2 TECHNICAL SPECIFICATION OF RECORDERS Leads EC-12R EC-12RM EC- 12R/S EC-12S EC-12R EC- 12RM EC-12R/S EC-12S Standard 12-channel (10 electrodes): I, II, II, avr, avl, avf, V1, V2, V3, V4, V5, V6 NEHB 6-channel (4 electrodes) ): I, II, II, avr, avl, avf Resting ECG (Windows) With USB-02/A or /B interface With supplied interface Stress ECG (Windows) - With USB-02/A or /B - With interface Resting ECG (Android) Resting ECG (ios) BP measurement method - BP measurement range - BP measurement accurary Auscultatory QRS-gated Hgmm - - Auscultatory QRS-gated Hgmm - ± 3 mmhg - ± 3 mmhg Wireless connection Bluetooth 2.0 IEEE g Patient protection Power supply Dynamic interval DC offset range Frequency response Sampling rate (recorder) Transmission rate Sampling rate (sofware) A/D resolution Input impedance Size EN (IEC-601-1), CF type 2 x 1,2 V rechargeable batteries (or 2 x 1.5 V AA alkaline battery) Exchangeable during recording. ±20 mv ±1000 mv 0.05 Hz 150Hz 1024 Hz 512 Hz 1000 Hz 16 bit 100 MΩ 125 x 70 x 33 mm Weight ca. 110 g ca. 200 g ca. 110 g ca. 200 g On/off switch Option + Option - Option + Option -
3 Specifications of Cardiospy (Windows) software BASIC FUNCTIONS OF SOFTWARE Common database for all Labtech system Acquire Patient ID from barcode reader DATABASE FUNCTIONS Record recycle bin function Search records System log Local database, Network database: Microsoft SQL Server database, SQLite database Filter records Different date format Acquire Patient ID using magnetic card reader Medical record for patients Import export records Password protected software starting Access control Import export records by date BASIC FUNCTIONS Automatic update Normal and MSI install Full screen mode HIS integrations: GDT, DICOM Two display mode Cubios HRV export MODALITY WORKLIST, Cardiospy SDK FTP integration function AHA / IEC electrode placement PRINT AND EXPORT FUNCTIONS Report printing and exporting Automatic print Selectable reports Color and Black and white Contrast settings Resizable resolution reports Customizable company logo Automatic diagnosis Custom report Adjustable paper speed and amplitude Import /Export settings Export ECG data to CSV, SCP, Dat format Export QRS data Export N-N intervals Export R-R intervals REST SOFTWARE FUNCTIONS 5, 10, 20 sec and long ECG Rhythm curves Lead-off warning record Precise QRS classification Store the Indication and medication of the patient Smoothing, baseline, mains filters Arrhythmia analysis QRS frontal axis Full Disclosure ECG recording Paper speed: 5-12, Amplitude: 2,5, BMI and BMI prime 200 mm/s mm/mv Automatic diagnosis Average view ECG contrast Milimeter paper settings Display channels: 3, 6, 12, additionally: Cabrera, Custom
4 STRESS SOFTWARE FUNCTIONS Lead-off warning Precise QRS classification colour-coded ST level, slope and ST loop graphs Store the Indication and SAECG Smoothing, baseline, mains medication of the patient filters MET and VO2 computation HR, BP, LOAD, MET graphs Customizable alarm and stop criteria Ergometer and treadmill Show T-wave deviation: QT, QTc Vectorcardiography in stresscontinuous database trends test Arrhythmia analysis Weber amd Morris function Bayes theorem in the analysis classification Duke-nomogram Borg rank QRS frontal axis Exercise and condition plan Pacemaker detection Paper speed: 5-12, mm/s Amplitude: 2,5, Gender and age-specific ECG Full Disclosure ECG recording mm/mv analysis software Modifiable protocols under standard stress protocols, manual blood pressure measure Load custom protocols Speed measure km/h and mph BMI and BMI prime Adjustable infoboxes Rhythm curves Templates analysis Event screen QT, QTc, QT% QRS Axis Ectopic rate Average view ECG contrast Milimeter paper settings Display channels: 3, 6, 12, additionally: Cabrera, Custom COMPUTER MINIMUM CONFIGURATION Processor RAM Graphics card Display HDD Interface Printer minimum: Core 2 Duo or better recommended: Intel Core i3 or better (Sandy Bridge or newer architecture) minimum: 2 GB; recommended: 6 GB DirectX 10 compatible, min. 128 MB video memory minimum: min. 1280x800 resolution recommended: dual 22 monitor 1920 x 1080 resolution (Full HD) 200 GB (SATA II or newer recommended) 1 USB port for the USB-02 or dongle 1 USB port for the printer Laser (printing speed: page/min, color printer recommended) Windows XP SP 3 (32-bit only) Windows Vista, Windows 7, Windows 8, Windows 8.1 (32-bit or 64-bit versions) *Windows XP is no longer supported by Microsoft. Labtech provides only limited support for previously installed systems.
5 Specifications of Cardiospy Mobile (Android, ios) software Software specification Simple, user friendly software with multiple functions Precise QRS classification Built-in ST analysis Baseline; Main; Smoothing filter Real-time ECG display 1x3; 2x3; 1x6; 2x6; 1x12 leads view Sending JPEG reports in , and telemedicine support Record uploading to Labtech NetEcg Server Recod viewer ECG amplitude, time measurement Patients database Continuous updating and developments Bluetooth communication s and long ECG recording Lead-off warning (Indication of disconnected electrodes) Language: English ANDROID MINIMUM CONFIGURATION Android 4.0 (Ice Cream Sandwich) or newer CPU ARM or Intel architecture, min. 2 core, 1 GHz RAM minimum: 1 GB; recommended: 2 GB Bluetooth Bluetooth interface with serial port profile enabled Internet tethering or external Mi-Fi hotspot Display minimum: 1024 x 768 or 1280 x 720 ios SUPPORTED DEVICES Phones only tablets + Cellular tablets Display 7.0 or newer, newest version recommended iphone 4, 4S, 5, 5C, 5S: supported with internal or external hotspot iphone 6, 6 Plus, 6S, 6S Plus: supported with external hotspot only ipad 2, 3, 4, ipad Air 1, 2, ipad Mini 1, 2, 3, 4, ipad Pro: supported with external hotspot only ipad 2, 3, 4, ipad Air 1, ipad Mini 1, 2: supported with internal or external hotspot ipad Air 2, ipad Mini 3, 4, ipad Pro: supported with external hotspot only Display size of iphone 4, 4S, 5, 5C and 5S is not optimal for the display of 12-channel ECG, only 3-6 channels are visible without overlapping
touchecg Reference Markets your profession, our mission
touchecg touchecg is a 12-lead resting electrocardiograph based on a high-resolution, touch-screen tablet pc and clickecgbt acquisition unit, communicating via Bluetooth technology. The system can also
LABTECH LTD. 4th. Vág street Debrecen 4031 Hungary. Address. [email protected]. E-mail. Phone +36-52-310-128. Fax +36-52-412-023
LABTECH LTD. Address E-mail 4th. Vág street Debrecen 4031 Hungary [email protected] Phone +36-52-310-128 Fax +36-52-412-023 LABTECH LTD. MADE IN HUNGARY INTRODUCTION CARDIOSPY MOBILE 1 Introduction Dear
PVTC Technical Requirements
About the Installation Scenarios This document describes the minimum hardware requirements to install the Pearson VUE Testing (VTS) software in a Pearson VUE Authorized Test Center. The VTS software may
INNOC. Innocare-T. Innomed. Innomed s intensive and anesthesiological monitor system can be used both as a transport or bed-side care unit
Innocare-T Portable patient monitoring system INNOC Innomed s intensive and anesthesiological monitor system can be used both as a transport or bed-side care unit The most modern technology Large color
Installation Guide v1.11 and Higher
Progeny Imaging Installation Guide v1.11 and Higher 00-02-1604 Rev. D ECN P3483 Revision Date: 6/2/2015 0120 Contents 1. About This Manual... 3 Text Conventions... 3 2. Welcome to Progeny Imaging... 4
Rest ECG www.norav.com
www.norav.com Rest ECG 12 lead ECG Comprehensive solutions for Mobile, Table Top or Hand Held ECG. No computer experience is needed, due to the system's user friendly software, which allows even first-time
Davis Medical Electronics
Accelerate your workflow Holter Monitoring System, Release 2.9 DigiTrak XT Designed to meet your every need Philips Holter Monitoring System is designed to simplify life for you and your patients. It provides
Microsoft SQL Server 2008 R2 Express.
System s System s Note: Disk compression must not be used. Business/Professional Edition Database Server (with integrated client and NVR) The maximum number of clients is 9 (including Web clients). The
DMS-10101, Computer Equipment
Overview Effective dates: September 2005 - August 2006. This Specification describes the procedures for providing desktop microcomputers, laptop microcomputers, printers, and internet service for use on
For designers and engineers, Autodesk Product Design Suite Standard provides a foundational 3D design and drafting solution.
Autodesk Product Design Suite Standard 2013 System Requirements Typical Persona and Workflow For designers and engineers, Autodesk Product Design Suite Standard provides a foundational 3D design and drafting
CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.
CardioCard System Product Specification and Sample Reports CardioCard PC-Based ECG CardioCard PC-Based Stress CardioCard PC-Based Holter Table Lorem of Contents Ipsum iii 1 i Table of Contents 1 Advanced
Practice Management Installation Guide. Requirements/Prerequisites: Workstation Requirements. Page 1 of 5
Practice Management Installation Guide Your computers must meet the Workstation, Server and Network Requirements (see below for specifics). These requirements will ensure that Practice Management will
Grant Management. System Requirements
January 26, 2014 This is a publication of Abila, Inc. Version 2014.x 2013 Abila, Inc. and its affiliated entities. All rights reserved. Abila, the Abila logos, and the Abila product and service names mentioned
Video Conferencing System Requirements
Video Conferencing System Requirements TrueConf system and network requirements depend on chosen video conferencing mode and applied video quality. Video resolution and frame rate are selected automatically
AT&T Connect System Requirements for End Users v9.5. March 2013
AT&T Connect System Requirements for End Users v9.5 March 2013 Product: AT&T Connect Title: System Requirements for End Users Version: v9.5 Publication date: 3/6/2013 Reference number: CONSYSCL01012 Revision
Autodesk Building Design Suite 2012 Standard Edition System Requirements... 2
Autodesk Building Design Suite 2012 System Requirements Autodesk Building Design Suite 2012 Standard Edition System Requirements... 2 Autodesk Building Design Suite 2012 Premium Edition System Requirements...
Instruction manual. testo easyheat Configuration and Analysis software
Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of
Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.
Important Please read this User s Manual carefully to familiarize yourself with safe and effective usage. About This Manual This manual describes how to install and configure RadiNET Pro Gateway and RadiCS
OMNI TOUCH SCREEN PATIENT MONITOR
OMNI TOUCH SCREEN PATIENT MONITOR OMNI n Intuitive Designed for a fast paced work environment, the Infinium Omni series patient monitors offers an extremely simple and adaptable user interface. The Omni
Installation Manual. TruTops products Part 1: System requirements. Version 2.10
Installation Manual TruTops products Part 1: System requirements Version 2.10 Installation manual TruTops products Part 1: System requirements Edition: 2016-04-12 Version 2.10 C332en Order information
Sage Grant Management System Requirements
Sage Grant Management System Requirements You should meet or exceed the following system requirements: One Server - Database/Web Server The following system requirements are for Sage Grant Management to
VitalJacket SDK v1.0.03 Technical Specifications
VitalJacket SDK v1.0.03 Technical Specifications Edíficio Olympus I Page2 LEGAL NOTICE AND DISCLAIMER ATENTION: Although VitalJacket is a certified medical device, its developer version is NOT certified
Labtech Ltd. Company Profile
Labtech Ltd. Company Profile Labtech Ltd is an innovating Hungarian company established in 1990, developing and manufacturing PC-based ambulatory ECG Holter and Resting and Stress Test Systems. Our company
VitalJacket SDK v1.0.07 Technical Specifications
VitalJacket SDK v1.0.07 Technical Specifications Edíficio Olympus II LEGAL NOTICE AND DISCLAIMER ATENTION: Although VitalJacket is a certified medical device, its developer version is NOT certified for
If you are working with the H4D-60 or multi-shot cameras we recommend 8GB of RAM on a 64 bit Windows and 1GB of video RAM.
Phocus 2.7.6 Windows read-me December 5 2013 Installation To install Phocus, run the installation bundle called Phocus 2.7.6 Setup.exe. This bundle contains Phocus, Hasselblad Device Drivers, Microsoft.NET
1 DVR 670 Series firmware version 2.1.2 (date 2014-06-17)
Video Recorder 670 Series 1 DVR 670 Series firmware version 2.1.2 (date 2014-06-17) File name: 600rtseries_2.1.2_140617.bin - When a unit detects a HDD error, the DVR will automatically reboot so that
Section 28 16 00 Intrusion Detection. FiberPatrol RAMS (FPRAMS) Remote Alarm Management System Software Version 4
Section 28 16 00 Intrusion Detection FiberPatrol RAMS (FPRAMS) Remote Alarm Management System Software Version 4 Architectural and Engineering Specifications TECHNICAL SPECIFICATIONS DIVISION 28 ELECTRONIC
USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p
USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p StarTech ID: USB32HDEH3 The USB32HDEH3 USB 3.0 to HDMI Adapter turns a USB 3.0 port
Elo PayPoint for Windows All-in-One Point-of-Sale Platform
PRODUCT OVERVIEW Everything You Need Style You Don t Need to Hide 3 Year Warranty Elo PayPoint for Windows All-in-One Point-of-Sale Platform All-in-one, the Elo PayPoint is your register, cash drawer,
Abila Grant Management. System Requirements
Abila Grant Management This is a publication of Abila, Inc. Version 2015 2014 Abila, Inc. and its affiliated entities. All rights reserved. Abila, the Abila logos, and the Abila product and service names
TruVision Navigator v6
Video Surveillance Navigator v6 License-free video management system OVERVIEW Navigator v6.0 from Interlogix, represents the latest advancement in video management software. This license-free video management
Versatile Applications
Versatile Applications Distinguished Features Blu-ray enriches the Applications IEI Quick Mounting Technology Specifications Ordering Information Packing List Optional Mounting Kits Versatile Applications
Smart Anytime, Safe Anywhere. Climax Home Portal Platform. Envisage and Enable a Connected Future
Smart Anytime, Safe Anywhere Climax Home Portal Platform Envisage and Enable a Connected Future Climax Home Portal Platform An IP/GPRS-Based Solution to Deliver Smart Home and Mobile Control Services Reliable
OPTAC Fleet Viewer. Instruction Manual
OPTAC Fleet Viewer Instruction Manual Stoneridge Limited Claverhouse Industrial Park Dundee DD4 9UB Help-line Telephone Number: 0870 887 9256 E-Mail: [email protected] Document version 4.0 Part Number:
Table of Contents. Chapter 5 Backed-up Video Playback & Exportation... 29 5.1 Playing back Backed-up Video... 29 5.2 Exporting Backed-up Video...
inex Backup Table of Contents Chapter 1 Introduction... 1 1.1 System Diagram... 2 Backup Service Registered on Administration Service... 2 Backup Service Registered on Federation Service... 3 Chapter 2
Pcounter Mobile Guide
Pcounter Mobile Guide Pcounter Mobile Guide 2012.06.22 Page 1 of 19 1. Overview... 3 2. Pre-requisites and Requirements... 4 2.1 Gateway server requirements... 4 2.2 Mobile device requirements... 4 2.3
Data Loggers for Real Time Temperature Monitoring - WiFi
Data Loggers for Real Time Temperature Monitoring - WiFi Main Features Complete standalone system. Even if computer/network does not operate the recording system will continue to record without any interruption.
HORIZON Software Materials testing data acquisition and analysis software
B 200D HORIZON Software Materials testing data acquisition and analysis software TENSION COMPRESSION FLEXURE powerful materials testing software Tinius Olsen is proud to introduce you to the next evolution
User Manual Version 0.9.9.p BETA III December 23rd, 2015
User Manual Version 0.9.9.p BETA III December 23rd, 2015 Disclaimer: This document is provided as-is. Information and views expressed in this document, including URL and other Internet website references,
USB 3.0 to VGA External Multi Monitor Graphics Adapter with 3-Port USB Hub VGA and USB 3.0 Mini Dock 1920x1200 / 1080p
USB 3.0 to VGA External Multi Monitor Graphics Adapter with 3-Port USB Hub VGA and USB 3.0 Mini Dock 1920x1200 / 1080p StarTech ID: USB32VGAEH3 The USB32VGAEH3 USB 3.0 to VGA Adapter turns a USB 3.0 port
Gold Standard For sleep apnea detection and so much more
Gold Standard For sleep apnea detection and so much more NOX-T3 is a respiratory portable sleep recorder with extensive signal capabilities Audio recording from a built in microphone Abdomen and Thorax
Minimum Software and Hardware Requirements
Version 5 Jet and Version 5 SQL Minimum Software and Hardware Requirements Please note that these minimum requirements are designed to give adequate performance when running a simple database on the local
Parallels Desktop 4 for Windows and Linux Read Me
Parallels Desktop 4 for Windows and Linux Read Me Welcome to Parallels Desktop for Windows and Linux build 4.0.6576. This document contains the information you should know to successfully install Parallels
AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55. 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor with HM55 chipset
AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor with HM55 chipset AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor
Minimum Hardware Specifications Upgrades
Minimum Hardware Specifications Upgrades http://www.varian.com/hardwarespecs Eclipse TM treatment planning system Hardware V 11.0 1 TPS Version 11.0 Minimum Hardware Specifications [DELL OS supported upgrade
5100 SERIES 32-CHANNEL SWITCHBOX NVR
High Definition Surveillance 5100 SERIES 32-CHANNEL SWITCHBOX NVR Powerful IP recording solution supports up to 32 network IP security cameras + + Plug-and-play support for up to 16 compatible IP cameras
Preface Version 1.0 (1808. rev. 2)
A brand that is integrated into Samsung s network products, stands for a convenient world (Polis) made safe (Polis) through Samsung s superior network performance (Internet protocol). With products, clear
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
A-307. Mobile Data Terminal. Android OS Platform Datasheet
A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers
SOMITS is located in the 1648 Pierce Drive School of Medicine Building, Suite AB51.
School of Medicine Information Technology Services All newly enrolled School of Medicine students are encouraged to visit the School of Medicine s IT office before orientation to obtain help configuring
Adfotain Manager Express Release 1.3 Software User Manual May 2009
Adfotain Manager Express Release 1.3 Software User Manual May 2009 0 Contents 1. Overview... 1 1.1. Workflow... 1 1.2. Basic operations... 1 2. Installation... 2 2.1. Minimum system requirements... 2 2.2.
Point of view HDMI Smart TV dongle Mini RF Keyboard
Point of view HDMI Smart TV dongle Mini RF Keyboard English Contents Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents... 2 1. HDMI TV dongle... 3 1.1. Product display... 3 1.2. Instructions
CQG/LAN Technical Specifications. January 3, 2011 Version 2011-01
CQG/LAN Technical Specifications January 3, 2011 Version 2011-01 Copyright 2011 CQG Inc. All rights reserved. Information in this document is subject to change without notice. Windows XP, Windows Vista,
SeeTec ExpansionPackage
SeeTec ExpansionPackage Contents Contents 1 SeeTec WebClient...1 1.1 System requirements... 2 1.1.1 Server requirements for Apache HTTP Server, SeeTec TranscodingEngine (STE) and SeeTec ApplicationGateway
Requirements Document for ROI Print Assessment/Print Manager
Requirements Document for ROI Print Assessment/Print Manager Print Manager Pre-requisites for a successful deployment Contents 1. What is - a. Print Assessment? b. Print Manager? c. ROI Analytics? 2. About
Paragon. Intelligent Bond Testing Software. www.nordsondage.com
Paragon Intelligent Bond Testing Software www.nordsondage.com 2 Nordson DAGE Paragon Nordson DAGE Paragon 3 Nordson DAGE s next generation bond testing software Paragon, takes bond testing to the next
VeHiCle diagnostics the autocom way
VeHiCle diagnostics the autocom way CaRs trucks generic a Complete diagnostic solution CDP+ is a quick and reliable diagnostic tool serving as a link between vehicle and computer. It works on both old
AXIS 262+ Network Video Recorder
31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,
2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The standard system is shipped without HDD. 2. For the HDD compatibility list, please
VS-2104 Pro+ Hardware Spec. Processor Memory HDD Capacity Dual-core Intel processor 4GB RAM 2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The standard system is shipped without HDD. 2. For the
ACS CLIENT SOFTWARE USER MANUAL
ACS CLIENT SOFTWARE USER MANUAL 1 ACS USER GUIDE 1.1 System Requirement Recommended System Requirement OS CPU VGA RAM HDD WindowXP, Vista Pentium 4, 2Ghz 1024*768, 64MB 24bit color graphic card 1GB 20MB
SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.
SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional. 33-40006-001 REV: B PCSC 3541 Challenger Street Torrance, CA 90503 Phone: (310) 303-3600
Intel Core i3-2120 processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.
VS-8132 Pro+ Hardware Spec. Processor HDD Capacity Intel Core i3-2120 processor 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The system is shipped without HDD. 2. For the HDD compatibility list,
Hardware Requirements
Hardware Requirements This guide details the critical points of installing the IntraVet software from specific technology requirements to explicit hardware recommendations. communication organization practice
Line sheets system host software Measurement and automation systems. Connect and control with ABB. Introduction. Making sense of software
Data sheet DS/2101198-EN Rev. AG Line sheets system host software Measurement and automation systems Connect and control with ABB Introduction No matter the size of a gas production, gathering or pipeline
Recording. http://www.qnap.com/nvr/compatibilityx01.html. Smart recording (depending on the camera models)
VS-2108L Hardware Spec. CPU Marvell 1.6GHz DRAM 512MB DDRIII RAM Flash Memory 512MB Hard Disk Drive 2 x 3.5" SATA I/II hard disk drive (HDD) NOTE: 1. The system is shipped without hard disk drives. 2.
Monitor Wall 4.0. Installation and Operating Manual
Monitor Wall 4.0 en Installation and Operating Manual Monitor Wall 4.0 Table of Contents en 3 Table of Contents 1 Introduction 4 1.1 About this Manual 4 1.2 Conventions in this Manual 4 1.3 Minimum Installation
Alert, inform, react Aastra Alarm Server
Alert, inform, react Targeted alarming on all communication channels The effective transfer of information is important to increase a company s success and customer satisfaction. Information can be passed
DOC026.53.80098. PharmSpec 3. Software Manual. 10/2013, Edition 3
DOC026.53.80098 PharmSpec 3 Software Manual 10/2013, Edition 3 Table of Contents Section 1 PharmSpec 3 description...3 1.1 What is new in PharmSpec 3?...3 1.2 Software components...3 Section 2 Installation...5
Licenses of savic-net for Integrated Building Management System, and for FDA Title 21 CFR Part 11 Compliance
Specifications Licenses of savic-net for Integrated Building Management System, and for FDA Title 21 CFR Part 11 Compliance General The savic-net for Integrated Building Management System (hereinafter
Interactive White Board Solution on LED Touch Screen
Interactive White Board Solution on LED Touch Screen Combining LCD touch screen display technology with interactivity, Vestel educational display provides an interactive learning environment, bringing
CCC Technical Requirements. Updated: June 2016
Updated: June 2016 2016 All rights reserved. CCC is a registered trademark and the CCC logo is a registered service mark of CCC Information Services Inc. This document supersedes ALL previous Technical
Dualog Connection Suite Hardware and Software Requirements
Dualog Connection Suite Hardware and Software Requirements Author Kristian Olsen Date 29.Mar 2012 Description Revision Number 2.0 Environmental requirements and recommendations running Dualog Connection
How to Install and Set Up the FASTER Dashboard
How to Install and Set Up the FASTER Dashboard for Win & Web Steven Opetaia-Williamson FASTER Dashboard What you will know when you leave this session Understanding of what is the FASTER Dashboard Knowledge
VS-4112U-RP Pro+ Hardware Spec.
VS-4112U-RP Pro+ Hardware Spec. Processor Dual-core Intel processor Memory 4GB RAM HDD Capacity 4x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The standard system is shipped without HDD. For the
Quad Core Intel Xeon Processor E3. 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.
VS-12164U-RP Pro Hardware Spec. Processor HDD Capacity Quad Core Intel Xeon Processor E3 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The system is shipped without HDD. 2. For the HDD compatibility
GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay
-1- GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay Introduction The GV Hot Swap Backup Center System, designed for large scale video surveillance deployments, provides a secure remote backup
Web Server (IIS) Requirements
Web Server (IIS) Requirements Important! The Web Server (IIS) cannot be the primary or backup domain controller. Operating System Windows Server 2012 R2 Windows Server 2008 R2 (64-bit with IIS running
Fiery E100 Color Server. Welcome
Fiery E100 Color Server Welcome 2011 Electronics For Imaging, Inc. The information in this publication is covered under Legal Notices for this product. 45098226 27 June 2011 WELCOME 3 WELCOME This Welcome
Revit products will use multiple cores for many tasks, using up to 16 cores for nearphotorealistic
Autodesk Revit 2013 Product Line System s and Recommendations Autodesk Revit Architecture 2013 Autodesk Revit MEP 2013 Autodesk Revit Structure 2013 Autodesk Revit 2013 Minimum: Entry-Level Configuration
EZCast User s Manual
EZCast User s Manual Rev. 1.00 General EZCast is a special program to project your mobile device display to another screen through WiFi connection. You can enhance your TV/Projector with more features
IDIS Solution Suite. Backup Service. Software Manual. Powered by
Solution Suite Software Manual Backup Service Powered by Before reading this manual This Operation Manual provides instructions for using Solution Suite, a network integration solution enabling remote
IDIS Solution Suite. Backup Service. Software Manual. Powered by
Solution Suite Software Manual Backup Service Powered by Before reading this manual This Operation Manual provides instructions for using Solution Suite, a network integration solution enabling remote
LobbyWorks VMS Configuration and Technical Requirement Survey
LobbyWorks VMS Configuration and Technical Requirement Survey Initial Date Completed: Revised Date: Sales Person: Name Office Phone: Email Address Title: Mobile Phone: Customer Contact: Name: IT Person:
testo easyheat Configuration and Analysis software Instruction manual
testo easyheat Configuration and Analysis software Instruction manual en 2 General Information General Information This documentation includes important information about the features and application of
VEHICLE DIAGNOSTICS THE AUTOCOM WAY
VEHICLE DIAGNOSTICS THE AUTOCOM WAY CARS TRUCKS GENERIC A COMPLETE DIAGNOSTIC SOLUTION CDP+ is a quick and reliable diagnostic tool serving as a link between vehicle and computer. It works on both old
The All-in-One Support Solution. Easy & Secure. Secure Advisor
The All-in-One Support Solution. Easy & Secure. Secure Advisor Secure Advisor - A Perfect Solution for Online Support Fast and easy remote support from anywhere Problems that often sound complicated on
Item Minimum Required Recommended Notes
Carestream Dental strongly adheres to compliance with Microsoft Windows operating systems and hardware compatibility (HCL), which can be found at www.microsoft.com/whdc/hcl/default.mspx. Only operating
Priority Pro v17: Hardware and Supporting Systems
Introduction Priority Pro v17: Hardware and Supporting Systems The following provides minimal system configuration requirements for Priority with respect to three types of installations: On-premise Priority
Company Profile & product presentation. www.medigate.biz
Company Profile & product presentation Contents 1 About MEDIGATE, Inc. 2 Products 3 World wide partners About MEDIGATE, Inc. MEDIGATE, Inc. Reliable ECG & Body Composition Analyzer manufacturer in Korea.
Supported Platforms May 2013
Supported Platforms May 2013 This document is intended for restricted use only. Infinite Campus asserts that this document contains proprietary information that would give our competitors undue advantage
Sedao Ltd. SWEP HD Digital Signage Platform Introduction
Sedao Ltd SWEP HD Digital Signage Platform Introduction Version 3.1 Valid as at 15th June 2010 Introduction The SWEP HD is a small form factor personal computer which has been pre-configured to run Sedao
Frequently Asked Questions (FAQ)
Frequently Asked Questions (FAQ) Table of Contents Software Grant Program / Version... 3 1. What is the Autodesk Academic Resource Center?... 3 2. Can I have a hardcopy brochure about the ARC program?...
COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER
COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER TECHNICAL SPECIFICATIONS Communication Server 1000 Telephony Manager 3.2 Communication Server 1000 Telephony Manager 3.0 Communication
Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor
Servers, Clients Displaying max. 60 cameras at the same time Recording max. 80 cameras Desktop or rackmount form factor IVR-40/40-DSKT Intellio standard server PC 60 60 Recording 60 cameras Video gateway
v1 System Requirements 7/11/07
v1 System Requirements 7/11/07 Core System Core-001: Windows Home Server must not exceed specified sound pressure level Overall Sound Pressure level (noise emissions) must not exceed 33 db (A) SPL at ambient
CRM Outlook Plugin Installation
CRM Outlook Plugin Installation Last Modified on 01/15/2016 4:51 pm EST Hardware Requirements Component Minimum Recommended Processor Intel Pentium III 750-MHz CPU, or comparable Dual-core 1.8-GHz CPU
Client Hardware/Software Requirements for Dictaphone Enterprise Speech System, Version 8.3
Dictaphone Enterprise Speech System Client Hardware/Software Requirements Product: Dictaphone Enterprise Speech System Doc. Num: ESSA001h Version: 8.3 Date: 7/06/2012 Subject: Client Hardware/Software
Universal Form-factor. Wi Fi Troubleshooting Made Easy
AirMedic USB AirMedic USB is a powerful, easy-touse and affordable spectrum analysis tool that brings Wi-Fi troubleshooting to entry-level users. Built upon AirMagnet expertise in Wi-Fi troubleshooting,
Wireless Patient Monitoring
Wireless Patient Monitoring Live ECG streaming for mobile users and in-hospital ICU units. Full network integration with WAP Access point technology and Wi-Fi. Optional web server upload for telemedicine
SERVER SETUP GUIDE CREATED BY JOHN SHEATHER 25 AUGUST 2013. SambaPOS Server Setup Guide V2.0 1 of 25
SERVER SETUP GUIDE CREATED BY JOHN SHEATHER 25 AUGUST 2013 SambaPOS Server Setup Guide V2.0 1 of 25 Table of Contents SambaPOS Server Setup Guide... 3 Equipment used in this setup... 3 Software Used...