Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller

Similar documents
NITROUS TRANSFER PUMP INSTRUCTIONS

Stainless Steel Single and Dual Circulation Kits

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA. REF Rev. L

MODEL T200-F18 MODEL T125-F18 Finish Nailers

Rack installation instructions

Brookings Fire Dept. SCBA Specifications

Paratech s MULTIFORCE Air Lifting Bag takes lifting to a whole new level. Integrating the latest technology with a unique understanding of lifting,

Outdoor Cooking. Gas pressure Regulators & Accessories 2012 EDITION LPG & NATURAL GAS REGULATORS RE-02 DIVISION

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

HYDROSTATIC TEST PUMPS

MODEL G300 BRAKE BLEEDER

VW Caddy W INSTALLATION INSTRUCTIONS

VOYAGER 570G. 744A Sprayer Control

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

Instruction Manual. A50099 Calibration Device. TIE-DEX CALIBRATION DEVICE A50099

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

How To Use Vetter Mini Lifting Bags

SunMaxx Solar Filling Station Operating Instructions

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

WARNING CANADIAN D.O.C. WARNING

Porter Instrument Division

Installing a Probe. Typical Installation

UNIVERSAL 1550 PRE-MIX DISPENSER

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

needle valves Needle Valves Index At a Glance 1

Model 43AP Pneumatic Controller, Style B

FILLING AND PURGING THE SYSTEM

1805 Series Relief Valves

Oxygen & Nitrogen. Oxygen & Nitrogen Service Catalog. Parts & Complete Systems

Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators

OWNER S/OPERATOR S - PARTS MANUAL CEMENT MIXER MODEL MX-80

FAG Hydraulic nuts. Technical Product Information

P900 SERIES PORTABLE HYDROSTATIC TESTER

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

CHIPPING HAMMERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

6 Crankcase Ventilation

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Installation and maintenance instructions

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Section 8 Storage Tanks & Equipment

Rack Installation Instructions

G234X-55 Conventional Gas Boiler

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Fluid Monitoring and Inventory Management

Proportional Relief Valves

ROUGHNECK II Pumpless Drain

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

Hose Clamps & Fittings

EQUALIZER International Limited Range of Mechanical & Hydraulic Flange Spreading Wedges Operator Instruction Manual. B bestflangespreader

REGSON TM2 OXYGEN-THERAPY PRESSURE REGULATORS WITH FLOWMETER WITH PRE-ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION

SAFETY SAFETY APPAREL 20,000 PSI

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Series Hose Reels

413 NOVA SYSTEM PAN AMERICAN TOOL CORPORATION 5990 NW PHONE (954) TOLL FREE FAX

Baumann Little Scotty Bronze Control Valve

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

PS6500 Storage Arrays Rack Mount Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

PC1131 Electric Air Compressor

Chief S21M PARTS MANUAL Chief Automotive Technologies

KNC Model 3666 Automatic Pressure Calibration System

Technical Data. Installation

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Installation Instructions

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

INSTALLATION AND SERVICE MANUAL

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

Installing Cisco TelePresence MX200 G2 - Wheel Base

copy The New CFD Rabbit Tool: TNT FE-5.0 Forcible Entry Tool

For over 40 years, the leader in. nitrous oxide. equipment technology.

SPECIAL FEATURES. Air- Electric Clutch Control. Extended Beds and Rams

Industrial Torque Solutions

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

Itho Products for Hot and Boiling water. product-

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

2010 Residential Water Heater Replacement Check List

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

SERVICE MANUAL. Product No. P1320

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

Operating, Installation, and Maintenance Instructions

MP-4V Heavy Duty Riveter / 39048

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

1300 MAXTRAK SPECIFICATION

Rack Installation Instructions

Fluid Regulator. Instructions Parts List L LOW PRESSURE

DENTAL CHAIR AND UNIT SP- CIELA IMPORTANT

KF Needle & Gauge Valves

Transcription:

Specifications Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller Introduction These purchase specifications cover the minimum requirements of a Single Deadman Air Lifting Bag (ALB) Controller with relief valve to be purchased. The Single Deadman ALB Controller shall enable inflation of one (1) Air Lifting Bag System from a safe distance. The Single Deadman ALB Controller must be able to control an air lifting bag by activating a rocking lever to control inflation or deflation. As a minimum the system must consist of: Single Deadman ALB Controller (Equivalent to Paratech 22-889510G2-150) Instruction to Bidders Bidders shall conform as much as possible to these specifications to ensure interoperability with other equipment. Exceptions or omissions must be set out in writing on a separate sheet entitled Exceptions which must accompany the bid. Failure to do so will result in an automatic rejection of the bid. The buyer shall be the sole interpreter of the intent of any clause of these specifications and shall be the sole judge as to whether the equipment or any part thereof complies with the specifications. The buyer reserves the right to reject any and all bids, to waive informalities in bidding, to negotiate small options with the successful bidder and to accept the bid, which in the opinion of the buyer, will be in its best interest. General System Construction Features The controller shall be designed for maximum portability and confined space operations. The controller shall be ergonomically shaped and equipped with a single air inlet and one air outlet. Quantity, Dimensions and Capacities Single Deadman ALB Controller (equivalent to Paratech 22-889510G2-150) must be supplied with these minimum capacities: A carrying strap shall be provided to allow maximum operator mobility.

Weight of the Controller without a strap must not exceed = 3.04 lbs. (1.4 kg). Overall dimensions must not exceed: Width: 2.23 (2.7 cm) Height: 3.10 (7.9 cm) Length: 10.75 (27.4 cm) The gauge shall be a minimum of 1.5 (3.81 cm) in diameter and must be housed by a tight-fitting protective shroud. Accuracy of the grade B gauge at 73.4 F (23 C) is 3%, 2%, 3% of span. The Single Deadman ALB Controller shall have a self-resetting relief valve to prevent accidental over-pressurization of the lift bag which activates at 150 psi (10.3 bar) with a flow rate of 10.05 SCFM (602.76 SCFH). Both the inlet and the outlet shall be spring-loaded, female, quick-connect couplings. A secondary integral threaded safety lock system on the coupling must be in place. An internal check valve shall be provided to prevent air from escaping if inlet hose is cut or damaged. The Single Deadman ALB Controller shall be equipped with an inflation and deflation rocking lever, which requires positive pressure on the end of the lever during the inflation or deflation of the lifting bag. The lever shall be color-coded with proper labels to denote the function of the valve. The forward button must be for inflating and the rear button for deflating. The controller body must allow for the attachment of additional Single ALB Controllers in series with (1) air inlet and multiple outlets, that require: (1) Distributor Module (equivalent to Paratech 22-889531) per additional Controller, (4) Connecting Screws (equivalent to Paratech 22-890931) for the first two Controllers and then (2) extra screws per additional unit. Only (1) Distributor End Module (equivalent to Paratech 22-889532) and (2) Hex Lock Nuts (equivalent to Paratech 22-015716) are needed for any multiple configurations. It is required that the equipment meets or exceeds the EN 13731 Lifting Bag Systems for fire and rescue service use - Safety and performance requirements.

Specifications Dual Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller Introduction These purchase specifications cover the minimum requirements of a Dual Deadman Air Lifting Bag (ALB) Controller with relief valve to be purchased. The Dual Deadman ALB Controller shall enable inflation of one (1) or two (2) Air Lifting Bag Systems from a safe distance. The Dual Deadman ALB Controller must be able to control an air lifting bag by activating a rocking lever to control inflation or deflation. As a minimum the system must consist of: Dual Deadman ALB Controller (Equivalent to Paratech 22-8909000G2-150) Instruction to Bidders Bidders shall conform as much as possible to these specifications to ensure interoperability with other equipment. Exceptions or omissions must be set out in writing on a separate sheet entitled Exceptions which must accompany the bid. Failure to do so will result in an automatic rejection of the bid. The buyer shall be the sole interpreter of the intent of any clause of these specifications and shall be the sole judge as to whether the equipment or any part thereof complies with the specifications. The buyer reserves the right to reject any and all bids, to waive informalities in bidding, to negotiate small options with the successful bidder and to accept the bid, which in the opinion of the buyer, will be in its best interest. General System Construction Features The controller shall be designed for maximum portability and confined space operations. The controller shall be ergonomically shaped and equipped with a single air inlet and dual air outlet. Quantity, Dimensions and Capacities Dual Deadman ALB Controller (equivalent to Paratech 22-890900G2-150) must be supplied with these minimum capacities: A carrying strap shall be provided to allow maximum operator mobility. Weight of the Controller without a strap must not exceed = 4.6 lbs (2.1 kg).

Overall dimensions must not exceed: Width: 3.81 (9.68 cm) Height: 3.27 (8.31 cm) Length: 10.73 (26.34 cm) The controller shall be equipped with two (2) multi-colored operating gauges. The gauges shall be a minimum of 1.5 (3.81 cm) in diameter and must be housed by a tight-fitting protective shroud. Accuracy of the grade B gauge at 73.4 F (23 C) is 3%, 2%, 3% of span. The controller shall have a self-resetting relief valve to prevent accidental overpressurization of the lift bag which activates at 150 psi (10.3 bar) with a flow rate of 10.05 SCFM (602.76 SCFH). Both the inlet and the outlet shall be spring-loaded, female, quick-connect couplings. A secondary integral threaded safety lock system on the coupling must be in place. An internal check valve shall be provided to prevent air from escaping if inlet hose is cut or damaged. The Dual Deadman ALB Controller shall be equipped with two (2) each independently operated inflation and deflation rocking levers, which require positive pressure on the end of the lever during the inflation or deflation of the lifting bags. Each of the two (2) push levers shall be color-coded with proper labeling to denote the function and pressure limit of the valve with slip-resistant up & down rocker buttons. The forward button must be for inflating, rear for deflating. It is required that the equipment meets or exceeds the EN 13731 Lifting Bag Systems for fire and rescue service use - Safety and performance requirements.

Specifications Pressure Regulator 5,500-200 psi (379.2-13.8 bar) Introduction These purchase specifications cover the minimum requirements of a Pressure Regulator with a self-resetting relief valve to be purchased. The Pressure Regulator shall be capable of reducing inlet pressure of 5,500 psi (379 bar) to a constant working pressure of 200 psi (13.8 bar). The Pressure Regulator must be piston-type designed primarily for use with an SCBA air cylinder. As a minimum the system must consist of: Pressure Regulator (Equivalent to Paratech 22-895401G2) Instruction to Bidders Bidders shall conform as much as possible to these specifications to ensure interoperability with other equipment. Exceptions or omissions must be set out in writing on a separate sheet entitled Exceptions which must accompany the bid. Failure to do so will result in an automatic rejection of the bid. The buyer shall be the sole interpreter of the intent of any clause of these specifications and shall be the sole judge as to whether the equipment or any part thereof complies with the specifications. The buyer reserves the right to reject any and all bids, to waive informalities in bidding, to negotiate small options with the successful bidder and to accept the bid, which in the opinion of the buyer, will be in its best interest. General System Construction Features The Pressure Regulator shall be designed to reduce the pressure from a high-pressure air source to a suitable working pressure for use with an Air Lifting Bag System. The Pressure Regulator shall be of piston-type design and equipped with a 347/346 CGA inlet and ¼ NPT male nipple outlet. Quantity, Dimensions and Capacities Pressure Regulator (equivalent to Paratech 22-895401G2) must be supplied with these minimum capacities: Weight of the Pressure Regulator must not exceed = 3.62 lbs (1.64 kg).

Overall dimensions must not exceed: Width: 5.77 (14.7 cm) Depth: 3.52 (8.9 cm) Length: 6.05 (15.2 cm) The Pressure Regulator shall be equipped with two (2) operating gauges. One gauge shall monitor the supplied high pressure air with corresponding markings up to 6000 psi (400 bar). The second gauge shall monitor the outlet pressure with corresponding markings up to 400 psi (28 bar).the gauges shall be a minimum of 1.5 (3.81 cm) in diameter and must be housed by a tight-fitting protective shroud. Accuracy of the grade B gauge at 73.4 F (23 C) is 3%, 2%, 3% of span. The Pressure Regulator shall have a self-resetting relief valve to prevent accidental over-pressurization of the lift bag which activates at 200 psi (13.8 bar) with a flow rate of 9.55 SCFM (270.5 SLM). The Pressure Regulator shall be equipped with a 0-200 psi (13.8 bar) manual adjusting knob and have the ability to vent pressure when adjusting down the pressure (counterclockwise rotation). The Pressure Regulator shall be equipped with a 90 lever shut-off valve to disengage the air flow to the outlet. The lever positions shall be clearly marked with color-coded labels to indicate on and off points. It is required that the equipment meets or exceeds the EN 13731 Lifting Bag Systems for fire and rescue service use - Safety and performance requirements.