Microwave Meter. Instruction Manual



Similar documents
Light Meter (Foot Candles)

AutoRanging Digital MultiMeter

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

USER GUIDE. LED Light Meter. Model LT45

High Temperature InfraRed Thermometer with Laser Pointer

RS DIGITAL THERMOMETER

Pocket Tach 99 (PT99) Non-Contact Tachometer

SOUND LEVEL METER 94405

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

INSTRUCTION MANUAL DTH Fax: (503)

Mold Alert... Operation Manual P0270

MULTI-FIELD EMF METER. TM-190 User s Manual B2TM

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

ExStik TM ph Waterproof Meters

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Dual Laser InfraRed (IR) Thermometer

4-Channel Thermometer / Datalogger

Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer

User's Guide. Pinless Moisture Meter. Model MO257

Wireless Indoor/ Outdoor Thermometer

UT202A Operating Manual. Contents

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Measuring electric and magnetic fields

Ultrasonic Distance Meter. Operation Manual

Instruction Manual Temp 4/5/6 Temperature Meter Series

Hygro-Thermometer + InfraRed Thermometer Model RH101

Manual Ranging MultiMeter

Professional Thermohygrometer

Model: Manual DC: WIRELESS COLOR FORECAST STATION

DSM155 Digital LED Light Meter User s Manual DSM155

User Manual. Humidity-Temperature Chart Recorder. Model RH520

323/324/325. Calibration Manual. Clamp Meter

T TPMS Tool Manual 1. T55003 INTRODUCTION 2. KEYPAD SUMMARY AND FUNCTIONS

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

User's Guide. True RMS Industrial Multimeter

User Guide. Model Insulation Tester / Megohmmeter

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Temperature Humidity Meter

WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL

Model UT201/202: OPERATING MANUAL. Table of Contents

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

WIRELESS WEATHER STATION Model USER'S INSTRUCTIONS

WIRELESS FORECAST STATION

62 Max/62 Max + Infrared Thermometer

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Ground Resistance Clamp On Tester

AM / FM Tuner + RDS. Model: TU

Thermocouple Thermometer Models

Ground Resistance Clamp-On Tester

Instructions A Amp AC/DC Current Probe

Atomic Alarm Clock Instruction Manual

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Wolverine Data PASS Portable Scanner User Manual V1.0

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Thermistor Thermometer MODEL NO

MEMO ALARM CLOCK Operating Manual

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Integrating Sound Level Meter and Datalogger

IN-OUT Thermometer with Cable Free Sensor and Clock

Atomic Projection Alarm with Indoor and Outdoor Temperature

Weather Radio Alarm Clock

How To Use A Cdm250 Digital Multimeter

WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No User s Manual

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Drayton Digistat +2RF/+3RF

User's Guide Integrating Sound Level Datalogger Model

User Guide. Temperature and Humidity Datalogger. Model 42280

User's Guide. Digital Sound Level Meter. Model

User s Manual AURORA 1.2K/2.2K

Model UT33A: OPERATING MANUAL Table of Contents (1)

Dual Laser InfraRed (IR) Thermometer

Digital Wireless Rain Gauge & Thermometer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

How To Use A Power Supply Unit (Upu)

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

AD-01 Slave Auto Dialer. Owner s Manual

HVAC Clamp Meter. Users Manual

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

AM/FM Portable Radio

ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE

AM/FM PLL Clock/Table Radio

Wireless Home Security Alarm System AM 500

GSM Alarm System User Manual

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

The Weather Station. Hanging Hole. LCD Display Battery Cover. Function Keys. Detachable Stand

Auto Dialer. Manual E-921APQ E-921GPQ

Part # rev 1. American Diagnostic Corporation 55 Commerce Drive, Hauppauge, New York

CAD-05 Kit GSM Auto Dialer. Owner s Manual

i410/i1010 AC/DC Current Clamp

Operating Manual Remote Cost Control Monitor

Transcription:

Microwave Meter 840046 Instruction Manual

Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. - 2 -

TABLE OF CONTENTS INTRODUCTION............... FEATURES................... MATERIALS SUPPLIED......... KEYPAD...................... MEASUREMENT PROCEDURES.. BATTERY REPLACEMENT....... MAINTENANCE................ OPTIONAL ACCESSORIES...... SPECIFICATIONS.............. WARRANTY.................. 4 5 6 7 8 16 16 17 18 20-3 -

INTRODUCTION Measure hazardous microwave oven leakage With use microwave oven door seals may wear enabling hazardous microwaves to leak out. Sper Scientific Microwave Meter is calibrated at 2.45 GHZ, the precise frequency of microwave ovens to accurately measure the intensity of such microwave leakage. Features maximum and minimum hold, an audible alarm, and a zero adjustment to eliminate background EMF. The display also indicates overload and low battery. Comes with a soft carrying case and standard 9V battery, which provides approximately 100 hours of use. - 4 -

FEATURES Frequency selection of normal or microwave range Tripod mounting socket Maximum and minimum Hold function Auto-power-off Built-in alarm Zero offset adjustment Overload indicator Low battery indicator - 5 -

MATERIALS SUPPLIED Meter 9 Volt Battery Instruction Manual Soft Carrying Case - 6 -

KEYPAD 1. Sensor position 2. LCD 3. Zero button 4. Power on/off 5. Maximum/minimum button 6. Frequency range selection button 7. Data hold button 8. Tripod mounting socket 9. Battery cover - 7 -

MEASUREMENT PROCEDURES 1. Press POWER to turn the meter on. 2. Press FREQ. RANGE to select microwave (2.45 GHZ) or RF (50 MHZ~3.5 GHZ). When 2.45 GHZ is selected, 2450 MHZ will appear on the lower right corner of the LCD. When normal range is selected, 2450 MHZ will disappear from the lower right corner of the display. 3. For general information on microwave oven leakage and instructions on preparing for microwave measurement, see page 14. 4. Position the top of the meter to measure the electromagnetic waves. Adjust the measurement angle or position until the highest reading is obtained. - 8 -

MEASUREMENT PROCEDURES Measurement Position Figure 1 shows the correct measurement position of RF electromagnetic field strength. Figure 2 shows the incorrect measurement positions of RF electromagnetic field strength. Figure 1 Figure 2-9 -

MEASUREMENT PROCEDURES Note Due to background environmental magnetic fields, this meter may display a reading value under 0.002 mw/cm 2 prior to measuring. Maximum, Minimum and Hold 1. Press MAX/MIN to retain the maximum value. MAX will appear on the LCD. The meter will continue measuring, holding the maximum value on the LCD until exceeded. 2. Press MAX/MIN again to retain the minimum value. MIN will appear on the LCD. The meter will continue measuring, holding the minimum value on the LCD until exceeded. 3. Press MAX/MIN again to retain the maximum and minimum values simultaneously. MAX MIN will - 10 -

MEASUREMENT PROCEDURES flash on the LCD. The meter will continue measuring, holding the maximum and minimum values on the LCD until exceeded. 4. Press and hold MAX/MIN for more than one second to exit and return to Normal Mode. 5. Press HOLD to freeze the current value on the display. DH (Data Hold) will appear on the LCD. Press HOLD again to release the data hold. Auto Power Off 1. To save battery life, the meter will automatically turn off after 30 minutes of inactivity. To disable this function: - 11 -

MEASUREMENT PROCEDURES 2. Press POWER to turn the meter off. Press and hold MAX/MIN while simultaneously pressing POWER to turn the meter on. Auto-power-off is now disabled. 3. To restore auto-power-off: Press POWER to turn the meter off and then press POWER again to turn the meter back on. will appear on the LCD to indicate that auto-power-off is enabled. Alarm The meter features a built-in alarm that will sound when the measurement exceeds 1 mw/cm 2. The alarm will stop sounding when the measurement falls under 1 mw/cm 2. This threshold value cannot be changed. - 12 -

MEASUREMENT PROCEDURES Zero Offset Adjustment If the meter shows a measurement other than 0 due to background EMF, zero adjusting will eliminate this electromagnetic interference. Press ZERO to adjust and obtain a 0 measurement. ZERO will appear on the LCD. Overload Indicator When the reading exceeds 4 mw/cm 2, OL will appear on the LCD to indicate overload. Low Battery Indicator The symbol will appear on the LCD to indicate a low battery. Replace the battery (see page 16). - 13 -

MEASUREMENT PROCEDURES Microwave Oven Leakage With time, microwave leakage around door seals, hinges and metal fittings is not uncommon. Therefore, it is important that all microwave ovens be periodically checked to ensure that no damage or malfunction has occurred. Microwaves may easily pass through porcelain, glass, ceramics and most plastics. Highly potent microwave energy generated by microwave ovens is also capable of penetrating living tissue to a depth of approximately 1.18 (30 mm). Do NOT stand or look directly into any area where microwave leakage may be present. Remove any rotating plates, etc. before testing. - 14 -

MEASUREMENT PROCEDURES 1. Because microwave ovens should not be operated while empty, fill a microwave safe container with 275 ml of water and place it in the center of the oven during testing. 2. Start the microwave at maximum power. 3. Follow the measurement procedures on page 8, concentrating measurements on door seams, window seals, welds and rivets. - 15 -

BATTERY REPLACEMENT 1. Press POWER to turn the meter off. 2. Remove the battery cover on the back of the meter. 3. Remove the old battery and replace with 1 new 9V battery, ensuring correct polarity. 4. Replace the battery cover. MAINTENANCE Use a soft, dry cloth to clean the meter. Do NOT use a wet cloth, solvents, water or any liquid to clean the meter. - 16 -

OPTIONAL ACCESSORIES 840090 Water Resistant Instrument Pouch 840092 Bench-Top Tripod 840093 Field Tripod 850000 Rubber Boot - 17 -

Accuracy SPECIFICATIONS ± 2 db at 2.45 GHZ ± 50 MHZ Resolution 0.001 mw/cm 2 Display RF Power Density RF Frequency 3 3/4 digits LCD; maximum reading 3999 (4 mw/cm 2 ) 0.003 ~ 2.700 mw/cm 2 50 MHZ ~ 3.5 GHZ Microwave Frequency Axis 2450 MHZ Single Sample Rate Operating Temperature & Humidity 2.5 times per second - 18-5 C ~ 40 C 80% RH

SPECIFICATIONS Storage Temperature & Humidity Operating Altitude Operating Environment Battery Battery Life -10 C ~ 60 C 70% RH 2000 M Indoor use; pollution degree 2* 9V NEDA 1604, IEC 6F22 or JIS 006P Approximately 100 hours Dimensions 5 ¼ x 2 ¼ X 1 ¼ (130 x 56 x 38 mm) Weight 6 oz (170 g) *Pollution degree is a classification of the amount of dry pollution and condensation present in an environment. This classification affects clearance distances required for product safety. Office and laboratory areas are considered pollution degree 2 environments. - 19 -

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD 8281 E. Evans Rd., Suite #103 Scottsdale, AZ 85260 The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperscientific.com, or return your warranty card within 10 days of purchase. Revised 6/21/2013-20 -