D Next-generation LED phototherapy NanoBlu 500
|
|
|
- Victoria Jackson
- 9 years ago
- Views:
Transcription
1 D Next-generation LED phototherapy NanoBlu 500
2 02 Is there a powerful phototherapy device that s really compact? D
3 03 BETTER TREaTMENTS SuPPoRT BETTER outcomes The effective treatment of hyperbilirubinemia (jaundice) is crucial to newborn health. Some 60% of normal newborns become clinically jaundiced sometime during the first week of life. 1 If not treated in time, jaundice can cause severe physical damage to the child. In effect, the better the jaundice treatment, the better the outcome. NEXT-GENERaTIoN LED PHoToTHERaPY At Dräger, our focus on minimal stress therapies has led to the development of jaundice screening and therapeutic solutions that are non-invasive, simple-to-use, and highly effective. Designed to meet AAP guidelines for intensive phototherapy, the Dräger NanoBlu 500 is a compact, powerful phototherapy unit for the treatment of hyperbilirubinemia in newborn infants. With light-emitting diodes (LEDs) that emit blue light in the nm spectrum, NanoBlu 500 is aligned with the peak absorption wavelength (450 nm) at which bilirubin is broken down. 2 EaSY on THE BaBY, EMPoWERING FoR THE CaREGIVER Innovative technology enables the NanoBlu 500 to evenly distribute high irradiance with only five LEDs and you can adjust irradiance levels for the specific needs of each infant. An optional integrated radiometer with optical sensor enables you to regularly monitor the light intensity of the phototherapy as recommended by most hospital protocols. In addition, you can automatically document irradiance measurements and download that information to a computer and/or printer for a more complete record. 1 Maisels, M.J. and McDonagh, A.F. Phototherapy for Neonatal Jaundice. New England Journal of Medicine, volume 358, number 9, February 28, 2008, pages Vreman HJ, et al. Light-emitting diodes: a novel light source for phototherapy. Pediatric Research. 1998; 44(5):
4 4 Customizable & connected phototherapy Control & Innovation Control specific irradiance level from 10 to 100%: allows you to accurately match your hospital protocol requirements Access full menu from one interface: provides fast access to device settings, maintenance and calibration, time and calendar, device usage data Generate reports containing hour counter, time of exposure, calendar/clock, and stored irradiance files: lets you document the performance of the phototherapy session Effective application High intensity levels Provides optimal spectrum levels Distributes light uniformly across body of infant Does not require touching the baby or placing an additional device directly in their proximity, which is important for very low birth weight infants D Practicality Trolley or hood-mount option adds flexibility to the work space around the baby Highly flexible and adjustable positioning on babies in incubators or warmers Optional integrated radiometer with optical sensor to ensure optimal performance Long-lasting LED technology and low power consumption compared to fluorescent lights
5 5 Dräger NanoBlu 500 is the first line of defense for the effective treatment of jaundice. It delivers the key criteria for effective phototherapy: the right spectrum of light, at the right intensity, to as much of the baby s skin as possible in a compact, easyto-use package. 50 cm (19.69 ) 40 cm (15.75 ) 30 cm (11.81 ) 14 cm (5.51 ) µw/cm 2 -nm 16 cm (6.3 ) µw/cm 2 -nm 18 cm (7.09 ) µw/cm 2 -nm The Dräger NanoBlu 500 includes five LEDs that provide a high level of blue-spectrum light. They are composed of an Indium and Gallium Nitride (InGaN) semiconductor structure, which enables the use of fewer LEDs and eliminates ultraviolet and infrared filters. The light provides a large ellipse of medium-intensity light coverage, allowing for more light to reach the infant.
6 6 TECHNICaL DaTa Device classification Protection class of trolley mount Class I, continuous operation equipment without applied parts Protection class of hood mount Class II, continuous operation equipment without applied parts Ingress of liquids IPX0, regular equipment - not waterproof Classification in accordance with EU Directive Device class IIa 93/42/EEC Appendix IX UMDNS code/gmdn code 17516/34477 Power Requirements 100 V~ to 240 V~, 50/60 Hz, 50 VA, 1.5 A Physical specifications Dräger nanoblu 500 hood Mount Width Depth Height Net weight Weight when packaged 11.6 cm (4.57 in) 23.0 cm (9.06 in) 5.0 cm (1.97 in) 1.0 kg (2.2 lb) 3.0 kg (6.6 lb) Dräger nanoblu 500 trolley Mount Width Depth Height Net weight Weight when packaged 50.0 cm (19.69 in) 50.0 cm (19.69 in) cm to cm (39.37 in to in) 9.0 kg (19.8 lb) 14.0 kg (30.9 lb) irradiance at 30 cm (11.81 in) Illuminated area fulcrum Minimum 40 μw/cm 2 nm (+10 %) Illuminated area dimensions 40 cm by 37 cm (15.75 in by in) Irradiance adjustment band 10 % to 100 % of maximum irradiance (+10 %) Irradiance adjustment increment at every 10 % optical sensor/radiometer Measurement band Resolution Reading accuracy 0 μw/cm 2 nm to 200 μw/cm 2 nm 0.1 μw/cm 2 nm ±2 μw/cm 2 nm Noise < 52 dba electrical specifications Power Supply Output voltage Output power Input voltage Operating frequency Universal input power supply 12 VDC 50 W VAC 50/60 Hz
7 7 environmental RequiReMents temperature range Operating Storage 18 to 28 C (64.4 to 82.4 F) -20 to 60 C (-4 to 140 F) Relative humidity Operating Storage 10 % to 95 % (non condensing) 10 % to 95 % (non condensing) atmospheric Pressure Operating Storage 700 hpa to 1060 hpa 500 hpa to 1060 hpa Data transmission RS-232 serial port Standard UART protocol Bits per second 9600 bps Data bits 8 Parity None Stop bits 1 Flow control None standards IEC :1988 Medical Electrical Equipment, Part 1: General Requirements for Safety UL st Edition, 2006 Medical Electrical Equipment, Part 1: General Requirements for Safety CAN/CSA-C22.2 No M90, 2005 IEC :2000 Medical Electrical Equipment, Part 2: Particular requirements for the safety of infant phototherapy equipment IEC :2001 Medical electrical equipment -- Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests NanoBlu 500 offers a variety of mounting options.
8 Corporate headquarters Drägerwerk AG & Co. KGaA Moislinger Allee Lübeck, Germany USA Draeger Medical, Inc Quarry Road Telford, PA , USA Tel Toll-free Fax CANADA Draeger Medical Canada Inc. 120 East Beaver Creek Road Suite 104 Richmond Hill Ontario L4B 4V1, Canada Tel Toll-free Fax Manufactured for: Draeger Medical Systems, Inc. Telford, PA 18969, USA The quality management system at Draeger Medical Systems, Inc. is certified according to ISO and ISO Marketing Communications SL Neo Printed in the United States Chlorine-free environmentally compatible Subject to modifications 2012 Drägerwerk AG & Co. KGaA
Sample Usage Protocol Jaundice Meter JM-105
D-94164-2013 Sample Usage Protocol Jaundice Meter JM-105 This Sample Usage Protocol is provided as a template for creating a facility or department-specific protocol for using the Dräger Jaundice Meter
D-94164-2013. Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105
D-94164-2013 Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105 2 Assessing jaundice risk without the trauma D-94313-2013 D-7346-2009 While neonatal jaundice or hyperbilirubinemia
D-9282-2009. Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM
D-9282-2009 Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM 02 Alarm Management System The central gas supply is one of the hospital s life support systems, and as such is subject to special
The bridge to more efficient care PONTA SUPPLY BEAMS
MT-4159-2007 The bridge to more efficient care PONTA SUPPLY BEAMS 02 PONTA SUPPLY BEAMS more versatile MT-4056-2007 MT-3978-2007 MT-3965-2007 MT-3987-2007 Uniting improved care with individual flexibility
The column to efficient care DRÄGER GEMINA DUO
MT-0798-2008 The column to efficient care DRÄGER GEMINA DUO 02 Dräger a century of care competence Today, hospitals are under increased pressure to provide state-of-the-art care with less staff and on
Oxylog 3000 plus Emergency & Transport Ventilation
Oxylog 3000 plus Emergency & Transport Ventilation Offering high ventilation performance with features such as AutoFlow integrated capnography and non-invasive Ventilation, the compact and robust Oxylog
Polaris 5xx/7xx Medical Lights and Video
Polaris 5xx/7xx Medical Lights and Video Without light, surgery just isn t possible. Sufficient light is one of the fundamental requirements for the operating theatre. The Polaris lights were designed
Dräger PARAT Escape Hoods
Dräger PARAT Escape Hoods Airborne toxins present an immediate danger to the health of a workforce. When environments turn toxic, a fast, safe escape is crucial. Dräger PARAT Escape Hoods are designed
Infinity Central Monitoring and Remote Access Solutions
Infinity Central Monitoring and Remote Access Solutions Reaching beyond the point of care Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care At Dräger, we re committed
Dräger Alcotest 9510 Evidential Alcohol Measuring Device
Dräger Alcotest 9510 Evidential Alcohol Measuring Device The Dräger Alcotest 9510 is an advanced breath alcohol measuring instrument for evidential applications. It is designed to comply with national
Anesthesia Information Management DRÄGER INNOVIAN ANESTHESIA
D-24993-2010 Anesthesia Information Management DRÄGER INNOVIAN ANESTHESIA D-24994-2010 Imagine a solution that puts the focus back on the patient by automating the anesthesia patient record giving you
Bar Code Reader Series BCL 20 A flexible reader for a variety of applications
Bar Code Reader Series BCL 20 A flexible reader for a variety of applications PRODUCT INFORMATION The benchmark for flexibility. Laser scanners of the BCL 20 series as variable as your requirements demand.
Dräger Globe-Trotter GT5400 Neonatal Transport
Dräger Globe-Trotter GT5400 Neonatal Transport The Globe-Trotter GT5400 is the result of Dräger s ongoing commitment to developing a safer and more stable neonatal transport system. This system meets global
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying
Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying Concentrated liquid cleaning agent for manual cleaning of respiratory masks, respiratory protection equipment, diving apparatus
Guideline Laser Series
Guideline Laser Series Highly visible alignment laser for visually demanding surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)
Dräger X-dock Release Notes Software-Update 01.07.00 and Manager Software 1.7.0
Supported operating system (X-dock Manager) Windows 7 Windows 8 Windows Server 2008 R2 Windows Server 2012 R2 Supported firmware versions (X-dock Manager) X-am 2000: > = v6.0 X-am 2500/5x00: > = v6.6 Pac
D-1188-2009. Move life-critical patient data on your existing network INFINITY ONENET
D-1188-2009 Move life-critical patient data on your existing network INFINITY ONENET 02 One Network rather than two MT-1351-2007 Patient monitoring data is life-critical. That s why hospitals have traditionally
Moving beyond telemetry INFINITY M300
D-19757-2009 Moving beyond telemetry INFINITY M300 02 MT-4187-2006 MT-4488-2006 D-19730-2009 03 Transforming telemetry into patient-worn monitoring From the standpoint of patient monitoring, today s busy
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust
Datex-Ohmeda Critical Care Monitor
GE Healthcare Datex-Ohmeda Critical Care Monitor Comprehensive monitoring for the challenging Critical Care environment Critical Care monitor offers a flexible range of module frame options, displays and
Quasi-Continuous Wave (CW) UV Laser Xcyte Series
COMMERCIAL LASERS Quasi-Continuous Wave (CW) UV Laser Xcyte Series Key Features 355 nm outputs available Quasi-CW UV output Field-proven Direct-Coupled Pump (DCP ) TEM00 mode quality Light-regulated output
R&S SMZ Frequency Multiplier Specifications
Test & Measurement Data Sheet 02.00 R&S SMZ Frequency Multiplier Specifications CONTENTS Definitions... 3 Specifications... 4 RF performance...4 Frequency...4 Level...4 Spectral purity...4 Connectors...5
Dräger PSS 3000 Self Contained Breathing Apparatus
Dräger PSS 3000 Self Contained Breathing Apparatus The Dräger PSS 3000 is a new generation of high performing breathing apparatus for firefighters. Combining comfort with exceptional pneumatic performance,
Your personal anesthesia assistant DRÄGER PRIMUS
D-16232-2009 Your personal anesthesia assistant DRÄGER PRIMUS 02 DRÄGER PRIMUS An entire world of care You re playing a vital role in an increasingly complex healthcare system. Your job is to provide state-of-the-art
GE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care
GE Healthcare Lullaby Warmer Because every baby deserves a high standard of care A confident choice for infant warming At GE Healthcare, we share your commitment to providing high quality care for all
Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels
Scanner Parts Document table Power cord Document cover Transparency unit (TPU) under lid Web Transparency unit (TPU) connector TPU indicator light e-mail Carriage and lamp (in the home position) USB port
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
digital quality control fail pass at your fingertips Smart Metrology Solutions.
digital quality control fail pass µphase smartgage The clever innovation in digital metrology by FISBA, which lets you smarten up your quality management and economize your production processes, yet spares
Bar code scanners CLV45x / CLV450 / Standard Density
ONLINE DATA SHEET www.mysick.com Bar code scanners CLV45x / CLV450 / Standard Density CLV450-0010 Bar code scanners CLV45x / CLV450 / Standard Density Model Name > CLV450-0010 Part No. > 1018556 At a glance
Agila Ceiling Supply Unit Medical Supply Units
Agila Ceiling Supply Unit Medical Supply Units Featuring a wide range of configurations and options to choose from, the compact and highly ergonomic Dräger Agila family uses a minimum of precious care
Count On Us For Your Safety Dräger at your service
1 IMG_2390 D-39882-2011 Count On Us For Your Safety Dräger at your service Dräger at your service D-6638-2014_1_NEU 03 Contents Because every minute counts 4 Maximum safety from a single source 6 Quality
Maxi Sky 2 Plus The complete ceiling lift system
Maxi Sky 2 Plus The complete ceiling lift system A twin cassette ceiling lift system for patients up to 454 kg/1000 lbs with people in mind A versatile ceiling lift system for bariatric patients and the
MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments
MCP 100 MCP 150 Modular Compact Polarimeters ::: Superior Optical Instruments Your Promise Anton Paar's Solution You have always made sure that your optically active substances meet all quality standards.
GE Healthcare. The Giraffe Family. Helping make sick babies well
GE Healthcare The Giraffe Family Helping make sick babies well Visionary design. Revolutionary performance. Easy baby access. An unobstructed view. Reliable clinical performance. Technically sophisticated,
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
D-19673-2015. A cost effective monitor that meets your clinical needs VISTA 120
D-19673-2015 A cost effective monitor that meets your clinical needs VISTA 120 02 VISTA 120 03 Part of a complete departmental solution A comprehensive monitor at exceptional value D-3533-2011 Hospitals
The Anesthesia Ventilator
The Anesthesia Ventilator Why is the piston replacing the bellows? For many decades, and millions of anesthetics, the bellows anesthesia ventilator has been a safe and effective clinical device. Indeed,
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration
Temperature Calibration Sources Highly accurate calibration equipment for pyrometers, thermal imaging cameras, radiometers, heatflux and spectrographic measurement sytems. Calibration sources are infrared
TCS230 PROGRAMMABLE COLOR LIGHT TO FREQUENCY CONVERTER TAOS046 - FEBRUARY 2003
High-Resolution Conversion of Light Intensity to Frequency Programmable Color and Full-Scale Output Frequency Communicates Directly With a Microcontroller Single-Supply Operation (2.7 V to 5.5 V) Power
Photo Modules for PCM Remote Control Systems
Photo Modules for PCM Remote Control Systems Available types for different carrier frequencies Type fo Type fo TSOP183 3 khz TSOP1833 33 khz TSOP1836 36 khz TSOP1837 36.7 khz TSOP1838 38 khz TSOP184 4
Basler racer. Line Scan Cameras. Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate
Basler racer Line Scan Cameras Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate Flexible and easy integration, supported by a very compact design Low power consumption
Barcode Reader Series BCL 31, BCL 32, BCL 34
P R O D U C T I N F O R M A T I O N Barcode Reader Series BCL 31, BCL 32, BCL 34 BCL 31, BCL 32 and BCL 34: Barcode readers for universal use in conveyor and storage technology. 3 models: numerous advantages.
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Movita Ceiling Supply Unit Medical Supply Units
Movita Ceiling Supply Unit Medical Supply Units Featuring a wide range of configurations and options to choose from, the versatile Dräger Movita family gives you enhanced loading capacity together with
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz
Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line
Agilent Cary 60 UV-Vis
Agilent Cary 60 UV-Vis Efficient. Accurate. Flexible. Specifications Introduction The Agilent Cary 60 UV-Vis spectrophotometer is efficient, accurate and flexible, and is designed to meet both current
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Remote Level Monitoring Unit
Remote Level Monitoring Unit SPECIFICATIONS LASER MEASUREMENT Type InGasAs Laser Diode Wavelength 905 nm Beam Divergence 2.3 x 0.2 mrad (typical) Passive Range 0.5m to 150m Range to Reflective Target 0.5m
DIODE PUMPED CRYSTALASER
DIODE PUMPED CRYSTALASER Ultra-compact CW & Pulsed Turnkey Systems UV Visible to IR High Reliability High Stability High Efficiency TEMoo & SLM Low Noise Low Cost ULTRA-COMPACT DIODE-PUMPED CRYSTAL LASER
2 1. 5 O pen F ram e Tou c h M on i t or
M TM G T- R TL 2 2 W- A 21.5" RE AR TOU C H MONITOR Trade SpA - Official European Distributor R eo O ar M ount R T L 1 7 3 2 1. 5 O pen F ram e Tou c h M on i t or R TL 2 2 W- A on i t or D at as h eet
FIBER OPTIC A/B/C SWITCH (Latching)
JANUARY 2008 Model# SW1004A FIBER OPTIC A/B/C SWITCH (Latching) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day, 7 days
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
Effective light therapy. Philips lamps for therapeutic purposes. International Federation of Psoriasis Associations
Effective light therapy Philips lamps for therapeutic purposes International Federation of Psoriasis ssociations Proven technology for phototherapy s the world s largest manufacturer of lighting products
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Bulletin -01E http://www.yokogawa.com/tm/... Visit our website to sign for e-mail updates Compact,
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Guaranteed specifications Design overview Double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometer (Agilent Cary
HDO700 P FIBRE OPTIC TRANSMITTER
Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type
Nederland België / Belgique
Cronus Brochure 2 Introduction Cronus: The first spectrometer and colorimeter in one The Cronus is world s first spectrocolorimeter combining a high en VIS spectrometer with a high speed XYZ colorimeter.
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size (8.5 11.7 inches [216 297 mm])
Scanner Parts Start button power button (TPU) under lid IEEE 1394 port Scanner Specifications Basic Specifications Scanner type Photoelectric device Effective pixels USB port indicator light document cover
Basler beat AREA SCAN CAMERAS. High-resolution 12 MP cameras with global shutter
Basler beat AREA SCAN CAMERAS High-resolution 12 MP cameras with global shutter Outstanding price / performance ratio High speed through Camera Link interface Flexible and easy integration Overview Convincing
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light
Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light generation from a semiconductor material, LED chip technology,
Nardalert S3 Non-Ionizing Radiation Monitor
Patent Pending Non-Ionizing Radiation Monitor Field Replaceable Sensor Modules Color LCD Display Multi-Color Alarm LED s USB Interface for Data and Charging Interchangeable Lanyard or Belt Clips Comprehensive
BPW34. Silicon PIN Photodiode VISHAY. Vishay Semiconductors
Silicon PIN Photodiode Description The is a high speed and high sensitive PIN photodiode in a miniature flat plastic package. Its top view construction makes it ideal as a low cost replacement of TO-5
WEATHER STATION FOR SOLAR FARM MONITORING
WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
USB/RS485 converter cable, complete
USB/RS485 converter cable, complete Instructions for use Contents Deutsch 1 Intended use 3 2 Safety 3 2.1 Safety information... 3 2.2 General information... 3 3 Description 5 3.1 Overview... 5 3.2 Connection
8-Port PoE Network Switch
Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class
Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)
SEPTEMBER 2008 Model# SW1035A Model# SW1036A SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING) CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
Transmissive Optical Sensor with Phototransistor Output
TCST11. up to TCST23. Transmissive Optical Sensor with Phototransistor Output Description This device has a compact construction where the emitting-light sources and the detectors are located face-to-face
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Neonatal Warming Systems. Innovative technology for simpler neonatal care
Neonatal Warming Systems Innovative technology for simpler neonatal care Inditherm have established themselves as experts in heating and warming solutions for a wide range of industries and applications.
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website www.riegl.com
Airborne Laser Scanner with Online Waveform Processing RIEGL VQ-48 high-accuracy ranging based on echo digitization and online waveform processing high laser repetition rate - fast data acquisition multiple
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH
ENGLISH POS UNITS Installation and user guide Count, video recording and POS control unit INDEX 1 FUNCTIONALITY... 2 2 GENERAL CONSIDERATIONS... 4 3 CAMERAS INSTALLATION... 5 3.1 CAMERA TYPES... 5 3.2
SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
R&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
MINIMAT-EC-Servo Screwdriver Spindles
Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range
We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement
MAS 40 Mini-Array Spectrometer light measurement Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters
IR Sensor Module for Reflective Sensor, Light Barrier, and Fast Proximity Applications
IR Sensor Module for Reflective Sensor, Light Barrier, and Fast Proximity Applications MECHANICAL DATA Pinning: = OUT, 2 = GND, 3 = V S 2 3 6672 APPLICATIONS Reflective sensors for hand dryers, towel or
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
Overview. Proven Image Quality and Easy to Use Without a Frame Grabber. Your benefits include:
Basler runner Line Scan Cameras High-quality line scan technology meets a cost-effective GigE interface Real color support in a compact housing size Shading correction compensates for difficult lighting
