On Us For Your Safety Dräger at your service

Count On Us For Your Safety Dräger at your service 1 IMG_2390 D-39882-2011 Count On Us For Your Safety Dräger at your service Dräger at your service D-6638-2014_1_NEU 03 Contents Because every minute counts 4 Maximum safety from a single source 6 Quality

More information

Maxi Sky 2 Plus The complete ceiling lift system

Maxi Sky 2 Plus The complete ceiling lift system Maxi Sky 2 Plus The complete ceiling lift system A twin cassette ceiling lift system for patients up to 454 kg/1000 lbs with people in mind A versatile ceiling lift system for bariatric patients and the

More information

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments MCP 100 MCP 150 Modular Compact Polarimeters ::: Superior Optical Instruments Your Promise Anton Paar's Solution You have always made sure that your optically active substances meet all quality standards.

More information

GE Healthcare. The Giraffe Family. Helping make sick babies well

GE Healthcare. The Giraffe Family. Helping make sick babies well GE Healthcare The Giraffe Family Helping make sick babies well Visionary design. Revolutionary performance. Easy baby access. An unobstructed view. Reliable clinical performance. Technically sophisticated,

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

D-19673-2015. A cost effective monitor that meets your clinical needs VISTA 120

D-19673-2015. A cost effective monitor that meets your clinical needs VISTA 120 D-19673-2015 A cost effective monitor that meets your clinical needs VISTA 120 02 VISTA 120 03 Part of a complete departmental solution A comprehensive monitor at exceptional value D-3533-2011 Hospitals

More information

The Anesthesia Ventilator

The Anesthesia Ventilator The Anesthesia Ventilator Why is the piston replacing the bellows? For many decades, and millions of anesthetics, the bellows anesthesia ventilator has been a safe and effective clinical device. Indeed,

More information

PIEZOMETER AIRFLOW MEASURING RING

PIEZOMETER AIRFLOW MEASURING RING PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer

More information

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration Temperature Calibration Sources Highly accurate calibration equipment for pyrometers, thermal imaging cameras, radiometers, heatflux and spectrographic measurement sytems. Calibration sources are infrared

More information

TCS230 PROGRAMMABLE COLOR LIGHT TO FREQUENCY CONVERTER TAOS046 - FEBRUARY 2003

TCS230 PROGRAMMABLE COLOR LIGHT TO FREQUENCY CONVERTER TAOS046 - FEBRUARY 2003 High-Resolution Conversion of Light Intensity to Frequency Programmable Color and Full-Scale Output Frequency Communicates Directly With a Microcontroller Single-Supply Operation (2.7 V to 5.5 V) Power

More information

Photo Modules for PCM Remote Control Systems

Photo Modules for PCM Remote Control Systems Photo Modules for PCM Remote Control Systems Available types for different carrier frequencies Type fo Type fo TSOP183 3 khz TSOP1833 33 khz TSOP1836 36 khz TSOP1837 36.7 khz TSOP1838 38 khz TSOP184 4

More information

Basler racer. Line Scan Cameras. Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate

Basler racer. Line Scan Cameras. Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate Basler racer Line Scan Cameras Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate Flexible and easy integration, supported by a very compact design Low power consumption

More information

Barcode Reader Series BCL 31, BCL 32, BCL 34

Barcode Reader Series BCL 31, BCL 32, BCL 34 P R O D U C T I N F O R M A T I O N Barcode Reader Series BCL 31, BCL 32, BCL 34 BCL 31, BCL 32 and BCL 34: Barcode readers for universal use in conveyor and storage technology. 3 models: numerous advantages.

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

Movita Ceiling Supply Unit Medical Supply Units

Movita Ceiling Supply Unit Medical Supply Units Movita Ceiling Supply Unit Medical Supply Units Featuring a wide range of configurations and options to choose from, the versatile Dräger Movita family gives you enhanced loading capacity together with

More information

1. SAFETY INFORMATION

1. SAFETY INFORMATION RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line

More information

Agilent Cary 60 UV-Vis

Agilent Cary 60 UV-Vis Agilent Cary 60 UV-Vis Efficient. Accurate. Flexible. Specifications Introduction The Agilent Cary 60 UV-Vis spectrophotometer is efficient, accurate and flexible, and is designed to meet both current

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Remote Level Monitoring Unit

Remote Level Monitoring Unit Remote Level Monitoring Unit SPECIFICATIONS LASER MEASUREMENT Type InGasAs Laser Diode Wavelength 905 nm Beam Divergence 2.3 x 0.2 mrad (typical) Passive Range 0.5m to 150m Range to Reflective Target 0.5m

More information

DIODE PUMPED CRYSTALASER

DIODE PUMPED CRYSTALASER DIODE PUMPED CRYSTALASER Ultra-compact CW & Pulsed Turnkey Systems UV Visible to IR High Reliability High Stability High Efficiency TEMoo & SLM Low Noise Low Cost ULTRA-COMPACT DIODE-PUMPED CRYSTAL LASER

More information

2 1. 5 O pen F ram e Tou c h M on i t or

2 1. 5 O pen F ram e Tou c h M on i t or M TM G T- R TL 2 2 W- A 21.5" RE AR TOU C H MONITOR Trade SpA - Official European Distributor R eo O ar M ount R T L 1 7 3 2 1. 5 O pen F ram e Tou c h M on i t or R TL 2 2 W- A on i t or D at as h eet

More information

FIBER OPTIC A/B/C SWITCH (Latching)

FIBER OPTIC A/B/C SWITCH (Latching) JANUARY 2008 Model# SW1004A FIBER OPTIC A/B/C SWITCH (Latching) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day, 7 days

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

Effective light therapy. Philips lamps for therapeutic purposes. International Federation of Psoriasis Associations

Effective light therapy. Philips lamps for therapeutic purposes. International Federation of Psoriasis Associations Effective light therapy Philips lamps for therapeutic purposes International Federation of Psoriasis ssociations Proven technology for phototherapy s the world s largest manufacturer of lighting products

More information

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Bulletin -01E http://www.yokogawa.com/tm/... Visit our website to sign for e-mail updates Compact,

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Guaranteed specifications Design overview Double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometer (Agilent Cary

More information

HDO700 P FIBRE OPTIC TRANSMITTER

HDO700 P FIBRE OPTIC TRANSMITTER Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type

More information

Nederland België / Belgique

Nederland België / Belgique Cronus Brochure 2 Introduction Cronus: The first spectrometer and colorimeter in one The Cronus is world s first spectrocolorimeter combining a high en VIS spectrometer with a high speed XYZ colorimeter.

More information

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully

More information

EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size (8.5 11.7 inches [216 297 mm])

EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size (8.5 11.7 inches [216 297 mm]) Scanner Parts Start button power button (TPU) under lid IEEE 1394 port Scanner Specifications Basic Specifications Scanner type Photoelectric device Effective pixels USB port indicator light document cover

More information

Basler beat AREA SCAN CAMERAS. High-resolution 12 MP cameras with global shutter

Basler beat AREA SCAN CAMERAS. High-resolution 12 MP cameras with global shutter Basler beat AREA SCAN CAMERAS High-resolution 12 MP cameras with global shutter Outstanding price / performance ratio High speed through Camera Link interface Flexible and easy integration Overview Convincing

More information

DC Electronic Loads 8500 series

DC Electronic Loads 8500 series Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light

Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light generation from a semiconductor material, LED chip technology,

More information

Nardalert S3 Non-Ionizing Radiation Monitor

Nardalert S3 Non-Ionizing Radiation Monitor Patent Pending Non-Ionizing Radiation Monitor Field Replaceable Sensor Modules Color LCD Display Multi-Color Alarm LED s USB Interface for Data and Charging Interchangeable Lanyard or Belt Clips Comprehensive

More information

BPW34. Silicon PIN Photodiode VISHAY. Vishay Semiconductors

BPW34. Silicon PIN Photodiode VISHAY. Vishay Semiconductors Silicon PIN Photodiode Description The is a high speed and high sensitive PIN photodiode in a miniature flat plastic package. Its top view construction makes it ideal as a low cost replacement of TO-5

More information

WEATHER STATION FOR SOLAR FARM MONITORING

WEATHER STATION FOR SOLAR FARM MONITORING WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

USB/RS485 converter cable, complete

USB/RS485 converter cable, complete USB/RS485 converter cable, complete Instructions for use Contents Deutsch 1 Intended use 3 2 Safety 3 2.1 Safety information... 3 2.2 General information... 3 3 Description 5 3.1 Overview... 5 3.2 Connection

More information

8-Port PoE Network Switch

8-Port PoE Network Switch Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class

More information

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]

More information

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and

More information

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20 Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation

More information

SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)

SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING) SEPTEMBER 2008 Model# SW1035A Model# SW1036A SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING) CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

Transmissive Optical Sensor with Phototransistor Output

Transmissive Optical Sensor with Phototransistor Output TCST11. up to TCST23. Transmissive Optical Sensor with Phototransistor Output Description This device has a compact construction where the emitting-light sources and the detectors are located face-to-face

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Neonatal Warming Systems. Innovative technology for simpler neonatal care

Neonatal Warming Systems. Innovative technology for simpler neonatal care Neonatal Warming Systems Innovative technology for simpler neonatal care Inditherm have established themselves as experts in heating and warming solutions for a wide range of industries and applications.

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website www.riegl.com

RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website www.riegl.com Airborne Laser Scanner with Online Waveform Processing RIEGL VQ-48 high-accuracy ranging based on echo digitization and online waveform processing high laser repetition rate - fast data acquisition multiple

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass

More information

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH ENGLISH POS UNITS Installation and user guide Count, video recording and POS control unit INDEX 1 FUNCTIONALITY... 2 2 GENERAL CONSIDERATIONS... 4 3 CAMERAS INSTALLATION... 5 3.1 CAMERA TYPES... 5 3.2

More information

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET: SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

MINIMAT-EC-Servo Screwdriver Spindles

MINIMAT-EC-Servo Screwdriver Spindles Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range

More information

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement MAS 40 Mini-Array Spectrometer light measurement Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters

More information

IR Sensor Module for Reflective Sensor, Light Barrier, and Fast Proximity Applications

IR Sensor Module for Reflective Sensor, Light Barrier, and Fast Proximity Applications IR Sensor Module for Reflective Sensor, Light Barrier, and Fast Proximity Applications MECHANICAL DATA Pinning: = OUT, 2 = GND, 3 = V S 2 3 6672 APPLICATIONS Reflective sensors for hand dryers, towel or

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information. Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the

More information

Overview. Proven Image Quality and Easy to Use Without a Frame Grabber. Your benefits include:

Overview. Proven Image Quality and Easy to Use Without a Frame Grabber. Your benefits include: Basler runner Line Scan Cameras High-quality line scan technology meets a cost-effective GigE interface Real color support in a compact housing size Shading correction compensates for difficult lighting

More information