Flygt 3068, 50Hz. Technical Specification



Similar documents
Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

Welcome to Grindex Pump handbook! With this handbook we want to share some of our wide experience in pumping with submersible pumps.

Series description: Wilo-Drain TC 40

No: En Revision Parts List. MINEX

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

Flygt 2700 series. Corrosion resistant dewatering pumps. 60 Hz

Pure Performance. Steady 1300 Series

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Flygt N-pump series SelF-cleaNiNg pumps with SuStaiNed high efficiency

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

4" SUBMERSIBLE PUMPS

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

CRK A-W-A-BUBV

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

How To Pump A Pump

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Godwin NC series Dri-Prime pumps

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

ROBOT PUMPS RT - TURBOTEX PUMPS

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

Project: Model: Chk d: Date: Model 32DGUII61.5S

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Tsurumi BER. Submersible Ejectors

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

SJT / SJM / SJP Large Vertical Pumps

SEG range kw GRUNDFOS WASTEWATER

The conditions below apply to the curves shown on the following pages.

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

Pumps SELECTION OF A PUMP

Horizontal Jet Pumps 1/3-1-1/2 HP

Conlift1, Conlift2, Conlift2 ph+

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

SIGMA GROUP a. s. Divize průmyslová čerpadla

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Vogel - Multistage Pumps Design MP, MPA, MPB, MPV Sizes DN 40 - DN 125

BS Small Dewatering Pump - Stainless Steel Capacity up to 260 GPM, Heads up to 85 ft. Specifications

SUBM Electrical Submersible Pumps and Motors

WATER & WASTEWATER. Flygt Submersible Pumps

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Vertical Pumps for the Oil & Gas Industry

Standard offering (pumps)

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Flygt Ball Check Valves

Multistage high-pressure multistage centrifugal pumps

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

3/2-way Solenoid Valve, direct-acting, NC or NO

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Dry Pit Solids Handling Pumps

Solar Hot Water Heaters

BASIS RANGE TMB SERIES

LC/LCD ranges level controllers

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Submersible Motor Pump. Amarex N. 50 Hz DN 50 - DN 100. Type Series Booklet

Hydraulic Control Solutions

General Information. Applications

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Vertical selfpriming Side-Channel Pumps Type WPV

VERTICAL TURBINE AND PROPELLER PUMPS

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Series description: Wilo-Yonos MAXO

Vacuum drying oven for non-flammable solvents

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. Water supply. Sprinkler irrigation. Pressure boosting. Fire-fighting.

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Tube Type Oil Skimmer Comparison

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

MODEL INSTALLATION INSTRUCTIONS

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

James M. Pleasants Company

Transformer oil cooler ALFA A02

Roller Chain Coupling

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

Series 8146/5-V37 and Series 8150/5-V37

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

OPERATION & MAINTENANCE MANUAL SUBMERSIBLE SEWAGE PUMP

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

RUBBER SLEEVE KNIFE GATE VALVE

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC. Cod.

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

P.E.D. 97/23/EC/0424 Butterfly Valves Series SL, SLK Group 1-2 Class I, II, III ATEX CE Ex II 2 GD

SanStar Series SSi and SSO Mixers SANITARY MIXERS

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

GENIX AUTOMATIC LIFTING STATIONS

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Transcription:

Flygt 3068, 50Hz Technical Specification

Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating and performance curves...9 D-pump...10 Product description...10 Motor rating and performance curves 3068.180/.090...12 Motor rating and performance curves 3068.250/.590...15 F-pump...17 Product description...17 Motor rating and performance curves...19 M-pump...21 Product description 3068.170/.890...21 Product description 3068.175...23 Motor rating and performance curves 3068.170/.890...25 Motor rating and performance curves 3068.175...26 Dimensions and Weight...28 Drawings, B-pump...28 Drawings, C-pump...28 Drawings, D-pump...30 Drawings, F-pump...34 Drawings, M-pump 3068.170...35 Drawings, M-pump 3068.175...36 Flygt 3068, 50Hz Technical Specification 1

B-pump B-pump Product description Usage Denomination Submersible pump for dewatering of construction sites, flood cleaning operations and other similar applications. Type Non explosion proof version Explosion proof version Pressure class Standard 3068.250 3068.590 HT High head P, S The pump can be used in the following installations: Installation types P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. S Portable semi permanent, wet well arrangement with hose coupling or flange for connection to discharge pipeline. Application Limits Feature Liquid temperature Liquid temperature, warm water version Depth of immersion Description Maximum 40 C, (104 F) Maximum 70 C, (158 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 15 Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Insulation class Maximum 2% F (+155 C) 2 Flygt 3068, 50Hz Technical Specification

B-pump Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable 4G2.5 mm 2 4G1.5+2 1.5 mm 2 7G2.5 mm 2 Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 30B GJL-200 Pump housing Cast iron, gray 35B GJL-250 Impeller, alternative 1 Steel, quenched and tempered Impeller, alternative 2 Stainless steel A 743 CF-8 1,4308 Lifting handle Stainless steel AISI 304 1,4301 Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A2 AISI 304 1.4301, 1.4306, 1.4307, 1.4311 O-rings, alternative 1 Nitrile rubber (NBR) 70 IRH O-rings, alternative 2 Oil, part no 901752 Table 1: Mechanical face seals Fluorinated rubber (FPM) 70 IRH Medical white oil of paraffin type. Fulfills FDA 172.878 (a) Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Aluminum oxide/ Corrosion resistant 2 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant 3 Corrosion resistant cemented carbide/ Corrosion resistant 4 Corrosion resistant cemented carbide/ Corrosion resistant Corrosion resistant cemented carbide/ Corrosion resistant Silicon carbide/ Silicon carbide 5 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide Flygt 3068, 50Hz Technical Specification 3

B-pump Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. Options Accessories Warm liquid version (non-explosion proof versions) Leakage sensor in the stator housing (FLS) Surface treatment (Epoxy) Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves Star-delta starting current is 1/3 of Direct on-line starting current. 4 Flygt 3068, 50Hz Technical Specification

B-pump HT P 2 [kw] 1.6 1.2 0.8 253 251 251 18 16 14 12 10 8 6 4 H [m] HT 2 0 251 253 251 0 1 2 3 4 5 6 7 8 9 Q [l/s] WS005193A Table 2: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.7 2.3 251 2695 3.8 17.87 P,S 1.7 2.3 253 2695 3.8 17.87 P,S Installation Flygt 3068, 50Hz Technical Specification 5

C-pump C-pump Product description Usage Denomination Submersible pump for pumping clean water, surface water and waste water containing solids or fibred material. Type Non explosion proof version Explosion proof version Pressure class Standard 3068.180 3068.090 HT High head F, P, S The pump can be used in the following installations: Installation types F Free standing semi permanent, wet well arrangement where the pump is placed on a firm surface. P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. S Portable semi permanent, wet well arrangement with hose coupling or flange for connection to discharge pipeline. Application Limits Feature Liquid temperature Liquid temperature, warm water version Depth of immersion Description Maximum 40 C, (104 F) Maximum 70 C, (158 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 15 Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% 6 Flygt 3068, 50Hz Technical Specification

C-pump Feature Voltage imbalance between phases Insulation class Description Maximum 2% F (+155 C) Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable Screened SUBCAB heavy-duty submersible cable 4G1.5 mm 2 4G2.5 mm 2 4G1.5+2 1.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 S3 2.5+3 2.5/3+4 1.5 mm 2 Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 35B GJL-250 Pump housing Cast iron, gray 30B GJL-200 Impeller Cast iron, gray 35B GJL-250 Wear ring Bronze C924 CC491K, CC492K Lifting handle Stainless steel AISI 304 1,4301 Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A2 AISI 304 1.4301, 1.4306, 1.4307, 1.4311 O-rings, alternative 1 Nitrile rubber (NBR) 70 IRH O-rings, alternative 2 Oil, part no 901752 Table 3: Mechanical face seals Fluorinated rubber (FPM) 70 IRH Medical white oil of paraffin type. Fulfills FDA 172.878 (a) Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Aluminum oxide/ Corrosion resistant 2 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant 3 Corrosion resistant cemented carbide/ Corrosion resistant Corrosion resistant cemented carbide/ Corrosion resistant Flygt 3068, 50Hz Technical Specification 7

C-pump Alternative Inner seal Outer seal 4 Corrosion resistant cemented carbide/ Corrosion resistant Silicon carbide/ Silicon carbide 5 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. Options Accessories Warm liquid version (non-explosion proof versions) Leakage sensor in the stator housing (FLS) Surface treatment (Epoxy) Zinc anodes Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. 8 Flygt 3068, 50Hz Technical Specification

C-pump Motor rating and performance curves HT P 2 [kw] 2.5 2.0 1.5 1.0 0.5 0.0 25 H [m] 255 253 251 HT 20 15 10 5 255 253 251 0 0 2 4 6 8 10 12 14 16 Q [l/s] WS005196A Table 4: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.7 2.3 253 2695 3.8 17.87 F,P,S 1.7 2.3 255 2695 3.8 17.87 F,P,S 2.4 3.2 251 2775 5.1 27.86 F,P,S 2.4 3.2 253 2775 5.1 27.86 F,P,S 2.4 3.2 255 2775 5.1 27.86 F,P,S Table 5: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.5 2 253 2695 9.4 27 1 F,P,S 1.5 2 255 2695 9.4 27 1 F,P,S Installation Installation Flygt 3068, 50Hz Technical Specification 9

D-pump D-pump Product description Usage 3068.180/.090 Usage 3068.250/.590 Submersible pump for pumping clean water, surface water and waste water containing solids or fibred material. Submersible pump for dewatering of construction sites, flood cleaning operations and other similar applications. Denomination Type Non explosion proof version Explosion proof version Pressure class Installation types Standard 3068.180 3068.090 MT Medium head HT High head F, P, S 3068.250 3068.590 LT Low head P, S The pump can be used in the following installations: F Free standing semi permanent, wet well arrangement where the pump is placed on a firm surface. P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. S Portable semi permanent, wet well arrangement with hose coupling or flange for connection to discharge pipeline. Application Limits Feature Liquid temperature Liquid temperature, warm water version Depth of immersion Description Maximum 40 C, (104 F) Maximum 70 C, (158 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 15 10 Flygt 3068, 50Hz Technical Specification

D-pump Feature Description Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Insulation class Maximum 2% F (+155 C) Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable NSSHÖU../3E+St 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 3x2.5+3x2.5/3E+3x1.5 St Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 35B GJL-250 Pump housing, alternative 1 Pump housing, alternative 2 Cast iron, gray 30B GJL-200 Cast iron, gray 35B GJL-250 Impeller, alternative 1 Cast iron, gray 35B GJL-250 Impeller, alternative 2 Cast iron, gray 30B GJL-200 Impeller, alternative 3 Cast iron, Hard-Iron A 532 IIIA GJN-HB555(XCR23) Impeller, alternative 4 Cast iron, Hard-Iron A 532 IIIA GJN-HB555(XCR23) Lifting handle Stainless steel AISI 304 1,4301 Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A2 AISI 304 1.4301, 1.4306, 1.4307, 1.4311 O-rings, alternative 1 Nitrile rubber (NBR) 70 IRH O-rings, alternative 2 Fluorinated rubber (FPM) 70 IRH Flygt 3068, 50Hz Technical Specification 11

D-pump Denomination Material ASTM EN Oil, part no 901752 Medical white oil of paraffin type. Fulfills FDA 172.878 (a) Table 6: Mechanical face seals Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Aluminum oxide/ Corrosion resistant 2 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant 3 Corrosion resistant cemented carbide/ Corrosion resistant 4 Corrosion resistant cemented carbide/ Corrosion resistant Corrosion resistant cemented carbide/ Corrosion resistant Silicon carbide/ Silicon carbide 5 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. Options Accessories Warm liquid version (non-explosion proof versions) Leakage sensor in the stator housing (FLS) Surface treatment (Epoxy) Zinc anodes Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves 3068.180/.090 Star-delta starting current is 1/3 of Direct on-line starting current. 12 Flygt 3068, 50Hz Technical Specification

D-pump MT P 2 [kw] P 2 [kw] 2.5 2.5 2.0 470 2.0 470 1.5 1.0 0.5 474 473 472 471 1.5 1.0 0.5 473 472 471 0.0 10 H [m] MT 3~ 65 mm 0.0 9 8 H [m] MT 3~ 80 mm 8 7 6 6 5 4 2 474 473 472 471 470 4 3 2 1 473 472 471 470 0 0 2 4 6 8 10 12 14 16 Q [l/s] 0 0 4 8 12 16 20 Q [l/s] WS005186A WS005187A Table 7: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.5 2 471 1370 4.4 16.76 F,P,S 1.5 2 472 1370 4.4 16.76 F,P,S 1.5 2 473 1370 4.4 16.76 F,P,S 1.5 2 474 1370 4.4 16.76 F,P,S 2 2.7 470 1360 5.0 20.83 F,P,S 2 2.7 471 1360 5.0 20.83 F,P,S 2 2.7 472 1360 5.0 20.83 F,P,S 2 2.7 473 1360 5.0 20.83 F,P,S 2 2.7 474 1360 5.0 20.83 F,P,S Installation Flygt 3068, 50Hz Technical Specification 13

D-pump P 2 [kw] 1.6 1.2 0.8 0.4 472 (65 mm) 473 (65 mm) 473 (80 mm) 472 (80 mm) 0.0 H [m] 6 MT 1~ 5 472 (65 mm) 4 3 2 473 (65 mm) 473 (80 mm) 472 (80 mm) 1 0 0 2 4 6 8 10 12 14 Q [l/s] WS005188A Table 8: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.3 1.7 472 1400 8.4 28 1 F,P,S 1.3 1.7 473 1400 8.4 28 1 F,P,S Installation 14 Flygt 3068, 50Hz Technical Specification

D-pump HT P 2 [kw] P 2 [kw] 3.0 2.5 2.0 1.5 210 214 (55 mm) 214 (65 mm) 220 (1.7 kw) 220 (2.4 kw) 2.0 1.8 1.6 1.4 1.2 1.0 220 (65 mm) 220 (55 mm) H [m] H [m] 20 HT 3~ 10 220 (55 mm) HT 1~ 16 210 8 12 214 (55 mm) 6 220 (65 mm) 214 (65 mm) 8 220 (1.7 kw) 4 4 220 (2.4 kw) 2 0 0 2 4 6 8 10 12 Q [l/s] 0 0 1 2 3 4 5 Q [l/s] WS005189A WS005190A Table 9: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.7 2.3 220 2695 3.8 17.87 F,P,S 2.4 3.2 210 2775 5.1 27.86 F,P,S 2.4 3.2 214 2775 5.1 27.86 F,P,S 2.4 3.2 220 2775 5.1 27.86 F,P,S Table 10: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.5 2.0 220 2760 8.7 30 0.98 F,P,S Installation Installation Motor rating and performance curves 3068.250/.590 Star-delta starting current is 1/3 of Direct on-line starting current. Flygt 3068, 50Hz Technical Specification 15

D-pump LT P 2 [kw] 1.4 1.2 1.0 0.8 0.6 281 (1.7 kw) 281 (1.5 kw) 283 (1.7 kw) 283 (1.5 kw) H [m] 14 LT 12 10 8 6 4 2 283 (1.5 kw) 281 (1.7 kw) 281 (1.5 kw) 283 (1.7 kw) 0 0 1 2 3 4 5 Q [l/s] WS005192A Table 11: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.7 2.3 281 2700 3.8 17.87 P, S 1.7 2.3 283 2700 3.8 17.87 P, S Table 12: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.5 2 281 2730 8.9 28.99 P, S 1.5 2 283 2730 8.9 28.99 P, S Installation Installation 16 Flygt 3068, 50Hz Technical Specification

F-pump F-pump Product description Usage Denomination Submersible pump for pumping liquid manure, or heavily contaminated sewage and sludge. The impeller is S-shaped and fitted with a cutting device. Type Non explosion proof version Explosion proof version Pressure class Standard 3068.180 3068.090 LT Low head P, S The pump can be used in the following installations: Installation types P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. S Portable semi permanent, wet well arrangement with hose coupling or flange for connection to discharge pipeline. Application Limits Feature Liquid temperature Liquid temperature, warm water version Depth of immersion Description Maximum 40 C, (104 F) Maximum 70 C, (158 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 3-phase Direct on-line Star-delta Number of starts per hour Maximum 15 Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Insulation class Maximum 2% F (+155 C) Flygt 3068, 50Hz Technical Specification 17

F-pump Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable NSSHÖU../3E+St 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 3x2.5+3x2.5/3E+3x1.5 St Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 30B GJL-200 Pump housing Cast iron, gray 35B GJL-250 Impeller Cast iron, Hard-Iron A 532 IIIA GJN-HB555(XCR23) Suction cover Cast iron, gray 30B GJL-200 Lifting handle Stainless steel AISI 304 1,4301 Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A2 AISI 304 1.4301, 1.4306, 1.4307, 1.4311 O-rings, alternative 1 Nitrile rubber (NBR) 70 IRH O-rings, alternative 2 Oil, part no 901752 Fluorinated rubber (FPM) 70 IRH Table 13: Mechanical face seals Medical white oil of paraffin type. Fulfills FDA 172.878 (a) Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Aluminum oxide/ Corrosion resistant 2 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant 3 Corrosion resistant cemented carbide/ Corrosion resistant 4 Corrosion resistant cemented carbide/ Corrosion resistant Corrosion resistant cemented carbide/ Corrosion resistant Silicon carbide/ Silicon carbide 5 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide 18 Flygt 3068, 50Hz Technical Specification

F-pump Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. Options Accessories Warm liquid version (non-explosion proof versions) Leakage sensor in the stator housing (FLS) Surface treatment (Epoxy) Zinc anodes Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves Star-delta starting current is 1/3 of Direct on-line starting current. Flygt 3068, 50Hz Technical Specification 19

F-pump LT WS005200A Table 14: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.7 2.3 290 2695 3.8 17.87 S 1.7 2.3 291 2695 3.8 17.87 P 2.4 3.2 290 2775 5.1 27.86 S 2.4 3.2 291 2775 5.1 27.86 P Installation 20 Flygt 3068, 50Hz Technical Specification

M-pump M-pump Product description 3068.170/.890 Usage Denomination Submersible pump for pumping waste water containing solids that need to be macerated. The impeller is equipped with a grinder device. Type Non explosion proof version Explosion proof version Pressure class Standard 3068.170 3068.890 HT High head F, P The pump can be used in the following installations: Installation types F Free standing semi permanent, wet well arrangement where the pump is placed on a firm surface. P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. Application Limits Feature Liquid temperature Liquid temperature, warm water version Depth of immersion Description Maximum 40 C, (104 F) Maximum 70 C, (158 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 15 Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Insulation class Maximum 2% F (+155 C) Flygt 3068, 50Hz Technical Specification 21

M-pump Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable 4G1.5 mm 2 4G1.5+2 1.5 mm 2 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings, alternative 1 Major castings, alternative 2 Cast iron, gray 30B GJL-200 Cast iron, gray 35B GJL-250 Pump housing Cast iron, gray 30B GJL-200 Impeller Cast iron, gray 30B GJL-200 Suction cover Cast iron, gray 30B GJL-200 Cutter wheel Cast iron, Hard-Iron A 532 IIIA GJN-HB555(XCR23) Cutter plate Stainless steel Lifting handle Stainless steel AISI 304 1,4301 Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A2 AISI 304 1.4301, 1.4306, 1.4307, 1.4311 O-rings, alternative 1 Nitrile rubber (NBR) 70 IRH O-rings, alternative 2 Oil, part no 901752 Fluorinated rubber (FPM) 70 IRH Table 15: Mechanical face seals Medical white oil of paraffin type. Fulfills FDA 172.878 (a) Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Aluminum oxide/ Corrosion resistant 2 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. 22 Flygt 3068, 50Hz Technical Specification

M-pump Options Accessories Leakage sensor in the stator housing (FLS) Surface treatment (Epoxy) Zinc anodes Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Product description 3068.175 Usage Denomination Submersible pump for pumping waste water containing solids that need to be macerated. The impeller is equipped with a grinder device. Type Non explosion proof version Explosion proof version Pressure class Installation types Standard 3068.175 HT High head F, H The pump can be used in the following installations: F Free standing semi permanent, wet well arrangement where the pump is placed on a firm surface. H Semi permanent, wet well quick connection suspended arrangement, incorporating integral non-return valve. Application Limits Feature Liquid temperature Depth of immersion Description Maximum 40 C, (104 F) Maximum 20 m (65 ft) ph of the pumped liquid 6 11 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 15 Code compliance IEC 60034-1 Rated output variation ±10% Flygt 3068, 50Hz Technical Specification 23

M-pump Feature Description Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Insulation class Maximum 2% F (+155 C) Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable 4G1.5 mm 2 4G1.5+2 1.5 mm 2 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material AISI/ASTM EN Stator housing Cast iron, gray 35B GJL-250 Pump housing Cast iron, gray ASTM A 48 NO 30B 1561:1997-GJL-200 Rubber stator Nitrile rubber (NBR) 75 IRH Spiral rotor Stainless steel AISI 304 1.4301 and 1.4541 Shaft Stainless steel AISI 431 1.4057+QT800 Studs, screws & nuts Stainless steel, A2 AISI 304 1.4301 and 1.4541 O-rings Nitrile rubber (NBR) 70 IRH Table 16: Mechanical face seals Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Aluminum oxide/ Corrosion resistant 2 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. 24 Flygt 3068, 50Hz Technical Specification

M-pump Options Accessories Leakage sensor in the stator housing (FLS) Surface treatment (Epoxy) Zinc anodes Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves 3068.170/.890 HT Star-delta starting current is 1/3 of Direct on-line starting current. P 2 [kw] P 2 [kw] 2.5 2.0 1.5 1.0 214 210 212 (2.4 kw) 212 (1.7 kw) 216 (2.4 kw) 216 (1.7 kw) 1.8 1.6 1.4 1.2 1.0 0.8 218 214 30 H [m] HT 3~ 20 H [m] HT 1~ 25 16 20 12 15 10 210 212 (2.4 kw) 212 (1.7 kw) 8 5 214 216 (2.4 kw) 216 (1.7 kw) 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s] WS005202A 4 218 214 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s] WS005203A Table 17: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.7 2.3 212 2695 3.8 17.87 F,P 1.7 2.3 214 2695 3.8 17.87 F,P 1.7 2.3 216 2695 3.8 17.87 F,P 2.4 3.2 210 2700 5.3 24.87 F,P 2.4 3.2 212 2700 5.3 24.87 F,P Installation Flygt 3068, 50Hz Technical Specification 25

M-pump kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 2.4 3.2 214 2700 5.3 24.87 F,P 2.4 3.2 216 2700 5.3 24.87 F,P Table 18: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.5 2 214 2695 9.4 31 1 F, P 1.5 2 218 2695 9.4 31 1 F, P Installation Installation Motor rating and performance curves 3068.175 Star-delta starting current is 1/3 of Direct on-line starting current. 26 Flygt 3068, 50Hz Technical Specification

M-pump HT P 2 [kw] 1.2 0.8 0.4 0.0 60 H [m] HT 450 (1~) 450 (3~) 50 40 30 20 450 (1~) 450 (3~) 10 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Q [l/s] WS005206A Table 19: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ.9 1.2 450 1430 3.5 16.58 F,H Table 20: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ.9 1.2 450 1435 6.1 26 1 F,H Installation Installation Flygt 3068, 50Hz Technical Specification 27

Dimensions and Weight Dimensions and Weight Drawings, B-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. Figure 1: HT, P-installation Figure 2: HT, S-installation Drawings, C-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. 28 Flygt 3068, 50Hz Technical Specification

Dimensions and Weight Figure 3: HT, F-installation Figure 4: HT, P-installation Figure 5: HT, P-installation Figure 6: HT, P-installation Flygt 3068, 50Hz Technical Specification 29

Dimensions and Weight Figure 7: HT, S-installation Drawings, D-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. Figure 8: LT, P-installation Figure 9: LT, S-installation 30 Flygt 3068, 50Hz Technical Specification

Dimensions and Weight Figure 10: MT, F-installation Figure 11: MT, F-installation Figure 12: MT, F-installation Figure 13: MT, P-installation Flygt 3068, 50Hz Technical Specification 31

Dimensions and Weight Figure 14: MT, P-installation Figure 15: MT/HT, P-installation Figure 16: MT, S-installation Figure 17: MT, S-installation 32 Flygt 3068, 50Hz Technical Specification

Dimensions and Weight Figure 18: MT, S-installation Figure 19: MT, S-installation Figure 20: HT, F-installation Figure 21: HT, F-installation Flygt 3068, 50Hz Technical Specification 33

Dimensions and Weight Figure 22: HT, P-installation Figure 23: HT, S-installation Figure 24: HT, S-installation Drawings, F-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. 34 Flygt 3068, 50Hz Technical Specification

Dimensions and Weight Figure 25: LT, P-installation Figure 26: LT, S-installation Drawings, M-pump 3068.170 All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. Figure 27: HT, F-installation Figure 28: HT, F-installation Flygt 3068, 50Hz Technical Specification 35

Dimensions and Weight Figure 29: HT, P-installation Drawings, M-pump 3068.175 All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. Figure 30: HT, F-installation 36 Flygt 3068, 50Hz Technical Specification

Xylem zīləm 1) The tissue in plants that brings water upward from the roots 2) A leading global water technology company We're 12,500 people unified in a common purpose: creating innovative solutions to meet our world's water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com Xylem Water Solutions AB Gesällvägen 33 174 87 Sundbyberg Sweden Tel. +46-8-475 60 00 Fax +46-8-475 69 00 http://tpi.xyleminc.com Visit our Web site for the latest version of this document and more information The original instruction is in English. All non- English instructions are translations of the original instruction. 2012 Xylem Inc. 883447_1.0_en.US_2012-07_TS_3068_50Hz