Carlon Expansion Fittings for PVC Rigid Nonmetallic Conduit



Similar documents
KINETICS RISER SUPPORT SYSTEMS

Understanding Shaft Alignment: Thermal Growth. Published in Maintenance Technology 1/2003

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

4 Installation Requirements

PEX TUBING FAQ WHAT IS PEX?

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Solvent Cementing Instructions For Plastic Pipe & Fittings

SAM Teachers Guide Heat and Temperature

HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

Rigid Conduit, Fittings, and Accessories Frequently Asked Questions

PTFE Slide Bearings 04/10 149

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Arctic Leash Instruction Manual Alaskan Products Company LLC.

Application Guide. Compensators Hose Assemblies Expansion Joints FLEX-WELD INCORPORATED FLEX-WELD.COM. Manufactured By:

Chapter 7 Plumbing Connections

Section SEWER PIPE INSTALLATION AND TESTING

Key energy-efficient features of your new home

2. Room temperature: C. Kelvin. 2. Room temperature:

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

EF70-300mm f/4-5.6 IS USM

MEASUREMENTS OF THRUST LOAD IN CABLE SYSTEMS SEMI-RIGIDLY INSTALLED IN DUCT / MANHOLE STRUCTURES

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

CTI TECHNICAL BULLETIN Number 6: A publication of the Cable Tray Institute

CASE HISTORY #2. APPLICATION: Piping Movement Survey using Permalign Laser Measurement System

Installation Instructions For Slider Casement Air Conditioners

Nozzle Loads, Piping Stresses, and the Effect of Piping on Equipment

SHAFT VERSUS FOOT ALIGNMENT TOLERANCES A Critique of the Various Approaches by Alan Luedeking, Ludeca, Inc.

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

A99B Series Temperature Sensors

Handling, Erection and Bracing of Wood Trusses

LIFE SCIENCE. Hoop House Construction for New Mexico: 12-ft. x 40-ft. Hoop House BRINGING TO YOUR HOME ECONOMICS COLLEGE OF AGRICULTURE AND

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Mobile Home Pre-Inspection Checklist

TubeTrace, ThermoTube

Name: Class: Date: 10. Some substances, when exposed to visible light, absorb more energy as heat than other substances absorb.

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

Ceiling Mounted Folding Attic Ladders Installation Instructions

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

SMarT_Foundation [Simple Modular Technology] Assembly and Installation Instructions (U.S. Patent Pending)

LED MOTION ACTIVATED FLOOD LIGHT

Cold Weather Concrete Practices

Calculating Heat Loss by Mark Crombie, Chromalox

HOW TO-SOLAR HOT WATER

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

Carlon Bore-Gard and Boreable Multi-Gard Raceway

GEOTHERMAL HEAT PUMPS - TRENDS AND COMPARISONS - John W. Lund Geo-Heat Center

Shaft- Mounted Speed Reducers

White paper on the comparative energy efficiency of zoned electric heaters Convectair, Inc. / Convectair-NMT Inc. September 2004

Shingle Installation Guide

Easy and Reliable Secondary Containment Piping System Split Pipe and Fittings Solid Pipe

How Ground/Water Source Heat Pumps Work

How to build a high tunnel

How does solar air conditioning work?

Ontario Electrical Safety Code - Info Sheet

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Temperature. Temperature

Carlon Carflex Liquidtight Flexible Tubing

INSTRUCTIONS FOR CHAIN LINK INSTALLATION Chain Link fence & Posts Meshdirect.co.uk

CT-02 CABLE TRAY SYSTEMS

OD PRECISION MEASURING INSTRUMENTS

Specification Guidelines: Allan Block Modular Retaining Wall Systems

BARREL ALIGNMENT- A CRITICAL FACTOR IN REDUCING EXTRUDER WEAR

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Window Types and Materials

Cable Installation Notes

Assembly Instructions for the InteliTrack 3000 Rail Tracking System

EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS

Heat Transfer: Conduction, Convection, and Radiation

R-Value and Thermal Conductivity of PEX and PE-RT TR-48/2014

Cooling system components, removing and installing

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

SECTION 724 PIPE CULVERTS

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

Thermal Imaging for Home Inspectors

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

TL-12 Passenger Car Alignment System

Chapter 4: Transfer of Thermal Energy

Metal Free Standing Canopy Assembly Instructions

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Heat-Pipe Heat Exchanger

MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions

Cabinets 101: Configuring A Network Or Server Cabinet

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Types Name Description. Films Polyethylene 4 and 6 mil Regular UV. Rigid Plastics Fiberglass" Fiber reinforced. "Plexiglass" or equal

POTABLE PIPING SYSTEM

ASX7-4-IOM-7 J

6. Block and Tackle* Block and tackle

Chesapeake Section AWWA Symposium

UNIT 6a TEST REVIEW. 1. A weather instrument is shown below.

Transcription:

Carlon Expansion Fittings for PVC Rigid Nonmetallic Conduit All construction materials expand and contract with fluctuations in temperature. These temperature changes affect polyvinyl chloride (PVC) more than traditional materials such as aluminum and steel. For example, the coefficient of thermal expansion for PVC (3.38 x 10-5 in./in./ F) is almost three times as high as for aluminum and six times as high as for steel. Thermal expansion and contraction have a significant effect on long straight runs of conduit. For this application, expansion fittings are used to accommodate changes in length. This prevents potentially harmful thermal stresses in the conduit itself or in any supporting structures. Male Terminal Adapter End Coupling End The National Electrical Code Requirements Section 352.44 of the National Electric Code requires that expansion fittings be installed for rigid nonmetallic conduit to compensate for thermal expansion and contraction where the length change is anticipated to be 0.25 in. (6.36mm) or greater, When are expansion fittings used? The importance of knowing when to use an expansion fitting is as important as knowing how to use an expansion fitting. Expansion fittings are used in aboveground installations where temperature changes are anticipated to exceed 25 F (14 C). in accordance with Table 352.44 of the NEC, in a straight run between securely mounted items. Securely mounted items are boxes, cabinets, elbows, or other conduit terminations. Expansion fittings are usually used where the straight run length is greater than 25 feet and expected temperature change is greater than 60 F. Rigid PVC conduit has a coefficient of expansion of 3.38 x 10-5 in./in./ F. A 10 foot length will change in length about 3/8" with a change in temperature of 100 F. This equates to more than 4 inches over a 100 foot run. Piston Mid-Point Indicator Barrel

When are expansion fittings used? (continued) Changes in conduit temperature outdoors can exceed 140 F considering the heat of summer and cold of winter. This means a 100 foot run of conduit could change approximately 6 inches in length between summer and winter. If not compensated for with expansion fittings, this change in length can cause unsightly conduit bowing, distorted boxes, or broken couplings or fittings. The anticipated expansion and contraction for various lengths of runs and temperature changes is given in Table 352.44 of the National Electric Code. (See Table below) Expansion Characteristics of PVC Rigid Nonmetallic Conduit Coefficient of Thermal Expansion = 3.38 x 10-5 in./in./ F 5 0.2 55 2.2 105 4.2 155 6.3 10 0.4 60 2.4 110 4.5 160 6.5 15 0.6 65 2.6 115 4.7 165 6.7 20 0.8 70 2.8 120 4.9 170 6.9 25 1.0 75 3.0 125 5.1 175 7.1 30 1.2 80 3.2 130 5.3 180 7.3 35 1.4 85 3.4 135 5.5 185 7.5 40 1.6 90 3.6 140 5.7 190 7.7 45 1.8 95 3.8 145 5.9 195 7.9 50 1.8 100 4.1 150 6.1 200 8.1 For conduit installed outdoors, the maximum and minimum air temperature expected can be used to calculate the range of expansion and contraction. Conduit installed outdoors in direct sunlight will be considerably hotter than air temperature during the day because of the absorption of the sun s heat. Expansion fittings should be installed to allow for the anticipated temperature change. For direct sunlight exposure, add 30 F to ambient air temperature change. Where installed inside buildings, the conduit temperature is the ambient air temperature plus the heat contributed by the conductors inside the conduit. Generally, expansion fittings are not required inside unless conduit is located in an area of widely varying temperatures. Attics of buildings are areas where temperature swings exceeding 100 F are common and expansion fittings are required.

of Run (Feet) Inches of Expansion Allowance Needed for Changes of: 60 F 80 F 100 F 120 F 140 F 25 5/8 3/4 1 11/4 13/8 50 11/4 15/8 2 23/8 23/4 75 13/4 2 3 /8 3 31/2 41/8 100 23/8 31/8 4 43/4 51/2 125 3 4 5 6 7 150 35/8 43/4 6 71/8 81/4 Add 30 F to temperature change for direct sunlight exposure. Proper Position Expansion fittings are usually installed in a horizontal position. However, if they must be put in a vertical application, the open end should be securely fastened in the down position. The expansion fitting must be installed close to the top of the run with the barrel pointing down, so that rain water does not enter into the opening. The lower end of the conduit run should be secured at the bottom. This will result in an upward movement due to the length change caused by temperature variations. Solvent weld Pipe strap should be anchored tightly to barrel Mid-point Piston opening Solvent weld Pipe strap mounted loosely to allow movement Setting Position of Piston If an expansion fitting was installed completely closed with the piston bottomed on a cool day, there would be no travel available when the conduit warmed up and expanded. If it was installed in a maximum open position on a hot day, the expansion fitting would pull apart when cooled. Thus, setting the expansion fitting is very important. In addition to the proper number and sizes of expansion fittings chosen, they must also be installed so they can accommodate the expected length change. This requires proper setting of the expansion fitting. Most will be installed at a temperature halfway between maximum and minimum; for example, installation at 65 F with an anticipated maximum temperature of 125 F and a minimum of 5 F. In this case, the expansion fitting would be installed or set with the inner piston halfway out. Expansion fittings are marked with a mid-point. If it was a colder day, for example 35 F with the same expected temperature change range, the inner piston would be set with 1/4 of its maximum travel out. If the temperature was hot (95 F), it would be set with the inner piston only 3/4 way out.

Setting Expansion Fitting for A. For medium temperature (65-75 F) set piston 1/2 way in barrel. B. For cold temperature (20-30 F) set piston 1/4 way in barrel. C. For hot temperature (95-105 F) set piston 3/4 way in barrel. When a more precise calculation for expansion is needed, it can be calculated as follows: Example 1: 1. You must determine the maximum temperature range. This is done by subtracting the lowest temperature you anticipate from the highest temperature you anticipate. Example: Let s say in winter, we expect the temperature to get down to -10 F and in the summer, we expect the temperature to get as high as 110 F. The maximum temperature range is 110 (-10) = 120 F. 2. The length of run between fixed points must be determined. Let s assume 90 feet for this example. 3. The total expansion change can be calculated as follows: Total expansion change in inches = (coefficient of thermal expansion) x (maximum temperature range) x (length of run in inches). Example: Total expansion change = (3.38 x 10-5 in./in./ F) x (120 F) x (90ft x 12in./ft) = 4.38 in. Thus, travel can be covered with one expansion fitting in Carlon trade sizes 2" through 6", which have an 8" travel, or two expansion fittings in Carlon trade sizes 1/2" through 1-1/2", which have a travel of 4". 4. The set position can be determined from the following example. Example: If the temperature at installation was 65 F, the difference from maximum is 110 F 65 F = 45 F. Use ratio: (difference from maximum)/(total expected range) = 45/120 =.375 in. (0.375) x 8 inch travel = 3 in. The piston at 65 F would retract 3 inches. Example 2: 1. You must determine the maximum temperature range. This is done by subtracting the lowest temperature you anticipate from the highest temperature you anticipate. Example: Let s say in winter, we expect the temperature to get down to 20 F and in the summer, we expect the temperature to get as high as 100 F. The maximum temperature range is 100 20 = 80 F. 2. The length of run between fixed points must be determined. Let s assume 90 feet for this example. 3. The total expansion change can be calculated as follows: Total expansion change in inches = (coefficient of thermal expansion) x (maximum temperature range) x (length of run in inches). Example: Total expansion change = (3.38 x 10-5 in./in./ F) x (80 F) x (90ft x 12in./ft) = 2.92 in. Thus, travel can be covered with one expansion fitting. 4. The set position can be determined from the following example. Example: If the temperature at installation was 65 F, the difference from maximum is 100 F 65 F = 35 F. Use ratio: (difference from maximum)/(total expected range) = 35/80 =.4375 in. (.4375) x 4 inch travel = 1.75 in. or (.4375 x 8 inch travel) = 3.5 inches The piston at 65 F would retract 1.75 inches for Carlon trade sizes 1/2" through 1-1/2" or 3.5 inches for Carlon trade sizes 2" through 6.

Installation 1. The expansion fitting should be mounted so that the piston can travel in a straight line within the barrel. If alignment is not straight, the piston will bind and prevent the fitting from working properly. 2. The expansion fitting barrel must be clamped securely whereas the conduit is mounted loosely so that it can slide freely during expansion and contraction. 3. Nonmetallic conduit straps suitable for this purpose, must be used to allow the conduit to move freely during expansion and contraction while properly securing it. One Expansion Fitting Run conduit through loose support Expansion fitting barrel fixed rigid Two Expansion Fittings Run conduit through loose support Both expansion fitting barrels fixed rigid Location Proper placement and installation of expansion fittings and conduit allow for correct functioning of the expansion fittings. For example, if one expansion fitting is needed between two boxes, the barrel of the fitting must be securely fastened close to one box. The conduit must be fastened loosely so as to allow for movement during expansion and contraction. If there is more than one expansion fitting used, then fittings are installed at the boxes with the center of the conduit run rigidly fixed. With two expansion fittings utilized, the center of the conduit must be fixed so as to properly proportion expansion or contraction between the two fittings. Otherwise, the expansion or contraction would only occur at the free fitting, while the tighter fitting would not move. In a very long run, two or more fittings should be placed in series with one another. The barrels of each expansion fitting must be anchored so as to allow each length of conduit to expand or contract freely. Each section acts independently. Use of Expansion Fittings Where Concrete Encased or Direct Buried In normal circumstances, expansion fittings are not needed with concrete encased nonmetallic conduit since the movement of the conduit will coincide with the expansion and contraction of the concrete. The only place where an expansion fitting would be utilized is where the concrete itself has an expansion joint. Most Common Mistake The most common error is not using enough expansion fittings. When in doubt, use an additional expansion fitting. It is much more difficult and costly to insert an expansion fitting once wiring has been set up and in service. In direct burial situations, expansion fittings are not needed because the ground has relatively constant temperatures. In cold areas, buried lines must be below the frost line to prevent buckling during freezing and thawing cycles. In warmer areas, the depth of cover protects against temperature extremes. Wire Inside the Conduit The coefficient of expansion for the wire inside the conduit is much lower than the nonmetallic conduit, therefore its length change due to expansion and contraction is very little. If the expansion fittings are mounted correctly, there should be little concern as to its effect on the wires inside.

Carlon Expansion Fittings Coupling End Part No. Male Terminal Adapter End Part No. Travel (in.) Std. Size Ctn. Qty. E945D E945DX 1/2 20 4" E945E E945EX 3/4 15 4" E945F E945FX 1 10 4" E945G E945GX 1 1 /4 5 4" E945H E945HX 1 1 /2 5 4" E945J E945JX 2 15 8" E945K E945KX 2 1 /2 10 8" E945L E945LX 3 10 8" E945M E945MX 31/2 5 8" E945N E945NX 4 5 8" E945P E945PX 5 1 8" E945R E945RX 6 1 8" E33447 Male Terminal Adapter End Coupling End ISEXPJT 0M 7/04 SP Lamson & Sessions 2004