Duplex Filters 40 FLDK 0008(C)-0120(C)



Similar documents
Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

HFS and HFD Series. High Flow Single and Duplex Filters Max l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information:

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Backflush filter R8-30W

15/40/80CN Series Medium Pressure Filters

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

API Flanged Safety Relief Valves Series 526 CATALOG

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Filter Housing SG Standard

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Type 3353 Angle Seat Valve

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

VAG Non-Return Valves

Pressure regulating valve with modulating kit, type DRV

Bypass level indicator With magnetic display Model BNA

2/2 and 3/2 Way Size 6 Seat Valves

Proportional Relief Valves

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Overflow valve with thread connection

P.E.D. 97/23/EC/0424 Butterfly Valves Series SL, SLK Group 1-2 Class I, II, III ATEX CE Ex II 2 GD

3/2-way Mini Solenoid Valve

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Assisted lift operated 2/2-way solenoid valves Type EV250B

MFP14, MFP14S and MFP14SS Automatic Pumps

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

TN2000 Series Pneumatic Piston Actuators for DN125 to DN300 SPIRA-TROL Series Control Valves

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

3/2-way Solenoid Valve, direct-acting, NC or NO

ARI-ASTRA / ASTRA Plus Combinend flow regulating valve

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Self-operated Temperature Regulators Temperature Regulator Type 1u

Fixed displacement vane pumps

DIESEL FUEL CONDITIONING

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

SERIES FRI. Maximum working pressure 20 bar F l o w r a t e t o l / m i n. s. p. a

Filter Elements E /05.06

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

ALMATEC Series CX CX 10 CX 130

Standard Hydraulic Piping Flushing Procedure

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

QLM and QLD Series Three-port Control Valves

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

REPAIR AND MAINTENANCE MANUAL

T U R B I N E G A S M E T E R

Pressure reducing valve, direct operated, Type ZDR 6 D

CSF16 and CSF16T Stainless Steel Steam Filters

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

ETC -SV. Class 0 oil-free compressed air through catalysis

Hydraulic control unit series

PRESSURE REDUCING CONTROL VALVE

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

300 Series PA Pump and Cooler Assemblies

2- and 3-port valves with flanged connections, PN 10

SOLENOID VALVES AND PNEUMATIC VALVES

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Vacuum Gate Valve DN 100 and DN 150

In-Line Filters and Coalescers with Automatic Drains

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

kymanual or Automatic - it s your Choice

Grey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6

Hydraulic Flow Control Valves

PRESSURE REDUCING VALVES

CSD WATER REMOVAL FILTERS FOR DIESEL

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Valve systems Base plates, according to standard ISO Brochure

1805 Series Relief Valves

Colima Visco and Colima Viscorol Magnetic Level Indicators

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Solenoid valves 2/2-way direct-operated Type EV210A

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

ThermoSorb Desiccant Dryers

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

15/40/80CN Series Coreless Medium Pressure Filters

Air Eliminators and Combination Air Eliminators Strainers

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Single sub-base valve

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side

CRN A-F-G-E-HQQE 3x400D 50 HZ

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

Grey cast iron SG iron Forged steel/ Cast steel Stainless steel Fig. 631 Page 2. High temperature steel Fig. 631 / Fig. 632 Page 8

Cable Plug acc. to DIN EN , Form A

Transcription:

Industrial Filters Accumulators Duplex Filters 40 FLDK 0008(C)-0120(C) Filters for inline installation for continuous operating Ball valve change over Optimised flow characteristics by 3D computer aided design Operating pressure 40 bar Connections up to DN 80 Low pressure drop Special high efficient filter media Quality assured!

Duplex Filters 40 FLDK 0008(C) - 0120(C) Operating pressure 40 bar Operating temperature -10 C to + 100 C Connections up to DN 80 Performance Characteristics Oil Viscosity: 30 mm 2 /s Specific gravity: < 0.9 kg/dm 3 Pressure drop curves for filter assemblies. Recommended initial p pressure drop for filter selection = 0.8 bar Recommended max. velocity = 3.5 m/s Application Filtration of pressurised liquids and lubricants. Filtration of liquids and gases. Direct installation in pipelines. Direct wear protection of subsequent components and systems. Continuous operation due to duplex filter design. Design Two filter housings in cast iron, connected with a ball valve change - over unit with integrated pressure equalisation. Connections for inlet and outlet on same side mounted vertically at the filters face. Material: as per spare parts list in this brochure Filter Element Pleated design with optimised pleat density and various filter media. The filter element is the most important component of the filter in view of prolonged life and wear protection of the system. Oil cleanliness, the initial pressure drop and the dirt holding capacity are the most important criteria for selection. For further detailed information please refer our "Filter Elements" brochure. A proper filter selection is enabled by our "EPE - FILTERSELECT" software. Accessories Maintenance Indicators For monitoring the filter element's contamination status, optical and optical/electrical indicators, with one or two switching points are available. Bypass Valve To protect the filter element during start up and over pressurisation due to clogging. Vent Valve For removing the air from the filter during starting and for safe de-pressurisation. 2

Ordering information Selection of filter size: using the computer program EPE - FILTERSELECT or performance characteristics in this brochure. Special designs available on request. FLDK= Type Duplex filter with ball valve change - over Magnet 0 = Without Maintenance Indicator 0= Without A = Maintenance indicator visual B = Maintenance indicator visual/ electrical with electric plug D = Maintenance indicator visual/ electrical with luminous diodes and two switching points Switching pressure: 2.5 bar See illustrations of maintenance Daten indicator for detailed information and technical data! Connection D0 = DINflange Material 0 = Standard Filter Assembly D 40 FLDK 0008 H10SL A 00 0 7 B2,5 D0 P 0 0 Seal Kit D 40 FLDK 0008 H10SL B D0 P 0 Pressure 40 bar Filter- Element Type 1. Size 0008 (C) 0013 (C) 0015 (C) 0018 (C) 0020 (C) 0030 (C) 0045 (C) 0060 (C) 0095 (C) 0120 (C) (C) = coreless filter element Filtration Grade Nominal filter fineness in µm G = Stainless steel wire mesh, cleanable G10 G25 G40 G60 G80 G100 VS = Nonwoven media, non cleanable VS25 VS40 VS60 P = Paper, not cleanable P5 P10 P25 Absolute filtration grade (ISO 4572) in µm H SL = Micro glass-fibre, non cleanable H1SL H3SL H6SL H10SL H20SL AS = Micro glass-fibre, water adsorbent, non cleanable AS1 AS3 AS6 AS10 AS20 Diff. Pressure Max. allowable differential pressure of the filter element A = 30 bar Element Model 0 = Standardadhesive T = 100 C E = Specialadhesive T = 160 C 0 = Standardmaterial V = Stainless steel 1.4571 Bypass Valve Operating pressure 0 = Without 7 = 3.5 bar Always 0 for filter element Seal P=Buna N V=Viton E=Ethylene Propylene N=Neoprene Addit. Info 0 = Without 5 = Silicone free E = Vent valve Z = Inspection certificate 5 = Silicone free Z = Inspection certificate Filter Element 1. 0008 H10SL A 00 0 P Maintenance Indicator The maintenance indicator monitors the degree of clogging of the filter elements. They are available as visual or visual/electrical displays. See "Maintenance Indicator" brochure for technical data. Filter Switching Symbol A A Visual B Visual/Electrical D Visual/Electrical with three 24 V diodes and two switching points Ordering information A2,5 = G2,5 A0 00 00P* Ordering information B2,5 = G2,5 GW 02 00P* Ordering information D2,5 = T2,5 GW 09 Z0P* B Switching Symbol Switching Symbol V1 LED/ green in use V2 LED/ red S=100% V3 LED/ yellow S=75% *P = Buna N, V = Viton, E = Ethylene Propylene, N = Neoprene possible 3

Dimensions Switch lever indicates operating side Type Capacity Weight A1 A2 A3 2) A4 A5 B1 B2 B3 B4 B5 C1 C2 C3 D1 in l in kg 1) 40 FLDK 0008 (C) 2 x 1,5 39 416 160 40 FLDK 0013 (C) 2 x 2,0 42 506 250 155 110 399 274 92.5 77.5 70 DN 25 ø125 M12 18 95 40 FLDK 0015 (C) 2 x 1,5 39 416 164 40 FLDK 0018 (C) 2 x 2,0 42 506 254 40 FLDK 0020 (C) 2 x 4,0 90 160 584 40 FLDK 0030 (C) 2 x 4,0 90 70 250 210 210 629 375 149 100 85 DN 50 ø158 M16 23 40 FLDK 0045 (C) 2 x 6,0 97 739 400 40 FLDK 0060 (C) 2 x 9,0 152 686 250 40 FLDK 0095 (C) 2 x 9,0 152 836 100 400 230 230 729 484 155 115 130 DN 80 ø188 M20 22 40 FLDK 0120 (C) 2 x 16,0 161 1193 757 1) = weight including standard filter element and maintenance indicator 2) = servicing height for filter element replacement 4

Spare Parts List Size 0008(C) 0013(C) 0015(C) 0018(C) 0020(C) 0030(C) 0045(C) 0060(C) 0095(C) 0120(C) Part Quantity Designation Material 1 2 Filter housing GGG 50 please indicate ordering information Filter 2 2 Filter head GkAlSi10Mg please indicate ordering information Filter 3 2 Filter element various please indicate ordering information Filter Element 4 1 Ball valve combination various please indicate ordering information Filter 5 1 Maintenance indicator various please indicate ordering information Maintenance Indicator 6 2 O-ring Buna N/Viton please indicate ordering information Seal Kit 7 2 Filter element locator AlCuMgPb please indicate ordering information Filter 8 6 Hexagon head cap screw 8.8 Part No. 637 Part No. 652 9 2 Filter element locator AlCuMgPb please indicate ordering information Filter 10 2 Bypass valve or Blanking plug various 11 2 DIN flange C22 12 2 Measuring connection various Part No. 5118 Part No. 793 Part No. 5204 Part No. 1282 13 2 Sealing ring Soft iron please indicate ordering information Filter 14 2 O-ring Buna N/Viton please indicate ordering information Seal Kit 15 2 O-ring Buna N/Viton please indicate ordering information Seal Kit 16 2 Blanking plug St - Part No. 789 17 2 Sealing ring Soft iron please indicate ordering information Seal Kit 18 2 Blanking plug St - Part No. 770 19 2 Sealing ring Soft iron please indicate ordering information Seal Kit 20 16/32 Stud 8.8 Part No. 9587(16x) - 21 16/32 Hexagon nut 5 Part No. 683(16x) - 22 2 Arrest screw various 23 2 Sealing ring Soft iron Part No. 5360 Part No. 825 Part No. 5296 Part No. 4969 Part No. 9586(16x) Part No. 684(16x) Part No. 9586(32x) Part No. 684(32x) Part No. 4844 please ind. ordering inf. Seal Kit Quality and Standardisation The development, manufacture and assembly of EPE-industrial filters and filter elements is carried out within the framework of a certified quality-management-system in accordance with DIN EN ISO 9001. Certification of the filters by accredited institutions (for example TÜV, GL, LRS, LRIS, ABS, BV, DNV, DRIRE, UDT etc.) is available on request. The stability calculation and testing of the filters proceeds according to existing pressure vessel regulations, as well as in accordance with national and international norms. The CE - identification mark according to the Pressure Equipment Directive 97/23/EG depends upon the individual application and operating conditions. On request we will classify the filters. 5

Industrial Filters Accumulators Installation, Starting and Maintenance Filter Installation Verify operating pressure with name plate information. Mount the filter housing Part 1 using mounting device considering flow direction (direction arrows) and servicing height required for cleaning/replacing filter elements. Connection of Electrical Maintenance Indicator See brochure 64 and list acc. this brochure Starting Switch on system pump. Open pressure equalisation. De-aerate filter by opening the vent valve Part 12, close when liquid emerges from valve. Leave pressure equalisation open. Maintenance The filter element is clogged and must be changed or cleaned when at operating temperature the red pointer on the maintenance indicator Part 5 is hard against the plastic cap and/or the switching process on the electrical indicator is triggered. Filter Element Service Operate switching lever and switch to filter housing out of service. Close pressure equalisation. De-pressurise filter out of service by opening vent valve Part 12 one turn. Open plugs Part 16 + Part 18 and drain contaminated oil. Unscrew filter head Part 2. Remove filter element Part 3 from filter housing Part 1 turning slightly off from its locator in the filter lower part. Close plugs Part 16 + Part 18 and vent valve Part 12. Control cleanliness of filter housing. Replace filter element H... SL, VS, AS and P..., the filter element with G... media is cleanable. The efficiency of the cleaning process depends on the characteristics of contamination and the final pressure drop prior to servicing /cleaning the element. If the differential pressure after the filter element's cleaning process exceeds more than 50% of the pre service value the G... element also needs to be replaced. Lubricate filter element O-ring and install replaced or cleaned filter element inside filter housing by putting it up to its locator and slightly turning. Take care not to damage pleated filter element matrix during installation in filter housing. Check O-ring Part 14 in filter head, replace in case of damage or wear. Screw on filter head without using a tool until the end of the thread. Turn it back 1 / 4 thread turn. Open pressure equalisation. De-aerate filter by opening the vent valve Part 12, close when liquid emerges from valve. Leave pressure equalisation open. K. & H. Eppensteiner GmbH & Co. KG Hardtwaldstraße 43 D-68775 Ketsch P.O. Box 1120 D-68768 Ketsch Phone: +49 62 02 /6 03-0 Telefax: +49 62 02 /6 03-199 E-Mail: info@eppensteiner.de Internet: www.eppensteiner.de Warning Assemble and disassemble filter only when system is switched off! Vessel is under pressure! Leave pressure equalisation valve closed while filter housing is out of service! Do not operate switching device while filter housing is out of service! Do not change maintenance indicator or pressure equalisation valve when filter is under pressure! Functions and safety warranty only with EPE-spare part! Service filter only by trained personal! Technical modifications reserved! 6 50D-GB/01/12.02/2000