Power transformers. Special transformers Railway



Similar documents
Transformers. Special transformers Reactors products

Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

Unified requirements for systems with voltages above 1 kv up to 15 kv

INTERNATIONAL STANDARD

Three-phase monitoring relay CM-PFE

Presentation of the France Transfo factories

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Electronic overload relay EF19 and EF45

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

Electronic overload relay EF65, EF96 and EF146

Voltage Regulator SPAU 341 C. Product Guide

Power transformers. Phase shifting transformers Reliable and efficient power flow control

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Together we create reliable products, thus ensuring development of power industry of continents.

DISCONNECTORS AND LOAD SWITCHES for railways

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Estimation of electrical losses in Network Rail Electrification Systems

Brochure. Electric generators to power the world

Current and voltage measuring relays

Analog signal converters CC-E I/I Current / current isolators

Cable Solutions for Servo and Variable Frequency Drives (VFD)

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility

High Performance Railway Power

Transformer Design & Design Parameters

reduction ore = metal oxides metal oxidation

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

INTERNATIONAL STANDARD

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Connection of micro-generation to the electricity distribution network

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Speed sensor MiniCoder GEL 247

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Agilent 87421A/87422A Power Supply

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Type: DILM9 10(24VDC) Article No.:

-Liquid-cooled frequency converter switchgear

INTERNATIONAL STANDARD

How To Understand The Electrical Power Supply Of A Power Supply System

Service Power Technologies. Retrofitting A future-oriented concept in lifecycle management

SURGE PROTECTIVE DEVICES

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Pilot-wire differential relay for lines with two or more terminals

Knowing the FACTS. FACTS that enhance power quality in rail feeder systems

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Distribution transformers. Green distribution transformer program Partnership for a sustainable environment

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Step Voltage Regulators

Low Voltage Products. Switches Automatic Transfer Switches

Product Data Bulletin

3753 en /b VE/B - VE/RG Va V riable speed drives

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Thermistor motor protection

Medium-voltage Transformers

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva

Waveguide Access Point WGA631. Product Guide

Power Supplies in Medical Electronics


AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Technical Information Requirement for MV transformers and transformer for internal power supplies for SUNNY CENTRAL

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

TOPOLOGIES FOR SWITCHED MODE POWER SUPPLIES

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Table of Contents. TransformerIQ FAQs 1

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Distribution Voltage Regulators

Inverter technology. bulletin

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Transcription:

Power transformers Special transformers Railway

A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together with the clients, ensuring that the requirements of a special pre-qualification process, railway profile requirements and the extreme overload requirements according to EN50239 are always met. The high quality of our reliable products provides an outstanding capacity to withstand short circuits, which are common in electric railways. Special type tests and quality control ensure safe operation, while ABB s product support and service network guarantee free-and-easy use of the products. Special insulating liquids, Midel can be used for improved environmental safety and reduced fire risk. The railway transformers are also protected against vandalism. Railway systems and equipment used in the world are often bound by local national requirements and building practices. Therefore, the components must be specially designed and type-tested for each railway for an optimal solution. ABB offers its expertise and experience for the railroad builders worldwide for finding the best solutions with ABB equipment. Railway transformers manufactured by ABB: Autotransformers Booster transformers AC traction feeder transformers DC traction feeder transformers Traction static converter transformers Auxiliary transformers Isolation transformers Standards The following standards govern the railway transformers and their application field: IEC 60076, transformer standard EN 50329, EU standard for railway fixed installation transformers EN 50121-5, EU standard for EMC (Electro Magnetic Compatibility) for railway applications EN 50122-1, EU standard for earthing safety regulations for railway applications EN 50124-1, insulation coordination for railway applications Testing Extensive and heavy type testing programs have been performed for each design of the transformers to fulfill the special requirements of the railway companies. References ABB has supplied railway transformers to the following countries: Finland Israel Sweden Algeria Norway Maleysia Denmark India Germany China Belgium Switzerland UK Austria Italy Zimbabwe Mexico HongKong USA Spain Turkey South Africa 2 Railway transformers Special transformers

Catenary autotransformers The electric energy for railways is supplied in high voltage to catenary feeder substations, where the voltage is reduced to a suitable level and fed to the railway catenary conductors to be used by locomotives and trains. Catenary autotransformers are used in modern high-power railway catenary systems fed with two phases with a 180 phase shift, with the mid-point connected to the earth. They are applied to all new high-speed train systems. Purpose In railways, the electric current is taken from the catenary conductor to the locomotive, where the energy is used by electric motors and fed to the earth connected rails, which are part of the return circuit. In a two-phase fed catenary system, the rail and the earthed return conductor are connected to the mid point of the catenary autotransformer. One pole of the autotransformer is connected to the catenary phase, and the other pole to the negative phase conductor. With this connection, the power is fed to the locomotive with double voltage compared to the voltage of the locomotive itself. This means that the phase currents are reduced to half and the feeder losses to the fourth part compared to the single-phase feeder. The task of the autotransformers along the catenary line is to balance the voltages between the catenary and the earth, and the negative phase conductor and the earth, and then distribute the return current evenly between the two phases. The advantages that are obtained with this connection compared with single-phase feeding and booster transformers are among the following, depending on the objectives: Lower losses due to higher voltage Longer distance between catenary feeder substations Better collection of returning stray currents Reduced interference for communications Catenary autotransformers are basically single-phase autoconnected transformers. The primary winding is connected between the two phases and the secondary winding between the catenary phase and the earthed return conductor. The secondary voltage is the catenary voltage against earth, and the primary voltage is two times that. The requirements for transformers used in electric railways are demanding and special. The impedances of autotransformers are very low; the transformers must tolerate quite high temporary overloading and be resistant to a great number of short circuits. Frequencies in AC-fed electric railways are 16,67 Hz, 25 Hz, 50 Hz or 60 Hz, and the power ratings are 4-15 MVA. An ABB specialty in catenary autotransformers is the kiosk mounting with an integrated oil sump. The transformer tanks are either hermetically sealed, corrugated and flexible, or vacuum resistant types with detachable radiators and oil conservators. Special transformers Railway transformers 3

Booster transformers Booster transformers are used in electric railway AC catenary feeders to collect the return current from the rails and the earth to the return conductor. Purpose In railways, the electric current is taken from the catenary conductor to the locomotive, where the energy is used by electric motors, and fed to the earth connected rails, which are part of the return circuit. From the rails, however, the return current may deviate around to unintended or harmful places like metallic pipelines, bridges, communication cables, etc. The stray currents bring about interference in communication systems and other electronic devices due to passing trains. Booster transformers are used to eliminate the stray currents and the disturbances, obliging the return current to flow to the return conductor. The use of booster transformers is growing due to new EMC regulations and the increasing amount of sensitive electronic appliances. Booster transformers are often used to improve old railway feeder systems. The transformer tank is hermetically sealed, corrugated and flexible, permitting liquid volume variation despite being totally filled. The booster transformer tank is usually hotdip galvanized for corrosion protection. The liquid immersed booster transformer is designed for outdoor installation. The usual style of installation is pole mounting in the catenary supporting steel poles near the catenary and return conductors. An ABB specialty in booster transformers is the kiosk mounting with an integrated oil sump. Pole and ground mountings are also possible. Booster transformers are single-phase transformers with the ratio 1:1. They have low impedance values, but despite that, they must tolerate the stresses of short-circuit currents. Primary voltages are typically 15 kv or 25 kv, which are the usual nominal AC voltages of catenary feeders in railways around the whole world. The nominal current is usually between 200A and 800 A. Frequencies in electric railways are 16,67 Hz, 25 Hz, 50 Hz or 60 Hz, and the power ratings of booster transformers are 100-800 kva. 4 Railway transformers Special transformers

AC traction feeder transformers Supply transformer Booster transformer Return conductor Catenary conductor Rail AC traction feeder transformers are used between normal threephase AC networks and single-phase catenary systems. Single and double voltage systems are used as in autotransformer and booster transformer applications. Railway companies possess their own single-phase HV lines. Singlephase feeder transformers are also used to reduce the voltages to the catenary level. AC traction feeder transformers are often equipped with an on-load tap changer (OLTC). Their strong structure is specially designed to resist repeated short circuits during the operation, which are common in electric railways. The power ratings of the AC traction feeder transformers are usually 7,5-25 MVA (up to 60 MVA in central Europe), and the high voltage runs up to 400 kv. Special transformers Railway transformers 5

Traction static converter transformers DC traction feeder transformers 16,67 Hz and 25 Hz systems are supplied from three-phase commercial AC systems with stationary converters of 50/16,67 Hz or 60/25 Hz. On the network side, these converters always contain a three-phase input converter transformer and a singlephase special output transformer on the catenary side. These transformers are specially designed for the converter technology and follow generally the principles explained in our brochure for the variable speed drive transformers. DC traction feeder transformers are used to feed rectifiers from normal three-phase AC networks. Rectifiers supply DC current to a catenary or third rail. Due to high currents and performance guarantees, DC traction feeder transformers are normally closely integrated with rectifiers. Therefore, they are specially designed and fitted together to match with the connection of the rectifier. The power ratings of the DC traction feeder transformers are below 1000 kva (tram supply), below 2000 kva (metro supply) and 2000-8000 kva (train supply with high currents up to 5000 A!). Typical DC voltages are 3 kv, 1,5 kv and 0,75 kv DC, and 0,6 W DC. DC traction feeder transformers are designed for tightly coupled series or parallel diode bridges (IPT), and they are supplied for 6-, 12- or 24-pulse connections. 6 Railway transformers Special transformers

Auxiliary transformers Isolation transformers Auxiliary transformers are used in three-phase auxiliary networks along the tracks (owned by railway companies) or powered from the catenary for lighting and other purposes. Auxiliary transformers are used eg, for lighting purposes, heating the train wagons or for producing single-phase auxiliary for the safety systems supply or the substation s own supply. Voltage levels normally follow the catenary systems below 36 kv and the power ratings are below 2 MVA for the track side threephase systems. Isolation transformers are special transformers, which are used to isolate the AC network from the DC leakage currents caused by DC rails in close proximity of AC rails. These transformers are typically 25/25 kv or 16/16 kv single-phase transformers, and the power ratings run up to 10 MVA. Due to the DC immunity requirements, an air gapped core design is needed in the isolation transformers. Therefore, strong test system is required in the factory. A lightning impulse test is always done as a routine test. Overvoltages are higher than normally, due to the air gapped core and the DC currents, which are present at switching whenthe train passes cut-off sections. Special transformers Railway transformers 7

Contact us ABB Oy Transformers P.O. Box 688 FI-65101 Phone: +358 (0)10 22 11 Fax: +358 (0)10 22 41 291 www.abb.com/transformers Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB Ltd. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained herein. Any reproduction, disclosure to third partiesor utilization of its contents in whole or in parts is forbidden without prior written consent of ABB Ltd. Copyright 2012 ABB. All rights reserved. 1LFI2026-en 12-08, Vaasa, Finland ISO 9001:2008 ISO 14001:2004 OHSAS 18001: 2007