POLARIZING MICROSCOPE BX51-P BX2 SERIES



Similar documents
ISO9001 ISO Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

How To Use An Asbestos Microscope

MICROSCOPES & REFRACTOMETERS for laboratory, industry and food

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

The new standard in research microscopy

RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10. Macro View. The first true macro fluorescence imaging system

THE COMPOUND MICROSCOPE

LABORATORY MICROSCOPEs

Biological Microscope. Biological Microscope ECLIPSE E200

Olympus BX51 Microscope & DP70 Digital Camera System

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

Care and Use of the Compound Microscope

Measuring the Point Spread Function of a Fluorescence Microscope

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE

Leica DM4 P, DM2700 P, DM750 P

Leica DM LS2 and DM LB2. Life Science System Microscopes with New Ergonomic Concept

Compound microscope (Hund)

Crystal Optics of Visible Light

MICROSCOPY MARKETING GUIDE

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Product Range Overview

Rodenstock Photo Optics

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

microscope OP-Dent-5

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Inverted Microscope. Inverted Microscope ECLIPSE TS100

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Automatic and Objective Measurement of Residual Stress and Cord in Glass

FIXED STAGE UPRIGHT MICROSCOPE BX51WI FIXED STAGE UPRIGHT MICROSCOPE WITH MOTORIZED FOCUSING BX61WI UNIVERSAL INFINITY SYSTEM

Leica MZ125. Modular high-performance stereomicroscope with 12.5:1 zoom

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Physics 441/2: Transmission Electron Microscope

euromex microscopen bv The Netherlands page1/16

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Master Anamorphic T1.9/35 mm

Endoscope Optics. Chapter Introduction

Firearms & Tool Marks Comparison Microscope. Discovery. Leeds Forensic Systems. Your Forensic Imaging Source

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

EXPERIMENT #1: MICROSCOPY

LEICA TRI-ELMAR-M mm f/4 ASPH. 1

Leica DM500 & DM750. A New Generation s Choice of Innovative Educational Microscopes

SERIE SZR. Stereomicroscopi da laboratorio. 13

Diffraction of Laser Light

Optical laser beam scanner lens relay system

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

UIS OBJECTIVES FOR LIFE SCIENCE UNIVERSAL INFINITY SYSTEM

Infrared Viewers. Manual

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

Forensic Science: The Basics. Microscopy

MACRO PHOTO LENS. MP-E 65mm f/ ENG. Instruction

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

Apo-Nikkor and Process-Nikkor large format lenses by Daniel W. Fromm

Application Report: Running µshape TM on a VF-20 Interferometer

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide

digital quality control fail pass at your fingertips Smart Metrology Solutions.

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

The upright transmitted microscope is most suited to our purpose of observing samples of compost, soil and compost tea, etc.

OPTICAL MICROSCOPY OPTICAL MICROSCOPY

The Kaps SOM -Series. Stereo Examination Microscopes for ENT Specialists. The variable space-saving system for every ENT practice

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Solution Derivations for Capa #14

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Lenses and Apertures of A TEM

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

AxioCam HR The Camera that Challenges your Microscope

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

FUNDAMENTALS OF LIGHT MICROSCOPY AND ELECTRONIC IMAGING

Review: Amscope Metallurgical Trinocular Microscope. Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA

PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES

VICKERS HARDNESS TESTER. HBS HBW Kc

OLYMPUS SYSTEM MICROSCOPE. Model BHT OLYMPUS

Contents. Introduction 2. Features and Benefits 3. Freeform Design Range 10. Custom 14/16/ Custom U 15. Custom V 17.

Dental Solutions. Mach LED 2SC Hybrid Mach LED 3SC with video system Mach LED 130 Dental Mach LED 150

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

POLARIZED LIGHT MICROSCOPE EXAMINATIONS OF ORIENTED POLYMER FILMS

Microscopes 2014 Microscopes PB Microscopes 1

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY

EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS

Light and Sound. Pupil Booklet

Software-based three dimensional reconstructions and enhancements of focal depth in microphotographic images

Profile Projector PH-3500

Cataract l Glaucoma l Retina l Refractive. VISULAS YAG III. The Fastest YAG Laser. Laser Precision Par Excellence.

Ektalite Slide Projectors

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffraction of a Circular Aperture

ZEISS Compact Prime and Zoom lenses Flexibility and performance in a winning combination.

GLobAL Dental Microscopes. Dentists First Choice

A concise guide to Safety Glasses, the different standards and the effects of light on the eye. Contents. Links. Year of publication: 2010

Flat-Field IR Mega-Pixel Lens

Transcription:

POLARIZING MICROSCOPE BX51-P BX2 SERIES

Unsurpassed optics render polarized light images sharper than ever before. Olympus is proud to introduce the BX51-P, the new polarizing microscope with superb performance in polarized light. It's a breakthrough combination of world-renowned UIS2 infinity-corrected optics and Olympus original optical-design. Olympus has also devised a new, extended line of compensators to make the BX51-P versatile enough to handle observation and measuring applications in virtually any field. 0.5mm * Zonal structure of Plagioclase in quartz diorite. 50µm * Optical texture of MBBA *Scales indicate actual size of samples UIS2 provides outstanding system expandability. By maximizing the advantages of infinity correction, the UIS2 optical system prevents the deterioration of optical microscope performance and eliminates magnification factors, even when polarizing elements like analyzers, tint plates or compensators are introduced into the light path. Maintaining the highest level of system flexibility, the BX51-P also accepts intermediate attachments available for the BX2 Series system microscopes, as well as cameras and digital imaging systems. BX51 Conoscopic/ Orthoscopic configuration BX51 Orthoscopic configuration

Enhanced operational ease and outstanding optical performance. LWith the U-CPA conoscopic observation attachment, the changeover between orthoscopic and conoscopic observation methods is simple and quick just slide the Bertrand lens control knob in or out. LThe circular rotatable stage has two centering knobs and allows smooth sample rotation. A settable click stop every 45 degrees enables accurate observation and measurement. LAn ergonomic Y-shaped frame ensures comfortable, efficient observation with less fatigue, even over prolonged periods. LStandard field number F.N. 22 represents a 21% increase in field size, covered with the conventional F.N. 20. LThe high intensity 12V, 100W halogen light source combined with the UIS2 optical system and its high transmittance result in exceptionally bright and sharp images. LMounting an attachable crossmovement mechanical stage (U-FMP) onto the circular rotatable stage makes for improved observation efficiency. Interference between the mechanical stage and the objective lenses is eliminated, so that images of superb quality can be effortlessly observed with all objective lens magnification. U-FMP

BX51-P system diagram WHN10X, 35WHN10X, CROSSWHN10X Eyepieces Compensators qu-tp530, Tint Plate wu-tp137, 1/4 Wavelength Retardation Plate eu-cwe2, Quarts Wedge ru-cse, Senarmont Compensator tu-ctb, Thick Berek yu-cbe, Berek uu-cbr1, Brace-Koehler Compensator 1/10 iu-cbr2, Brace-Koehler Compensator 1/30 q w U-TR30-2 Trinocular tube U-OPA Intermediate attachment for orthoscopic observation ty ui e r U-TAD Plate adapter U-P4RE Centerable revolving nosepiece U-CPA Intermediate attachment for conoscopic and orthoscopic observation U-AN360P-2 Rotatable analyzer Objective lenses for polarising observation U-FMP Mechanical stage U-SRP Precision rotatable stage U-POC-2 Polarising condenser BX51TF BX51 transmitted frame U-LH100-3 100W halogen lamp housing BX51-P dimensions (unit: mm) 175 *187 271 175 *187 271 84 84 209 209 45 65 45 65 317.5 341 415 317.5 341 415 BX51 Orthoscopic configuration weight: approx. 15.6kg (34.4 Ibs.) BX51 Conoscopic/Orthoscopic configuration weight: approx. 16.6kg (36.6 Ibs.) Power consumption: 250VA Note: The length marked with an asterisk (*) may vary according to the interpupillary distance setting. Distance for figure is 62mm.

An upgrade in polarization characteristics. Thanks to Olympus' sophisticated design and manufacturing technology, the ACHN-P and UPLFL-P strain-free objective lenses reduce internal strain to an absolute minimum. Olympus has also totally redesigned its polarizers and polarizing condensers to further enhance performance in polarized light. This means a higher EF* value, resulting in unmatched image contrast. To meet a diversity of research and application requirements, the universal UPLFL-P Series objective lenses have been designed to accommodate a wide range of observation methods, including Nomarski DIC and fluorescence microscopy, in addition to polarized light observation. *The EF (extinction factor) is the brightness ratio between parallel and crossed pol-filters. The higher the EF value, the better the extinction. o q i w e u y r t qu-tp530 wu-tp137 eu-tad ru-cbr1 tu-cbr2 yu-cwe2 uu-cse iu-cbe ou-ctb UPLFL-P Series ACHN-P Series UPLFL-P Series Item N.A. W.D. UPLFL 4XP 0.13 13.0mm UPLFL 10XP 0.30 3.1mm UPLFL 20XP 0.50 1.6mm UPLFL 40XP 0.75 0.51mm UPLFL 100XOP 1.30 0.10mm PLN Item N.A. W.D. PLN 4XP 0.1 18.5mm ACHN-P Series Item N.A. W.D. ACHN 10XP 0.25 6.0mm ACHN 20XP 0.40 3.0mm ACHN 40XP 0.65 0.45mm ACHN 100XOP 1.25 0.13mm *All UIS2 objective lenses and WHN eyepieces: lead-free ecoglass An extensive range of compensators is available. Six different compensators are available for the BX51-P microscope, allowing measurement of various retardation levels, ranging from 0 to 20λ. For easier Measuring range of compensators Compensator Measurement range Applications qu-cpa wu-p4re eu-an360p-2 ru-opa tu-poc-2 measurement, the direct readout method is featured. Higher image contrast can be attained by using a Senarmont* or Brace- Koehler compensator to change the retardation level in the entire field of view. * Used with monochromatic green filter, IF546 or IF550. Thick Berek (U-CTB) 0-11,000nm (20λ) Measurement of high retardation level (R*>3λ), (crystals, macromolecules, fiber, etc.) Berek (U-CBE) 0-1,640nm (3λ) Measurement of retardation level (crystals, macromolecules, living organisms, etc.) Senarmont compensator (U-CSE) 0-546nm (1λ) Measurement of retardation level (crystals, living organisms, etc.) Enhancement of image contrast (living organisms, etc.) Brace-Koehler compensator 1/10λ (U-CBR1) 0-55nm (1/10λ) Measurement of low retardation level (living organisms, etc.) Brace-Koehler compensator 1/30λ (U-CBE2) 0-20nm (1/30λ) Enhancement of image contrast (living organisms, etc.) Quartz wedge (U-CWE2) 500-2,200nm (4λ) Approximate measurement of retardation level (crystal, macromolecules, etc.) *R= retardation level For more accurate measurement, it is recommended that compensators (expect U-CWE2) be used together with the interference filter 45-IF546. t q r w e Unmatched sharpness in orthoscopic and conoscopic observations. With a U-CPA conoscopic observation attachment, changeover between orthoscopic and conoscopic observation is simple and quick. Focusing of conoscopic images is easy and accurate. Employing a Bertrand field stop makes it possible to obtain consistently sharp and clear conoscopic images.

BX51-P specifications Polarized light intermediate attachment (U-CPA or U-OPA) Item Conoscopic and orthoscopic observation (U-CPA) Orthoscopic observation (U-OPA) F.N. 22 22 Bertrand lens Focusable Bertrand field stop ø3.4mm diameter (fixed) Engage or disengage Bertrand lens changeover between orthoscopic and conoscopic observation Position of slider [ in Position of slider _ out Analyzer slot Rotatable analyzer with slot (U-AN360P-2) Analyzer 360 dial-rotatable (U-AN360P-2) Rotatable minimum angle 0.1 Revolving centerable nosepiece Quadruple, centerable attachable components: 1/4 wavelength retardation plate (U-TAD), (U-P4RE) tint plate (U-TP530) and various compensators can be attached using plate adapter (U-TAD) Stage (U-SRP) Condenser (U-POC-2) Polarizing rotatable stage with 3-point centering function. 360 rotatable, lockable in any position, 360 graduated in 1 increments (minimum retardation resolution 6', using vernier scale) 45 click stop function [Slide holder (U-SCB2) and mechanical stage (U-FMP) can be attached Achromat strain-free condenser (U-POC-2), 360 rotatable polarizer with swing-out achromatic top-lens, Click stop at position "0 " is adjustable. N.A. 0.9 (top-lens in) N.A. 0.18 (top-lens out) Aperture iris diaphragm: adjustable from 2mm to 21mm diameters OLYMPUS CORPORATION obtains ISO9001/ISO14001. Specifications are subject to change without any obligation on the part of the manufacturer. Printed in Japan M1544E-0807B