Application software. IP/KNX Interface Electrical / Mechanical characteristics : see product information. Order number. TP device RF devices

Similar documents
Application program usage. Functional description. Note. Note. instabus EIB Application Program Description. August CO IP-Interface

KNX IP INTERFACE IN00A02IPI. Operating and installation manual

KNX IP Interface. Operating and installation manual

IN00A01IPI. Hardware specification KNX IP INTERFACE IN00A02IPISH IN00A02IPISH Specifica N. Progetto N. Titolo del progetto

EIB/KNX IP Interface with Power over Ethernet (PoE)

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ABB i-bus KNX IP Router IPR/S 2.1

instabus EIB Manual February 2004 Table of Contents

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

ethernet connection For more information about the printer's ethernet feature, click the topic below: ethernet lights network configuration page

Follow these steps to prepare the module and evaluation board for testing.

Check Your Package Contents. CD-ROM containing Manual and Warranty

BROADBAND INTERNET ROUTER USER S MANUAL. Version Page 1 of 13 -

STATIC IP SET UP GUIDE VERIZON 7500 WIRELESS ROUTER/MODEM

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Preparing the Computers for TCP/IP Networking

DSL Installation Guide

Wireless LAN g USB Adapter

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

HWg-STE HWg-STE PoE MANUAL

1. Hardware Installation

User Manual Network Interface

3.5 EXTERNAL NETWORK HDD. User s Manual

LAN TCP/IP and DHCP Setup

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

Chapter 4 Management. Viewing the Activity Log

Internet for Everyone In-Room Instructions January 2011 Version 1.3

Application & Quick-Start Guide

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

Wireless Router Setup Manual

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

LevelOne. User Manual. FBR-1430 VPN Broadband Router, 1W 4L V1.0

NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn)

Multi-Homing Dual WAN Firewall Router

The PostBase Connectivity Wizard

Broadband Router ALL1294B

Chapter 10 Troubleshooting

Firewall VPN Router. Quick Installation Guide M73-APO09-380

DI-634M. Check Your Package Contents. This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 7.

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

RouteFinder. SOHO Security Appliance. Quick Start Guide RF820 & RF820-AP RF830 & RF830-AP

TR-7W Configuration Guide. Before You Start

Victoria Combo Remote Control

Chapter 2 Connecting the FVX538 to the Internet

Chapter 3 Management. Remote Management

c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem

UIP1868P User Interface Guide

3.5 LAN HDD Enclosure User s Manual

Chapter 1 Installing the Gateway

UDS2100 Quick Start Guide

TW100-BRV204 VPN Firewall Router

ADSL MODEM. User Manual V1.0

Linksys Gateway SPA2100-SU Manual

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

DSL-2600U. User Manual V 1.0

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

The following sections describe the Gateway configuration pages in the SBG1000 Setup Program.

OUTDOOR IR NETWORK CAMERA Series

SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

Model:BL-WDR Mbps Wireless Dual Band 11AC Router

TECH BULLETIN NETGEN1 DOOR CONTROLLER WI-FI NETWORK CONFIG

User Manual. Sipura SPA-2100 ATA with PC Router. January 2005 v1. Linhagratuita grupo csdata

SNMP Manager User s Manual

WUA Mbps Wireless USB Network Adapter

Chapter 7 Troubleshooting

Application Note Configuring the UGate 3000 for use with ClipMail Pro and ClipExpress

ASUS WL-5XX Series Wireless Router Internet Configuration. User s Guide

Prestige 660R-6x Read Me First

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

TW100-BRF114 Firewall Router. User's Guide. Cable/DSL Internet Access. 4-Port Switching Hub

Chapter 6 Configuring the SSL VPN Tunnel Client and Port Forwarding

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

Chapter 6 Using Network Monitoring Tools

How To Set Up A Computer With A Network Connection On A Cdrom 2.5 (For A Pc) Or Ipad (For Mac) On A Pc Or Mac Or Ipa (For Pc) On An Ipad Or Ipro (

User Manual. EtherUSB

Click Main on the left hand side then click on Password at the top of the page.

DSL- G604T Frequently asked Questions.

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

UPS Network Interface. Quick InstallationGuide

Talk2M ewon Internet Connection How To

Appendix C. Network Requirements. The Browser Interface. For Windows

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer.

Sweex Wireless BroadBand Router + 4 port switch + print server

47611 GT4. Internet Gateway. Broadband Internet Access. 4-Port Switch. User's Manual

User s Manual. Copyright 2010 Vantec Thermal Technologies. All Rights Reserved.

ProSAFE 8-Port and 16-Port Gigabit Click Switch

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

SMC7004ABR Barricade Broadband Router Installation Instructions

Enabling Internet Connection Sharing on Windows Enabling ICS On Windows XP As The Host 4 Enabling ICS On Windows XP As The Client 11

Setting up VPN Access for Remote Diagnostics Support

USB Ethernet Connectivity Kit

Protecting the Home Network (Firewall)

You may refer the Quick Installation Guide in the package box for more information.

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

EMG Ethernet Modbus Gateway User Manual

CHANGE NETWORK SETTINGS Technicolor TG582n

Transcription:

Application software IP/KNX Interface Electrical / Mechanical characteristics : see product information Order number Product designation Application software ref. TP device RF devices TYF120 IP/KNX Interface STYF120 TYF120 1 6T8729-02a

Summary 1. FUNCTIONAL DESCRIPTION... 3 2. COMMUNICATION OBJECTS... 5 2.1 Parameter General... 5 2.2 Parameter IP Konfiguration... 5 2.2.1 IP Config 1... 5 2.2.2 IP Config 2... 6 3. SETTING THE COMMUNICATION INTERFACE... 8 3.1 in ETS3... 8 3.2 in ETS4... 10 4. SETTING THE ADDITIONAL INDIVIDUAL ADDRESS OF THE IP INTERFACE... 12 4.1 in ETS3... 12 4.2 in ETS4... 13 TYF120 2 6T8729-02a

1. Functional description This device utilizes the KNXnet/IP standard and enables communication connections to KNX lines or systems via data networks using the Internet Protocol (IP). PC s or other data processing equipment can exchange data with KNX devices through this communication link. The physical connection to the KNX bus is established via a bus connector terminal block. For connection to the data network (IP via 10BaseT) the device contains an RJ45 socket. By using a LAN modem a KNX installation can be remotely accessed even if there is no direct data network connection between a PC and an IP Interface. LAN modems are available on the market for standard telephone, ISDN or DSL connections. The IP Interface requires additional operating power for its operation. The IP Interface can source this operating power via the network connection from Power over Ethernet according to IEEE 802.3af. Alternatively, the operating power can be provided via a second terminal block (white-yellow terminals) by a safety extra low voltage (SELV) power supply AC/DC 24 V. When a SELV power supply is connected the operating power is sourced from it The IP Interface has these characteristics: Simple connection to hierarchically superimposed systems via Internet Protocol (IP) Direct access to the KNX installation from any access point to the IP network (KNXnet/IP Tunneling) Communication between buildings and facilities LED display of - operation - KNX communication - IP communication Simple configuration with standard ETS Easy connection to SCADA and Facility Management systems (see: Supported Software) KNXnet/IP Tunneling interface to the bus A direct connection between a networked PC and the bus can be established via a data network and the IP Interface. This allows for accessing the busfrom any access point in the data network. The IP Interface provides up to five KNXnet/IP Tunneling connections, allowing for e.g. simultaneous configuration with ETS3 and operation of visualization. Note For stable communication via KNXnet/IP Tunneling the IP Interface must use a separate individual address for each KNXnet/IP Tunneling connection. These additional individual addresses must be different from the individual address of the device and must not be used by any other bus device. In ETS these individual addresses should be reserved by proxy devices. ObjectServer interface to the bus A direct connection between a networked PC and the bus can also be established via a data network and the IP Interface using ObjectServer. ObjectServer compared with KNXnet/IP Tunneling provides the advantage that the communication can be maintained even over network connections with a transmission time for the datagrams of over one second (e.g. satellite connections). TYF120 3 6T8729-02a

Assignment of additional individual address(es) Additional individual addresses are either assigned with ETS (see: Setting the additional individual address of the IP Interface with ETS3) or alternatively without a tool automatically by the device itself. The automatic address assignment for KNXnet/IP Tunneling and ObjectServer is started when the learning button is pressed during normal operation for more than 5 seconds but less than 10 seconds. The programming LED flashes during the address assignment process. The device checks which individual addresses are already used by other bus devices connected to the bus line. These addresses are not used for the address assignment. By adding additional bus devices at a later time one or more of the additional individual addresses could be assigned twice. When during normal operation the learning button is pressed for more than 10 seconds all additional individual addresses in the IP Interface are reset to the default value (15.15.255) and the programming LED is turned off. IP address assignment Please consult your network administrator regarding configuration of the parameters device IP address, subnet mask, and DHCP. The IP address of the IP Interface is assigned manually using ETS, automatically by a DHCP server in the IP network, or by the device itself (AutoIP). Assignment of the IP address by a DHCP server allows for changes of the device IP address without using ETS. Configuration of the DHCP server may require the MAC address, which is printed on the device. If a DHCP server is not available the device assigns itself an IP address (AutoIP). Default factory settings The IP Interface ships with these defaults factory settings: Physical address of the IP Interface: 15.15.15 (= FFFF hex) IP address assignment via DHCP Configuration with ETS The IP Interface can be configured with ETS2 V1.2 and later versions. Note The IP Interface can be reset to the default factory settings by pressing the learning button for more than six seconds when the operation voltage is turned on. The transition to the default state is indicated by a blinking programming LED. All parameter settings are deleted by this reset action. TYF120 4 6T8729-02a

2. Communication objects The application program does not contain any communication objects. 2.1 Parameter General Parameter Settings Device name IP_KNX_Interface (max. 30 char) This parameter determines the name (max. 30 characters) of the IP Interface, which is used for easy recognition of the device when searched by an KNXnet/IP visualisation or the ETS. IP Address by DHCP Server Assignment manual input This parameter determines the type of IP address assignment. By manual input is selected two additional tabs appear for manual input default the parameter is set for automatic assignment of the IP address by a DHCP server. If of the IP address, subnet mask, and the default gateway address. 2.2 Parameter IP Konfiguration 2.2.1 IP Config 1 Parameter Settings IP Adress 0.0.0.0 Byte 1, Byte 2, Byte 3, Byte 4 This parameter is only visible if manual input was chosen for IP Address Assignment. It determines the IP address of the IP Interface. The factory default setting for the IP address is 0.0.0.0. This default value must be replaced by a valid IP address. Each byte of the four byte IP Routing Multicast Address is set separately, with a value range of 0...255 for each byte. TYF120 5 6T8729-02a

Parameter IP Subnetz Maske Byte 1, Byte 2, Byte 3, Byte 4 Settings 0.0.0.0 B This parameter is only visible if manual input was chosen for IP Address Assignment. It determines the IP subnet mask used by the IP Interface. The factory default value is 0.0.0.0. This default value must be replaced by a valid subnet mask. Valid subnet mask values are e.g. 255.255.255.0 or 255.255.240.0. Each byte of the four byte IP Routing Multicast Address is set separately, with a value range of 0...255 for each byte. 2.2.2 IP Config 2 Parameter Settings IP Standard Gateway 0.0.0.0 Byte 1, Byte 2, Byte 3, Byte 4 This parameter is only visible if manual input was chosen for IP Address Assignment. It determines the IP address of the IP Standard Gateway. The factory default value is 0.0.0.0. This default value may be replaced by a valid IP address. Each byte of the four byte IP Routing Multicast Address is set separately, with a value range of 0...255 for each byte. The Standard Gateway transmits IP datagrams to IP devices with IP addresses outside of the local network. Use the prede- fined (invalid) IP address (0.0.0.0) if the device shall be configured without a Standard Gateway. Note When an IP Interface is unloaded this unloading process may fail with the error message An internal error occurred. Subsequently, no other device can be configured and ETS displays the error message An internal error occurred.. When attempting to check the Settings in menu Extras Options Communication the error message Severe error appears. The problem is solved by either selecting a different interface or by closing and restarting ETS. TYF120 6 6T8729-02a

Note If the communication to the KNX bus fails when a KNXnet/IP Tunneling connection exists then, even if the KNX bus is reconnected, a connection to the bus cannot be established and a download fails. The problem is solved by either selecting a different interface or by closing and restarting ETS. Then a connection to the previously used IP device can be established. The same behavior shows if the power to the IP device fails. Note If the IP Interface is used as an interface to the bus and its own configuration is downloaded via the bus then ETS displays the error message The device with the individual address %1 cannot be found.. The download is not executed. The problem is solved by either selecting a different interface or by closing and restarting ETS. Then a connection to the IP Interface can be established. Note After installing the ETS3 driver and selecting the IP Interface or the IP Router as communication interface a windows message may pop up announcing that a "Class" is unknown. In this case install the Microsoft.Net Framework that you can download from the Microsoft software update site (file size: approx. 25MB). TYF120 7 6T8729-02a

3. Setting the communication interface 3.1 in ETS3 In ETS3 select Extras Options. In the Options window select the Communication tab. Click on Configure Interfaces. Generate a new interface and select the type KNXnet/IP. ETS3 automatically searches for all reachable IP Interfaces. TYF120 8 6T8729-02a

2 1 (1) Select an IP Interface from the list. (2) Assign a name to this new interface. The result could look like this. TYF120 9 6T8729-02a

3.2 in ETS4 In ETS4 select Settings Communication. In the window select the New button. Click on Type. Generate a new interface and select the type KNXnet/IP. ETS4 automatically searches for all reachable IP Interfaces. - Select an IP Interface from the list. - Assign a name to this new interface. TYF120 10 6T8729-02a

The result could look like this. TYF120 11 6T8729-02a

4. Setting the additional individual address of the IP Interface 4.1 in ETS3 For a stable communication with the IP Interface via KNXnet/IP Tunneling a additional individual address must be set using ETS3. Click on Settings. ETS3 fetches the current setting of the additional individual address from the IP Interface. The factory setting of the additional individual address of the IP Interface is 15.15.255. Enter the desired additional individual address and acknowledge this entry by clicking on OK. ETS3 sets the value in the IP Interface and closes the window. Note When entering the additional individual address take care that this individual address is not used by another bus device. A Dummy device with this individual address should be inserted in the ETS project. TYF120 12 6T8729-02a

4.2 in ETS4 For a stable communication with the IP Interface via KNXnet/IP Tunneling a additional individual address must be set using ETS4. Click on Local settings. ETS4 fetches the current setting of the additional individual address from the IP Interface. The factory setting of the additional individual address of the IP Interface is 15.15.255. Enter the desired additional individual address and acknowledge this entry by clicking on OK. ETS4 sets the value in the IP Interface and closes the window. Note When entering the additional individual address take care that this individual address is not used by another bus device. A Dummy device with this individual address should be inserted in the ETS project. TYF120 13 6T8729-02a

TYF120 14 6T8729-02a