I O N P R O D U C T S. Sensor Geophones



Similar documents
T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Building a simple seismometer

Sound science. Rugged reliability.

AP Series Autopilot System. AP-202 Data Sheet. March,2015. Chengdu Jouav Automation Tech Co.,L.t.d

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

AP Physics C. Oscillations/SHM Review Packet

SEISMIC MONITORING & PROTECTION SYSTEMS

Accuracy counts! SENSORS WITH ANALOG OUTPUT

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

SINEAX U553 Transducer for AC Voltage

Physics 41 HW Set 1 Chapter 15

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

SEISMIC VELOCITY TRANSDUCER T1-40

Candidate Number. General Certificate of Education Advanced Level Examination June 2012

Asset Condition Monitoring Solutions

Why a torque measuring system?

PHYS 101-4M, Fall 2005 Exam #3. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Environment-Laboratory Ambient Conditions

Practice Test SHM with Answers

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Problem / Solution. The problem:

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Candidate Number. General Certificate of Education Advanced Level Examination June 2014

AP1 Oscillations. 1. Which of the following statements about a spring-block oscillator in simple harmonic motion about its equilibrium point is false?

Address for Correspondence

RI-80 SMD Series Dry Reed Switch

HB Hysteresis Brakes and MHB Matched Brakes

Circuit Breakers. NRC Series. NRC Series

SKR - industry relay

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Agilent 4339B/4349B High Resistance Meters

EGSTON Standard E2xFxWx 12W

1) The time for one cycle of a periodic process is called the A) wavelength. B) period. C) frequency. D) amplitude.

reach trucks UNS/UHS, USS, UFS & URF Nissan Forklift Europe B.V. CEN-RT-NFE/ Printed in the Netherlands

Analog signal converters CC-E I/I Current / current isolators

3-Component Measuring System

Series 6000 Torque measured metal bellow coupling

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

9000 Series Accelerometers Specifications

THE STRUCTURAL HEALTH MONITORING SYSTEM OF THE RION ANTIRION BRIDGE CHARILAOS TRIKOUPIS. Akis Panagis

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Loudspeaker Parameters. D. G. Meyer School of Electrical & Computer Engineering

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max

SCHATZ - TEST Tool testing systems. SCHATZ -certest-w. Dynamic testing of torque tools

Operating instructions

Rosemount 333 HART Tri-Loop

Acceleration due to Gravity

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Voltech DC1000. Precision DC Bias Current Source

FM Radio Transmitter & Receiver Modules

Alternative Linear Motion Systems. Iron Core Linear Motors

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

MANUAL TR-110 TR-110

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

ENCLOSURE DESIGN I S 2008

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

226 Chapter 15: OSCILLATIONS

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

Print and Apply Solutions Applicator Overview

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Physics 231 Lecture 15

Providing a complete Ethernet anywhere solution. IS Ethernet Solutions

Contents. Document information

Data in seismology: networks, instruments, current problems

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

AGV / Lift AGV. Automated Container Transport Proven Technology from Gottwald

T U R B I N E G A S M E T E R

ROC800-Series Advanced Pulse Module

Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.

! n. Problems and Solutions Section 1.5 (1.66 through 1.74)

Subminiature Load Cell Model 8417

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

EFFECTS ON NUMBER OF CABLES FOR MODAL ANALYSIS OF CABLE-STAYED BRIDGES

Torque motors. direct drive technology

Low Frequency Velocity Sensor

Handheld portable appliance testers

Velomitor Piezo-velocity Sensor

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

1 WATERFLUX - Comparisonon COO Rectangular Magmeter in water applications

Proximity Transmitters and Seismic Vibration Transmitters

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

Active Vibration Isolation of an Unbalanced Machine Spindle

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Towed Streamer Positioning System

Thermal-Magnetic Circuit Breaker M1-..

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

R&S SMZ Frequency Multiplier Specifications

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

VSO MAX HP High Flow Proportional Valve

and Accelerometers

The Do s and Don ts of Pressure Transducers

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Transcription:

I O N P R O D U C T S Sensor Geophones

Sensor ION s Sensor subsidiary is the leading designer and manufacturer of precision geophones used in seismic data acquisition and for industrial use. Sensor has access to the vast wealth of knowledge acquired and developed by the ION group of companies. This valuable asset base, coupled with Sensor s own specialized skills and knowledge, provides unmatched diversity of technologies and innovation. ION Sensor Since 1967 ION Sensor has been providing geophysicists worldwide with exceptional quality precision geophones, testers and ancillary equipment.our SM-24 rotating coil geophone is the industry leader with an installed base of well over 14 million elements worldwide. Sensor s dedication to quality is unsurpassed in the industry. Hard wearing, long lasting geophones save our customers millions of dollars every year in costly repairs and minimize crew down time. As market leader and a multisite ISO 9001: 2000 certified company, Sensor maintains production facilities and service support in The Netherlands, USA, Dubai, India, Canada, China, Russia and the UK. From our main plant in Voorschoten, The Netherlands and from our Dubai facility, we produce a geophone every four seconds, well over two million a year. Sensor has access to the vast wealth of knowledge acquired and developed by the ION group of companies Calgary Houston Norwich Voorschoten Jebel Ali Moscow Beijing New Dehli

Maintain Your Specifications Measurements of vibration can be traced back many centuries to the Chinese and Egyptians who used devices that would allow marbles or pebbles to be rolled or cause objects to fall in order to determine levels of vibration. Today s geophones are sophisticated measuring devices and are based on a coil suspended by springs in a magnetic field, within a steel case. When vibration of any sort moves the case, the coil remains stationary due to its inertia. This movement of the case in relation to the stationary coil generates an electrical voltage proportional to the velocity of the coil with respect to the case (with displacements as low as nano-meters). The seismic industry today demands tight specification tolerances in order to meet the exacting standards of a modern seismic survey and ION Sensor has set the industry standard. For example a geophone with a 10Hz natural frequency will operate within +/- 2.5% tolerance; harmonic distortion will be <0.1%, sensitivity and coil resistance both +/- 2.5% and the damping set at +5% and -0%. To achieve these specifications The SM-24 geophone element is designed to offer the highest performance in seismic exploration based upon field-proven ION Sensor technology. Geophone coils awaiting assembly the product has been refined over many years and today s products are a far cry from the cumbersome geophones used in seismic surveys 40 years ago. Geophones of poor quality will provide equally poor data with the result that the map or section is no longer analogous of the earth s interior. In addition to tight specifications geophones need to be exceptionally rugged in their design: In the field strings are routinely stepped on, kicked around, thrown out of the back of trucks and in some case, even dropped out of helicopters. Although some competitors specify their products to match the industry standard, many avoid the rigors of accelerated age testing. This results in high levels of field failure as products move out of specification and lead to a high total cost of ownership. PE-3/C land case Economical, field proven reliability for more than 20 years.

Sensor Geophones Sensor s SM-24 geophones are the industry leading technology for analog seismic acquisition SM-24 Rotating Coil Geophone Tight specification, low-distortion geophone Extended spurious over 240 Hz, allowing full bandwidth at 2-ms sampling Backwards compatible with SM-4, SM-4 Superphone Horizontal element available for shear-wave and 3-C recording 3-year non-prorated warranty Lowest lifecycle cost of ownership in the industry Installed base of over 14 million worldwide (est.) The SM-24 geophone element is designed to offer the highest performance in seismic exploration based upon field-proven ION Sensor technology. Low distortion, combined with excellent specifications, provide high-fidelity data in 2-D and 3-D surveys. The extended bandwidth allows the full potential of 2-ms/24-bit recording systems to be realized. The tight specifications, unique element design, and exceptional quality of the Sensor SM-24 make it the lowest life cycle cost of ownership geophone in the industry. Applications: 2-D & 3-D seismic exploration with bandwidth from 10 Hz up to 240 Hz. Implementation: Can be installed in a variety of ION Sensor geophone cases.

Specifications: SM-24 Geophone Element FREQUENCY Natural frequency 10 Hz Tolarance ± 2.5% Maximum tilt angle for specified Fn 10 Typical spurious frequency >240 Hz DISTORTION Distortion coil to case velocity with 17,78 mm/s (0,7 in/s) p.p. <0.1% Distortion measurement frequency 12 Hz Typical distortion (string of 12 in series measured at 12 Hz) 0.03 % DAMPING Open circuit (Typical) 0.25 Damping calibration-shunt resistance 1,339 Ω Damping with calibration shunt 0.6 Tolerance with calibration shunt + 5%, -0% SENSITIVITY Sensitivity 28.8 V/m/s (0.73 V/pulg./s) Tolerance ± 2.5 % RtBcFn 6,000 Ω Hz Moving mass 11 g (0.38 oz) Max coil excursion p.p. 2 mm (0.08in) SM-24 10 Hz Response curve SM-24 10 Hz Phase lag COIL RESISTANCE Tolerance +/- 2.5% PHYSICAL CHARACTERISTICS Diameter Height Weight Operating temperature range WARRANTY PERIOD* 25.4 mm ( 1 in) 32 mm (1.26 In) 74 g (2.6 oz) -40 C a +100 C (-40 F a +212 F) 3 years *Warranty excludes damage caused by high voltage and physical damage to the element case. All parameters are specified at +20 C in the vertical position unless otherwise stated.

Sensor Geophones SM-4 8 Hz Response curve SM-4 Precision machined, rotating coil design Precious metal contacts for consistent, reliable & prolonged fieldperformance. Choice of three standard natural frequencies (8Hz, 10Hz and 14Hz) Vertical and Horizontal elements available for 3-C applications. 3-year non-prorated warranty SM-4 10 Hz Response curve The SM-4 digital-grade geophone element is designed for low weight, long field-life, and ultra reliable performance. Precision engineered components and computerized test equipment ensure consistency in manufacture and operation throughout and beyond the replacement guarantee period of three years. Applications: 2-D and 3-D seismic exploration with bandwidth from 10 Hz up to 190 Hz. SM-4 14 Hz Response curve Implementations: Can be installed in a variety of standard ION Sensor geophone cases.

Specifications: SM-4 Geophone Element FREQUENCY SM-4/U-B 8Hz SM-4/U-B SM-4/U-B 10 Hz 14 Hz Natural frequency 8 Hz 10 Hz 14 Hz Tolerance ± 6.3% ± 5% ± 5% Maximum tilt angle for specified Fn 20 25 25 Typical spurious frequency 160 Hz 180 Hz 190 Hz DISTORTION Distortion coil to case velocity with 17.78 mm/s (0.7 in/s) p.p. <0.2% <0.2% <0.2% Distortion measurement frequency 12 Hz 12 Hz 14 Hz Maximum tilt angle for distortion spec 15 20 20 DAMPING Open circuit damping 0.315 0.25 0.18 Damping calibration-shunt resistance 2,257 Ω 1,339 Ω 645 Ω Damping with shunt 0.6 0.6 0.6 Tolerance with shunt ± 5% ± 5% ± 5% SM-4 8 Hz Phase lag SENSITIVITY Sensitivity 28.8 V/m/s 28.8 V/m/s 28.8 V/m/s (0.73 V/in/s) Tolerance ± 5 % ± 5 % ± 5 % RtBcFn 6,000 Ω Hz 6,000 Ω Hz 6,000 Ω Hz Moving mass 11 g 11 g 11 g (0.38 oz) Max coil excursion p.p. 2 mm 2 mm 2 mm (0.08 in) SM-4 10 Hz Phase lag COIL RESISTANCE Standard 375 Ω 375 Ω 375 Ω Tolerance +/- 5% +/- 5% +/- 5% PHYSICAL CHARACTERISTICS Diameter 25.4 mm 25.4 mm 25.4 mm ( 1 in) Height 32 mm 32 mm 32 mm (1.26 in) Weight 74 g 74 g 74 g (2.6 oz) Operating temperature range -40 C a +100 C -40 C a +100 C -40 C a +100 C (-40 F a +212 F) WARRANTY PERIOD* 3 years 3 years 3 years SM-4 14 Hz Response curve *Warranty excludes damage caused by high voltage and physical damage to the element case. All parameters are specified at +20 C in the vertical position unless otherwise stated.

Netherlands SENSOR Nederland b.v. Rouwkooplaan 8 2251 AP Voorschoten The Netherlands Phone: +31 (0)71 5601234 Fax: +31 (0)71 5617145 UK Leiden House, Delft Way Norwich International Business Park Norwich, Norfolk NR6 6BB England Phone: +44 (0) 1603 481000 Fax: +44 (0) 1603 411403 Dubai ION Dubai UAE Oilfields Supply Center Ltd B-23 Jebel Ali Free Zone PO Box 18627, Dubai, United Arab Emirates Phone: +971 4 883 3362 Fax: +971 4 883 3067 USA 12300 Parc Crest Drive Stafford, TX 77477 USA Phone: + 1 281 933 3339 Fax: + 1 281 879 3626 China First Shanghai Center Suite 302 39 Liang Ma Qiao Road Beijing 100016, PR China Phone: +86 10 8453 4350 Fax: +86 10 8453 4351 Canada 2905, 500-4th Avenue SW Calgary, Alberta T2P 2V6 Phone: + 1 403 213 8769 Fax: + 1 403 263 9132 Russia ION Moscow Russia Busines center Navigator Varshavskoye Sh. 47/4 Moscow, Russia 115230 Phone: +7 495 981 4601 Fax: +7 495 981 4606