Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL
|
|
|
- Marion King
- 9 years ago
- Views:
Transcription
1 RS Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL
2 TABLE OF CONTENTS TITLE PAGE INTRODUCTION...1. SAFETY INFORMATION...2. FEATURES...4. SPECIFICATIONS...4. GENERAL LAYOUT AND OPERATING CONTROLS...7. LCD DISPLAY DESCRIPTION...9. EMISSIVITY ADJUSTMENT...9. TEMPERATURE MEASUREMENT SETTING MODE BATTERY REPLACEMENT...17
3 INTRODUCTION The RS 1327K hand-held thermometer is a convenient and easy to use instrument, allowing temperature measurement either by an Infrared non-contact method, or by using a plug-in type-k thermocouple probe. The thermometer has an integral laser to assist sighting the Infrared sensor for making non-contact measurements of items that are inaccessible or hazardous to touch such as rotating machinery, high-voltage bus-bars, or inaccessible objects. The Infrared mode does not rely on physical contact with the object whose temperature is to be taken, but measures the radiated infrared energy from the object. The thermocouple connector will accept a standard liquid, air or surface thermocouple probe as required to suit the particular application. The Liquid Crystal Display has a backlight function which may be enabled to assist measurements made in a dark place. Other features include reading auto-hold, auto power-off, maximum and minimum readings, alarm levels and adjustable emissivity, all of which can be selected for maximum operating convenience. E-1
4 . SAFETY INFORMATION 1. Read the following safety information carefully before attempting to operate or service the meter. Laser Safety Warning LASER RADIATION DO EN :1994/A11:1996 If the MEAS button is pressed while the symbol is shown on the LCD, the meter will radiate the laser. To prevent injury, do not look or stare into the beam. Do not point the laser directly at eyes or indirectly off reflective surfaces. If the target object has a smooth surface, the laser may be reflected and create a hazard. Do not radiate the laser at flammable gasses or other possible sources of ignition. 2. Precautions: a). Do not operate the thermometer in the presence of strong electrical or magnetic fields, as this may prevent correct operation. b). Use and store the thermometer away from direct sunlight or other strong source of light, high temperatures, high humidity or dust. c). If the thermometer has been kept in area of high or low temperature, wait until it has reached a stable temperature before use. E-2
5 d). Condensation may form on the focal lens if the thermometer is moved quickly from a cold to a hot environment. Before taking measurements, wait for the condensation to dissipate. e). Do not touch the focal lens. 3. Environmental conditions: a). Altitude up to 2000 meters. b). Relatively humidity: 80% max. c). Operating ambient temperature: 0 to 50 C 4. Maintenance & Clearing: a). Repairs or servicing should only be carried out by competent persons using the correct parts, test equipment and procedures. If repair or servicing is required, contact the supplier or RS Components. The address is given at the end of these instructions. b). Periodically clean the case with a dry cloth. Do not use abrasives or solvents. 5. Safety symbols: Complies with the EMC Directive 89/336/EEC E-3
6 . FEATURES C/ F Selectable. Backlit LCD display. Sighting laser. Auto-hold function. Maximum/minimum reading recorder function. Auto power-off. Type K thermocouple thermometer.. SPECIFICATIONS 3-1 General Information: Display: Backlit LCD display. Auto power-off time: Approx.15 sec. Data memory capacity: 99 set. (Direct reading on LCD display) Over-range indication: OL or -OL. Low battery indication: The symbol is displayed on LCD when the battery voltage drops below the operating voltage. Power supply: Single 9V battery 006P 9V, IEC6F22, or NEDA1604. Battery life: Approx. 100 hours (with laser pointer and backlight off) Operating temperature: 0 C to 50 C (32 F to 122 F), Operating humidity: Below 80%RH. E-4 +
7 Storage temperature Humidity: Dimensions: Weight: Accessories: 10 C to 60 C (14 F to 140 F), Below 70%RH. 172(L) 118(W) 46(H) mm 6.8(L) 4.6(W) 1.8(H) inches. Approx. 220g with battery. Instruction manual, carrying case, battery. 3-2 Electrical specifications: Measuring range: -35 C to 500 C (-31 F to 932 F) Resolution: 0.1 C, 0.2 F Accuracy: ± 2% of reading or ± 2 C or 4 F (whichever is greater). Temperature coefficient: 0.1 times the applicable accuracy specification per C from 0 C to 18 C and 28 C to 50 C (32 F to 64 F and 82 F to 122 F). Measurement rate: 2 times per second. Spectral Response: 6 to 14um. Field of view: 12:1; optics ratio with a 1 min target. Emissivity: 0.17 ~ 1.00 (adjustable, preset at 0.95) Sighting: Laser marker < 1mw (class 2). Sensor: Thermopile. E-5
8 Type K Measuring range : -150 C to 1350 C (-238 F to 1999 F). Resolution : 0.1 C, 1 C, 0.1 F, 1 F Measurement rate : Once per second. Basic accuracy : (@ 23±5 C calibration) accuracy are ± ( % of reading + degree) at 18 C to 28 C with relative humidity up 80%. Function Resolution Range Accuracy C F 0.1 C -150 C~0 C ( 0.2%rdg C) 0 C~200 C ( 0.1%rdg C) 1 C 200 C~1350 C ( 0.2%rdg + 2 C) 0.1 F -238 F~32 F ( 0.2%rdg + 2 F) 32 F~200 F ( 0.1%rdg + 2 F) 1 F 200 F~1999 F ( 0.2%rdg + 4 F) Temperature Coefficient: 0.1 times the applicable accuracy specification per C from 0 C to 18 C and 28 C to 50 C ( 32 F to 64 F and 82 F to 122 F ). Note : The basic accuracy specification does not include the error of the probe. Please refer to the probe accuracy specification for additional details. E-6
9 . GENERAL LAYOUT AND OPERATING CONTROLS CAUTION AVOID EXPOSURE - LASER RADIATION IS EMITTED FROM THIS APERTURE LASER RADIATION - DO NOT STARE INTO BEAM OUTPUT < 1mW WAVELENGTH nm CLASS (II) LASER PRODUCT Complies with IEC :( ) Edition 1.1, EN :1994/All:1996 K C F Type K E-7
10 1. Display. Button 2. MODE M R Press once Enter MAX/MIN recording mode. MAX MIN Current reading (MAX/MIN) From normal mode will turn the backlight on or off From Read mode, decrements the memory location number. From SET mode decreases the value of the selected parameter. 8. Focal lens. 9. Type K thermocouple input socket. E-8 Press and hold for 3 seconds From MAX/MIN mode will exit this mode and return to normal operation. From normal mode will enter setting mode. Store the displayed reading. From normal mode will enable or disable the laser. From Read mode increments the Read the stored data memory location number. from memory. From SET mode increases the value of the selected parameter. 5. Measuring trigger : Trigger for turning the thermometer on. Pull the trigger to turn on the thermometer and make a measurement. In SET mode, pull the trigger to store the required value and exit SET mode. Press and hold the MODE button, then pull the trigger to enter continuous measurement mode. In continuous measurement mode, pull the trigger to turn the meter off. 6. Battery cover. 7. Laser aperture.
11 . LCD DISPLAY DESCRIPTION K C F 1. Hold function 11. Lo alarm 2. Maximum reading 12. Alarm function 3. Minimum reading 13. Hi alarm 4. Low battery indicator 14. Memory and Read address number 5. Maximum/minimum value 15. Read memory data 6. Emissivity value setting 16. Type K measuring indicator 7. Measured value 17. Memory full indication 8. Measure indication 18. Store data to memory 9. Laser enabled indicator 19. Units C, F 10. SET symbol. Emissivity Adjustment 1. Emissivity: Emissivity is a value between 0.17 and 1 which indicates an object s ability to emit infrared energy. Emissivity is determined primarily by the objects composition and surface finish. The thermometers sensitivity to emissivity ε is preset at 0.95, because this setting will be applicable to 90% of surfaces encountered, but can be adjusted as required. E-9
12 2. Emissivity adjustment Apply black tape, matt-black paint or black magic marker to the object if it is safe to do so. ε is set at 0.95 to indicate correctly from a dark surface. Aim the sensor at the black surface, pull the trigger and note the reading as T1. Remove the black tape or matt-black paint and aim the sensor at the same area again. Pull the trigger and note the reading as (T2). Change the emissivity value ε until T2 and T1 are equal as follows: a). Enter setting mode (refer to MODE button above). b). Press MODE button to select theε value setting. c). Press or buttons to set desired value. d). Pull the trigger to store the setting value and exit set mode. The following table gives typical emissivity values for common materials Emissivity VALUES Typical Emissivity Values; Metals SURFACE EMISSIVITY Zinc (oxidized) 0.1* Galvanized iron 0.3 Tin-plated steel 0.1* Gold (polished) 0.1* Silver (polished) 0.1* Chromium (polished) 0.1* Iron and Steel Cast iron (polished) 0.2 Cast iron (turned at 100 C) 0.45 Cast iron (turned at 1000 C) 0.6 to 0.7 Steel (ground sheet) 0.6 Mild steel 0.3 to 0.5 E-10
13 Steel plate (oxidized) 0.9 Iron plate (rusted) 0.7 to 0.85 Cast iron (rough) rusted 0.95 Rough ingot iron 0.9 EMISSIVITY VALUES Typical Emissivity Values; Metals SURFACE EMISSIVITY Molten cast iron 0.3 Molten mild steel 0.3 to 0.4 Stainless steel (polished) 0.1 Stainless steel (various) 0.2 to 0.6 Aluminum Polished aluminum 0.1* Aluminum (heavily oxidized) 0.25 Aluminum oxide at 260 C 0.6 Aluminum oxide at 800 C 0.3 Aluminum Alloys various 0.1 to 0.25 Brass Brass (polished) 0.1* Brass (roughened surface) 0.2 Brass (oxidized) 0.6 Copper Copper (polished) 0.05* Copper plate (oxidized) 0.8 Molten copper 0.15 Lead Lead (pure) 0.1* Lead (oxidized at 25 C) 0.3 Lead (oxidized, reated to 200 C) 0.6 Nickel and its alloys Nickel (pure) 0.1* Nickel plate (oxidized) 0.4 to 0.5 Nichrome 0.7 Nichrome (oxidized) 0.95 E-11
14 Emissivity Values; Non-metals - Refractory & Building materials Red brick (rough) 0.75 to 0.9 Fire clay 0.75 Asbestos 0.95 Concrete 0.7 Marble 0.9 Carborundum 0.85 Plaster 0.9 Alumina (fine grain) 0.25 Alumina (coarse grain) 0.45 Silica (fine grain) 0.4 Silica (coarse grain) 0.55 Zirconium silicate up to 500 C 0.85 Zirconium silicate at 850 C 0.6 Quartz (rough) 0.9 Carbon (graphite) 0.75 Carbon (soot) 0.95 Timber (various) 0.8 to 0.9 Miscellaneous Enamel (any color) 0.9 Oil paint (any color) 0.95 Lacquer 0.9 Matte black paint 0.95 to 0.98 Aluminum lacquer 0.5 Water 0.98 Rubber (smooth) 0.9 Rubber (rough) 0.98 Plastics (various, solid) 0.8 to 0.95 Plastic films (05 mm thick) 0.5 to 0.95 Polythene film (03 mm thick) 0.2 to 0.3 Paper and cardboard 0.9 Silicone polish (03 mm thick) 0.7 * Emissivity value varies with purity E-12
15 . TEMPERATURE MEASUREMENT 1. Non-contact measurement : Point the instrument at the target and pull the trigger to turn it on and start measuring (use the laser to select the target if required). Release the trigger to stop measuring and auto-hold the reading. The meter will turn off automatically after 15 seconds. Auto detection type K thermocouple plug-in or pull-out. If a type K thermocouple is connected to the instrument, the emissivity symbol ε will automatically change to K and the temperature measured by the thermocouple will be displayed. The Infrared sensor is disabled when a thermocouple is detected by the instrument. 2. MAX/MIN hold function : Pull & hold the trigger, then press MODE once to cycle through maximum (MAX), minimum (MIN) and current reading (MAX/MIN) modes. Press and hold the MODE button for 3 seconds to exit this mode. 3. Continuous measurement : Start with the instrument turned off. Press and hold the MODE button and then pull the trigger to turn the meter on. Release the MODE button and the instrument will enter continuous measurement mode. The H symbol will not be visible in the LCD, indicating the Hold function is disabled To exit continuous measurement mode: Pull the trigger to stop continuous measurement and turn the meter off. MAX/MIN reading: When in continuous measurement mode, press the MODE button once to cycle through maximum (MAX), minimum (MIN) and current reading (MAX/MIN) modes. Press and hold the MODE button for 3 seconds to exit this mode. E-13
16 Note: Laser offset: The laser beam is offset 18mm(0.71in) from the focal lens. Choose a sampling spot that is large enough to include the laser offset. Surface Temperature: The thermometer will measure the temperature of the first surface it detects, e.g. a glass cover, dust or fog. Ensure the object whose temperature is to be measured is not obstructed. 4. Selecting C/ F units: When the instrument is turned on, the units that appear in the LCD are the last units measured. To change the temperature units, pull the trigger to turn the meter on, then press and hold MODE for 3 seconds until the SET mark appears on the LCD. Press or to select the desired C or F units and then pull trigger to store the setting. 5. Data memory store and read procedure : To clear the data from the memory: With the instrument turned off, press and hold the M button, then pull trigger until CLR appears on the LCD. Data memory: Press and hold the M button for 3 seconds to store the current set of readings into memory. E-14
17 Reading the memory data: Press and hold the R button for 3 seconds to enter READ mode. Press the or buttons to select to desired memory data location. Press the MODE button to exit READ mode.. SETTING MODE Pull trigger to turn the meter on. Press & hold the MODE button for 3 seconds until SET appears on the LCD. 1. Parameter settings for measuring: Under the infrared parameter setting mode, the LCD will show SET. Press the MODE button to select setting of C / F, ALM ON/OFF, ALM ALM and emissivity ε. Pull the trigger to exit setting mode and return to normal measurement mode. 2. Parameter settings: C / F : Temperature unit / F, press or to select units C or F. ALM (Alarm function ON/OFF): Press or to select alarm function on or off. ALM (Lo Alarm Function): Press or to set a value as an alarm value. When this Lo alarm value is exceeded, the beeper will sound and the ALM symbol will appear on the LCD. ALM (Hi Alarm Function): Press or to set up a value as an alarm value. When this Hi alarm value is exceeded, the beeper will sound and the ALM symbol will appear on the LCD. Example: To sound the alarm if the temperature exceeds 100 C or falls below 0 C, set the Hi Alarm point to100 C and the Lo Alarm point to 0 C. E-15
18 Setting procedure: a). Press and hold the MODE key for 3 seconds until the LCD displays the SET mark. b). Press button to select C unit. c). Press the MODE button once to enter ALARM ON/OFF setting mode, then press the or key to select ON mode. d). Press the MODE button once to enter ALARM (Lo Alarm point) setting mode. Press the or button until the display reads 0.0 C. e). Press the MODE button once to enter ALARM (Hi Alarm point) setting mode. Press the or button until the display reads100.0 C f). Pull the trigger to store the setting and exit the setting mode. ε (Emissivity): Press or to adjust the value. : Button for increasing the value. Hold down to increase the parameter value rapidly. : Button for decreasing the value. Hold down to decrease the parameter value rapidly. Note: After the setting procedure is terminated, the parameter will be stored until changed. Under setting mode, the backlight, laser, memory store and read functions are disabled. Pull the trigger to exit setting mode. E-16
19 BATTERY REPLACEMENT When the symbol + appears on the LCD screen, there is insufficient power in the battery to provide an accurate measurement. Replace the battery with a fresh one as follows: a) Ensure the instrument is turned off b) Open battery compartment cover on the rear of the grip. c) Remove the exhausted battery from the compartment. d) Fit a new battery of the type given in the specifications. e) Close the battery cover. f) Turn the instrument on and check for correct operation. OPEN E-17
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer
User Manual Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer MODEL 42515 Introduction Congratulations on your purchase of the Model 42515 IR Thermometer. The Model 42515 IR thermometer
Dual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42512 Introduction Congratulations on your purchase of the Model 42512 IR Thermometer. This Infrared thermometer measures and displays non-contact
OPERATION MANUAL INFRARED THERMOMETER
OPERATION MANUAL INFRARED THERMOMETER Features: Precise non-contact measurements Built-in laser pointer Automatic selection range and Resolution to 0.1ºor 1º / switchable button Automatic Data Hold & Auto
Dual Laser InfraRed (IR) Thermometer with Color Alert
User Manual Dual Laser InfraRed (IR) Thermometer with Color Alert MODEL 42509 Introduction Congratulations on your purchase of the Model 42509 IR Thermometer with Color Alert. This Infrared thermometer
Dual Laser InfraRed (IR) Thermometer
User s Manual Dual Laser InfraRed (IR) Thermometer MODEL 42511 Introduction Congratulations on your purchase of the Model 42511 IR Thermometer. This Infrared thermometer measures and displays non-contact
High Temperature InfraRed Thermometer with Laser Pointer
User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42540A 6 42540 6 Introduction Congratulations on your purchase of the Model 42540A IR Thermometer. The 42540A is capable of
Mini InfraRed Thermometer with Laser Pointer
User s Manual Mini InfraRed Thermometer with Laser Pointer MODEL 42500 Introduction Congratulations on your purchase of the Model 42500 IR Thermometer. This thermometer makes non-contact (infrared) temperature
RS DIGITAL THERMOMETER
RS DIGITAL THERMOMETER 1319A INSTRUCTION MANUAL C F MX MN AVG TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION... 1 2. SPECIFICATIONS... 1 3. NAME OF PARTS AND POSITIONS... 3 4. OPERATION INSTRUCTIONS... 5
Dual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42570 Introduction Congratulations on your purchase of the Model 42570 IR Thermometer. This Infrared thermometer measures and displays non-contact
EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER
EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER Users Manual - 1 - .Introduction Thank you for purchasing the SUPCO infrared (IR) thermometer and thermocouple meter. Please take a few minutes to browse
Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented
User's Guide Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your purchase of Extech's Laser Photo/Contact Tachometer with Non- Contact IR Thermometer,
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Handleiding Руководство пользователя
testo 835 Infrarot- und Kontaktthermometer Infrared and contact thermometer Thermomètre infrarouge et à contact Termómetro de contacto e infrarrojo Termometro a infrarossi e a contatto Infrarood- en contactthermometer
MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances
Operating Instructions MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances 15043 1/1.00 10 9 8 1 7 6 1 Display 2 Slider switch cd/m² segment test 3 ON/OFF switch 4
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
62 Max/62 Max + Infrared Thermometer
Infrared Thermometer Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measurement of the infrared energy radiated from the target
ULTRASONIC THICKNESS GAUGE TT100/110/120/130
ULTRASONIC THICKNESS GAUGE TT100/110/120/130 TT100 TT110 Portable size and easy operation Suitable for any metallic and non-metallic materials ultrasonic can go through Self-compensating of nonlinearity
Professional Thermohygrometer
User Manual Professional Thermohygrometer with NIST-Traceable Calibration Model 20250-21 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Professional Thermohygrometer (Model 20250-21)
USER GUIDE. LED Light Meter. Model LT45
USER GUIDE LED Light Meter Model LT45 Introduction Congratulations on your purchase of the Extech LT45 LED Light Meter that measures light from LED lamps in addition to fluorescent, metal halide, high
User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN
User's Guide Digital Psychrometer Model RH390 MAX MIN F C WBT Dew Point Introduction Congratulations on your purchase of the Extech RH390 Digital Psychrometer. This device measures Humidity, Air Temperature,
RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G
Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling
User s Guide. OS137 SERIES Miniature Non-Contact Infrared Temperature Sensor/Transmitter
MADE IN CAUTION! This product _ is not intended for medical use or use on humans User s Guide omega.com e-mail: [email protected] For latest product manuals: omegamanual.info OS137 SERIES Miniature Non-Contact
Ultrasonic Distance Meter. Operation Manual
XPROTEC Ultrasonic Distance Meter Operation Manual About XProTec Pro-Installer Tools The XProTec line from XFTP is a comprehensive lineup of professionalgrade technical tools. These full-featured, field-proven,
Ground Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
User's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
DSM155 Digital LED Light Meter User s Manual DSM155
DSM155 Digital LED Light Meter User s Manual DSM155 CONTENTS TABLE OF CONTENTS......3 LIMITED WARRANTY AND LIMITATION OF LIABILITY......3 Out of Box....3 Accessories....3 Safety Information....3 Certification....5
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
SOUND LEVEL METER 94405
SOUND LEVEL METER 94405 INSTRUCTION MANUAL REC FAST A/C 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
Integrating Sound Level Meter and Datalogger
USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,
How To Use A Meter
Table of Contents Title I UT391 Product Introduction II Unpacking Inspection III Safety Instruction IV Meter Structure V Setting and Operation of Meter VI Technical specifications VII Maintenance 3 4 5
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 ENG Instructions Thank you for purchasing a Canon product. Canon s TS-E lenses are tilt-shift lenses designed for EOS cameras. The tilt-shift mechanism enables
Model UT713 OPERATING MANUAL
Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC
Ground Resistance Clamp-On Tester
User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one
User's Manual. Model 461995 Laser Photo / Contact Tachometer. Introduction
User's Manual Model 461995 Laser Photo / Contact Tachometer Laser Photo/ Contact Tachometer 461995 MEMORY rpm PHOTO CONTACT ft/min m/min Introduction Congratulations on your purchase of Extech's Laser
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
UT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols
e 1 0 0 I N S T RUC TION M ANU A L
e 1 0 0 I N S T RUC TION M ANU A L The Empire Digital Level Accuracy, Readability, Durability one FEATURES: Easy to read back light Display reads right side up even if the level is upside down Audio beep
TABLE OF CONTENTS 11.0 WARRANTY
11.0 WARRANTY OI-1009.205L TABLE OF CONTENTS ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality
CL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
MANUAL TR-110 TR-110
MANUAL TR-110 TR-110 CONTENTS 1. GENERAL INTRODUCTION 2 2. WORK PRINCIPLE 3 3. STANDARD DELIVERY 4 4. NAME OF EACH PART 5 5. OPERATION 6 5.1 Preparation before operation 6 5.2 Switch on, Switch off and
User's Guide. Pinless Moisture Meter. Model MO257
User's Guide Pinless Moisture Meter Model MO257 Introduction Congratulations on your purchase of the Extech MO257 Pinless Moisture Meter. The pinless moisture sensor monitors the moisture in wood and other
Multi Media Cable Tester TM-901N/TM-902/TM-903
Multi Media Cable Tester TM-901N/TM-902/TM-903 User Manual HB2TM9020010 TENMARS ELECTRONICS CO., LTD Table of Contents 1 Introduction... 1 2 Safety Precaution... 1 3 The verifier does the following:...
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Model UT201/202: OPERATING MANUAL. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness
Thermocouple Thermometer Models
Technology Made Easy... Thermocouple Thermometer Models 60010-00 (Type J) 60010-10 (Type K) 60010-20 (Type T) 68X309905 Rev 1 04/04 TABLE OF CONTENTS 1. INTRODUCTION 4 2. SAFETY PRECAUTIONS 6 3. SPECIFICATIONS
Instant Ear Thermometer
INSTRUCTION MANUAL Instant Ear Thermometer Model 18-107-000 Please read this detailed guidebook completely before operating this unit. English Spanish Limited Five-Year Warranty Your Ear Thermometer is
User Guide. www.burntec.com. 4 wire Earth Resistance Tester Model GRT300
User Guide 4 wire Earth Resistance Tester Model GRT300 Introduction Congratulations on your purchase of Extech s 4 Wire Earth Resistance Tester. The Model GRT300 has been designed and tested according
digital fever alert ear thermometer suitable from birth instruction manual
digital fever alert ear thermometer suitable from birth instruction manual digital fever alert ear thermometer instruction manual Please read these instructions carefully before using the thermometer and
INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101
INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101 17 D GB F I E P NL AR A Dear customer, Thank you for your confi dence in Geratherm and congratulations on your purchase! By purchasing
Touchless Forehead Thermometer
Touchless Forehead Thermometer Model TFT-001 TM S A N 4LIF T E Contents Safety Precautions... 1 Sante4Life Touchless Forehead Thermometer... 2 Body Temperature... 3 Product Description... 5 Using the S4L
Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION
M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.
Metal Rescue Rust Remover Technical Data
Technical Data Product Description Metal Rescue TM is an innovative new technology that efficiently removes rust without harming surrounding materials. It is a water-based, non-toxic solution that is biodegradable
Thermistor Thermometer MODEL NO. 93210-00
Thermistor Thermometer MODEL NO. 93210-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail:
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
CO-220 Carbon Monoxide Meter
Page 1 CO-220 Carbon Monoxide Meter Instruction Sheet Introduction The CO-220 Carbon Monoxide Meter (hereafter referred to as the Meter ) detects the presence of carbon monoxide (CO) and measures concentrations
RT-1261A Ear and Forehead Thermometer Owner s Manual
RT-1261A Ear and Forehead Thermometer Owner s Manual 311-1261000-009 Version 1.0 April, 2009 IMPORTANT SAFETY INSTRUCTIONS nu-beca RT-1261A Ear and Forehead Thermometer READ THIS BEFORE USING The following
Leica DISTO TM D210 The original laser distance meter
Leica DISTO TM D0 The original laser distance meter Table of Contents Instrument Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - Overview - - - - - - - - - - - - - - - - - - - - - - - - - -
DC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 82IP-303A0ME E1 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
Guideline Laser Series
Guideline Laser Series Highly visible alignment laser for visually demanding surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS
Available Options The IR-750B, IR-750EXB, IR-16 and IR-16EX series heat tracers are available with the options listed below.
Infrared Heat Tracers The Scotchtrak Infrared Heat Tracer is a rugged, highly accurate, and easy-to-use portable non-contact (infrared) thermometer. It is an invaluable tool for monitoring operating temperatures
Instruction Manual Temp 4/5/6 Temperature Meter Series
Instruction Manual Temp 4/5/6 Temperature Meter Series 68X243607 Technology Made Easy... Rev. 2 01/03-1 - Preface This instruction manual serves to explain the use of the Temp 4/5/6 temperature meter.
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Purchasing Thermometers
L E S S O N 2 Purchasing Thermometers Lesson Objectives Getting Ready 1. Determine thermometer needs for each school kitchen or food production facility. 2. Develop and use specifications to purchase and
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
ACL 395 Resistivity Meter
ACL 395 Resistivity Meter OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every 12 months. 840 W. 49 th Place Page 1 of 13 [email protected]
Long Distance Industrial Wireless Transmitters and Receivers
Long Distance Industrial Wireless s and Receivers Up to 450 m (1500') Line of Sight Range UWXL Series U Thermocouple, RTD, Temperature, RH, ph, Process Voltage/ Current and Input Models U J, K, T, E, R,
Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)
(Part # S-LIB-M003) The smart sensor is designed to work with the HOBO Weather Station logger. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Weather Station.
RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.
Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of
Laser Distance Meter Laser-Distanzmesser Laser distance-mètre Metro di distanza laser Medidor Láser de Distancia User Manual
Laser Distance Meter Laser-Distanzmesser Laser distance-mètre Metro di distanza laser Medidor Láser de Distancia User Manual PPl lleeaassee read this manual before switching the unit on. Important safety
Laserlyte-Flex Alignment System
Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning
Day / Night IR Color Camera User Manual V2.1.0
Day / Night IR Color Camera User Manual V2.1.0 1 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-2CC102P(N)-IR1(IR3)(IR5),
Temperature Humidity Meter
971 Temperature Humidity Meter Users Manual PN 2441047 September 2005 Rev.1, 5/06 2005-2006 Fluke Corporation, All rights reserved. Printed in Taiwan All product names are trademarks of their respective
Magnetic Deburring & Polishing Machine
Magnetic Deburring & Polishing Machine Operation Manual Models: EHD-750CL, 766, 735, 728, 716, 715 1 Index 1. Before Starting to Use the spinner 2. Functions 3. Features 4. Applications 5. Principle of
Tympanic Thermometer
Tympanic Thermometer Tympanic Thermometer Owner s Manual Version 1.0 May, 2013 IMPORTANT SAFETY INSTRUCTIONS READ THIS BEFORE USING The following basic safety precautions should always be taken. 1. Close
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
Digital Photo Picture Frame. Operation Manual
Digital Photo Picture Frame Operation Manual 20070309 CONGRATULATIONS on your purchase of a Polaroid 7 LCD Digital Photo Picture Frame. Please read carefully and follow all warnings and instructions in
Technical Data FLIR E40bx (incl. Wi-Fi)
Technical Data FLIR E40bx (incl. Wi-Fi) Part number: 64501-0501 Copyright 2013, FLIR Systems, Inc. All rights reserved worldwide. Names and marks appearing herein are either registered trademarks or trademarks
Portable Hardness Tester
Portable Hardness Tester Large, easy to read display with backlight Highly accurate ± 4 HL Automatic correction for impact direction Converts to all common hardness scales (,,,, HS, R m ) Light weight
Instant Ear Thermometer
INSTRUCTION MANUAL Instant Ear Thermometer Model 18-102-000 Please read this detailed guidebook completely before operating this unit. English French Portuguese Spanish Limited Five-Year Warranty Your
Operations Manual Blast Chiller
Operations Manual Blast Chiller ADE- 2039-A Page 1 of 14 Contents Page 1 What is the Adande System 3 2 Adande Technology Explained 3 3 EC Declaration of Conformity 4 4 Storage of Product 5 5 Operating
XFA 600 Thermal Diffusivity Thermal Conductivity
XFA 600 Thermal Diffusivity Thermal Conductivity Thermal Diffusivity, Thermal Conductivity Information of the thermo physical properties of materials and heat transfer optimization of final products is
1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
1.50mm Height 2220 Package Top View Full Color Chip LEDs Technical Data Sheet. Part No.: LL-R5050RGBC-001
.5mm Height 222 Package Top View Full Color Chip LEDs Technical Data Sheet Part No.: LL-R55RGBC- Spec No.: R55 Rev No.: V.2 Date: Mar./6/26 Page: OF 2 Features: P-LCC-6 package. White package. Optical
WSD130 SOLDERING STATION
NOTES S2032ACH 8/98 Rev. 11/01 WSD130 SOLDERING STATION 1. Power Switch 2. Digital Display 3. UP Button 4. DOWN Button 5. Optical Regulator, Right 6. Connection for Soldering Iron, Right 7. Selection Switch
Model UT33A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation
Infrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions
Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions WARNING: READ ALL INSTRUCTIONS AND THE ENCLOSED SAFETY PRECAUTIONS BEFORE ASSEMBLY AND USE Assemble and use these parts ONLY
