Intel Active Management Technology with System Defense Feature Quick Start Guide



Similar documents
Intel Management Engine BIOS Extension (Intel MEBX) User s Guide

System Area Manager. Remote Management

Trusted Platform Module (TPM) Quick Reference Guide

Easy Setup Guide for the Sony Network Camera

Configuring and Using AMT on TS140 and TS440

Out-of-Band Management Reference

SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA USA. November v1.0

Intel Unite Solution. Standalone User Guide

Foglight Experience Monitor and Foglight Experience Viewer

Intel vpro Provisioning

The MEBx configuration program can be used to view and change the Intel Management Engine settings for the computer.

Trusted Platform Module (TPM) Quick Reference Guide

Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux

Intel Entry Storage System SS4000-E

Installing and Configuring vcloud Connector

Networking Guide Redwood Manager 3.0 August 2013

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

Windows Server 2008 R2 Initial Configuration Tasks

User Guide for Windows 10

Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1,

Steps for Basic Configuration

User Manual. User Manual for Version

Plesk 11 Manual. Fasthosts Customer Support

Classroom Management, part of Intel Education User Manual

Network Monitoring User Guide Pulse Appliance

Option Network Management Software for UPS UNMS II

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

Chapter 2 Preparing Your Network

Manual Wireless Extender Setup Instructions. Before you start, there are two things you will need. 1. Laptop computer 2. Router s security key

VeriSign PKI Client Government Edition v 1.5. VeriSign PKI Client Government. VeriSign PKI Client VeriSign, Inc. Government.

Dell Statistica Document Management System (SDMS) Installation Instructions

Changing Your Cameleon Server IP

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

PREFACE iss.01 -

Ethernet Connection Setup for CCU

MULTIFUNCTIONAL DIGITAL SYSTEMS. TopAccess Guide

User Guide Software Version 2.1.0

Release Notes. Pre-Installation Recommendations... 1 Platform Compatibility... 1 Known Issues... 2 Resolved Issues... 2 Troubleshooting...

ASUS WL-5XX Series Wireless Router Internet Configuration. User s Guide

Hyper-V Server 2008 Setup and Configuration Tool Guide

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer

Creating a Gateway to Client VPN between Sidewinder G2 and a Mac OS X Client

Virtual Appliance for VMware Server. Getting Started Guide. Revision Warning and Disclaimer

Patching the Windows 2000 Server Operating System on S8100 Media Servers, IP600 Communications Servers, & DEFNITY ONE Communications Systems

How To Set Up Dataprotect

intertrax Suite resource MGR Web

Abstract. Avaya Solution & Interoperability Test Lab

IDDERO TOUCH PANELS. Video door phone configuration

Upgrading from Call Center Reporting to Reporting for Contact Center. BCM Contact Center

Backup & Disaster Recovery Appliance User Guide

QUANTIFY INSTALLATION GUIDE

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Initial Access and Basic IPv4 Internet Configuration

Connecting the DG-102S VoIP Gateway to your network

Deploying Windows Streaming Media Servers NLB Cluster and metasan

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

Ethernet Radio Configuration Guide

Virtual Appliance Setup Guide

Intel Matrix Storage Console

Remote PC Guide for Standalone PC Implementation

Installation Guide for Windows May 2016

JMC Next Generation Web-based Server Install and Setup

Check Your Package Contents. CD-ROM containing Manual and Warranty

Using Cisco UC320W with Windows Small Business Server

How to configure DVR and computer for running Remote Viewer via IP network

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

Chapter 3 Management. Remote Management

Allworx Installation Course

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.

uh6 efolder BDR Guide for Veeam Page 1 of 36

Lepide Active Directory Self Service. Installation Guide. Lepide Active Directory Self Service Tool. Lepide Software Private Limited Page 1

Forcepoint Sidewinder, Virtual Appliance Evaluation for Desktop. Installation Guide 8.x. Revision A

Qvis Security Technical Support Field Manual LX Series

Configuration Manual English version

Wireless G Broadband quick install

N300 WiFi Range Extender WN2000RPT User Manual

Intel vpro. Technology-based PCs SETUP & CONFIGURATION GUIDE FOR

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

Configuring the Avaya B179 SIP Conference Phone with Avaya Aura Communication Manager and Avaya Aura Session Manager Issue 1.0

Intel Server Raid Controller. RAID Configuration Utility (RCU)

LifeSize Transit Virtual Appliance Installation Guide June 2011

Configuring a Check Point FireWall-1 to SOHO IPSec Tunnel

Lab - Configure a Windows 7 Firewall

IDDERO TOUCH PANELS. Video door phone configuration

Windows 2000/XP Network

Preparing the Computers for TCP/IP Networking

How To Set Up A Thermal Cycler With Veritilink Remote Management Software

Dell OpenManage Mobile Version 1.4 User s Guide (Android)

Installing the Microsoft Network Driver Interface

LANDesk Management Suite 8.7 Extended Device Discovery

Intel NetStructure Host Media Processing Release 2.0 for Windows

Chapter 10 Troubleshooting

Classroom Management, part of Intel Education User s Guide. Available in the U.S. only for the K-12 market starting fall 2014.

Transcription:

Intel Active Management Technology with System Defense Feature Quick Start Guide Introduction...3 Basic Functions... 3 System Requirements... 3 Configuring the Client System...4 Intel Management Engine Configuration... 4 Intel AMT Configuration and Provisioning... 7 Changing the Intel Management Engine Password... 8 Resetting the Intel Management Engine Password / Unprovisioning an Intel AMT System... 9 Using the Intel AMT Web Browser Interface...10 Logging In From a Remote Console...10 Using the Intel AMT Web Pages...11 System Status Page...12 Hardware Pages...13 Event Log Page...14 Remote Control Page...15 Network Settings Page...16 User Accounts Page...17 Troubleshooting...19 D74915-001

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications. Intel may make changes to specifications and product descriptions at any time, without notice. The following are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries: Intel Intel logo Pentium Celeron Intel Management Engine Intel ME Intel Active Management Technology with System Defense Feature Intel AMT Intel PRO Network Connections *Other names and brands may be claimed as the property of others. Copyright 2006 Intel Corporation 2 Intel Active Management with System Defense Feature Quick Reference Guide

Introduction Intel Active Management Technology with System Defense Feature (Intel AMT) is a hardware-based solution that uses out-of-band communication for system management access to client systems. Even with a crashed hard drive, a locked operating system, or if a system is turned off, access is still available to the client system to perform basic management tasks. This guide contains basic system configuration instructions and information on using a web browser to access a client system. Advanced features of Intel AMT are available from software vendors that support these new management technologies. Advanced features are outside the scope of this guide. Please see http://www.intel.com/technology/manage/iamt/ for more information and a list of software vendors that support Intel Active Management Technology with System Defense Feature. Basic Functions A web browser can be used to perform basic management tasks. The web server on each Intel AMT system enables administrators to: View the system status. View the hardware installed in the system. View, start/stop, and clean the Intel AMT event log. Remotely reset, or power the computer on or off (when enabled in the client system BIOS). View and manage Intel AMT network parameters. View and manage Intel AMT user accounts. View and configure VLAN settings. System Requirements Client System The client system must be a computer with Intel PRO Network Connections that includes Intel Active Management Technology with System Defense Feature. The operating system loaded on the client system does not matter. Intel Active Management with System Defense Feature Quick Reference Guide 3

Console System The console system (i.e., the system used to access the Intel AMT client system) must have one of the following web browsers installed: Microsoft* Internet Explorer 6 SP1 or newer Netscape* Navigator 7.1 or newer Mozilla* Firefox* 1.0 or newer Mozilla Mozilla* 1.7 or newer Configuring the Client System Before configuring the client system, have the following information available to configure the Intel Management Engine and Intel AMT properly: A computer name: In Microsoft Windows*, right-click My Computer, click Properties, and click the Computer Name tab. Terminal Communication Protocol / Internet Protocol (TCP/IP) settings: In Windows, open the Control Panel, open Network Connections, and right click the connection and click Properties. Click TCP/IP and click Properties. Intel Management Engine Configuration The Intel Management Engine BIOS password must be entered and changed before configuring Intel AMT setup options. As a security precaution, the client system will not be accessible over the network until the default Intel Management Engine password is changed and Intel AMT is provisioned. 1. Power on the computer and enter system BIOS by pressing the F2 key. 2. Using the arrow keys, select the Intel Management Engine item from the top menu bar and press the Enter key. 3. Type in the default password: admin. (Note: This password is case sensitive.) 4 Intel Active Management with System Defense Feature Quick Reference Guide

Figure 1. Intel Management Engine Configuration Menu in the BIOS 4. The Intel Management Engine password must be changed prior to gaining access to Intel AMT setup options. Change the Intel Management Engine password. NOTE Intel Management Engine passwords must be between 8 and 32 characters long, have at least one upper case character, one lower case character, one number, and a special character (for example:!, @, #, $, %, ^, &, *). The system owner should document the new Intel Management Engine password, store it in a secured location (a vault, safe deposit box, or off-site storage), and have it available for future use. This document should be updated after any password change is made. Intel Active Management with System Defense Feature Quick Reference Guide 5

Figure 2. Intel Management Engine Menu in the BIOS 5. Select the Intel Management Engine Configuration item. 6. To enable Intel AMT, confirm that the Manageability Feature is set to Intel AMT. Other manageability options include enabling ASF and disabling manageability altogether. Intel AMT will be disabled if either of these options are selected. 7. To enable Intel AMT out-of -band communication in all sleep states, change the value of Turn On Intel Management Engine in Sleep States item to Always. 8. Press the ESC key to return to the Intel Management Engine main menu. 9. Select Save and Commit Settings. 10. Select Yes, submit new settings. 11. Press the F10 key and select Y to save and reboot. 6 Intel Active Management with System Defense Feature Quick Reference Guide

Intel AMT Configuration and Provisioning After completing configuration of the Intel Management Engine, the Intel AMT settings can be set. 1. Power on the computer and enter the system BIOS by pressing the F2 key. 2. Using the arrow keys, select the Intel Management Engine item from the top menu bar and press the Enter key. 3. Type in the Intel Management Engine password. (Note: This password is case sensitive.) 4. Select Intel Active Management Technology Configuration and press the Enter key. 5. Change the Computer Name and press the Enter key. NOTE Computer name must be between 1 and 32 characters long, may contain upper case characters, lower case characters numbers, however spaces, dashes, and any other special characters (for example:!, @, #, $, %, ^, &, *) are not allowed. 6. Select TCP/IP Configuration and press the Enter key. 7. By default, DHCP is enabled. If DHCP is disabled, enter the following TCP/IP settings for Intel AMT: Static TCP/IP address. Both the TCP/IP address and Host Name must be different than those configured for the operating system. Subnet mask. Default Gateway address (optional). Preferred Domain Naming Services (DNS) server address (optional). Alternate DNS server address (optional). Domain name (optional). 8. When done, press the ESC key to exit to the Intel Active Management Technology menu. 9. Select Provisioning Configuration. Intel Active Management with System Defense Feature Quick Reference Guide 7

10. Select Provisioning Mode from the menu and choose Small- Medium Business. By default, Enterprise provisioning is selected. The Small Business setting indicates that Intel AMT will be locally configured for this system. The Enterprise setting indicates that Intel AMT will be configured by an external provisioning server within the local enterprise. Enter the following information: Provisioning Server Address Provisioning Server Port TLS Pre-Shared Key PID TLS Pre-Shared Key PPS 11. Depending on the third-party management software that is chosen to be used with this system (if any), set the Compatibility Mode appropriate to the management software. 12 When done, press the ESC key to exit to the Intel Active Management Technology menu. 13. The optional SOL/IDER authentication method and the Intel AMT Protected Real Time Clock (PRTC) may be set through respective menu items. 14. When done, press the ESC key to exit to the Intel Management Engine main menu. 15. Select Save and Commit Settings. 16. Select Yes, submit new settings. 17. Press the F10 key and select Y to save and reboot. Changing the Intel Management Engine Password 1. Power on the computer and enter system BIOS by pressing the F2 key. 2. Using the arrow keys, select the Intel Management Engine item from the top menu bar and press the Enter key. 3. Type in the old Intel Management Engine password. (Note: This password is case sensitive.) 4. Select Change Intel Management Engine Password 5. Type in and confirm the new Intel Management Engine password. 8 Intel Active Management with System Defense Feature Quick Reference Guide

NOTE Intel Management Engine passwords must be between 8 and 32 characters long, have at least one upper case character, one lower case character, one number, and a special character (for example:!, @, #, $, %, ^, &, *). The system owner should document the new Intel Management Engine password, store it in a secured location (a vault, safe deposit box, or off-site storage), and have it available for future use. This document should be updated after any password change is made. 6. Select Save and Commit Settings. 7. Select Yes, submit new settings. 8. Press the F10 key and select Y to save and reboot. Resetting the Intel Management Engine Password / Unprovisioning an Intel AMT System Resets all Intel Management Engine / Intel AMT settings and passwords to the factory defaults. 1. While the system is powered off, move the Configuration Jumper on the desktop board to pins 2-3. 2. Power on the system and allow it to enter BIOS maintenance mode. 3. Select Reset Intel AMT to default factory settings. 4. Press the F10 key and select Y to save and reboot. 5. Power off the system. 6. Restore the Configuration Jumper to pins 1-2 for normal operation. Intel Active Management with System Defense Feature Quick Reference Guide 9

Using the Intel AMT Web Browser Interface Logging In From a Remote Console 1. On the remote console, open a web browser and enter the client computer name or IP address, and the port number. Use the following, if the network can resolve the client system host name to a TCP/IP address: http://host_name:16992 Example: http://testsystem:16992 Use the following if a static TCP/IP address is defined for the Intel AMT client system: http://ip_address:16992 Example: http://192.168.1.7:16992 Figure 3. Login Dialog 2. To Log in as an Intel AMT administrator, use admin for the User Name and use the password that was set in the Intel Management Engine when Intel AMT was first configured. 10 Intel Active Management with System Defense Feature Quick Reference Guide

NOTE Both the user name and password are case sensitive. Make sure to note any capitalization changes in either field when defining or changing them. The web browser shows the current status of the computer. The computer host name is shown in the top banner. Using the Intel AMT Web Pages Click the links on the left to access the Intel AMT information pages. The padlock icon indicates areas where the current Intel AMT user does not have sufficient rights to view. If an attempt is made to access an area where the Intel AMT user doesn t have sufficient rights, the browser will display a login dialog box. If another Intel AMT user account that has sufficient rights is used to login, the browser will then display the page. To update the display of the padlock icons, click the browser's refresh button. Intel Active Management with System Defense Feature Quick Reference Guide 11

System Status Page This page displays the power state, IP address, and other basic system information. Figure 4. Intel AMT System Status Screen 12 Intel Active Management with System Defense Feature Quick Reference Guide

Hardware Pages These pages display information about the hardware installed in the computer. Intel AMT gets this information from the client system s BIOS. Hardware changes will not be shown until after the client system is rebooted. Figure 5. Intel AMT System Information Screen Intel Active Management with System Defense Feature Quick Reference Guide 13

Event Log Page This page displays the Intel AMT Event Log. The options at the bottom of the page can be used to stop and start the Event Log and clear all events from the log. Figure 6. Intel AMT Event Log Screen 14 Intel Active Management with System Defense Feature Quick Reference Guide

Remote Control Page The Remote control page can be used to power cycle the client system, reset it, and power the system on or off. Boot options for the Intel AMT client system can also be specified. NOTE The options available on this page depend on the abilities of the client system. CAUTION These commands may cause data loss. They go directly to the system hardware and do not cause the operating system to shutdown gracefully. Figure 7. Intel AMT Remote Control Screen Intel Active Management with System Defense Feature Quick Reference Guide 15

Network Settings Page The Network Settings page can be used to change the Intel AMT network settings made on the client system. Figure 8. Intel AMT Network Settings Screen Host Name: The Host Name is a name that can used to browse to this computer. In DHCP mode, use the same name as the one set in the operating system. In static IP mode, use a name different from the one set in the operating system. After changing the host name, click the Refresh button in the web browser to update the name in the banner at the top of the page. Obtain IP address automatically: Intel AMT can automatically obtain an IP address from a DHCP server. If the DHCP option is selected, make sure the operating system is also set up for DHCP, and it is recommended that the network have a Domain Naming Services (DNS) server that can resolve the name. Use these settings: Intel AMT will use the specified TCP/IP settings. 16 Intel Active Management with System Defense Feature Quick Reference Guide

Preferred and Alternate DNS addresses: Specify the address of the DNS server that will resolve the computer host name. Respond to ping: Configures Intel AMT to respond to an IP ping. In static IP mode, Intel AMT always responds to a ping. In DHCP mode, Intel AMT will only respond to a ping when the operating system is down. Use tagged VLAN: This option is used to confine network traffic to a VLAN. The VLAN ID range is 1-4094. VLAN ID 1 is often reserved. Check the network switch documentation for details. User Accounts Page Select User Accounts to change admin name and password used to access the Intel AMT configuration screen and web interface on the client system. CAUTION User account passwords associated with the Intel Active Management Technology are NOT RECOVERABLE and cannot be reset without the original text. Both the user name and password are case sensitive. Make sure to note any capitalization changes in either field when defining or changing them. The system owner should document the new Administrator password, store it in a secured location (a vault, safe deposit box, or off-site storage), and have it available for future use. This document should be updated after any password change is made. Intel Active Management with System Defense Feature Quick Reference Guide 17

User accounts can also be setup with limited access rights. If access is limited, then that user will see a padlock icon on the links to the pages that the account cannot access. Figure 9. Intel AMT User Accounts Screen 18 Intel Active Management with System Defense Feature Quick Reference Guide

Troubleshooting I can ping the client system, but cannot connect using a web browser Make sure you changed the client system s default Intel Management Engine password in the BIOS. Make sure you are using a valid user name and password. Make sure that you are connecting to the correct http interface (http, not https) and the correct port (16992). After the operating system loads, I can't connect to the client system If you have installed the correct base driver and are working in DHCP mode, try to manually renew the DHCP lease. The client system is not reachable over the network If the operating system is up, make sure that the DHCP/Static IP settings of Intel Management Engine and the operating system driver are compatible. For example, if the driver is configured to DHCP and Intel Management Engine to use a static IP, then the Intel AMT device is in effect isolated from the network. Login fails after a successful login If the link is followed by a padlock icon, the user account you are using does not have rights to access this page. You must log in using an account with sufficient rights. Intel Active Management with System Defense Feature Quick Reference Guide 19

20 Intel Active Management with System Defense Feature Quick Reference Guide