Fluid Regulator. Instructions Parts List L LOW PRESSURE
|
|
|
- Primrose Smith
- 9 years ago
- Views:
Transcription
1 Instructions Parts List LOW PRESSURE Fluid Regulator L For accurate, positive control of fluid pressure to one spray gun, dispensing valve, or atomizing head. For professional use only. 250 psi (18 bar, 1.8 MPa) Maximum Inbound Pressure Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Model Series H 0 60 psi (0 bar, 0 0. MPa) Regulated Pressure Gives positive control of fluid pressures in most normal direct supply and circulating spray systems. Model Series H 0 15 psi (0 1 bar, MPa) Regulated Pressure Has a counterbalance spring for positive closure at extremely low pressures. Model Series H psi ( bar, MPa) Regulated Pressure Has a heavier spring for precise control of fluid in the regulated range. Model Series H 0 60 psi (0 bar, 0 0. MPa) Regulated Pressure has a large valve for more viscous fluids. Not intended for use with standard paints and lighter viscosity fluids, as these fluids lower the sensitivity of this regulator.
2 Warnings Installation Operation Troubleshooting Warning Symbol WARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. EQUIPMENT MISUSE HAZARD Table of Contents Symbols Service Parts Warranty Graco Phone Number Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. WARNING Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. This equipment is for professional use only. Read all instruction manuals, tags, and labels before operating the equipment. Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. Do not alter or modify this equipment. Check equipment daily. Repair or replace worn or damaged parts immediately. Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system. Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer s warnings. Handle hoses carefully. Do not pull on hoses to move equipment. Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 66C (150F) or below 0C ( 0F). Wear hearing protection when operating this equipment. Do not move or lift pressurized equipment. Comply with all applicable local, state, and national fire, electrical, and safety regulations.
3 SKIN INJECTION HAZARD WARNING Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. Fluid injected into the skin is a serious injury. The injury may look like just a cut, but it is a serious injury. Get immediate surgical attention. Do not stop or deflect leaks with your hand, body, glove or rag. Always have the tip guard and the trigger guard on the gun when spraying. Check the gun diffuser operation weekly. Refer to the gun manual. Be sure the gun trigger safety operates before spraying. Lock the gun trigger safety when you stop spraying. Follow the Pressure Relief Procedure for your equipment if the spray tip clogs and before cleaning, checking or servicing the equipment. Tighten all fluid connections before operating the equipment. Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose. Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by kinks or bends near the couplings. MOVING PARTS HAZARD Moving parts can pinch or amputate your fingers. Keep clear of all moving parts when starting or operating the pump. Before checking or servicing the equipment, follow the Pressure Relief Procedure for your system to prevent the equipment from starting unexpectedly.
4 FIRE AND EXPLOSION HAZARD WARNING Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. If there is any static sparking or you feel an electric shock while using this equipment, stop spraying immediately. Do not use the equipment until you identify and correct the problem. Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed. Keep the spray area free of debris, including solvent, rags, and gasoline. Before operating this equipment, electrically disconnect all equipment in the spray area. Before operating this equipment, extinguish all open flames or pilot lights in the spray area. Do not smoke in the spray area. Do not turn on or off any light switch in the spray area while spraying or while operating if fumes are present. Do not operate a gasoline engine in the spray area. TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. Know the specific hazards of the fluid you are using. Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines. Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.
5 Installation KEY A B C D E F G H Regulator Dispensing Unit Gauge Regulator Inlet Regulator Outlet Air Regulator Supply Line Accessory Outlet C A G D F H E B Fig. 1 TYPICAL INSTALLATION CAUTION Before installing the regulator, check the tightness of the screws (1). Refer to Fig. 3 for the tightening sequence and the torque value. If the regulator leaks during operation, check and torque the screws again. In order to prevent damaging the regulator, blow out and flush the supply line to remove any particles. Install regulator (A) in fluid supply line as close as possible to spray gun or dispensing valve (B) for easy operator control. Mount the regulator in an upright position so that the gauge (C) can be easily read. If turning the gauge, reapply sealer to the threads, and use a wrench on the inlet stud to turn gauge. Regulator inlet (D) is 3/8 npsm (f) swivel and outlet (E) is 3/8 npsm (m) rigid. Connect a fluid hose to regulator outlet (E) and spray gun. Connect an air atomizing hose to the spray gun and air regulator (F) See Fig. 1. To mount the regulator in a circulating system supply line (G), install an accessory outlet (H). One outlet (H) and air regulator (F) are required for each spray gun. The accessory outlet (Part No ) may be ordered separately.
6 Operation WARNING To reduce the risk of component rupture, which can cause a fire or explosion and result in serious bodily injury, including splashing in the eyes, never exceed 250 psi (18 bar, 1.8 MPa) Maximum Inbound Fluid Pressure to this regulator. CAUTION Do not pressure test the regulator with air; use solvent. Air may cause leaks between the fluid seals and result in fluid leaks during normal operation. If the rest of the system must be pressure tested with air, loop past the regulator during the test. 1. Insert hex end of key (25) in adjusting screw (20) and turn counterclockwise until spring tension is relieved. See Figs 2 and Start pump and open shutoff valve of outlet (H) to admit fluid to regulator. Turn key (25) clockwise until desired fluid pressure shows on gauge. CAUTION Do not exceed the Regulated Pressure specification of your regulator. Pressures higher than specified can damage the gauge. Note: When reducing pressure, relieve pressure in gun and supply line to ensure a correct gauge reading. CLEANING THE REGULATOR Note: Flush the regulator every four weeks, or as necessary for the amount and type of use. 1. Clear regulator of paint or other fluid by blowing back fluid through the gun and hose. 2. Shut off supply pump and relieve line pressure by opening back pressure regulator or other by-pass valve. 3. Open regulator valve by screwing the threaded portion of key (25) as far as possible into the cap. See Fig. 2.. Loosen air cap ring of spray gun three turns, hold a rag firmly over the end of the cap and trigger the gun. Air will force fluid back through the gun, hose and regulator. 5. After blow-back, remove the adjusting key (25) Note: Do not use the threaded end of key (25) to adjust pressure. 6. Flush regulator until clean. Blow Back Position Fig Regulating Position
7 Troubleshooting Problem Cause Solution No pressure regulation Damaged diaphragm Replace diaphragm (31). Fluid leaks under cap Loose cap, worn gasket Tighten screws (1), replace gasket (32). Damaged diaphragm Replace diaphragm (31). Pressure creeps above setting Loose cap Tighten screws (1). Worn gasket Replace gasket (32). Damaged diaphragm Replace diaphragm (31). Worn or held open fluid valve Flush regulator, replace fluid valves (26 & 27) if worn excessively. Pressure drops below setting Loose cap Tighten screws (1). Worn gasket Replace gasket (32). Blocked fluid supply line or valve Flush supply line and valve, service if necessary. Using regulator beyond capacity Do not use regulator beyond its rated capacity.
8 Service Regulator Disassembly Note: Repair Kit is available for Models and See page 11 for parts included in the kit. Purchase the kit separately. Shut off pump, close shutoff valve and relieve pressure in regulator by triggering the spray gun. Remove the regulator from the system. 1. Using the hex end of key (25), adjust screw (20) all the way counterclockwise to relieve regulator spring tension. 2. Remove outlet bushing (15) and counter-balance spring (29) (Model only) from the body. 3. Unscrew valve stem (27) from diaphragm hanger (28) with adjusting key. See Fig. 3.. Remove screws (1), regulator cap (17), spring adjusting screw (20), spring (13), and spring cap (30) (Model only). 5. Lift diaphragm (31) and hanger from body. Disassemble the hanger and diaphragm only if damaged. 6. Unscrew valve seat (26) from body with a 9/16 socket wrench. See Fig Thoroughly inspect all parts and inspect for wear or damage, replacing as necessary. CAUTION Use special care in handling the valve stem and seat to avoid damaging the hard carbide parts. Regulator Reassembly Reassemble regulator in reverse order of Disassembly. When inserting the diaphragm and hanger, be sure that all surfaces are clean and smooth. Any dirt or roughness could damage the diaphragm. Note: Hold hanger (28) and valve stem (27) in place with a finger so that the valve stem is correctly lined up with the valve seat (26). The hanger should be in line with one set of holes and the nut should be torqued to 20 ft-lb (27 Nm). Turn the valve stem snugly against the seat and then back off 1/2 turn on model and 3/ turn on other models to set valve clearance. When installing the cap (17), line up finger of spring adjusting nut (12) with the groove in the cap (17). Torque the six screws (1) evenly to in-lb ( Nm) three times consecutively, in the order shown in the TOP VIEW, to compensate for diaphragm relaxation. See Fig. 3. Note: If further service is needed, see notes on lubrication, thread sealant, and torque values in Fig..
9 10 1 See TOP VIEW for tightening sequence. 2 Lubricate with oil. 3 Lubricate with grease. Torque to 20 ft-lb (27 Nm) Hanger must be parallel to diaphragm holes Torque to in-lb ( Nm) Gauge 1 27 TOP VIEW Fig. 3
10 Parts See torque sequence in Fig. 3. Lubricate with grease. PTFE side down. Apply sealant to threads. Torque to in-lb (8 9 Nm). Lubricate with oil. Torque to ft-lb (1 7 Nm) * Recommended tool box spare parts. Keep on hand to reduce down time. These parts are included in Repair Kit , which may be purchased separately. The kit is for use with Models and only. 21* 9 * * * 17 *5 32 * * 3 27 * * * * Fig.
11 Parts Ref No. Part No. Description Qty. Ref No. Part No. Description Qty SCREW, soc hd cap; 1/ 20 x 5/ PLUG, pipe; hex soc; 3/8 npt RACE, thrust; adjusting nut BEARING, needle thrust 1 5* GAUGE, fluid pressure; 0 30 psi (0 2 bar) (Model only) GAUGE, fluid pressure; psi (0 13 bar) (Model only) GAUGE, fluid pressure; 0 60 psi (0 bar) (Models & only) 1 7* GASKET, copper 1 9* SEAL, o-ring; thiokol NUT, lock; diaphragm TUBE, gauge mounting NUT, spring adjusting SPRING, flat compression (Models & only) SPRING, helical compression (Model only) SPRING, helical compression (Model only) UNION 5 swivel; 3/8 npt(m) x 3/8 npsm(f) BUSHING, fluid outlet BODY, regulator CAP, regulator ADAPTER; 3/8 npt x 3/8 npsm 1 Dimensions SCREW, adjusting 1 21* 1686 PLATE, diaphragm 1 22* GASKET, acetal KEY, regulating (removable) 1 26* SEAT, valve (Models & only) SEAT, valve (Model only) SEAT, valve (Model only) 1 27* STEM, valve (Model only) STEM, valve (Models & only) STEM, valve (Model only) 1 28* HANGER, diaphragm SPRING, helical compression (Model only) CAP, spring (Model only) 1 31* DIAPHRAGM 1 32* GASKET; cellulose fiber 1 33* GASKET; cellulose fiber WASHER, plain 1 * Recommended tool box spare parts. Keep on hand to reduce down time. These parts are included in Repair Kit , which may be purchased separately. The kit is for use with Models and only. 5.5 (10 mm) Weight: Model 20500: Model : Model 20501: Model 20525: lb (1.7 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) Model 20500: (285.8 mm) Models , 20501, & (27.7 mm).62 (15.8 mm) Fig. 5 3/8 NPSM (M) OUTLET 3/8 NPSM (F) INLET
12 The Graco Warranty and Disclaimers WARRANTY Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PUR- POSE. Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS, OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. For Sales to Canadian Customers: Except as expressly stated herein, Graco makers no representations, warranties or conditions, express, implied or collateral, concerning any goods or services sold, and GRACO SHALL NOT BE LIABLE IN ANY MANNER FOR any other representation, warranty or condition of any kind, whether arising by operation of law or otherwise, including but not limited to, WARRANTIES OF MERCHANTABLE QUALITY OR FITNESS FOR A PARTICULAR PURPOSE. LIMITATION OF LIABILITY In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or for the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. Graco Information For the latest information about Graco products, visit TO PLACE AN ORDER, contact your Graco distributor or call to identify the distributor closest to you: Phone: or Toll Free: Fax: All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. AND SUBSIDIARIES P.O. BOX 11 MINNEAPOLIS, MN USA Copyright 1996, Graco Inc. All Graco manufacturing locations are registered to ISO Revised 12/2011
Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST. 3000 psi (210 bar) Maximum Working Pressure. Model 204 355, Series K. Rev.
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 306 586 Rev. D Supercedes B Extrusion Flo-Valve Model 204 355, Series K 3000 psi
55-Gallon Dispenser Package
INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon ispenser Package 08666 Rev. C INSTRUCTIONS This manual contains important warnings and information. REA AN KEEP FOR REFERENCE. 100 psi (6.9 bar) Maximum Air
Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.
Instructions Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG Model 24G766 Important Safety Instructions For complete warnings and safety instructions see RoadLazer RoadPak
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input
Feed Pump and Agitator Kits
Instructions - Parts Feed Pump and Agitator Kits 2769D EN Supplies viscous materials from drums or 20 gallon hoppers to XM and XP70 plural-component sprayers. Important Safety Instructions Read all warnings
- For pumping exact amounts of lubrication fluids from a reservoir to specific lubrication points -
Instructions DSL/SVK Pumps 313261D ENG - For pumping exact amounts of lubrication fluids from a reservoir to specific lubrication points - DSL Models: 256907, 256908, 256929 3000 psi ( 20.7 MPa, 206.8
Ultra-Lite In-Line Flow Gun
INSTRUCTIONS-PARTS LIST 308 807 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. Rev. B Supersedes A Ultra-Lite In-Line
Instructions Parts List
Instructions Parts List AIR DRIVEN Twistork Helix Mixer 30875P 00 psi (0.7 MPa, 7 bar) Maximum Working Pressure Model 224854, Series D Carbon Steel Agitator Model 235534, Series D Stainless Steel Agitator
Battery Charger. Instruction Manual 309502G
Instruction Manual Battery Charger 309502G EN Part No. 117427, Single Bay Charger, Series B, North America (N.A.) Part No. 120110, Single Bay Charger, Series B, Australia Part No. 117429, Four Bay Charger,
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
OP300S / OP350 2:1 RATIO TRANSFER PUMP
OP300S / OP350 2:1 RATIO TRANSFER PUMP OPERATING MANUAL WITH PARTS IDENTIFICATION Copyright 2013 International Pump Manufacturing, Inc. This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Read and
Pump for Drywall Feed Pump System
Repair Pump for Drywall Feed Pump System 3A0912A ENG - For water-based materials only - - Not for use in explosive atmospheres - - Not for use with quick-set materials - READ ALL WARNINGS AND INSTRUCTIONS
SE-100-1, SE-200-1, SE-500-1, and SE-1000-1 AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81) 83 54 10 18 ventas@industrialmagza.
AIR CHAMP PRODUCTS User Manual SE BRAKE MODELS: SE-00-, SE-200-, SE-500-, and SE-000- (i) FORM NO. L-20084-E-040 In accordance with Nexen s established policy of constant product improvement, the specifications
15:1 Fire-Ball 300 Pumps
Instructions Parts List 15:1 Fire-Ball 300 Pumps 306531Z1 For pumping petroleum based undercoating material. 2700 psi (18.6 MPa, 186 bar) Maximum Working Pressure 180 psi (1.2 Ma, 12 bar) Maximum Air Input
AirPro Gravity Feed Airspray Gun
Instructions-Parts AirPro Gravity Feed Airspray Gun 312579K EN Conventional, HVLP, and compliant guns for specialty industrial applications. For professional use only. 100 psi (0.7 MPa, 7 bar) Maximum
Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions
795 08690 GM 12 00 Graymills Air Operated Double Diaphragm Pumps Operations and Maintenance Instructions /S Read all these SAFETY INSTRUCTIONS BEFORE installing or using this equipment. Keep this manual
GH 833 Sprayers 311283C
Repair GH 833 Sprayers Korean patent: 10-0647761 311283C - Use with Architectural Coatings, Paints, Roof Coatings and Below Grade Coatings - 4000 psi (27.6 MPa, 275.8 bar) Maximum Working Pressure Important
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
PALLET JACK - 2.5 TON
PALLET JACK - 2.5 TON 39939 SET UP AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
BINKS MODEL 460 LIGHTWEIGHT AUTOMATIC SPRAY GUN
SERVICE MANUAL EN BINKS MODEL 460 LIGHTWEIGHT AUTOMATIC SPRAY GUN AIR FLOW ADJUSTMENT Clockwise to reduce pressure; Counterclockwise to increase pressure. 1/2" DIA. MOUNTING HOLE FLUID NEEDLE ADJUSTMENT
PAINT SPRAY GUN WASHER
PAINT SPRAY GUN WASHER 94996 ASSEMBLY AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious
240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS
OPERATION MANUAL GLOBAL ELECTRONIC MIX SOLUTIONS PLURAL COMPONT MIXING SYSTEM 240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS 77-3087-R1.0 (8/2015) 1 / 5 In this part sheet, the words WARNING, CAUTION
Test Fixture, High Voltage Probe, and kv Meter
Instructions/Parts List Test Fixture, High Voltage Probe, and kv Meter 309455B EN For Graco Pro Xp and PRO Xs Electrostatic Spray Guns, to test the electrostatic voltage of the spray gun, as well as the
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Installation, Maintenance, & Repair Series 4000B/LF4000B
Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using
VISCON TM FLUID HEATER
Instructions Parts List (VIScosity CONtrol), STAINLESS STEEL VISCON TM FLUID HEATER 307914E 4000 psi (27.6 MPa, 276 bar) Maximum Working Pressure Part No. 222307, Series B, Bare Heater Part No. 237947,
758 Heavy-duty Ratchet Guy Wire Cutter
INSTRUCTION MANUAL 758 Heavy-duty Ratchet Guy Wire Cutter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product
Hydraulic Transmission Jacks Operating Instructions & Parts Manual
Blackhawk Automotive is a Licensed Trade Mark Made by SFA Companies, Kansas City, MO Hydraulic Transmission Jacks Operating Instructions & Parts Manual Model BH7011 BH7210 Capacity 1/2 Ton 1 Ton SFA Companies
G15/G40 Spray Gun. Instructions - Parts List 3A0149E EN II 2 G
Instructions - Parts List G15/G40 Spray Gun 3A0149E EN A lightweight line of air-assisted spray guns for spraying and finishing a variety of paints and coatings, particularly in applications requiring
BINKS SV100 CONVENTIONAL SUCTION FEED SPRAY GUN
SERVICE MANUAL EN BINKS SV100 CONVENTIONAL SUCTION FEED SPRAY GUN The following instructions provide the necessary information for the proper maintenance of the Binks SV100 suction feed spray gun. Please
Instructions and precautions. Fork Height. Visit our website at: http://www.harborfreight.com
Pallet Jack Item 68760 / 68761 Instructions and precautions Specifications Capacity Control Lever Fork Height Fork Length Fork Width Maximum Minimum Width over Forks Steering Wheel Dia. 2-1/2 Ton (5,000
In-Line Filters and Coalescers with Automatic Drains
Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid
BINKS SG-2 PLUS TM 2 QT. PRESSURE CUPS
SERVICE MANUAL EN BINKS SG-2 PLUS TM 2 QT. PRESSURE CUPS MODEL NO. 80-600 (STANDARD) MODEL NO. 80-601 (WITH OSCILLATING AGITATOR) INTRODUCTION Binks SG-2 Plus TM Pressure Cup is ideal for component spraying
Instructions Parts List
Instructions Parts List ALUMINUM AND STAINLESS STEEL Husky 590 Air-Operated Diaphragm Pumps 0844ZAG.5 inch AODD pump for fluid transfer applications. For professional use only. See Models on page for a
Table of Contents WARNING SYMBOLS AND DEFINITIONS
Table of Contents SAFETY INSTALLATION OPERATION MAINTENANCE Safety... 2 Specifications... 4 Installation... 5 Operation... 8 WARNING SYMBOLS AND DEFINITIONS Maintenance... 9 Parts List and Assembly Diagram...
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
tire inflator with pressure gauge
tire inflator with pressure gauge Model 95583 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
PET-10 INSTRUCTION MANUAL PRESSURE TANK
INSTRUCTION MANUAL PRESSURE TANK PET-10 This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Equipment in this manual is exclusively for painting purposes. Do not use for other purposes. The operator
PNEUMATIC PLANISHING HAMMER
PNEUMATIC PLANISHING HAMMER 94847 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. Distributed Exclusively by Harbor
ADP Autoline 3A0986A ENG
ADP Autoline 3A0986A ENG Definition of Terms Definition of Terms DMS: Dealer Management System Generic term referring to the business system a car dealership or similar organization uses to manage their
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Binks MACH 1PC HVLP SPRAY GUN FOR PLURAL COMPONENT CATALYST INJECTION
Binks MACH 1PC HVLP SPRAY GUN FOR PLURAL COMPONENT CATALYST INJECTION The Binks MACH PLURAL COMPONENT 1PC HVLP Gun is the lightest top quality high performance spray gun available today. You only have
Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.
ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
Parts. Ultra 395/495/595t Ultra Max II 490/495/595t 309675V 120 VAC. 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure.
Parts Ultra 395/495/595t Ultra Max II 490/495/595t 309675V EN 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure 0 VAC Type Stand Series Lo-boy Series Hi-boy Series Ultra 395t 2339 B 233961 B 233962
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES
GATE VALVE O.S. & Y 1.0 Periodic Inspections 1.1 The valve stem packing should be inspected at least monthly. If the stem packing shows signs of leakage, simply tighten the adjusting nuts to compress the
FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions
FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
SINGLE STAGE INLINE FIRE PUMP
MODEL 383 SINGLE STAGE INLINE FIRE PUMP INSTRUCTION AND REPAIR MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains
Instructions Parts List
Instructions Parts List ACETAL AND POLYPROPYLENE Husky 307 Air Operated Diaphragm Pumps For fluid transfer applications. For professional use only. Only pumps with acetal fluid sections are approved for
T1 2:1 Ratio Transfer Pump
Instructions - Parts List T1 2:1 Ratio Transfer Pump 312766N EN For use with polyurethane foam, polyurea, and solvent-borne and water-borne materials. For professional use only. Model 256200 55 Gallon
OAK WORKBENCH WITH 2 DRAWERS
OAK WORKBENCH WITH 2 DRAWERS Model 93991 ASSEMBLY Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
BOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped
GM DURAMAX LMM 09-10 Fuel Pickup Kit Installation Guide
Pacific Performance Engineering, Inc. www.ppediesel.com GM DURAMAX LMM 09-10 Fuel Pickup Kit Installation Guide Technical Support (714) 985-4825 Rev: 3/30/11 v5 DISCLAIMER OF LIABILITY This agreement sets
10 TON HYDRAULIC PRESS
10 TON HYDRAULIC PRESS Model Nos. CSA10F and CSA10B OPERATING & MAINTENANCE INSTRUCTIONS 0200 SPARE PARTS and SERVICING Please contact your nearest dealer, or CLARKE International, on one of the following
TECHNICAL SERVICE MANUAL
TECHNICAL SERVICE MANUAL HEAVY-DUTY PUMPS SERIES 4195 AND 495 SIZES GG - AL SECTION TSM 144 PAGE 1 of 10 ISSUE D CONTENTS Introduction....................... 1 Safety Information.................... 2
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
Universal Adjustable Fuel Pressure Regulator
Universal Adjustable Fuel Pressure Regulator Installation Instructions for: Part Numbers 25-302 U.S. Patent # 6,298,828! Due WARNING: to the fact that this installation deals with your fuel system this
1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
STEERING SYSTEM - POWER
STEERING SYSTEM - POWER 1990 Nissan 240SX 1990 STEERING Nissan - Power Rack & Pinion Axxess, Maxima, Pulsar NX, Sentra, Stanza, 240SX, 300ZX DESCRIPTION The power steering system consists of a rack and
300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS
Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES
HYDRAULIC LIFT TABLE CART 2200-LB.
HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
580-6001 INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES
ADI 3205-A Certified ISO 9001 580-6001 Micron Filter Assembly INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES Before Installing or Operating, Read and Comply with These
Instructions Parts List
Instructions Parts List ALUMINUM, STAINLESS, AND DUCTILE IRON Husky50 Air Operated Diaphragm Pumps 308368ZAG inch AODD pump for fluid transfer applications. For professional use only. See Models on page
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3
staple gun with 5/16 Long staples
staple gun with 5/16 Long staples Model 95718 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks
This instruction is valid for all ACD pump models shown on page 2
Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals
AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: SE-100-1, SE-200-1, SE-500-1, and SE-1000-1 1 FORM NO. L-20084-H-0814
AIR CHAMP PRODUCTS User Manual SE BRAKE MODELS: SE-100-1, SE-200-1, SE-500-1, and SE-1000-1 1 FORM NO. L-20084-H-0814 In accordance with Nexen s established policy of constant product improvement, the
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
HYDRAULIC TABLE CART
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
12V Portable Diaphragm Compressor Operating and Maintenance Instructions
12V Portable Diaphragm Compressor Operating and Maintenance Instructions (Part No. DC2) Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Guidelines for Product Use...2 Operation
American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems
American Fireglass Outdoor Fire pit kit information General instructions/warnings for outdoor gas pan and burner systems We strongly recommend that our burner products be installed by a licensed and certified
Installation, Operation, Repair and Parts Manual
2088 Agricultural Series Pumps Installation, Operation, Repair and Parts Manual Form 911-396 6/11, Rev. A Description Model 2088-343-135 Automatic-Demand Pumps / 12 VDC These SHURflo 2088 Series diaphragm
Flat Bottom Long Ram Hydraulic Jack
Flat Bottom Long Ram Hydraulic Jack 3 Ton 8 Ton 36468 36469 ASSEMBLY & OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
GlasCraft Catalyst Pump
Repair - Parts GlasCraft Catalyst Pump 3A1218H EN For use with Graco polyester resin and gel coat systems. For professional use only. See page 2 for models. Important Safety Instructions Read all warnings
MP-4V Heavy Duty Riveter / 39048
MP-4V Heavy Duty Riveter / 39048 This newly designed heavy-duty air/hydraulic riveter is ergonomically designed with the professional in mind. The light weight 3.7 lbs. well balanced MP-4V includes a Vacuum
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Binks Model 7 Spray Gun (6100-XXXX-X)
Binks Model 7 Spray Gun (6100-XXXX-X) Your new Binks spray gun is exceptionally rugged in construction, and is built to stand up under hard, continuous use. However, like any other fine precision instrument,
15GAL STEEL OIL DRAIN WITH 110V PUMP
15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1
Hydraulic Air Riveter Recommend for mass production line industrial area Operation Manual RC197 RC198 Page 1 CONTENTS 1 Important Safety Rules 2 Tool Specification 2.1 Nomenclature 2.2 Technical Data 3
8 ton air/hydraulic long ram jack
8 ton air/hydraulic long ram jack Model 94562 Set up and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result
2" & 3" Poly Wet Seal Pump Instruction Manual
Always place the pump as close to the liquid to be pumped as possible. Keep the suction line short and with few bends. Keep the pump and engine on a level foundation. A poor foundation and a heavy suction
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
Dryaire Desiccant System
Instructions/Parts Dryaire Desiccant System 310595F Model 6760 Maximum Operating Pressure: 160 PSI (1.1 MPa, 11 bar) System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1
Serial No. H-V066-E-2 Wafer Check Valve User s Manual Contents (1) Be sure to read the following description of our product warranty 1 (2) General operating instructions 2 (3) General instructions for
MODEL T200-F18 MODEL T125-F18 Finish Nailers
P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS
cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.
- Easy -wire installation with no external spark box necessary, but can be used with one. - Precision CNC machining and hand assembled construction. This is a premium product. - Accurate super hot spark
ROTOR LOADER OWNER S MANUAL
ROTOR LOADER OWNER S MANUAL ROTOR LOADER OWNER S MANUAL WARNING IMPORTANT SAFETY INSTRUCTIONS AND GUIDELINES. Misuse of paintball equipment may cause serious injury or death. QUICK SET-UP GUIDE BATTERY
OWNER S MANUAL Table Tennis Table Patent Pending
OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179