Directional Controls. Solenoid Operated Directional Valve DG4V-3S, EN 490 For Mobile Equipment



Similar documents
Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Directional Controls

3 Port Solenoid Valve

3/2 Solenoid Cartridge Valve, Size 6

Industrial Valves. Marketing Catalog. Reliable and continuous performance in the world's most demanding and rigorous applications.

KDG3V-5/7/8, 10 Series

PVH131/141 Variable Displacement Piston Pump - 11 Design

Assisted lift operated 2/2-way solenoid valves Type EV250B

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Solenoid Operated Directional Valves

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Pressure Relief. Pressure Relief Valves. Vickers

3 Port Solenoid Valve

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Solenoid Operated Directional Valves

2/2 and 3/2 Way Size 6 Seat Valves

Unit 24: Applications of Pneumatics and Hydraulics

3/2- and 2/2-way cartridge valve type BVE

SOLENOID VALVES AND PNEUMATIC VALVES

Denotes New Winner s Circle Product Line. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

SOLENOID VALVES 3-4 WAY

Pressure Relief Valves for Pipe Mounting

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Single sub-base valve

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Chapter 6: Check Valves

3/2-way Solenoid Valve, direct-acting, NC or NO

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Chapter 5: Flow Valves

For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } {175}

Directional Control Valves

DIRECTIONAL CONTROL VALVES

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Line-Mounted Valves L Series

Pressure relief valves Size 6

System 8. ü ( System 8

Electro-pneumatic control valves

Check Valves Valve locator

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Load-sensing control block in mono and sandwich plate design

Vickers. Overhaul Manual. Directional Controls. Directional Control Valves. DG3V-8/DG5V-8 Hydraulic/Solenoid Pilot Operated 5007.

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Proportional Pressure Reducing Valves

Variable Displacement Pump AA10VSO

Valves. Sub-Base Mounted Valves to ISO 5599/2

Laserlyte-Flex Alignment System

2.12. page Products for Explosion hazardous Environment

4/2-Way Pneumatic Solenoid Valve

RA / Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

Hydraulic Flow Control Valves

Control block EDD Modular Directional Valve

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

G1/4 Q8. Standard with biased position

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

3/2-way Mini Solenoid Valve

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Series PVP Variable Volume Piston Pumps

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Directional seated valves type VP 1

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Cable Plug acc. to DIN EN , Form A

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

D. PARAMETER SPECIFICATION Measured Variable: Displacement

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Line rupture protection valves type LB

Transcription:

Vickers Directional Controls Solenoid Operated Directional Valve DGV-3S, EN 90 For Mobile Equipment Flows to 0 l/min (10.5 USgpm), * Design P, A & B Pressures to 350 bar (5000 psi), T Pressures to 10 bar (3000 psi) Variety of manual override options are available: plain, water-resistant and latching. High performance features including minimal pressure drop, scratch-proof override seals, high reliability, multiple electrical connections and ease of servicing. Characteristics Maximum Operating Pressure A, B and P ports: 350 Bar (5000 psi) Maximum Tank Line Pressure 10 bar (3000 psi) General Description This solenoid operated directional control valve is for directing and stopping flow at any point in a hydraulic system. Its primary function is to determine the direction of fluid flow in a work cylinder or control the direction of rotation of a fluid motor. Port connections are made by mounting the valve on a subplate or manifold. The valve has wet armature type solenoids. It is derived from the standard model series DGV-3S-0. It is distinguished as a special by the EN90 designation. Electrical connections to the valve are typically made directly to the solenoid by various plug-in devices. Solenoids are available in DC voltages only. Features and Benefits Special design for high tank line rating. Tank line can withstand pressures up to 10 bar (3000 psi). Ideal replacement for DGV-3 for high tank line pressure applications. Meets key OEM specifications regarding temperature, vibration, heat rise/drop, impact test, water dunk (thermal shock and hermetic seal), salt spray and dielectric strength test. High thermal shock and impact resistance due to new coil design. Frame around coil ensures high strength and allows frame to expand/contract without added stress. Available with molded-in surge suppressor/diodes to protect PLCs or circuit boards from back electro-magnetic force (EMF). Mounting Interface ISO 01-AB-03--A CETOP 3 or NFPA D03 (formerly D01) ANSI B93.7 Weights (approximate) Single solenoid models:1, kg (3.5 lb) Double solenoid models:, kg (.8 lb) Reference GB-C-015 Solenoid Operated Directional Valves Revised 0/9 509/EN/059/A

Contents Model Code................................................................................................... 3 Performance Data.............................................................................................. Installation Dimensions.......................................................................................... Electrical Plugs & Connectors.................................................................................... 7 Mounting Bolts................................................................................................ 10 Mounting Interface............................................................................................. 11 Vickers, Incorporated 199 All Rights Reserved

Model Code 1 3 5 7 8 9 10 11 1 13 1 15 1 Directional Control Valve DGV - Subplate mounting; solenoid operated. Pressure rating 350 bar (5000 psi) for ports P, A & B. Pilot Valve 3S - Standard performance; up to 0 l/min (10.5 USgpm) at 350 bar (5000 psi) 3 Spool Type 0 - Open center (all ports) - Closed center (all ports) - Closed center (P blocked) A & B to T 7 - Open center (P to A & B) T blocked 8 - Tandem center (P to T) open crossover - Closed center (two way) 33 - Closed center, bleed A & B to T 3 - Closed center, bleed A & B to T 5 - Closed center (all ports) regen. towards workport A 5 - A&B to T, P blocked, regen. by solenoid A - Closed center (P blocked) A & B to T 51 - Closed center (all ports) regen. towards workport B 51 - A&B to T, P blocked, regen. by solenoid B Spool/Spring Arrangement A - Spring offset, end-to-end AL - Same as A but left hand build B - Spring offset, end to center BL - Same as B but left hand build C - Spring centered F - Spring offset, shift to center FL - Same as F but left hand build 5 Manual Override Options No symbol - Plain override(s) in solenoid end(s) only H - Water-resistant override(s) on solenoid end(s) H - Water resistant overrides on both ends P - Standard overrides on both ends Y - Latching manual override(s) on solenoid end(s) (includes H feature seal) No override in non-solenoid end of single solenoid valves. Solenoid Energization Identity V - Solenoid A is at port A end/or solenoid B is at port B end, independent of spool type. Omit for U.S. ANSI B93.9 standard requiring solenoid A energization to connect P to A and/or solenoid B to connect P to B, independent of solenoid location. 7 Flag Symbol M - Electrical options and features 8 Coil Type U - ISO 00 (DIN 350) mounting U1 - ISO 00 (DIN 350) mounting, with connector U - ISO 00 (DIN 350) mounting, with connector and lights KU - Top exit flying leads SP1- Single.3mm (0.5 in) spade connector to IEC 70 (NFPA, SAE J858a, Type 1A) (Internal ground) SP- Dual.3mm (0.5 in) spade connector to IEC 70 (NFPA, SAE J858a, Type 1A) Female connector to be supplied by customer. 9 Top Exit Connectors (KU type only) Omit for no connector. P1 - Packard Weatherpak Connector (female) P - Deutsch Connector (male) P7 - Packard Weatherpak Pins (male) P1- Packard Weatherpak Connector (male) 10 Surge Suppressor/Damper Omit for not fitted. D - Encapsulated diode ve to right; +ve to left when facing retaining nut 11 Coil Rating G - 1 VDC H - VDC 1 Port T Rating 7-10 bar (3000 psi) 13 Design Number Subject to change, installation dimensions remain as shown for design numbers 0 through 9. 1 Special Version Standard performance version with 10 bar (3000 psi) tank rating. Solenoid with external frame for improved thermal stability, improved hermetic seal. 15 Port Restrictor Plugs Omit if no restrictor plugs are fitted. For details of plug orifice sizes and how to specify in model code, see page 8. 3

Performance Data Feature Pressure limits: P, A and B ports T port Flow rating 350 bar (5000 psi) 10 bar (3000 psi) See performance data Relative duty factor Continuous; ED = 100% Type of protection: ISO 00 coils with plug fitted correctly SP1 Single spade,3 mm SP Dual spade,3 mm Coil winding Lead wires (coils type KU) Coil encapsulation Permissable voltage fluctuation: Maximum Minimum Typical response times at 100% rated volts measured from application/removal of voltage to full spool displacement of C spool at: Flow rate P-A, B-T Pressure DC (=) energizing DC (=) deenergizing IEC 1 class IP7 (depending on connector) IEC 70 IEC 70 Class H Class H Class F Refer to temperature limits. 90% rated 0 l/min (5.3 USgpm) 175 bar (537 psi) 0 ms 0 ms Power Consumption DC solenoids at rated voltage and 0 C (8 F). Full power coils: 1V, model type G V, model type H 30W 30W Maximum flow rates Performance based on full power solenoid coils warm and operating at 90% rated voltage. Typical with mineral oil at 3 cst (18. SUS) and a specific gravity of 0.87. Spool/Spring Curve Code 0A(L) 3 0B(L) & 0C, 0F 1 A(L) 3 B(L) & C, F 3 B(L) & C, F 5 7B(L) & 7C, 7F 8B(L) & 8C 8 A(L) 7 B(L) & C 33B(L) & 33C 3B(L) & 3C 5 5BL, 5C, 5 5BL & 5C 5 B(L) & C 5 51B & 51B 5 Consult Vickers regarding each application that will jointly have flow rates approaching this curve and a pressurized volume exceeding 000 cm 3 (1 cu.in.). Pressure psi bar 5000 350 1 300 000 50 3 3000 00 000 150 100 8 5 1000 7 50 0 0 0 10 0 30 0 l/min 0 8 10 USgpm Flow rate

Pressure drops Pressure drop psi bar 1 11 1 10 10 10 10 9 10 8 8 100 7 80 5 0 3 0 1 0 0 0 10 0 30 0 l/min Pressure drop psi 000 100 100 800 00 0 bar 10 10 100 80 0 0 0 15 1 13 0 10 0 30 l/min 0 3 9 Flow rate USgpm 0 8 USgpm Flow rate Pressure drops in offset positions except where otherwise indicated Spool/spring code Spool positions covered P to A P to B A to T B to T P to T B to A or A to B 0A(L) Both 5 5 0B(L) & 0C, 0F A(L) Both 5 5 B(L) & C, F 5 5 B(L) & C, F 7B(L) & 7C, 7F 8B(L) & 8C All 9 9 5 5 3 A(L), B(L) & C All 33B(L) & 33C 3B(L) & 3C 5 5 5 5 3 1 3 15 3 1 3 15 1 7 5BL & 5C 10 5BL Both 11 10 10 5C B(L) & C 1 11 10 10 10 51B All 10 51B B plugged A plugged P plugged 1 10 1 11 13 10 10 For other viscosities, pressure drops approximate to: Viscosity cst (SUS) 1 0 3 5 5 7 85 (17.5) (97.8) (00) (51) (30) (35) (399) % of p 81 88 10 111 11 10 1 A change to another specific gravity will yield an approximately proportional change in pressure drop. The specific gravity of a fluid may be obtained from its producer. Fire resistant fluids usually have higher specific gravities than oil. 5

Installation Dimensions mm (inch) 5, (0.) Thru 10,0 (0.39) C bore to depth shown holes for mounting Identification plate showing circuit information and solenoid A & B identification 17,0 (0.7) 3rd angle projection, (1.7),0 (1.81) 19, (8.) U1 Model option shown 7,0 (.91) 3,8 (.51) 79,7 (3.1) 51,7 (.03) 1,7 (0.8),5 (0.9) Mounting surface seals furnished 3,0 (0.1) 3,0 (0.1) 155,7 (.13) 51, (.0) U DIN 350 Pressure port P 7,9 (0.31) ( System ports) 0,7 (0.03) Cylinder port A 0,5 (1.59) 7,5 (0.30) 1,7 (0.) 5,8 (0.3) 1, (0.) 31,0 (1.), (1.05) 3,5 (1.8) Manual actuator Both ends 5,3 (0.1) 19,0 (0.75) Cylinder port B 10,3 (0.1) Tank port T 7,8 (1.09)

Electrical Plugs & Connectors Solenoid Connections mm (inch) 9, (0.37) 3rd angle projection 9, (0.37) 18,8 (0.7) 1,9 (0.7) 18 AWG, cross-linked polyethelene insulation, UL style 3173 1 strands copper-tinned 3, (1.3) 39,9 (1.57) 7, (1.07) SP1 Single 1/ SAE Spade (Internal ground) Typical Connector Assembly & Connectors SP Dual 1/ SAE Spade KU Top Exit Flying Lead P1 Packard Connector (Female) P7 Packard Connector Pins (Male) P Deutsch Connector (Male) P1 Packard Connector (Male) DIN 350 Connector Cable diameter range... Ø10 mm (0.0.0) Wire section range..... Ø,51,5 mm (0.00080.003 in ) Terminals.............. Screw type Type of protection...... IEC1 class IP5, when plugs are fitted correctly to the valves with interface seals (supplied with plugs) in place. Connector can be positioned at 90 intervals on valve by re-assembling contact holder into appropriate position inside connector housing. Connectors with and without indicator lights are available (order separately): Receptacle U1 Coils without lights U Coils with lights Voltage Part Numbers Gray Black A sol. B sol. 71077 710775 1-9777 977 Seal 51 (.01) 18 sq. (0.71) 1,5 (0.0) 7 (1.0) M3 thread 30,5 sq. 5,5 (1.0) (0.) 7,5 (1.08),5 (1.0),5 (0.88) 7

Electrical Plugs & Connectors (continued) Manual Overrides Water-resistant manual override on solenoid DGV-3S-****(L)-H-(V)M-**-**-0-EN90 Application General use where finger operation is required (standard manual overrides cannot be operated without using small tool). Latching manual override on solenoid DGV-3S-****(L)-Y-(V)M-**-**-0-EN90 Application Stainless steel lever/latch mechanism and water-resistant seal make this feature ideal for vehicle-mounted and exposed applications requiring emergency selection of valve for a period of time in the event of electrical failure. Manual actuation must be applied within this diameter: approximately 0 (0.75). Spacer prevents actuation by larger device. 15 (0.) Overall length of valve with standard manual overrides Lever in latched position Lever in free position Push lever to operate valve; latch holds lever in operated position 5 (.5) 0 (1.) Overall length of valve with standard manual overrides Lift latch to release lever Spacer Notes: 1. Opposite solenoid (on C and N double solenoid models) should not be energized while the valve is latched in selected position.. Y feature is field-convertible from H type manual override (omitting spacer), but is not field-convertible from other models. Port Restrictor Plugs Restrictor plugs are available for use in ports P, T, A or B. These can be used for restricting flow or for circuit dampening. Restrictor plugs are not recommended for use above 10 bar (3000 psi) system pressure. Typical model codes: DGV-3S-**-M-**-**-0-P08 (0.8 mm dia orifice in port P) DGV-3S-**-M-**-**-0-P10-A10 (1.0 mm dia orifice in ports P and A) Restrictor plug selection table Code Orifice Part diameter number *00 Blank 9353 *03 0,30 (0.01) 931 *0 0,0 (0.0) 93 *08 0,80 (0.030) 933 *10 1,00 (0.00) 93 *13 1,30 (0.050) 935 *15 1,50 (0.00) 93 *0,00 (0.080) 937 *3,30 (0.090) 938 * = P, T, A or B, as required Available in multiples of 5 per part number M5 x 0.8-H thread for plug extraction Maximum port dia in subplate/manifold block: For steel and SG (ductile) iron: 7,0 (0.3) For gray iron:,5 (0.5) 8

Surge Suppression Devices (For DC Valves) Standard diode (D) Diode in parallel with coil. When switch (S 1 ) is opened, the energy stored in the coil is trapped and dissipated by the diode (D ). Works only with DC voltage Polarity dependent Increases drop out time D S 1 NOTE: These surge suppression devices are Polarity Dependent. Proper biasing conditions must be met when installing/connecting a coil in a system. Valve Shift and Dropout Times With and Without Surge Suppression Shift Dropout CETOP 3 No Diode 3 0 Diode 3 11 Times represent cessation/application of voltage to coil versus velocity (start/stop) of a cylinder using a single solenoid, spring offset valve (time in milliseconds). Spare parts data Refer to service drawing I388S for spare parts and kit information. Solenoid Coils DC Coils Code Voltage U Type SP1 Type SP Type KU Type Seal kits Kit No. 858995 Note: Each seal kit covers a variety of models and may have redundant seals for a particular model. Full Power Coils: G 1V H V Full Power Coils: G 1V H V 0-3095 0-30955 KUP1 Type TBD TBD 0-3090 0-3091 KUP Type 0-3098 0-3099 0-3095 0-30957 KUP7 Type 0-3109 TBD 0-3095 0-30953 KUP1 Type 0-309 0-3097 9

Mounting Bolts Inch bolt kits, #10 UNCB Size x length, in (mm) #10- x 1,7 (0.50) BK590715 #10- x 19,05 (0.75) BK87 #10- x 5, (1.00) BK30 #10- x 31,8 (1.5) BK59071 #10- x 38,1 (1.50) BK30 #10- x, (1.75) BK0-159 #10- x 50,8 (.00) BKDG398 #10- x 57, (.5) BK0-13915 #10- x 0,3 (.38) BK89 #10- x 9,9 (.75) BK870017 #10- x 9,9 (.75) BKDGFNL9M #10- x 7, (3.00) BK0-159 #10- x 79, (3.13) BK850 #10- x 88,9 (3.50) BK851 #10- x 95,3 (3.75) BK8970 #10- x 100 (3.9) BK85 #10- x 101, (.00) BK0-1597 #10- x 109,5 (.31) BK853 #10- x 10,7 (.75) BK85 #10- x 17,0 (5.00) BK0-1599 #10- x 130, (5.13) BK855 #10- x 133, (5.5) BK0-1598 #10- x 139,7 (5.50) BK85 #10- x 150,9 (5.9) BK857 #10- x 10,3 (.31) BK858 #10- x 170,0 (.9) BK859 #10- x 177,8 (7.00) BK89035 Metric bolt kits, M5 Size x length, mm (in) M5 x 0 (0.79) M5 x 5 (0.98) M5 x 30 (1.18) M5 x 0 (1.57) M5 x 50 (1.97) M5 x 55 (.17) M5 x 0 (.3) M5 x 70 (.7) M5 x 75 (.95) M5 x 80 (3.15) M5 x 90 (3.5) M5 x 95 (3.7) M5 x 100 (3.9) M5 x 110 (.33) M5 x 10 (.7) M5 x 130 (5.1) M5 x 10 (5.51) M5 x 150 (5.91) M5 x 10 (.30) M5 x 170 (.9) M5 x 00 (7.87) BK83M BK573M BK15M BK01593M BKDG399M BK98135M BK83M BK15M BK8970M BK837M BK838M BK8971M BK839M BK80M BK81M BK8M BK83M BK8M BK85M BK8M BK8M Metric bolt kits, M Size x length, mm (in) M x 1 (0.3) M x 0 (0.79) M x 5 (0.98) M x 30 (1.18) M x 0 (1.57) M x 5 (1.77) M x 50 (1.97) M x 55 (.17) M x 5 (.5) M x 70 (.7) M x 75 (.95) M x 80 (3.15) M x 80 (3.15) M x 85 (3.35) M x 90 (3.5) M x 100 (3.9) M x 110 (.33) M x 115 (.53) M x 10 (.7) M x 10 (5.51) BK535M BK5355M BK535M BK5357M BKDG0133M BK5359M BK53570M BK53571M BK5357M BK53573M BK5357M BK38873M BKDGFN0137M BK97878M BK5357M BK97879M BK97880M BK53580M BK53581M BK38878M Note: If not using Vickers bolt kits, bolts must be to Grade 1.9 (ISO 898) or better. The required bolt length should allow 0.0 (10 mm) thread engagement in the subplate/manifold block. Bolts should be torqued to 57 N.m ( lbf. in.) with threads lubricated. Prior to installation of DGV-3S valve, ensure that both the face of the valve and the face on which it is being mounted (i.e subplate, manifold, SystemStak valve or plate) is as clean as possible. Do not over tighten hold-down bolts beyond recommended values. 10

Mounting Interface The minimum thread depth is 1.5 times bolt diameter. The recommended full thread depth is x D+mm to aid interchangeability of valves and to reduce the number of mounting bolt lengths. The recommended engagement of the mounting bolt thread for ferrous mounting is 1.5 x D. Mounting surface must be flat within 0.013mm (.0005) and smooth within 1.1 micrometer (5 microinch). Mounting bolts when provided by customer should be grade 1.9 (SAE grade 7) or better. Dimensions shown in millimeters (inches). **The dimensions specifying the area within the dotted lines are the minimum dimensions for the mounting surface. The corners of the rectangle may be radiused as shown. Fluid Cleanliness Essential information on the correct methods for treating hydraulic fluid is included in Vickers publication 51 Vickers Guide to Systemic Contamination Control available from your local Vickers distributor or by contacting Vickers, Incorporated. Recommendations on filtration and the selection of products to control fluid condition are included in 51. Recommended cleanliness levels, using petroleum oil under common conditions, are based on the highest fluid pressure levels in the system. Fluids other than petroleum, severe service cycles, or temperature extremes are cause for adjustment of these cleanliness codes. See Vickers publication 51 for exact details. Filtration Requirements 19/17/1 11

A TRINOVA Company Vickers Systems, Division TRINOVA Ltd P.O. Box New Lane Havant PO9 NB UK Vickers Systems Zweigniederfasung der TRINOVA GmbH Am Josef 1 D-173 Wehrheim Germany Vickers Systems, Division TRINOVA Ltd /F Chiaphua Centre Yuen Shun Circuit Siu Lek yuen, Shatin N.T. Hong Kong Vickers, Incorporated 55 Corporate Drive P.O. Box 30 Troy, Michigan 8007030 USA Rev. 0/9 Printed in U.S.A.