Theater One (Upper level)



Similar documents
Operation Manual. Trans-Flo

LEDPAR64 USER MANUAL

SL STRIP 400 TW LED Luminaires

19 LED Tube Controller ORDERCODE 41003

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

Traktor Audio Configuration

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Rental Control During and After Las Vegas Events

LED Cube Direct Control 30 ORDERCODE 41131

Special Events & Space Rentals

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

Snapshot. LEDrain 38 USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Main Library Meeting Room Use

TOYOTA TACOMA HANDS FREE BLU LOGIC Preparation

SL1100 Installation Instructions. This Installation Packet is Organized into Five Chapters:

Thank you for purchasing the ButtKicker Gamer. This guide will help you to quickly set up your new ButtKicker system with your PC or gaming console.

Fire Alarm System Plans Review Checklist Property location Date of Review

Kiva Technology User s Manual

TECHNICAL SPECIFICATIONS.

1247 Norwood Avenue, Itasca, IL (800)

K E E P E TH T I H S I MA M N A U N A U L A FO F R

ComPar KIT 1 & 2 DMX LED light set

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

CEILING CASSETTE FAN COIL UNIT

SIT Sports. Safety Tracking System Manual WRC 2015

QUICK REFERENCE MANUAL

TECHNICAL SPECIFICATIONS Paramount website: Paramount

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Cooktop Low-Profile Ventilation Hoods

DIVERSITRONICS, INC. TM

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Other products available from Apollo

Equipment Guide Human Resources Training Room Suite 205, Building 3377

USER MANUAL PLEASE KEEP THIS FOR FUTURE USE

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

LED WALL WASHERS SPECIFICATIONS & INSTALLATION GUIDE

TOYOTA PRIUS HANDS FREE BLU LOGIC Preparation

KVT-729DVD INSTALLATION MANUAL

VK-250 WARRANTY REGISTRATION FORM

DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Event Planner/Venue Specialist Phone:

TCTC Cabling Specifications

Meydenbauer Center Audio Visual Services & Price Guide. Provided by Audio Visual Factory Inc.

Electrical. This section applies to the design and installation of building power distribution systems.

Model: LCDM LCD Rear Vision Mirror Monitor Installation Manual Features

VX 2400 Dimmer User's Manual

Model 201 Wiegand Touchpad Reader Installation Guide

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

K E E P E TH T I H S I MA M N A U N A U L A FO F R

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

SHUBERT THEATER 247 College Street, New Haven, CT

WARNING! REQUIRED TOOLS & SUPPLIES: HIGH VOLTAGE

Generator DoCKInG StatIonS

id led 4" square housing FL44

Cove lighting and tight space RGB LED luminaire

Douglas J. Cardinal Performing Arts Centre. Information and Technical Specifications

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

ComPar KIT 1 & 2 DMX LED light set with power outputs

SCD Server. SCD Server Pro

MEETING PACKAGES 400 LEVEL

DMX USB PRO. User Manual.

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

1. BEFORE YOU BEGIN INTRODUCTION SETUP AC POWER... 7 Power Linking... 7 MOUNTING... 8 Orientation... 8 Rigging...

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Figure 1-A This end of the cable is the side that will be plugged into the power adapter and DVR Card.

Contractors Guide Central Inverter System Installation

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

EVID Compact Sound Speaker System

LED PAR 64 SHORT FLOOR 20X3W PWM RGB

Laboratory Construction Guidelines Vicon MX Systems

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

QUICK START GUIDE. Thank you for purchasing the ButtKicker Kit. This guide will help you quickly set up your new ButtKicker Kit Contents: BK-Kit-4

C. Conform to requirements of Americans with Disabilities Act (ADA).

Stage Color LED. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 06/21/07

bba - Balboa Bluetooth Audio (AMP) Installation & User Guide

7x10W 4IN1 Indoor Par Light User Manual

VP HDMI to VGA Converter

Glolab Talking Phone Dial Monitor

Snapshot. User Manual. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave Autoswitching Power Supply Replaceable Fuse.

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

Warning! To prevent or reduce the risk of electrical shock or fire, do

VZ-M7 HDMI Field Monitor 7 Class HD LCD

MTX-D, Oil Temperature/Pressure Gauge

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

8-Ohm Ceiling Speakers For Music and Home Theater

Manual for GlobePharma Mini-Press II Rotary Tablet Press

HDCVI Series DVR Quick Start Guide

Reynolds Performance Hall Facility Regulations and Fee Schedule

ViZion Installation Guide

TECHNICAL RIDER

Transcription:

Last Update August 30, 2013 Theater Address: 64 East 4th St, New York, NY 10009 Mailing Address: 64 East 4th St, New York, NY 10009 General 64E4 Cultural Center is a flexible black box theater with 2 spaces Theater 1 seats up to 72 seats. Theater 2 seats up to 40 Dimensions: North-South: East-West: Proscenium: Thrust: Height: To Ceiling: 12 5 To Grid: 11 2 To Duct: 9 8 Theater One (Upper level) Upstage-Front Row playable space: 20 (w) x 18-21 (d)* Upstage-Front Row playable space: 25 (w) x 12.5 (d) *based on 72 seats or 60 seats setup North-South: East-West: Height: To Ceiling: To Grid: To Duct: Theater #2 (Lower level) Box Office: The Box Office is located at deck level on the 1st Floor. Technical Booth: Multiple power outlets, telephones, and desk space to accommodate production crew. Dressing Rooms: There are two (4) person dressing rooms at basement level, backstage in the basement. The stage manager will be provided with keys to lock and unlock the dressing rooms. Loading In/Out Load in through lobby - Building entrance 7 5 (h) x 5 8 (w) 64E4 Cultural Center does not have a loading bay, so all load-ins and load-outs must be done in the lobby of the building. This imposes a few restrictions -Architectural finishes in the lobby and hallway must need to be protected. (Packing blankets & masonite available.) -Since the load-in area is on the street, parking schedules should be carefully coordinated. Stages Stage Deck: Masonite: Fastening to deck is allowed only under theater Staff supervision with prior approval. Upon strike all holes must be filled and painted 1 of 9

Workspace: Painting: Marley: F/X: Flame proofing: Projection: There is no separate workshop space, so sets should arrive ready to be assembled. Modification is possible in the space, but sawing or welding must first be approved. Requests to paint the deck/walls must be submitted in advance to Technical Manager. Upon Strike theater must be painted back* (* Walls Paint color - Behr UL160-23D Floor Behr - Jet Black Semi-Gloss NO EXCEPTIONS) Marley is not available for 64E4 Cultural Center. When it is down, nothing may be screwed into deck through marley. Tap shoes, sharp points, or other damaging equipment may not be used. Please inform us immediately if any fog, cigarettes, open flames (including candles and matches) or other f/x are required for the 4 production. Material data sheets and descriptions for any and all permits required by the NYC and its agencies must be provided six weeks prior to company s arrival. Certificates for all materials and scenery must be provided before they enter the building. There is a chief mount to attach your projector. Rigging: 64E4 Cultural Center is equipped with a pipe grid. There is an AC duct on the West wall that lowers the grid. Grid is rated for 30lbs/linear foot dead load. No live/dynamic loads from grid. All rigging plans must be submitted six (6) weeks prior to your load-in, and are subject to approval. Support: Ladders (1) 8 Ladder (1) 10 Ladder Use of Toxic and/or Hazardous Materials Please be advised that the use of Toxic and/or Hazardous materials, including but not limited to: Flammable Materials Spray Paints (other than acrylic or water based) Acetone or other solvents Petroleum based products Non-water based adhesives is forbidden in any interior space of 64E4 Cultural Center without the express written, advanced notice of the theater management. Permission will only be granted upon review of the material and implementation of proper protective procedures. This policy will be strictly enforced and applies to the entire renting company. 2 of 9

Lighting: The lighting system consists of Theater One (Upper level) INSTRUMENTS: 5 ELED Fresnel II/ 100W lamp/ 10 to 50 Manual zoom/ 5 pin DMX data input & output/ Edison connector 10 ELED Par RGB Zoom/ 80W lamp/ 10 to 60 motorized zoom/ 3-pin DMX serial input/output/ Edison connector 27 SF Zoom 25/50 degree/ 575W / Stage pin connectors 7 36 degree SF 575W / Stage pin connectors TOTAL INSTRUMENTS = 49 CABLE 20 5 Jumpers/ stage pin connectors 18 10 Jumpers/ stage pin connectors 2 25 Jumpers/ stage pin connectors TOTAL CABLE: 40 CONTROL AND DIMMERS 48 2.4K ETC Unison dimmers 48 Circuits on grid/ 12 Pigtail boxes w/4 circuits each 3 Edison outlet boxes (2 outlets each) with signal outputs for LED lights 1 ETC Element 60/500 Lighting console w/ cover 2 LCD Monitors for Lighting console w/cover 4 25 DMX data cables 10 10 DMX data cables 5 5 DMX data cables for ELED Fresnels 10 10 DMX 3 pin female/ 3pin male cable for ELED Pars 10 DMX Adapters 3pin male to 5pin female 10 DMX Adapters 3pin female to 5pin male ACCESORIES 27 7 ½ gel frames for SF Zooms 7 6 ¼ gel frames for 36 degree SF 5 7 3/4 gel frames for ELED Fresnels 49 Safety cables 5 Barndoors for ELED Frenels No food or drinks are allowed in the theater/ lighting booth. Please clear the show on the console after rental period is over. All lights have working lamps and they must be returned in the same condition. We don t provide spare lamps. If the renter want s to bring in more equipment, the list has to be approved by Choicircitati before load in. Renters are not allowed to bring additional instruments without approval. If you need more information on the lighting console you can download the manual from the Internet. Please note that we don t have Edison jumpers in our inventory. Renters need to bring those if needed. There are three circuit/net boxes mounted to the SL wall at grid height. Each box has 2 dedicated non-dims and one DMX port. All three ports are on Universe 3. These net boxes are to be used for the LED lights. 3 of 9

The non-dim circuits located on the ceiling of the theater are controlled by circuit breakers in the booth (#30, 32, 34, 36, 38, & 40). They are labeled. The console must be connected to the control box located in the corner of the booth by both DMX port 1 and the network port in order for the entire system to function. The LED fixtures will need to be prepped (DMX mode and address set) prior to hang. If you need more information on these fixtures please download the manual from the Internet. Please be careful when hanging anything on the grid as the main circuit cables are directly attached to the grid. Circuit boxes can t be moved from their actual positions. You can t hang anything over the multi cable, on the sprinkler pipes, nor the black electrical conduit. At the end of the rental we will check out the inventory with the renter. Any missing or damage items will be deducted from the security deposit at market value. The renter needs to make sure during load not to leave on the grid any tapes, tie lines, cables etc. that were load in for the rental period. The grid should be returned in the same condition it was given to the renter. INSTRUMENTS: Theater #2 (Lower level) 4 ELED Fresnel II/ 100W lamp/ 10 to 50 Manual zoom/ 5 pin XLR data input & output/ Edison connectors 8 ELED Par RGB Zoom/ 80W lamp/ 10 to 60 motorized zoom/ 3-pin XLR serial input/output/ Edison connectors 9 50 degree SF 575W / Stage pin connectors 11 36 degree SF 575W / Stage pin connectors TOTAL INSTRUMENTS = 32 CABLE 15 5 Jumpers/ Stage pin connectors 10 10 Jumpers/ Stage pin connectors 2 25 Jumpers/ Edison connectors TOTAL CABLE: 27 CONTROL AND DIMMERS 5 Scrimmer Sticks dimmers with 4 600W circuits each for a total of 20 dimmers 1 ETC Express 48/96 lighting console with cover 1 Monitor with cover 1 Distribution box located at booth 2 25 DMX data cables 5 10 DMX data cables 4 5 5 pin XLR data cable for LED Fresnels 8 5 3 pin XLR data cable for LED Pars 7 DMX adapter 3pin male to 5pin female 3 DMX adapter 3pin female to 5pin male 4 of 9

ACCESSORIES 20 6 ¼ gel frames for SF 4 7 3/4 gel frames for ELED Fresnels 32 Safety cables 4 Barndoors for ELED Fresnels No food or drinks are allowed in the theater/ lighting booth. Please clear the show on the console after rental period is over. We don t provide spare lamps or diskettes. **The theater power can t sustain more lighting instruments/ dimmers than the ones provided. We won t allow additional lighting equipment except for low wattage practicals. The renter is responsible for the equipment. Any missing parts or units have to be replaced prior to load out date. All lights have working lamps and they must be returned in the same condition. If you need more information on the lighting console you can download the manual from the Internet. Please note that we don t have Edison jumpers in our inventory. Renters need to bring those if needed. The LED fixtures will need to be prepped (DMX mode and address set) prior to hang. If you need more information on these fixtures please download the manual from the Internet. At the end of the rental we will check out the inventory with the renter. Any missing or damage items will be deducted from the security deposit at market value. The renter needs to make sure during load not to leave on the grid any tapes, tie lines, cables etc. that were load in for the rental period. The grid should be returned in the same condition it was given to the renter. 5 of 9

Sound: All audio cables running from speakers/grid to the booths are color coded. For detailed information, see the respective theater's Speaker Positioning and Color Coding Plot. The sound system consists of EQUIPMENT: Theater One (Upper level) 1 Mackie DL1608 Mixer 1 Mackie Accessories (DL1608 mixer manual. Pad lock & key) 1 Pyle Pro 8 channel amp PT800 6 Pyle pro speaker cabinets 2 Stageworks speakers (in closet) 1 M-Audio Subwoofer, SBX10 1 ipad, 3rd Generation 1 ipad charger (USB cable and wall adaptor) 1 1 M-Audio S.W mute pedal. (In plastic package) CABLE & ACCESSORIES 4 Male XLR to female 1/4 turnarounds 1 Male 1/4 to female XLR turnaround 1 Male 1/4 to female 1/8 adaptor 1 Male XLR to Male XLR turnaround 1 Hosa Cable Pro-Conex Little Bro 8 inputs Live Audio Snake 1 S.W Power a/c cable 1 TRS to 1/8 inch cable 2 Female XLR to RCA cables 1 Single TRS to single XLR 100 ft cable (for subwoofer) 2 Dual TRS to RCA cables 8 Color coded grid cabling: 6 cables connected to speakers & 2 cables on grid to be used stageworks speaker cabinets when live, floor monitors are required. 4 Spansets 12 Ratchet straps INSTRUMENTS: Theater #2 (Lower level) 1 Sony STR DE197 Amplifier 2 JBL jet black speakers 2 Pyle Pro cabinet speakers CABLE & ACCESSORIES 1 1/8 to RCA cable 2 Color coded grid cabling: 2 Spansets 6 Ratchet straps The renter is responsible for the equipment. Any missing parts or cable must be replaced prior to load out date. 6 of 9

For assistance, please contact: 64E4 64 East 4th St. New York, NY 10009 (212)505-6757 CHOICES/PARADISE CIRCULO IATI theater@paradisefactory.org José Cheo Oliveras Winston Estevez Executive Director IATI Theater Artistic Director Tom Noonan joliveras@teatrocirculo.com (voice) Artistic Director (917) 657-3057 (voice) tom@tomnoonan.com Pope Jackson Talia Lugacy Technical Manager lugacy@gmail.com Pope@ActuatorInc.com (646) 708-5687 7 of 9

Speaker Positioning and Color Coding Plot Choicirciati, Theater #1 64 E 4th Street, New York, 10003 Green Blue Yellow Speakers on grid (6): Pyle-Pro PADH 879 Floor monitoring speakers (2): Stageworks VP15 2 tricolor coded speaker wires coiled on grid for 2 movable floor monitors. Black White Red Control Booth 8 of 9

Speaker Positioning and Color Coding Plot Choicirciati, Theater #2 64 E 4th Street, New York, 10003 Yellow - #3 PADH879 Speaker Blue - #4 JBL L40 Speaker Green - #2 JBL L40 Speaker Red - #1 PADH879 Speaker Control Booth 9 of 9