Series 8146/5-V37 and Series 8150/5-V37



Similar documents
Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices SolConeX 16 A Series 8570

Terminal Boxes Series 8146

Control and Distribution Boxes made of Stainless Steel Series 8150

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Linear Luminaire with LED Series EXLUX 6402/2

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Flameproof Audible Signal 115 db (A) Series YA90

Control Stations Made of Polyester Resin Series 8146

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Technical Data. Dimensions

7 Lighting Technology

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Inductive sensor NI10-M18-Y1X-H1141

Control Stations in Sheet steel or Stainless Steel Series 8125

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Cable Plug acc. to DIN EN , Form A

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Solenoid Valve Island Type 3965

Explosion proof enclosures

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Instructions for Safe Use

Electronic overload relay EF19 and EF45

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Technical Data. Dimensions

Type: DILM32 10(24V50HZ) Article No.:

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

8146/5 Series Breaker Panelboards

SEISMIC VELOCITY TRANSDUCER T1-40

Safety automation solutions

3/2-way Solenoid Valve, direct-acting, NC or NO

Type: DILM9 10(24VDC) Article No.:

A good connection. International approvals.

5SV Residual Current Protective Devices

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual motor starter MS116

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Electronic overload relay EF65, EF96 and EF146

Assisted lift operated 2/2-way solenoid valves Type EV250B

BETA Protecting SITOR Semiconductor Fuses

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Powermate Range Pitch 7.62

Technical data sheet TDS0070

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Solenoid valves 2/2-way direct-operated Type EV210A

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Safety detection solutions

Operating Instructions

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

Bimetallic Overload Relay Specifications

HERZ-Thermal Actuators

2.12. page Products for Explosion hazardous Environment

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

R.C.C.B. s two-pole LEXIC

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

9 Control Equipment. Control Button Series 8082

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Operating Instructions

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Catalog. Modular DIN rail components Installation contactors

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Technicaldata General

System pro M compact Miniature Circuit Breaker S 200/S 200 M

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Terminal Box. Specifications TNCN

Thermal-Magnetic Circuit Breaker M1-..

MINI MCR-SL-R-UI(-SP)

Rittal TopTherm fan-and-filter unit

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

How To Read A Pipe From A Sensor

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Vario-Series Accessories

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Transcription:

www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection > Forced opening of the main contacts (load break switch) > Can be locked 3 padlocks in 0-position > High corrosion resistance of the outer components > Version according to IEC/EN 62626-1 class 1 Series 8146/5-V37 and Series 8150/5-V37 14365E00 Safety switches ensure that the machines and installations are inevitably disconnected from the energy supply during cleaning and repair work. The usual preparatory work that may only be carried out by qualified electricians can be omitted. The safety switches can be used both conventional drives and drives controlled by frequency converters. In addition to use conventional drives, the safety switches are also suitable for use drives controlled by frequency converters. When doing so, ensure that an auxiliary contact these functions (NO: ON delayed; OFF is used. The required time parameters must also be checked. The area of application lies in the frequency range from 5 to 400 Hz; the rated operating current must be adjusted accordingly. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use in x x x x For use in x For use in x WebCode 8146L Load Disconnect Switches and Motor Starters /1

Explosion Protection Global (IECEx) Gas and dust 8146/5: IECEx PTB 06.0090, 8150/5: IECEx PTB 09.0049 8146/5: Ex d e ia/ib [ia Ga] mb q IIA, IIB, IIC T6, T5, T4 Gb 8150/5: Ex d e ia/ib [ia Ga] mb q IIA, IIB, IIC T6, T5, T4, T3 Gb 8146/5: Ex tb IIIA, IIIB, IIIC T80 C, T95 C, T130 C Db 8150/5: Ex tb IIIC T80 C, T95 C, T130 C, T135 C Db Europe (ATEX) Gas and dust 8146/5: PTB 01 ATEX 1024, 8150/5: PTB 09 ATEX 1109 8146/5: E II 2 G Ex d e ia ib [ia Ga] mb q IIA, IIB, IIC T6, T5, T4 Gb 8150/5: E II 2 G Ex d e ia/ib [ia Ga] mb q IIA, IIB, IIC T6, T5, T4, T3 Gb Certifications and certificates Certificates Further parameters Further information 8146/5: E II 2 D Ex tb IIIA, IIIB, IIIC T80 C, T95 C, T130 C Db IP66 8150/5: E II 2 D Ex tb IIIC T80 C, T95 C, T130 C, T135 C Db IP66 (marking on rating plate is possible) IECEx, ATEX, Kazakhstan (TR), Russia (TR), Belarus (TR) see respective certifcate and operating instructions Selection Table Version Enclosure material Equipment Cable dia. range [mm] Switch Order number Weight Colour Additional device kg 10 A, 3-pole black 2 x 7 to 17 (M25), 8146/5-V37-300-50-0050 1.700 2 x 7 to 17 (M25), 8146/5-V37-300-50-1050 1.700 Design 10 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover V37: In switching position ON removable, in OFF position locked Handle Can be locked 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main contacts Rated operational voltage 690 V AC Rated insulation voltage 750 V Rated impulse 6 kv stand voltage Rated operational current 10 A Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 U e I P 230 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 10 A 10 A 10 A 10 A 10 A DC-1 2.2 kw 4.0 kw 4.0 kw 5.5 kw 7.5 kw DC-13 (L/R = 300 ms) U e I U e I 220 V 6 A 3) 230 V 0.4 A 1 conducting path 110 V 6 A 60 V 6 A 24 V 10 A 2 conducting paths in series 3) 3 conducting paths in series /2 Load Disconnect Switches and Motor Starters

Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary contacts Rated operating voltage Rated operational current Switch Terminals 40,000 operations, tripping characteristic: gg acc. to IEC/EN 60291-1 400 V AC 6 A advanced) 2,5... 4 mm 2 finely stranded / solid wire Ambient condition No. of poles max. current [A] Conductor cross-section [mm 2 ] Temperature class / Perm. Main contacts Auxiliary contacts min. max. ambient temperature 300-... 3 1 10 2.5 4 T6: -40 to +51 C T6: -40 to +54 C T5: -40 to +69 C Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance VDE 0298-3. only heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Selection Table Version Enclosure material 12 /, 3-pole Equipment Colour Additional device Cable dia. range [mm] 2 x 7 to 17 (M25), 2 x 7 to 17 (M25), 2 x 7 to 17 (M25), 2 x 7 to 17 (M25), Switch Order number Weight Design 12 / Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover V37: In switching position ON removable, in OFF position locked Handle Can be locked 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main contacts Rated operational voltage 690 V AC Rated insulation voltage 750 V Rated impulse 6 kv stand voltage Rated operational current 12 / kg 8146/5-V37-301-50-0050 0.962 8146/5-V37-301-50-0150 0.982 8146/5-V37-301-50-1050 0.958 8146/5-V37-301-50-1150 0.978 Load Disconnect Switches and Motor Starters /3

Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 AC-3 U e I P I P 230 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 12 A 12 A 12 A 12 A 12 A 3.0 kw 5.5 kw 5.5 kw 7.5 kw 7.5 kw 4.0 kw 7.5 kw 7.5 kw 7.5 kw 11.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary contacts Rated operating voltage Rated operational current Switch Terminals DC-1 DC-13 (L/R = 300 ms) U e I U e I 220 V 6 A 3) 230 V 0.4 A 1 conducting path 110 V 6 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 6 A 24 V 10 A 40.000 operations 25 A (I e = ); (I e = 12 A), tripping characteristic: gg acc. to IEC/EN 60291-1 400 V AC 6 A advanced) 1.5 / 1.5... 2.5 / 4 mm 2 finely stranded / solid wire Ambient condition No. of poles max. current [A] Conductor cross-section [mm 2 ] Temperature class / Perm. ambient temperature Main contacts Auxiliary contacts min. max. 301-... 3 1 12 / 16 2.5 4 T6: -40 to +51 C T6: -40 to +54 C T5: -40 to +69 C Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance VDE 0298-3. only heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate /4 Load Disconnect Switches and Motor Starters

Selection Table Version Enclosure material Equipment Cable dia. range [mm] Switch Order number Weight Colour Additional device kg, 3-pole stainless steel 1.4404 stainless steel 1.4404 black 2 x 7 to 17 (M25), 2 x 7 to 17 (M25), 8150/5-V37-302-50-0010 3.250 8150/5-V37-302-50-1010 3.250 black black 2 x 7 to 17 (M25), brass plate for 2 x M25, 1 x M20 8146/5-V37-302-50-0050 1.590 8146/5-V37-302-50-0040 1.530 2 x 7 to 17 (M25), 2 x 7 to 17 (M25), 8146/5-V37-302-50-1050 1.590 8146/5-V37-302-50-1150 1.590, 6-pole black 4 x 7 to 17 (M25), 4 x 7 to 17 (M25), 2 NO (1 x ON delayed - OFF eading) 2 NO (1 x ON delayed - OFF 8146/5-V37-602-60-1010 2.640 8146/5-V37-602-60-0010 2.640 Design Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover V37: In switching position ON removable, in OFF position locked Handle Can be locked 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main contacts Rated operational voltage 690 V AC Rated insulation voltage 690 V Rated impulse 6 kv stand voltage Rated operational current Load Disconnect Switches and Motor Starters /5

Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 U e I P 230 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 4.0 kw 7.5 kw 7.5 kw 7.5 kw 11.0 kw Auxiliary contacts Service life of electrical / mechanical parts Max. short-circuit protection DC-1, DC-23 DC-13 (L/R = 300 ms) U e I U e I 220 V 3) 250 V 1.1 A 1 conducting path 120 V 125 V 2.2 A 60 V 60 V 5.0 A 40.000 operations 25 A, tripping characteristic: gg acc. to IEC/EN 60291-1 2 conducting paths in series 3) 3 conducting paths in series Rated operating voltage Rated operational current Switch Terminals 400 V AC 10 A 3-pole: advanced) 6-pole: 2 NO (1 x ON advanced / 1 x switching normally) 2.5... 10 mm 2 finely stranded / solid Ambient condition No. of poles max. current [A] Conductor cross-section [mm 2 ] Temperature class / Perm. ambient temperature Main contacts Auxiliary contacts min. max. 302-... 3 1 16 2.5 6 T6: -40 to +51 C T6: -40 to +54 C T5: -40 to +69 C 302-...-.5 3 0 16 2.5 10 T4: -40 to +60 C 602-... 6 2 16 2.5 6 T6: -40 to +47 C T5: -40 to +62 C 8150/5-V..- 302-... 3 1 16 2.5 6 T6: -40 to +50 C T6: -40 to +65 C Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance VDE 0298-3. only heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Selection Table Version Enclosure material Equipment Cable dia. range [mm] Switch Order number Weight Colour Additional device kg 20 A, 3-pole black 2 x 7 to 17 (M25), 8146/5-V37-303-50-0010 2.020 2 x 7 to 17 (M25), 8146/5-V37-303-50-1010 2.020 /6 Load Disconnect Switches and Motor Starters

Design 20 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover Handle V37: In switching position ON removable, in OFF position locked Can be locked 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main contacts Rated operational voltage 690 V AC Rated insulation voltage 690 V Rated operational current 20 A Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 U e I P 230 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 20 A 20 A 20 A 20 A 20 A 5.5 kw 7.5 kw 11.0 W 11.0 kw 18.5 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary contacts Rated operating voltage Rated operational current Terminals DC-1, DC-23 DC-13 (L/R = 300 ms) U e I U e I 220 V 20 A 3) 250 V 1.1 A 1 conducting path 120 V 20 A 125 V 2.2 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 20 A 60 V 5.0 A 40.000 operations 35 A, tripping characteristic: gg acc. to IEC/EN 60291-1 500 V AC 10 A 4... 6 mm 2 finely stranded / solid Load Disconnect Switches and Motor Starters /7

Ambient condition No. of poles max. current [A] Conductor cross-section [mm 2 ] Temperature class / Perm. ambient temperature Main contacts Auxiliary contacts min. max. 303-... 3 1 20 4 6 T6: -40 to +40 C T5: -40 to +55 C 603-... 6 2 20 4 6 T6: -40 to +41 C T5: -40 to +56 C 6 2 20 6 6 T6: -40 to +42 C T5: -40 to +50 C T5: -40 to +57 C 6 0 20 4 6 T6: -40 to +46 C T5: -40 to +61 C T5: -40 to +52 C 6 0 20 6 6 T5: -40 to +52 C T5: -40 to +48 C 8150/5-V..- 303-... 3 1 20 4 6 T6: -40 to +42 C T5: -40 to +57 C 3 1 20 6 6 T6: -40 to +43 C T5: -40 to +58 C T5: -40 to +53 C Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance VDE 0298-3. only heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Selection Table Version Enclosure material Equipment Cable dia. range [mm] Switch Order number Weight Colour Additional device kg 25 A, 3-pole stainless steel 1.4404 2 x 9 to 21 (M3, 8150/5-V37-304-50-0010 3.300 stainless steel 1.4404 2 x 9 to 21 (M3, 8150/5-V37-304-50-1010 3.300 2 x 9 to 21 (M3, 8146/5-V37-304-50-0010 1.960 2 x 9 to 21 (M3, 8146/5-V37-304-50-1010 2.020 2 x 9 to 21 (M3, 8146/5-V37-304-50-1110 2.020 25 A, 6-pole 4 x 7 to 17 (M25), 2 NO (1 x ON 8146/5-V37-604-60-0010 2.790 4 x 7 to 17 (M25), 2 NO (1 x ON 8146/5-V37-604-60-1010 2.790 /8 Load Disconnect Switches and Motor Starters

Design 25 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover Handle V37: In switching position ON removable, in OFF position locked Can be locked 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main contacts Rated operational voltage 690 V AC Rated insulation voltage 690 V Rated operational current 25 A Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 AC-23 U e I P I P 230 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 25 A 25 A 25 A 25 A 5.5 kw 11.0 kw 11.0 kw 15.0 kw 25 A 22.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary contacts Rated operating voltage Rated operational current Terminals 120 V 25 A 125 V 2.2 A 60 V 25 A 60 V 5.0 A 40.000 operations 35 A, tripping characteristic: gg acc. to IEC/EN 60291-1 500 V AC 10 A DC-1, DC-23 4... 6 mm 2 finely stranded / solid DC-13 (L/R = 300 ms) U e I U e I 220 V 25 A 3) 250 V 1.1 A 1 conducting path 2 conducting paths in series 3) 3 conducting paths in series Load Disconnect Switches and Motor Starters /9

Ambient condition No. of poles max. current [A] Conductor cross-section [mm 2 ] Temperature class / Perm. ambient temperature Main contacts Auxiliary contacts min. max. 304-... 3 1 25 4 6 T6: -40 to +40 C T5: -40 to +55 C 604-... 6 2 25 4 6 T5: -40 to +49 C 6 2 25 6 6 T6: -40 to +42 C T5: -40 to +50 C T5: -40 to +57 C 6 0 25 4 6 T5: -40 to +45 C 6 0 25 6 6 T5: -40 to +52 C T5: -40 to +48 C 8150/5-V..- 304-... 3 1 25 4 6 T5: -40 to +50 C 3 1 25 6 6 T6: -40 to +43 C T5: -40 to +58 C T5: -40 to +53 C Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance VDE 0298-3. only heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Selection Table Version Enclosure material Equipment Cable dia. range [mm] Switch Order number Weight Colour Additional device kg 40 A, 3-pole 2 x 12 to 28 (M40), 8146/5-V37-305-00-0010-K 5.560 2 x 12 to 28 (M40), 8146/5-V37-305-51-0010-K 5.560 2 x 12 to 28 (M40), 8146/5-V37-305-51-1010-K 4.620 stainless steel 1.4404 2 x 12 to 28 (M40), 8150/5-V37-305-51-0010-K 8.360 stainless steel 1.4404 2 x 12 to 28 (M40), 8150/5-V37-305-51-1010-K 8.360 2 x 12 to 28 (M40), 8146/5-V37-305-51-1110-K 18.500 main contact on terminal 2 x 12 to 28 (M40), 8146/5-V37-305-00-1510 7.500 40 A, 6-pole black 4 x 12 to 28 (M40), 8146/5-V37-605-00-0010-K 10.960 black 4 x 12 to 28 (M40), 8146/5-V37-605-51-0010-K 10.960 4 x 12 to 28 (M40), 8146/5-V37-605-51-1010-K 10.960 /10 Load Disconnect Switches and Motor Starters

Design 40 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover Handle V37: In switching position ON removable, in OFF position locked Can be locked 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main contacts Rated operational voltage 690 V AC Rated insulation voltage 750 V Rated operational current 40 A Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 U e I P 240 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 40 A 40 A 40 A 40 A 40 A 11.0 kw 22.0 kw 22.0 kw 22.0 kw 37.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary contacts Rated operating voltage Rated operational current Terminals DC-23, DC-1 U e I 220 V 40 A 3) 1 conducting path 120 V 40 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 40 A 40.000 operations 80 A, tripping characteristic: gg acc. to IEC/EN 60291-1 500 V AC 6 A 1.5... 2.5 mm 2 finely stranded / solid Ambient condition No. of poles max. current [A] Conductor cross-section [mm 2 ] Temperature class / Perm. ambient temperature Main contacts Auxiliary contacts min. max. 305-...-K 3 2 40 10 25 T6: -40 to +48 C 305-00-...-K 3 0 T6: -40 to +51 C T5: -40 to +66 C 305-..-.5 3 0 40 10 35 T4: -40 to +60 C 605-...-K 6 2 40 10 25 T6: -40 to +47 C 605-00-...-K 6 0 T5: -40 to +51 C T5: -40 to +62 C 8150/5-V..- 305-...-K 3 2 40 10 25 T6: -40 to +45 C T5: -40 to +49 C T5: -40 to +60 C 605-...-K 6 2 40 10 25 T6: -40 to +46 C T5: -40 to +48 C T5: -40 to +61 C Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance VDE 0298-3. only heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Load Disconnect Switches and Motor Starters /11

Selection Table Version 63 / 80 A, 3-pole 63 / 80 A, 3-pole, compact *) 63 / 80 A, 6-pole Note Design Enclosure material stainless steel 1.4404 stainless steel 1.4404 Equipment Colour black protective Additional device Cable dia. range [mm] 2 x 16 to 35 (M50), 2 x 16 to 35 (M50), brass plate 2 x 16 to 35 (M50), 2 x 16 to 35 (M50), 2 x 16 to 35 (M50), 2 x 16 to 35 (M50), 2 x 16 to 35 (M50), main contact on terminal 2 x 16 to 35 (M50), 2 x 16 to 35 (M50), 2 x 16 to 35 (M50), 2 x 16 to 35 (M50), 2 x 16 to 35 (M50), 4 x 16 to 35 (M50), 4 x 16 to 35 (M50), 4 x 16 to 35 (M50), *) K versions a smaller design size; see dimensional drawings 63 / 80 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover Handle Switch Order number Weight 8146/5-V37-306-00-0010 8.060 OFF, OFF, OFF, OFF, OFF, OFF, kg 8146/5-V37-306-51-0010 7.960 8146/5-V37-306-51-0040 11.800 8146/5-V37-306-51-1010 7.550 8146/5-V37-306-51-1110 7.550 8150/5-V37-306-51-0010-K 12.600 8150/5-V37-306-51-1010-K 12.600 8146/5-V37-306-00-1510 10.700 8146/5-V37-306-00-0010-K 5.680 OFF, OFF, OFF, 8146/5-V37-306-51-0010-K 5.680 8146/5-V37-306-51-1010-K 5.680 8146/5-V37-306-51-1110-K 5.680 8146/5-V37-606-00-0010 10.100 OFF, OFF, V37: In switching position ON removable, in OFF position locked Can be locked 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal 8146/5-V37-606-51-0010 10.100 8146/5-V37-606-51-1010 10.100 /12 Load Disconnect Switches and Motor Starters

Main contacts Rated operational voltage 500 V AC (80 A) / 690 V AC (63 A) Rated insulation voltage Rated operational current 750 V 63 / 80 A Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 AC-3 U e I P I P 230 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 63 A 63 A 63 A 63 A 63 A 18.5 kw 30.0 kw 37.0 kw 37.0 kw 55.0 kw 80 A 80 A 80 A 80 A 22.0 kw 45.0 kw 45.0 kw 55.0 kw DC-23, DC-1 U e I 220 V 80 A 3) 1 conducting path 120 V 80 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 80 A Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary contacts Rated operating voltage Rated operational current Terminals 40.000 operations 63 A: 125 A, 80 A: 160 A, tripping characteristic: gg according to IEC/EN 60291-1 500 V AC 6 A 1.5... 2.5 mm 2 finely stranded / solid Ambient condition No. of poles max. current [A] Conductor cross-section [mm 2 ] Temperature class / Perm. ambient temperature Main contacts Auxiliary contacts min. max. 306-...-K 3 2 50 10 25 T6: -40 to +43 C 3 2 63 16 25 T6: -40 to +42 C T5: -40 to +57 C 3 2 80 25 25 T6: -40 to +40 C T5: -40 to +44 C T5: -40 to +55 C 306-00-...-K 3 0 50 10 25 T6: -40 to +43 C 3 0 63 16 25 T6: -40 to +42 C T5: -40 to +57 C 3 0 80 25 25 T6: -40 to +40 C T5: -40 to +44 C T5: -40 to +55 C 306-... 3 2 63 35 50 T6: -40 to +58 C T5: -40 to +73 C 3 2 63 50 50 T6: -40 to +60 C T5: -40 to +75 C 3 2 80 35 50 T6: -40 to +48 C T5: -40 to +53 C T5: -40 to +63 C 3 2 80 50 50 T6: -40 to +53 C T5: -40 to +57 C T5: -40 to +68 C Load Disconnect Switches and Motor Starters /13

Ambient condition No. of poles max. current [A] Conductor cross-section [mm 2 ] Temperature class / Perm. ambient temperature Main contacts Auxiliary contacts min. max. 306-00-... 3 0 63 35 50 T6: -40 to +58 C T5: -40 to +73 C 3 0 63 50 50 T6: -40 to +60 C T5: -40 to +75 C 3 0 80 35 50 T6: -40 to +48 C T5: -40 to +53 C T5: -40 to +63 C 3 0 80 50 50 T6: -40 to +53 C T5: -40 to +57 C T5: -40 to +68 C 306-..-.5 3 0 63 25 95 T4: -40 to +60 C 307-..-.5 3 0 80 50 150 T4: -40 to +60 C 406-...-K 4 0 63 35 50 T6: -40 to +55 C T5: -40 to +70 C 4 0 63 50 50 T6: -40 to +57 C T5: -40 to +72 C 4 0 80 35 50 T6: -40 to +45 C T5: -40 to +50 C T5: -40 to +60 C 4 0 80 50 50 T6: -40 to +50 C T5: -40 to +54 C T5: -40 to +65 C 606-... 6 2 50 10 50 T6: -40 to +41 C T5: -40 to +56 C 6 2 63 16 50 T6: -40 to +41 C T5: -40 to +56 C 6 2 63 25 50 T6: -40 to +47 C T5: -40 to +62 C 6 2 80 25 50 T5: -40 to +51 C 6 2 80 35 50 T6: -40 to +43 C T5: -40 to +58 C 606-00-... 6 0 50 10 50 T6: -40 to +41 C T5: -40 to +56 C 6 0 63 16 50 T6: -40 to +41 C T5: -40 to +56 C 6 0 63 25 50 T6: -40 to +47 C T5: -40 to +62 C 6 0 80 25 50 T5: -40 to +51 C 6 0 80 35 50 T6: -40 to +43 C T5: -40 to +58 C /14 Load Disconnect Switches and Motor Starters

8150/5-V..- 306-...-K 3 2 63 16 50 T5: -40 to +50 C T5: -40 to +46 C 3 2 63 25 50 T6: -40 to +42 C T5: -40 to +51 C T5: -40 to +57 C 3 2 80 25 50 T5: -40 to +47 C T5: -40 to +43 C 3 2 80 25 50 T6: -40 to +40 C T5: -40 to +41 C T5: -40 to +55 C 606-... 6 2 50 16 50 T6: -40 to +45 C T5: -40 to +60 C 6 2 63 16 50 T5: -40 to +46 C T5: -40 to +42 C 6 2 63 25 50 T6: -40 to +43 C T5: -40 to +47 C T5: -40 to +58 C 6 2 80 25 50 T5: -40 to +41 C Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance VDE 0298-3. only heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Load Disconnect Switches and Motor Starters /15

Selection Table Version Enclosure material Equipment Cable dia. range [mm] Switch Order number Weight Colour Additional device kg 125 / 160 A, 3-pole 2 x 28 to 48 M63, 1 x 4 to 13 M20 8146/5-V37-308-00-0010 18.500 8146/5-V37-308-51-0010 18.500 brass plate 2 x 28 to 48 M63, 1 x 4 to 13 M20 8146/5-V37-308-51-0040 22.770 8146/5-V37-308-51-1010 18.500 2 x 28 to 48 (M63), 8146/5-V37-308-51-1110 23.200 125 / 160 A, 3-pole, compact *) 8146/5-V37-308-00-0010-K 14.350 8146/5-V37-308-51-0010-K 14.350 stainless steel 1.4404 2 x 28 to 48 M63, 1 x 4 to 13 M20 2 NO (1 x ON 8150/5-V37-308-51-0010-K 25.625 brass plate 2 x 28 to 48 M63, 1 x 4 to 13 M20 8146/5-V37-308-51-0040-K 21.260 8146/5-V37-308-51-1010-K 14.350 stainless steel 1.4404 2 x 28 to 48 M63, 1 x 4 to 13 M20 8150/5-V37-308-51-1010-K 25.625 2 x 28 to 48 (M63), 8146/5-V37-308-51-1110-K 14.350 125 / 160 A, 6-pole 4 x 28 to 48 (M63), 8146/5-V37-608-00-0010 22.760 4 x 28 to 48 (M63), 8146/5-V37-608-51-0010 22.760 4 x 28 to 48 (M63), 8146/5-V37-608-51-1010 22.760 4 x 28 to 48 (M63), 8146/5-V37-608-51-1110 22.760 /16 Load Disconnect Switches and Motor Starters

Selection Table Version 180 A, 3-pole 180 A, 3-pole, compact *) 180 A, 6-pole Note Enclosure material Equipment Colour Additional device brass plate 2 x 28 to 48 M63, 1 x 4 to 13 M20 2 x 28 to 48 (M63), brass plate 2 x 28 to 48 M63, 1 x 4 to 13 M20 2 x 28 to 48 (M63), 4 x 28 to 48 (M63), 4 x 28 to 48 (M63), brass plate 4 x 28 to 48 M63, 1 x 4 to 13 M20 4 x 28 to 48 (M63), Cable dia. range [mm] 4 x 28 to 48 (M63), *) K versions a smaller design size; see dimensional drawings Switch Order number Weight 8146/5-V37-310-00-0010 19.560 8146/5-V37-310-51-0010 19.560 8146/5-V37-310-51-0040 22.770 8146/5-V37-310-51-1010 19.560 8146/5-V37-310-51-1110 19.560 8146/5-V37-310-00-0010-K 14.360 8146/5-V37-310-51-0010-K 14.360 8146/5-V37-310-51-0040-K 15.140 8146/5-V37-310-51-1010-K 14.360 8146/5-V37-310-51-1110-K 14.360 8146/5-V37-610-00-0010 37.360 8146/5-V37-610-51-0010 37.360 8146/5-V37-610-51-0040 kg 8146/5-V37-610-51-1010 37.360 8146/5-V37-610-51-1110 37.360 Load Disconnect Switches and Motor Starters /17

Design 125 / 160 / 180 A Degree of protection IP66 acc. to IEC/EN 60529 Enclosure cover Handle V37: In switching position ON removable, in OFF position locked Can be locked 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main contacts Rated operational voltage 400 V AC (180 A) / 500 V AC (150 A) / 690 V AC (125 A) Rated insulation voltage 750 V Rated operational current 125 / 160 / 180 A Switching capacity acc. to IEC/EN 60947-3; DIN VDE 0660, part 107 AC-3 AC-3 AC-3 U e I P I P I P 230 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 180 A 180 A 55.0 kw 90.0 kw 160 A 160 A 160 A 45.0 kw 90.0 kw 90.0 kw 125 A 125 A 125 A 125 A 125 A 37.0 kw 55.0 kw 75.0 kw 75.0 kw 110.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary contacts Rated operating voltage Rated operational current Terminals DC-23, DC-1 U e I 220 V 180 A 3) 1 conducting path 120 V 180 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 180 A 40.000 operations 125 A: max. 200 A / 690 V max. 250 A / 500 V 160 A / 180 A: max. 250 A / 400 V tripping characteristic: gg acc. to IEC/EN 60291-1 500 V AC 6 A 1.5... 2.5 mm 2 finely stranded / solid /18 Load Disconnect Switches and Motor Starters

Ambient condition No. of poles max. current [A] Conductor cross-section [mm 2 ] Temperature class / Perm. ambient temperature Main contacts Auxiliary contacts min. max. 308-...-K 3 1 125 95 120 T6: -40 to +46 C T5: -40 to +62 C T4: -40 to +72 C 3 1 125 120 120 T6: -40 to +50 C T5: -40 to +65 C T4: -40 to +72 C 308-... 3 1 125 95 150 T6: -40 to +47 C T5: -40 to +62 C T4: -40 to +72 C 608-... 6 2 125 95 150 T6: -40 to +40 C T5: -40 to +55 C T4: -40 to +72 C 8150/5-V..- 308-...-K 3 1 125 95 120 T5: -40 to +50 C T4: -40 to +63 C 3 1 125 120 120 T5: -40 to +44 C T5: -40 to +59 C T4: -40 to +68 C 308-...-K 3 1 160 95 120 T5: -40 to +40 C T5: -40 to +50 C T4: -40 to +55 C 3 1 160 120 120 T5: -40 to +45 C T5: -40 to +49 C T4: -40 to +60 C 308-... 3 1 160 95 150 T5: -40 to +40 C T5: -40 to +47 C T4: -40 to +55 C 3 1 160 120 150 T5: -40 to +45 C T5: -40 to +51 C T4: -40 to +60 C 608-... 6 2 160 95 150 T4: -40 to +40 C T4: -40 to +55 C 8150/5-V..- 6 2 160 120 150 T4: -40 to +45 C T4: -40 to +55 C 308-...-K 3 1 160 95 120 T4: -40 to +44 C 3 1 160 120 120 T5: -40 to +41 C T5: -40 to +51 C 310-...-K 3 1 180 95 120 T4: -40 to +40 C 3 1 180 120 120 T4: -40 to +50 C 310-... 3 1 180 95 150 T4: -40 to +40 C 3 1 180 120 150 T4: -40 to +50 C 610-... 6 2 180 120 150 T4: -40 to +50 C Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance VDE 0298-3. only heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Load Disconnect Switches and Motor Starters /19

Dimensional Drawings (All dimensions in mm) Subject to alterations B C A 04120E00 3-pin 10, 12 / 8146/5-V37-300-50-... 8146/5-V37-301-50-... 8146/5-V37-302-50-... 8146/5-V37-302-..-.5.. 8150/5-V37-302-50-... 8146/5-V37-302-50-0250 Dimensions [mm] A B C 112.5 112.5 170 340.5 176.5 227 112.5 112.5 112.5 170 176.5 112.5 20 A 8146/5-V37-303-50-... 170 170 132 25 A 8146/5-V37-304-50-... 8150/5-V37-304-50-... 40 A 8146/5-V37-305-...-K 8146/5-V37-305-..-.5.. 8150/5-V37-305-...-K 63 / 80 A 8146/5-V37-306-...-K 8146/5-V37-306-... 8146/5-V37-306-..-.5.. 8150/5-V37-306-S1-... 170 176.5 340.5 340.5 360 340.5 340.5 681.5 360 170 176.5 170 340.5 176.5 170 340.5 340.5 360 80 A 8146/5-V37-307-..-.5.. 681.5 340.5 195 125 / 160 A 8146/5-V37-308-..-K 8146/5-V37-308-... 180 A 8146/5-V37-310-..-K 8146/5-V37-310-... 681.5 681.5 681.5 681.5 340.5 681.5 340.5 681.5 6-pin 8146/5-V37-602-60-... 170 170 172 25 A 8146/5-V37-604-60-... 227 170 172 40 A 8146/5-V37-605-...-K 340.5 340.5 205 63 / 80 A 8146/5-V37-606-... 681.5 340.5 205 125 / 160 A 8146/5-V37-608-... 1,023 681.5 243 180 A 8146/5-V37-610-... 1,023 681.5 243 131 131 132 132 132 172 132 132 176.5 195 194 195 195 195 196 205 205 205 205 Enclosure and sealing material 8146/5-V.. 8150/5-V.. Enclosure, glass-fibre-reinforced, dark-grey, similar to RAL 7024 Impact resistance ) 7 J surface resistance ( 10 9 Ω flame retardant acc. IEC/EN 60695, UL 94, ASTM D635 stainless steel 1.4404 (AISI 316L), brush finished Seal silocone, foamed, optional EPDM silicone, foamed Circuit diagrams 0 90 1 3 5 7 9 01 13 23 0 90 1 3 5 2 4 6 8 10 02 14 24 2 4 6 15622E00 15581E00 -V..-6..-60-.. 6-pin + 1 NO (1x ON leading / 1 x switching normally) -V..-3..-00-.. 3-pin 0 90 1 3 5 7 9 01 2 4 6 8 10 02 15579E00 -V..-6..-00-.. 6-pin /20 Load Disconnect Switches and Motor Starters

Accessories and Spare Parts Designation Figure Description Note Art. no. Weight Auxiliary contact (for the versions 40 A and higher) 12446E00 2 NC contacts (8080/1-3) 168356 0.026 contact + 1 NO contact 168351 0.026 (8080/1-2 NO contacts (8080/1-4) 168353 0.026 The switching function of the auxiliary contact depends on the installation slot used. Left: delayed (ON), leading (OFF); Right: synchronising Left and right: synchronising Note: The auxiliary contacts can only be retrofitted for 40A, 63/80A, 80A, 125A, 160A and 180A versions. For all other versions, the auxiliary contact must be ordered separately when placing the order. Retrofitting is not possible for this. kg Auxiliary contact key for removing the mounted auxiliary contact 201909 0.035 14151E00 Brass plates 17483E00 04902E00 for 8146/5-V37-300, 8146/5-V37-301 for 8146/5-V37-302 148207 0.355 Size 031 2xM25, 1xM20 202079 0.081 Size 041 A 2xM25 1xM20 07097E00 for 8146/5-V37-305 200215 0.190 Size 073 A/B 2xM40, 1xM20 07098E00 for 8146/5-V37-306 for 8146/5-V37-306 201948 0.370 Size 073 A/B 2xM50, 1xM20 226936 0.800 Size S73/083/093 2xM50, 1xM20 17486E00 for 8146/5-V37-308, 8146/5-V37-310 227586 0.750 Size S73/083/093 2xM63, 1xM20 17485E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available out notice. The illustrations cannot be considered binding. Load Disconnect Switches and Motor Starters /21