Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control



Similar documents
3/2 Solenoid Cartridge Valve, Size 6

Seat Valves. 1 Description. Series SVH Technical data. 1.2 Performance graphs

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

Chapter 5: Flow Valves

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Chapter 6: Check Valves

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

SOLENOID VALVES 3-4 WAY

2/2 and 3/2 Way Size 6 Seat Valves

Unit 24: Applications of Pneumatics and Hydraulics

2-way flow control valve Type 2FRM 6

15/40/80CN Series Medium Pressure Filters

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3/2- and 2/2-way cartridge valve type BVE

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

4/2-Way Pneumatic Solenoid Valve

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

MANTA Piston Distributor for Oil and Fluid Grease

Open center control block in monoblock design MO-40

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Load-sensing control block in mono and sandwich plate design

SOLENOID VALVES AND PNEUMATIC VALVES

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Actuators and Sensors. Products

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Pressure reducing valve, direct operated, Type ZDR 6 D

Directional seated valves type VP 1

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Variable Displacement Pump AA10VSO

Check Valves Valve locator

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

3/2-way Solenoid Valve, direct-acting, NC or NO

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Proportional pressure regulators VPPE

Axial Piston Variable Motor A6VM

Dual Path Mobile Pump

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Pressure Relief Valves SPV, SPVF

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Control block EDD Modular Directional Valve

Pressure relief valves Size 6

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Electro-hydraulic pressure switches type DG

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

G1/4 Q8. Standard with biased position

Hydraulic Flow Control Valves

Directional seated valves Directly actuated, leakagefree for hydraulic systems For the assembly on connection sub-plates

Hydraulic Control Solutions

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

3/2-way pneumatic cartridge solenoid valve

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

COUNTERBALANCE VALVES

Electro-pneumatic control valves

On-off valves MS-EM/EE, MS series, NPT

Assisted lift operated 2/2-way solenoid valves Type EV250B

System 8. ü ( System 8

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

1. General. D 7490/1 2/2-way cartridge valve EM 2.2. Operation pressure p max Flow Q max. = 450 bar = 160 lpm. Cartridge valve (see section 2)

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Fixed displacement vane pumps

Line rupture protection valves type LB

Single sub-base valve

type V46, solenoid or pneumatic operated

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

3/2-way Mini Solenoid Valve

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

PUMP AND MOTOR DIVISION

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Axial Piston Variable Pump KVA

RADIAL PISTON PUMPS (RKP)

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Data Sheet. Electro-mechanical counters Hengstler 800 series

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

The Professional Choice. LDC With DC motor. OLAER LDC optimized for mobile use

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

RA / Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

4 Posiflow Proportional Solenoid Valves

Pressure Relief and Regulating Valves

Transcription:

Flow Control Valve Series SRCB.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised in open center robust, durable and reliable 1 Descriptions 1.1 Generals Flow control valves SRCB are used to set the working speed of hydraulic actuators, the setting is load independent and pressure compensated. The flow rate is set by an adjustable slit-type orifice. When used as a 3-way valve, the higher pressure can be either at the A or B port. For a 2-way flow control function please ask Bucher Hydraulics. The special orifice design ensures that the flow setting is largely independent of the viscosity of the fluid. The valve's cartridge construction allows to design a hydraulic system that meets the client's precise reuirements. 1.2 Application examples Harvesters Sweepers Refuse collection vehicles Fertiliser spreaders Snow and ice clearing euipment Mowers Road rollers Municipal vehicles Forestry machines Wood chippers 2 Symbols 2.1 2-way flow control 2.2 3-way flow control P A P A P A P A B B For 2-way flow control functions please contact Bucher Hydraulics. Reference: 100-P-000091-EN-09 Issue: 01.2016 1/9

3 Technical data General characteristics Unit Description, value Design Flow direction Seals De-energised position Mounting attitude Commissioning screw-in cartridge P A controlled P B surplus flow discharge (can be pressurised) Viton (FPM) normally closed unrestricted; preferably with coil at bottom end (automatic air bleed) bleed all air from the system (if possible, operate valve several times without load) Electrical characteristics Unit Description, value Design high pressure; wet armature Supply voltage V DC 12 or 24 from an electronic controller Power consumption W 27.6 with 12 V coil and Imax. = 2,3 A 27,6 with 24 V coil and Imax. = 1,15 A Dither freuency reuired Hz 100 (observe I max. ) Relative duty cycle 100 % at I max. Protection class (with a properly-fitted plug) DIN plug - IP54 AMP Junior Timer - IP65 Deutsch plug - IP67 Electrical connection plug-base with pins to DIN 43650 AMP Junior Timer plug connector (2-pole) Deutsch plug DT04-2P-EP04 Hydraulic characteristics Unit Description, value Constant flow range l/min 10, 16, 25, 32, 40, 50, 63, 80 1) Inlet flow l/min max. 100 1) Operating pressure bar max. 315 2) Leakage cm 3 /min max. 100 cm 3 /min at 100 bar 1) Min. pressure difference (pressure compensator) bar 7 Control accuracy (as a % of the nominal flow): Load-dependency when under pressure Hysteresis when operated max ± 2,5 % 3) max ± 3,5 % 3) Fluids mineral oil to DIN 51524 and DIN 51525 4) Fluid temperature range C -20... +80 Viscosity range mm 2 /s 10... 300 Filtration NAS 1638 class 9, ISO 4406 class 20/18/15; achievable with a filter rating of ß 10 75 1) Values refer to an oil viscosity of 35 mm 2 /s (cst). 2) For higher pressures, consult Bucher Hydraulics 3) Values refer to the selected flow range. 4) for other fluids, consult Bucher Hydraulics. 2/9

4 Performance graphs 4.1 Q / I characteristics Q (%) 4.2 Variation in flow Q A [l/min] 100 75 50 +3,5% max -3,5% Q 2 3 Q max Q 25 1 4 0 850 1150 1500 2000 400 600 800 1000 I (ma]) à 12 V I (ma]) à 24 V 0 50 100 150 200 250 p (bar) 1 Fine control range 3 Q A - constant flow pressurised 2 100% = 2000 ± 200 ma at 12 V = 1000 ± 100 ma at 24 V (100%- values vary with nominal flow rate) 4 Q A - surplus flow pressurised 4.3 Pressure drop during vented bypass P B p [bar] 14 12 10 8 6 4 5 6 7 5 Pressure loss area (The actual pressure-loss characteristic is dependent on the tank pressure at port B) 6 Control valve throtting curve (Dependent on applied body) 7 Control - p - characteristic 7 bar 2 0 0 20 40 60 80 100 Q zu [l/min] 5 Dimensions 5.1 Revision status 0 5.2 Revision status 01 63 175 65.5 175.5 B A B A M42x1,5 P ø45 M 42 x1,5 45 SW50 MA= 50Nm SW36 MA= 50Nm 3/9

6 Models 6.1 Manual override Emergency pin, SRC...S.. M A = max 6 Nm Ó ÓÔ ÓÔ Ó 1 M A = 13 Nm max 2mm IMPORTANT : By pressing the solenoid pin (1), you operate the valve ON/OFF Basic manual override, SRC...N.. Q 0 to Q max. = of approx. 3,5 turns at the handle Basic manual override, SRC...T.. Q 0 to Q max. = of about one turn at the handle ca. 188 ca. 202 6.2 Sockets GDM plug to DIN 43650 -G..- AMP Junior Timer -J..- Deutsch plug DT04-2P-EP04 -T..- 4/9

7 Ordering code S R C B 0 5 0 S 3-0 G 1 2 / Flow control valve SR Cartridge Size Constant flow range (10, 16, 25, 32, 40, 50, 63, 80 l/min) e.g. 0...50l/min = 050 Type of operator solenoid + emergency pin = S solenoid + basic manual override = N solenoid + deluxe manual override = T 3-way = 3 2-way (for this function please ask Bucher Hydraulics) = 2 Design number = 0 = stop of production by 31.12.2013 = 01 Plug connector GDM plug (DIN) = G AMP Junior Timer = J Deutsch plug = T Proportional solenoid supply voltage DC 12 Volt = 12 DC 24 Volt = 24 Options (to be inserted by the factory) IMPORTANT : The design number 0 may not be used for new projects. This version will be stopped by 31.12.2013. 8 Hub housing 8.1 Shape of bore CSRCB3 for 3-way flow control valves 3,2 1,5 - max 5 ø57 M42 x 1,5 Z ø0,025 0,025 8.2 Processing for detail Z M5:1 ø49 1,6 0,1 66 46-0,2 30 22 max ø12 B 1,6 1,6 30 30 A max ø12 24-0,2 52 3,2 3.1 +0,4 ø44.4 +0,1-0,3 0,1 P 1 ø35 ø37 +0,05 +0,05 ø0,025 (M42x1,5) 1 The drilling is not reuired for 2-way flow controls Form tools for customers who wish to machine their own cartridge cavities are available (Artikel Nr.: 100.609209). IMPORTANT : The fixing holes are identical with the hub housing SR3CVM. 5/9

8.3 Ordering code S R C B V M 2-2 * * 2-0 M 2 2 * * * / Mounting body for SRCBV cartridge valve Type Separate unit single = M1, double = M2 Motor mtg. (RS29) single = R1, double = R2 Inlet section = E* Intermediate section = Z* End section = A* Bolt-on section = AP Service line relief for 1st controller in P in A None = * = * Pressure range 3-30 bar 1) = 0 = 4 Pressure range 30-70 bar 2) = 1 = 5 Pressure range 70-200 bar = 2 = 6 Pressure range 200-300 bar = 3 = 7 Service line relief for 2nd controller in P in A None = * = * Pressure range 3-30 bar 1) = 0 = 4 Pressure range 30-70 bar 2) = 1 = 5 Pressure range 70-200 bar = 2 = 6 Pressure range 200-300 bar = 3 = 7 Service line relief for 3rd controller in P in A None = * = * Pressure range 3-30 bar 1) = 0 = 4 Pressure range 30-70 bar 2) = 1 = 5 Pressure range 70-200 bar = 2 = 6 Pressure range 200-300 bar = 3 = 7 Additional functions None = * For use with LS pump = L With bypass check valve = R With anti-cavitation for 1st controller = 1 2nd controller = 2 3rd controller = 3 1st and 2nd controller = 4 1st and 3rd controller = 5 2nd and 3rd controller = 6 1st, 2nd and 3rd controller = 7 Design no. (to be insert by the factory) Port threads DIN 3852 - M22 x 1,5 = M22 (other threads - contact Bucher Hydraulics) Nominal voltage of proportional solenoid (for bodies with solenoid operated valves) DC 12 Volt = G12 DC 24 Volt = G24 None = *** Variants / special features (to be insert by the factory) 1) only up to Q max = 25 l/min 2) only up to Q max = 40 l/min IMPORTANT : The flow control valves must be ordered separately as detailed in section 6. Existing mounting body SR3CVM could also be used. 6/9

9 Installation information 10 Fluid 11 Fluid cleanliness class Flow control valves reuire fluid with a minimum cleanliness Cleanliness class (RK) onto ISO 4406 and NAS 1638 level of NAS 1638, Class 9 or ISO 4406, code 20/18/15. We recommend the use of fluids that contain anti-wear additives for mixed-friction operating conditions. Fluids without appropriate additives can reduce the service life of pumps and motors. The user is responsible for maintaining, and regularly checking the fluid uality. Bucher Hydraulics recommends a load capacity of > 30 N/mm2 to Brugger DIN 51347-2. IMPORTANT! When mounting the valve, ensure that the body is not subjected to any distorting forces. If necessary use shims to eualise the level of the mounting points. Do not use any pipe fittings with tapered-threads! Code ISO 4406 Number of particles / 100 ml 4 m 6 m 14 m NAS 1638 23/21/18 8000000 2000000 250000 12 22/20/18 4000000 1000000 250000-22/20/17 4000000 1000000 130000 11 22/20/16 4000000 1000000 64000-21/19/16 2000000 500000 64000 10 20/18/15 1000000 250000 32000 9 19/17/14 500000 130000 16000 8 18/16/13 250000 64000 8000 7 17/15/12 130000 32000 4000 6 16/14/12 64000 16000 4000-16/14/11 64000 16000 2000 5 15/13/10 32000 8000 1000 4 14/12/9 16000 4000 500 3 13/11/8 8000 2000 250 2 7/9

12 Electronics For controlling SR... flow control valves, we recommend the ELSK 106 series of control units and plug-in cards. These are used to control 1 or 2 proportional solenoids and can also operate on/off solenoids and other auxiliary functions. Plug-in cards are available, and control units can be supplied. The folowing table contains a small selection of the extensive range of accessories and electronics from Bucher Hydraulics. Picture Type Description Order-No. ELSK106-01***/11 Data sheet: 100-P-700008 Makrolon housing with magnetic clamp, rotary potentiometer, indicator knob; LED 100026578 ELSK106-02***/11 Data sheet: 100-P-700008 Makrolon housing with magnetic clamp, rotary potentiometer, indicator knob, ON/OFF switch, LED 100026579 ELSK106-09*** Data sheet: 100-P-700008 Robust aluminium housing with 2 set-point potentiometer, 3 toggle switches,a LED and socket insert STAF 14 100032782 ELSK106-10*** Data sheet: 100-P-700008 Robust aluminium housing with 2 set-point potentiometer, 3 toggle switches,a LED and socket insert STAF 14 100032531 ELSK106-14*** Data sheet: 100-P-700008 Robust aluminium housing with 2 set-point potentiometer, 3 toggle switches,a LED, a key switch (starter) and socket insert STAF 14 100032159 8/9

13 Specification sheet flow control valve, series SRC Order Enuiry Company: Address: Code/Location: Country: Customer No. Phone number: Fax number: E-mail address Ordering code (see Sect. 6) Quantity SRCB - 0 SRCB - 0 SRCB - 0 SRCB - 0 13.1 Details of the application Operating pressure (bar): Inlet flow (l/min): Max. intermittent pressure (bar): Controlled flow rate (l/min): Fluids: Mineral oil Biodegradable oil Other HFA HFC HFD Fluid temperature range (5 ): Viscosity range (mm 2 /s) (cst): Supply system: Fixed-disp. pump Constant-pressure pump Var.-disp. pump, LS Variable-displacement pump, power-limited Name Date Signature info.kl@bucherhydraulics.com www.bucherhydraulics.com 2016 by Bucher Hydraulics GmbH, D-79771 Klettgau All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 430.310.310.330.305 9/9