HS10 HYBRIDSCORE. Electronic scoring systems. Installation Start-up Maintenance SIUS AG



Similar documents
HS10 HYBRIDSCORE. Electronic scoring systems. Installation overview and components. ISSF approval phase 1

SIUS AG Im Langhag 1 CH-8307 Effretikon Switzerland Phone Fax admin@sius.com

SA941. Electronic scoring systems. System overview and components. The only system with ISSF approval for all disciplines SIUS AG

Let s tell you about our company

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Page 1. Description

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Bulb Replacement REPLACING BULBS WARNING

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Morini CM 162EI. Technical Data

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Auto Sentry-eXP Maintenance

SELF INSTALLATION GUIDE

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag DESCRIPTION pag TECHNICAL SPECIFICATIONS pag INSTALLATION pag.

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

T0118 T2118 T3118. Instruction Manual

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

Installation Instructions

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

FIRERAY 2000 Installation Guide

Original Assembly Guide

16/32 Channel 1U Rack Mount CCTV Power Supply

Portable Air Conditioner

Fading Red Tones on Color LaserJet 2600s

MS-800B Mobile Video Studio

24 Wide Screen LED Monitor with HDMI

ilan Ethernet Box for 9100 Installation Manual

SmartLogger1000. Quick Installation Guide. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Samuel Shorty Bunk Bed

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Mureva Assembly surface mounted wiring devices

Solid as a rock Soliroc

AMPSEAL* Automotive Plug Connector and Header Assembly

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2. Before starting, make sure firearm is UNLOADED!!

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

LED PAR 64 SHORT FLOOR 20X3W PWM RGB

E-PDD Duct Smoke Detector Installation Sheet

Rousseau 10. User Guide

OPERATING INSTRUCTIONS

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

OPL BASIC. Dosing System for Professional Laundry machines. Contents

DUOTOUR WITH SLIDING DOORS OPERATING MANUAL

Operating Instructions Drill rig DRU160

Terminal Boxes Series 8146

PD 100A. Printing data system

IH E Sigma Island 90

Features: Mounting the Optic

National- Spencer Inc.

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

ComPar KIT 1 & 2 DMX LED light set

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

3 IN 1 BATHROOM HEATER

Extra Tall Wide Span Gate

Quick start guide smart.power smart.power smart.power

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

INFRARED QUARTZ WALL HEATER

Product and functional description

Modular I/O System Analog and Digital Interface Modules

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

AN-65AG1 ENGLISH FRANÇAIS DEUTSCH ESPAÑOL

BUSINESS. Elektronisches Türschloss. Installation and User Manual. Ingeniously safe. Ingeniously simple.

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

TS93 EMR T/PT/TDE. Surface applied door closer

Doc. No: Issue: 1 Date: Aug BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

GeekDesk Max Instructions for Assembly & Use

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

2013 Wireless Video Intercom INSTALLATION GUIDE

Power Socket (2 Gang)

VACUUM CLEANER INSTRUCTION MANUAL

Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer

HandPunch. Overview. Biometric Recognition. Installation. Is it safe?

User manual. Videomatic VERDE MF

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

13 SERIES. Electronic step relays A

LIFT-505. BMF Lift Kit. Yamaha Drive Gas or Electric. Installation Instructions

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Drayton Digistat +2RF/+3RF

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

Installation and Operation Guide

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Transcription:

Electronic scoring systems HYBRIDSCORE Start-up Maintenance SIUS AG Im Langhag 1 CH-8307 Effretikon Switzerland Phone +41 52 354 60 60 Fax +41 52 354 60 66 www.sius.com admin@sius.com

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Table of contents Assembly of the target airguns 10m 2 3 Assembly of the target small bore rifle 50m 4 6 Connections and laying of cables 7 Mounting of target airguns 10m 8 9 Example of an installation airguns 10m 10 Example of an installation (overview) airguns 10m 11 Mounting of target small bore rifle 50m 12 Example of an installation small bore rifle 50m 13 Example of an installation (overview) small bore rifle 50m 14 Wiring installation (cables and power supply) 15 Start-up Bringing into service 16 17 Page Maintenance Maintenance and function test 18 19 Assembly of the target airguns 10m 1.1 Article no. V0 (with digital display) Complete target incl. reinforced front frame for airguns and integrated target illumination Manual Stand-alone with remote control: www.sius.com > Products > Sport > Targets > > «Manual Stand-alone and Start-up» 1.1 1.2 Article no. V1 (without digital display) Complete target incl. reinforced front frame for airguns and integrated target illumination 1.2 Article no. AN003 Target holder incl. bullet trap for airguns 2

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE 3.1 Assembly of target Push the locking plate to the side and mount the target on both sides into the target holder. Mounting of the target front mask (glossy side inside) Pull the target upwards and move it towards the target holder. Mounting of optional backing target for manual shot control (to be inserted into the provided slot in the bullet trap) Assemble the target and the target holder. 3

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Assembly of target small bore rifle 50m Assembly of the target Article no. V1 Complete target incl. reinforced front frame for airguns without digital display Push the locking plate to the side and mount the target on both sides into the target holder. of the rubber sheet Article no. AN001 Target holder incl. rubber sheet Article no. LS10A042 (the rubber sheet protects against sun and debris from the bullet trap) Pull the target upwards and move it towards the target holder. Assemble the target and the target holder. 4

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Article no. LS10AN008 Mounting plate 4x AMSZI06x10 4x AMU042 2x AMA178 Article no. AN007 Reinforced front frame for small bore rifle and Article no. A052, target front mask 50m for small bore rifle of the target holder on the mounting plate. Article no. A026 Rubber membrane in front (used for acoustic measurement) of target front mask on the reinforced front frame. of rubber membrane in front, inside the target (Position of blanked out hole = at the bottom of the target) of the reinforced front frame on the mounting plate. 5

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE 2x AMSLT04x06 1x LS10A058 4x AMSLT04x06 4x AMU011 Article no. LS10AN010 Weather protection box of the reinforced front frame on the mounting plate. Closure of weather protection box. of weather protection box on the mounting plate. of the target holder on the mounting plate. (Assembly of target and target holder according to page 4, point 3) 6

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Connections and laying of cables 1 2 3 4 5 1 Remote control for target with digital display 2 Power supply for target with digital display resp. stand-alone version with SIUSLANE software 3 Plug-in for target print 4 LTW-network-connection (Cabeling according to draft on page 15) 5 Target elevator or Cable relief at target holder/bullet trap and laying of cables from behind into the target. Laying of cables and cable relief. 7

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Mounting of the target airguns 10m on pedestal, Article no. SHS08 1. Assembly of the pedestal a) Mounting of feets 3. Attaching the bullet trap to the pedestal The guide rail of the holder enables the mounting of the bullet trap to the pedestal. a b b) Fixation of retainer rod Big opening Small opening With the upper screw (a) the height can be adjusted variably. The lower screw (b) enables the fixed setting of the 3 positions (standing 140cm > kneeling 80cm prone 50cm) trough the provided holes in the retainer rod. 2. Mounting the holder on the bullet trap Assemble the holder (needed for installation on the pedestal) and the bullet trap. Distance between target and wall is 21cm (= backside feet) 21cm 8

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Mounting of the target airguns 10m on automated target elevator ATE10 Mounting to the wall 3 positions target elevator for. Mobile or fixed installation possible.the target is attached to the electronic target elevator from the back. Detailed information: installation manual ATE10 for «B-INBE-ATE10V1/2-de» Mounting the target to the wall through the holes on the back of the target holder. 9

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Example of an installation airguns 10m Mounting to the wall Wood plate, thickness min. 25mm, hight 400mm (construction side) Space for cables Wood beam 100/100mm (construction side) Power socket for power supply (construction side) Power supply for 10 lines (SIUS) Line 1 Line 2 Line 9 Line 10 Line 11 Tube Ø 50mm (construction side) preferably with inserted taut wire 10

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Example of an installation (overview) airguns 10m Mounting to the wall Target with illumination (SIUS) Tube Ø 50mm in ground (construction side) preferably with inserted taut wire Connection box 300x300x200mm (construction side) Illumination: Do not use halogen lamps or electric bulbs. Infrared light could interfere with the system. For all outside installations we recommend CFL / gas discharge lamps. 11

42 * 115 * 42 * 115 * 35 * 209 35 * 209 4 269 4 269 557 557 392 50-100 392 50-100 42 * 115 * 35 * 209 4 269 557 B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Mounting of target small bore rifle 50m on automated target elevator ATE10 on a beam 6 5 4 3 191 D 470 sun Sun protection C 85 * 300 * 85 * B 45.5 470 30 * 410 * 30 * 185 * = Montage, Alle Löche SIUS Im Langhag 1 C Tel: +41 52 354 A 310 D 6 D 6 5 470 5 470 sun protection 4 sun protection 4 6 3 3 191 51.5 191 51.5 5 2 2 4 1 1 REV Änderungen Datum Name 3 D D At min least 450 for 450 for sun protection min 450 for sun protection C C C C 85 * 300 * 85 * B 45.5 B 470 85 * 30 * 300 * 85 410 * 30 * 185 6 B A 6 470 30 * 410 * 5 310 30 * 4 12 * = Montage, 45.5 Alle Löcher für Schrauben M8 REV Änderungen Datum Name 3 185 6 SIUS Im Langhag 1 CH - 8307 Effretikon Tel: +41 52 354 60 60 Fax: +41 52 354 60 66 Datum Name Gez. 23.01.2012 ew Gepr. Norm. * =, all holes for screws M8 mit A Prellschutz 50m 3 positions target elevator for. Mobile or fixed installation pos-sible. The target is attached to the electronic target elevator from = Montage, Alle Löcher für Schrauben M8 310 Maßstab 1:5. the back. REV Im Langhag Änderungen1 CH - Datum 8307 Effretikon Name Prellschutz 50m.idw 6 5 4 SIUS 3. Tel: +41 52 354 60 60 Fax: +41 52 354 60 66 2 1 By using the mounting plate Datumthe Name target can be fixed on the beam. Detailed information: installation manual ATE10 for Gez. 23.01.2012 ew mit Be aware, that the target Gepr. should not be exposed to direct «B-INBE-ATE10V1/2-de» Prellschutz 50m Norm. sunlight.. Maßstab 1:5 2... Blatt 1 A3 D:\Products\TARGETS\DetectionSystems\\Mechanik\\Kleinkaliber\ mit Blatt 1 A3 D:\Products\TARGETS\DetectionSystems\\Mechanik\\Kleinkaliber\ mit Prellschutz 50m.idw 1 B A A

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Example of an installation small bore rifle 50m on a beam Targe line Target (SIUS) Line 1 Line 2 Line 10 Line 11 Power supply for 10 lines (SIUS) Power socket for power supply (construction side) Tube Ø 80mm (construction side) preferably with inserted taut wire 13

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Example of an installation (overview) small bore rifle 50m on a beam Target (SIUS) Tube Ø 50mm in ground (construction side) preferably with inserted taut wire Connection box 300x300x200mm (construction side) Tube Ø 100mm to central computer room (construction side) preferably with inserted taut wire Illumination: Do not use halogen lamps or electric bulbs. Infrared light could interfere with the system. For all outside installations we recommend CFL / gas discharge lamps. 14

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Air rifle / air pistol installation 10m and small bore rifle installation 50m overview The installation is divided into 3 article groups: article group target line (A), article group for cables and power supply (B) and article group firing line (C). The article group for cables and power supply (B) is designed to support up to 10 lanes. In addition, power supply cables are required (connection cable: device to country specific plug) (Pos. 1). Each lane is equipped with its own control unit / monitor, which enables a individual control of the device by every single shooter. The installation can be extended to a complete competition outfit (central PC for data acquisition, display and evaluation, wide screen TV, beamer/projection screens). A 1 2 10 A1 B A2 A3 A2 B4 1 B1 B2 B3 B4 Central PC for data acquisition, display and evaluation > see brochure Large installations and components C4 C5 C C3 C1 1 C2 C6 C7 C8 C9 Pos. Article no. Pcs. Description A Article group target line A1 V1 1 Target 10m resp. 50m incl. LED Illumination, without integrated digital display A2 KL001-2.0 2 Cable LTW male fem 2.0m A3 KL001-T 1 T-Adapter fem/fem/male LTW IP67 B Article group cables and power supply B1 NT211V0 1 Power supply for 10 lines 225W with LTW 230V B2 KL013 1 Y power cable for NT211 B3 KL001-20.0 1 Cable LTW male fem 20.0m (for 10m installation) B3 KL001-65.0 1 Cable LTW male fem 65.0m (for 50m installation) B4 KL001-R 2 Terminating resistor, red, male LTW IP67 C Article group firing line C1 M941 1 Monitor TFT 10.4 (26cm) C2 CU941-CLUB 1 Control unit, for clubs, schools etc. (ISSF approval phase 1 and 2) C3 KL003-2.0 1 Cable LTW male RJ45 2.0m C4 KL001-T 1 T-Adapter fem/fem/male LTW IP67 C5 KL001-2.0 1 Cable LTW male fem 2.0m C6 RC941 1 Remote control RC941 (option) C7 D112-N 1 Thermal printer incl. power supply (option) C8 AAG133 1 Barcode scanner (option) C9 Monitor for spectators incl. connection cable (on request) C10 SNI210 1 USB-LON-Dongle incl. SIUSLANE software (option with PC/Laptop > see page 3) 1 Reference Country-specific power supply cable > page 20 15

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Bringing into service Check in advance All devices connected according ot the instructions? Any visible damages on devices or cables? Voltage of the power supplies set according to the voltage of the electric power supply? The lane no. is set by turning the arrow on the number plate to the corresponding figure, using a screwdriver. Numbering is made from bottom to top. Set the lane no. on the target To set the lane number, it is necessary to remove the print out of the target. This has to be done without a connected target holder. 1. Pull out the mechanical interlock button of the print (must be locked again when closing the target). D C B 2. Unclip by raising and pulling. A D = 1-no. setting The according 1-no. is set. C = 10-no. setting If more than 10 targets are connected, the according 10-no. can be chosen. Otherwise leave the setting on 0. 3. Pull out the whole print. B = 100-no. setting If more than 100 targets are connected, the according 100-no. can be chosen. Otherwise leave the setting on 0. A = Node-Nr. (no. of the target in the same line) Only applicable if in the same line several targets are in use (for example military use). Otherwise leave the setting on 0. Bringing into service 16

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Examples of setting the lane no. on the target Setting lane no. 8: Setting lane no. 163: Connecting the electricity network Connect all devices to the electricity network. Control of the operating lamp Connections and laying of cables 1 2 3 4 5 After proper installation and connecting the target to the electricity network the operating lamp WD blinks in a interval of 1/2 second. 1 Remote control for target with digital display 2 Power supply for target with digital display resp. stand-alone version with SIUSLANE software 3 Plug-in for target print 4 LTW-network-connection (Cabeling according to draft on page 15) 5 Target elevator Control of detection system transmitters oder The two transmitters of the measuring system need to glow. Closing the target After closing the target, check that there are no cables in the firing line. Configuration of control unit at firing point The control unit (for example SA941 or PC/Laptop with LON-dongle and SIUSLANE software) can be configured. See > http://sius.com > Downloads Laying of cables and cable relief. TIP With a PC and LON-Organizer software installed the functionability of all installed components in the network can be checked. Software LON-Organizer > http://sius.com > Downloads 17 Bringing into service

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Maintenance and function test Cleaning from dust and dirt remove all dust and dirt with a vacuum cleaner clean the detection system (transmitter and receiver) with a soft damp cloth (do not use any cleaning agent) Replacing a worn out target front mask The target front mask should be replaced: if its circular shape is not visible anymore if it is in such a bad condition that the optic of the target is affected if there are holes, which are bigger than the used projectile Replacement of rubber sheet Mounting of rubber sheet Rubber sheet LS10A042 inside the target holder (50m target) > If defective/torned replace immediately Large holes can permit sunlight to shine into the back of the target. Bad bullet traps can throw back debris. Both can generate errors in the detection system. Repair / Replacement of rubber membrane For the 10m target the front mask can be replaced from inside. Art. no. A026 Rubber membrane inside target (50m target) (used for the acoustic measurement) If the rubber membrane is frayed in the center, the defects parts should be cut out. Holes outside of the center (max. Ø 50mm), should not be bigger than the used projectile. Otherwise the rubber membrane must be replaced. For the 50m target the front mask can be replaced outside directly on the reinforced front frame. of rubber membrane inside target: position of punched hole = bottom of target. Maintenance and function control 18

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Function check 5.1 Is the operating lamp WD blinking? If not > check power supply and cables. 5.3 Control of optical detection system Hold the finger shortly in the detection system and check, if the two transmitters are blinking. If not > check for dirt and clean. 5.2 Communication control press service-pin button the red TX-lamp should blink at the same time the green RX-lamp should blink on neighbour target 5.4 Control of acoustical detection system Tapping each of the five sound transducers. The corresponding light (MIC1 5) should be blinking. Update of the software The software for the control unit can be updated with the "LON- Organizer" software installed on a PC. TIP After each manipulation of the target / system restart the equipment. 19 Maintenance and function control

B-INWA- -en 06/15 Electronic scoring systems HYBRIDSCORE Country specific power supply cables The connection between device and socket is achieved with the use of country specific power supply cables. This is provided with the device coupling on one side and with a country specific plug on the other side. 1 2 3 4 5 Pos. Artikel-Nr. Bezeichnung 1 AA101 Power supply cable with GB plug, 2m 2 AA102 Power supply cable with USA plug, 2m 3 AA109 Power supply cable with CH plug, 2m 4 AA110 Power supply cable with Euro plug, 2m 5 AA126 Power supply cable with AUS plug, 2m SIUS worldwide There are SIUS representatives all around the globe. Find your local SIUS sales partner here: www.sius.com/en/representatives 20