1 P R O D U C T I N S TA L L AT I O N G U I D E POTABLE PIPING SYSTEM Designed Especially for Contractors BOW SUPERPEX JANUARY 2008
2
3 PRODUCT INSTALLATION GUIDE IMPORTANT NOTICE The information in this manual was gathered from publicly available sources, including reports of tests conducted by various independent entities under the test conditions specified in the standards listed. The contents of this manual are informational only. BOW has no responsibility for the design, administration, results, or evaluation of any test. BOW makes no warranties or representations, expressed or implied, as to: the fitness of any product or system for any particular purpose; the suitability of any product or system for any specific application; or the performance of any product or system in actual construction. No product or system should be used or installed without first reviewing all applicable plumbing or building code provisions and the manufacturer s installation instructions. Local code authorities and the product or system manufacturer should be consulted with respect to unresolved questions or uncertainties. Table of Contents Limitations on Pipe Use Flexible Pipe Installation Practices General Installation...3 Bending the Pipe Handling and Storing the Pipe Pipe Supports...4 Selection and Inspection...4 Support Spacing...4 Pipe Expansion and Contraction Connection to Other Piping Materials Hydrostatic Testing and Inspection of System Freezing and Thawing Pipe Systems...5 Insert Fitting System with Crimp Rings...6 Manifold Plumbing System...7 Technical Data Pipe Dimensions and Weights...8 Hydraulic Performance & Friction Losses Pressure Ratings Miscellaneous Data Appendix A
4 PRODUCT INSTALLATION GUIDE Limitations on Pipe Use Do not use in any application where pipe will be exposed to direct sunlight. Store pipe under cover prior to installation where it will not be exposed to direct sunlight. Do not allow the tubing or fittings to come into contact with materials that could affect the integrity of the SUPERPEX or fitting materials. This would include at least: * Pipe thread sealing compounds * Firewall penetration compounds (exception: water soluble gypsum based caulking) * Petroleum-based materials or sealants such as: Kerosene Benzene Gasoline Solvents Fuel Oils Cutting Oils Acetone Asphaltic Paint Asphaltic Road Materials Toluene Xylene Do not allow direct contact between high concentrations of termiticides or insecticides with PEX pipe. Backfill and cover underground tubing prior to spraying termiticide or insecticide. Do not place PEX pipe in contaminated soils or other contaminated environments. Situations calling for special scrutiny on a case-by-case basis would include (but not be limited to): * Tank farms or industrial sites containing chemical or petroleum storage tanks and pipelines where a malfunction or leak would contaminate the surrounding soil. * Storage ponds or land disposal sites for industrial process water or waste water containing toxic chemicals. * Solid waste disposal sites. * An area that has been known to be contaminated by the long-term presence of toxic chemical substances. * Strong chlorine solutions * Nitric and sulphuric acids * Ammonia * Surfactants A product absence from this list does not imply or insure chemical compatibility. Always check the product manufacturers recommendation in this regard. Use Only Copper or Brass Insert Fittings and Copper Crimp Rings (Coated Black) designed and identified as suitable for PEX 2
5 SUPERPEX january 2008 Flexible Pipe Installation Practices General Installation Review all limitations on the SUPERPEX pipe and fittings system you have selected to use before proceeding. Keep pipe a minimum of 12" vertically or 6" horizontally from sources of high heat, such as recessed light fixtures, flue gas vents, or heating appliances. SUPERPEX can be piped directly to the heater tapping on an electric hot water heater using metallic termination fittings. Do not directly connect hose bibbs to SUPERPEX tubing. Use a suitable metal fitting, and anchor it to prevent strain on the tubing. Bow permits the use of Bow SUPERPEX when connected to instantaneous water heaters or other hot water producing devices. However, consult manufacturers recommendations for use with plastic tubing and ensure temperature and pressure do not exceed the maximum ratings of the SUPERPEX tubing. Do not install SUPERPEX pipe downstream of any point -or- use water heater or immersed coil heater in a boiler where the output temperature can exceed 180 F or closer than 6 inches upstrem. When connecting to a gas hot water heater, at least 18 inches of a metal nipple or appliance connector should be used so that the SUPERPEX pipe cannot be damaged by the build-up of excessive radiant heat from the flue. Use only continuous lengths of pipe (no fittings) when installing under or within a slab. Make connections above the slab or in an access box. Protect pipe with non-metallic sleeves or tape where it penetrates a slab. Protect pipe from nail damage where appropriate. 3
6 PRODUCT INSTALLATION GUIDE Bending the Pipe SUPERPEX pipe may be bent to a maximum of 6 times the O.D. of the pipe, as shown in the table below. Pipe Size (CTS) Min. Bending Radius 3/8" 3.00" 1/2" 3.75" 3/4" 5.25" 1" 6.75" Note: If using pipe in coils and bending against the coil direction, the minimum bending radius is 3 times the radius given above, (e.g., 3/8 CTS pipe = 3 x 3" = 9") When joining, piping must be installed without placing stress on the joint. See illustrations that follow for appropriate methods of stress relieving. Handling and Storing the Pipe Do not drag the pipe over rough terrain, rocks, or any surface which can cut, puncture, or excessively abrade the pipe wall. Do not install kinked pipe. Inspect all pipe before and after installation. Cut out and replace all damaged sections. Store pipe under cover prior to installation where it will not be exposed to sunlight. Do not use fittings unless designed specially for SUPERPEX and BOW OXYPEX tubing. Look for PEX marking on all fittings and rings. Pipe Supports Selection and Inspection Plastic hangers and straps are recommended, but metal supports which are designed for use with plastic pipe can be used. Supports must not pinch or cut into the pipe, and should allow lateral movement. Supports must not have sharp edges that would result in abrasion during lateral movement. Inspect all supports prior to installation to ensure that sharp edges do not exist that can damage the pipe. Never use defective or damaged supports. Replace them. Support Spacing Spacing between supports is the same up to 1" CTS. Maximum spacing is as follows: Horizontal: 32" Vertical: 48" Additional Support Use protective sleeves or bushings on pipe: * When penetrating floors. * At beginning and end of straight runs of piping which penetrate studs or joists. * At significant changes in direction. 4
7 SUPERPEX january 2008 Pipe Expansion and Contraction SUPERPEX pipe expands approximately 7.9 x 10-5 in/in F or about 1" per 100 feet of length for every 10 F temperature rise. Therefore do not pull SUPERPEX pipe tight during installation so as to prohibit pipe movement, as this will result in unnecessary stress being placed on fittings and connections when pipe cools and contracts. Allow about 1/8" slack per foot of installed pipe. Expansion can usually be accommodated by pipe s flexibility for sizes up to and including 1" diameter pipe. For long lengths, a fourelbow expansion loop of continuous pipe loop will accommodate large expansion within a small space. Connection (Transition) to Other Piping Materials Using lead free solder, join copper piping transition fittings onto the copper pipe and allow to cool before connecting to PEX pipe. Otherwise the heat may damage the PEX pipe. When making connection to CPVC pipe or fittings, use only approved mechanical joints. Do not apply lubricants, pipe dope, or any chemical to an insert fitting. Hydrostatic Testing and Inspection of the Completed System Test all installations with ambient temperature potable water. A test pressure should be at least 100 psi, but not greater than 225 psi. A test duration of 2 hours is recommended. Do not use soap or detergent solutions for leak detection. Air testing shall be permitted only when water is not available or when cold weather could freeze the system. Under this circumstance, test the system to a maximum of 100 psi for 2 hours without a drop in air pressure. Air tests shall include appropriate safety precautions such as: * Conduct test overnight or on eekends, when job attendance is minimized. * Personnel should wear eye protection. * Warning Signs. * Protect pipe in areas where impact could occur while an air-test is in progress. Freezing and Thawing Pipe Systems SUPERPEX pipe systems should never be intentionally subjected to freezing. Freeze protection is a basic element for good plumbing and is a code requirement. Do not use open flame or excessive heat to thaw SUPERPEX pipe. Pipe failure or damage are likely results. Several suitable methods exist to thaw SUPERPEX pipe. They are listed below. * Commercial system which pumps heated water through a tube to the ice blockage, and returns the cooled water for reheating * Wet hot towels * Hot water * Hand-held hair dryer * Low wattage electrical heating tape 5
8 PRODUCT INSTALLATION GUIDE Insert Fitting System with Crimp Rings Making a Connection Insure that fittings and rings to be used are identified as being for use with PEX tubing. Cut tubing squarely, remove burrs, and slip the crimp ring on the tube. Check each crimped ring with the proper gauge. Slip gauge squarely over the crimped ring. Check in at least two positions. The GO portion of the gauge should slip over the ring. If not, the ring is under crimped. For gauges with NO-GO dimensions, the NO-GO gauge should not slip over the ring. Insert a PEX fitting into tube up to the fitting shoulder and position the crimp ring 1/8" to 1/4" from end of pipe. To prevent ring from moving, squeeze the ring slightly with your fingers or a pair of pliers. Fit must be snug. Center the crimping tool exactly over the ring, and keeping both the ring and the tool square with the tube, close the tool completely. Joints that do not pass the gauge check must be cut out and replaced. DO NOT RECRIMP (Double Crimp) THE SAME FITTING. Incorrect Connection The following are some examples of improper connections that may result in improper sealing and potential for leaks. 1) Ring crimped over the end of tube. 2) Tool not fully closed - ring not fully crimped. 3) Tool not centered on ring. 4) Tube not cut squarely. 5) Ring too far from tube end. Tools and Rings Use tools available from BOW. All tools must make a full-circle crimp. Check tool adjustment daily, and readjust as necessary. Use only copper crimp rings intended for PEX. 6
9 SUPERPEX january 2008 Manifold Plumbing System The following information applies to the Multi-flex Manifold system in addition to the general limitations and installation information on SUPERPEX pipe and fittings in this manual: Tubing shall be run continuously and as directly as possible between fixture and manifold locations. Tubing shall not be pulled tight. Leave slack to allow for expansion and contraction. Install tubing cautiously to avoid binding, kinking or abrasions of pipe. Leave excess tubing at the beginning and end of runs for connection to fixtures and manifolds. When running lines to a group of fixtures, they may be bundled together, but must be bundled loosely enough to allow individual pipe movement. Bundle hot and cold waterlines separately. Plastic ties may be used. Do not use tape when bundling pipe as it may restrict movement of an individual pipe run. When bundled lines pass through conventional structural members, cut hole at centerline of member. Consult code for maximum size hole permitted. Identify and permanently mark all lines at manifold for ease of installation, testing, and repair. 7
10 PRODUCT INSTALLATION GUIDE Technical Data DIMENSIONS OF PEX SDR 9 PLUMBING PIPE Size (Nom.) O.D. (in.) I.D. (in.) Wall Thickness (in.) 1/ / / / / Weights and Capacities of Plumbing Pipe (per 100 feet) Size (Nom.) Wt. empty (lbs.) Wt. full (lbs.) Capacity (U.S. gal) 1/ / / / / Metal Insert Fittings Equivalent Lengths Fitting Equivalent Length of Pipe (ft.) Type of Fitting 3/8" Size 1/2" Size 3/4" Size 1" Size Coupling Adapter Elbow Tee-Branch Tee-Run plastic Insert Fittings Equivalent Lengths Fitting Equivalent Length of Pipe (ft.) Type of Fitting 1/2" Size 3/4" Size Coupling Elbow Tee-Branch Tee-Run Hydraulic Performance & Friction Losses 8 Tubing Flow Rate (USGPM) Velocity (ft/s) 3/8 1/2" 3/4" 1" 1-1/4" F. Loss (psi/100 ft) Velocity (ft/s) F. Loss (psi/100 ft) Velocity (ft/s) F. Loss (psi/100 ft) Velocity (ft/s) F. Loss (psi/100 ft) Velocity (ft/s) F. Loss (psi/100 ft) PEX SDR 9 TUBING
11 SUPERPEX january 2008 PRESSURE RATINGS SUPERPEX and OXYPEX carry the following pressure ratings: F F F THERMAL CONDUCTIVITY 2.9 Btu in/hr. ft2 F Miscellaneous Data Formula Hazen Williams (Pressure Loss) Q 1.85 F = 4.52 C 1.85 d 4.87 Where F = Friction loss (psi/ft) Q = Flow rate [gal (U.S.) / min] C = Hazen Williams friction factor (150 for PEX) d = tube inside diameter (inches) Capacities Heat capacity of water (approximate) 1 Btu / lb. F [ 500 Btu / gal (U.S.) F ] Conversions 1 inch = 2.54 cm = 25.4 mm 1 foot =.305 m 1 lb. = 454 g 1 psi = 6.89 kpa = 2.31ftH20 1 Btu/hr =.293 W 1 gal (U.S.) =.832 gal (lmp) = 3.79 L 9
12 PRODUCT INSTALLATION GUIDE Appendix A Bow SUPERPEX Systems conform to the following: BOCA ICC BOCA National Plumbing Code International Plumbing Code IAPMO Uniform Plumbing Code SBCCI CABO Standard Plumbing Code 1 & 2-Family Dwelling Code ASTM American Society for Testing & Materials, STD F876, F877, F1807, F2159, F2023 NSF NSF International (SUPERPEX Tubing bears the NSF-pw, cnsf-pw and the NSF CL-R marks) CSA Canadian Standards Association (CSA B 137.5) 10
13 SUPERPEX january 2008 N O T E S 11
14 PRODUCT INSTALLATION GUIDE N O T E S 12
15
16 MONTRÉAL, QUÉBEC Tel.: (514) Fax: (514) CHAMPLAIN, NY Tel.: (800) Fax: (800) PEX INST-E JANUARY 2008
Engineering Specifications
PUREFLOW PEX PRODUCTS PART 1 GENERAL 1.1 SUMMARY 1.1.1 This specification covers Branch & Main, Parallel Water Distribution Systems (MANABLOC), Cross-linked Polyethylene tubing and fittings using PEX Press
Zurn PEX Plumbing Design and Application Guide. Zurn PEX Tubing and Fittings. Certified
Zurn PEX Tubing and Fittings Certified Notice: This manual contains recommended installation instructions for Zurn PEX hot and cold water systems. Failure to observe these installation instructions may
PEX TUBING FAQ WHAT IS PEX?
PEX TUBING FAQ WHAT IS PEX? Pex is cross-linked polyethylene. Through one of several processes, links between polyethylene macromolecules are formed to create bridges between PE molecules (thus the term
OUTLINE. How PEX pipes are made Capabilities of PEX pipes, standards, testing PEX pipes for Plumbing and other applications
PEX Pipes for Plumbing Presented at the 40 th ASPE Convention, Oct 2004 Lance MacNevin, Chair, PPI High Temperature Plastics Division Camille George Rubeiz, P.E., Director of Engineering, PPI OUTLINE How
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
PEX Pipes for Plumbing Applications
PEX Pipes for Plumbing Applications Introduction How PEX pipes are made Reasons for using PEX systems Industry standards and tests PEX joining systems Code acceptance Design considerations Installation
Introduction...3. Types of Plumbing Systems...4. Dos and Don ts for SharkBite PEX Tubing...9 Cross Linking Methods...10 Installation Tips...
Table of Contents Introduction...3 Features and Benefits of SharkBite Tubing Features and Benefits of SharkBite push-fittings Features and Benefits of Clamp/Barb Systems Types of Plumbing Systems...4 Truck
Chapter 7 Plumbing Connections
Chapter 7 Plumbing Connections 7-1 General All plumbing equipment and installations must be designed, constructed, and installed in accordance with this code and where not specific, to the applicable provisions
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS
DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible
NFPA31FuelOilPiping 1 Revised 3-1-11
NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
PEX Pipes for Service Line Applications
PEX Pipes for Service Line Applications Introduction to PPI Introduction to PEX pipes for water service Industry standards and tests Reasons for using PEX pipes for water service PEX installation for water
What to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
PLBG/GAS SAFETY Information Bulletin
PLBG/GAS SAFETY Information Bulletin November 2012 P/G-08-02-PLBG/GAS [Rev 3] Page 1 of 11 SUBJECT: REQUIREMENTS FOR COMBINATION HEATING SYSTEMS: DUAL PURPOSE WATER (POTABLE) HEATER (COMBO UNIT) Safety
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information
When Should Examination Preparation Begin?
Texas State Board of Plumbing Examiners Tradesman Plumber-Limited Licensee Examination Review Course The following Examination Review Course is designed to assist a registered Plumber s Apprentice in preparing
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations
SunMor SM-V30 Solar Water Heater Installation Manual
SunMor SM-V30 Solar Water Heater Installation Manual Rev. 1.02 Congratulations on the purchase of your new SunMor SM-V30 from Nature s Comfort LLC! You must read this entire instruction manual before beginning
HVAC Super Pro FAQ. Can HVAC SUPER PRO be used on both hard and soft copper and aluminum tubing?
HVAC Super Pro FAQ Application What is the working time for HVAC SUPER PRO? HVAC SUPER PRO can be left on the tubing and connector for several minutes, but when the tubing is inserted into the connector
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.
Recommend Approval: Team Leader Date Division Chief Date Approved: Director Date Maryland Department of Transportation State Highway Administration Office of Materials Technology MARYLAND STANDARD METHOD
STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
BASIC PLUMBING. 2 - Preparation. The simple skills required for basic plumbing are explained in this project.
BASIC PLUMBING The simple skills required for basic plumbing are explained in this project. It helps to have some metalworking experience. Take care when working with a blowtorch in loft spaces. Be aware
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division
Brian Coppock, Regional Compliance Officer Office of Statewide Health Planning and Development Facilities Development Division CHAPTER 6 WATER SUPPLY AND DISTRIBUTION 601.0 Hot and Cold Water Required.
Zurn PEX Chlorine Resistance PEX 5006 Designation Generally a continuously circulating hot water plumbing loop @ 140 F.
The Zurn PEX Commercial Plumbing System This manual is an addendum to the Zurn PEX Plumbing Installation Guide, ZPM07199. Its purpose is to provide customers with addi - tional information relevant to
FIBERGLASS UNDERGROUND STORAGE TANKS Special Installation Instructions for New York City Gasoline and Diesel Motor Fuels
INTRODUCTION The purpose of this manual is to provide speci c, detailed supplemental instruction regarding the installation of special Fiberglass Double-Wall Underground Storage Tanks (including compartment
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:
3M Water Filtration Products Installation and Instruction Manual For: CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings Installer: Please leave this manual with owner/operator. Owner/Operator:
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion
Socket Heat Fusion Techniques A Guide for Instruction and Training in Vanguard Socket Heat Fusion TABLE OF CONTENTS This brochure has been developed to assist those responsible for socket fusion joining
INSTALLATION INSTRUCTIONS BL-8704
INSTALLATION INSTRUCTIONS BL-8704 EXPOSED BLACK LEVER THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1
INSTALLATION INSTRUCTIONS MK-8704
INSTALLATION INSTRUCTIONS MK-8704 EXPOSED MACKINTOSH THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1
INSTALLATION INSTRUCTIONS. SharkBite. Connection System. The SharkBite System
INSTALLATION INSTRUCTIONS SharkBite Connection System The SharkBite System The SharkBite connection system uses an advanced push-fit design that works in two stages. When the tube is inserted into the
Top 10+ Mistakes of DWV plumbing design
Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of
with installation dynafact boost GAUGE this manual is for use with systems 64050-64054
owners manual with installation instructions dynafact boost GAUGE this manual is for use with systems 64050-64054 GENERAL INSTALLATION PRACTICES This manual is an installation guide for all 1. Banks DynaFact
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
SIZING OF WATER PIPING SYSTEM
SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL E101.1 Scope. E101.1.1 This appendix outlines two procedures for sizing a water piping system (see Sections E103.3 and E201.1). The design procedures
Draft Specification PEX tubing. Section 23 83 16. Radiant-Heating Hydronic Piping. (Roth Radiant Heating Systems)
This draft specification is for hydronic radiant heating systems using PEX tubing in slab, floor, wall and ceiling applications, and as distribution piping. Roth Industries supplies these systems under
Installation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
Application Data Important Safety Information
Application Data Important Safety Information Read this page before using any of the information in this catalog. This catalog is designed to be used as a guide in selecting the proper hose for the applications
SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE
1 Which tool is used to correct internal hi-low when preparing a 4-in. steel pipe for welding? A. 4-in. grinder with cutting disc. B. Mini-grinder with flapper disc. C. Pencil grinder with cone stone.
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
THE PUSH-FIT SOLUTION FOR PLUMBING AND HEATING SYSTEMS
THE PUSH-FIT SOLUTION FOR PLUMBING AND HEATING SYSTEMS Speedfit Fittings are suitable for use with copper pipe. Included in this leaflet: Product Guide Trade Tips How Speedfit Works Making a Good Connection
All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.
DIVISION 15 MECHANICAL SECTION 15100 - PLUMBING PART 1 - GENERAL SCOPE Plumbing work includes all domestic water, gas, and sanitary sewer systems as shown on plans. Also all fixtures and equipment which
Geyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
Recommended Fuel Piping Specification For UPP Piping, UL-971
Recommended Fuel Piping Specification For UPP Piping, UL-971 1.0 General The primary delivery piping system shall be for suction or pressure applications and have semi-rigid coaxial type double wall construction,
AMX300 DirectConnect Mixing Valve Kits
AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates
One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty
One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by: Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions
Cold Weather Concrete Practices
Cold Weather Concrete Practices The Information below is an outline of common practice for residential foundation placement and winter construction utilize Edmonton and surrounding Area. Conditions in
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
2006 Codes. Please verify the following before calling for inspection
INSPECTION CHECKLIST RESIDENTIAL PLUMBING ROUGH IN 2006 Codes This checklist is intended for use to prepare for an inspection. This is only a general list and is not intended to address all possible conditions.
Installation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
Plumbing Installation Manual
Plumbing Installation Manual Revised 4/6/2016 Table Of Contents Visit our website for the most current information. PEX Design Guide...4 Introduction...5 NIBCO PEX Pipe Process...5 A Complete System...5
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for cleaning and lining existing cast iron and ductile iron water mains
CHAPTER 11 STORM DRAINAGE
CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be
Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503
1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix
Freezing and Bursting Pipes. How pipes freeze and burst, and what to do to prevent damage.
Freezing and Bursting Pipes How pipes freeze and burst, and what to do to prevent damage. When water freezes, it expands. That s why a can of soda explodes if it s put into a freezer to chill quickly and
Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls
Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre-insulated Pipe Systems
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
PLUMBING ROUGH IN INSPECTION
This Program is made Possible through the Code Officials Education & Training Fund. Revenue for the Fund comes from Assessments on Building Permits. Please turn down cell phones and put pagers on vibrate.
CHAPTER 11 STORM DRAINAGE
CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,
HOT & COLD WATER PLUMBING SYSTEMS INSTALLATION GUIDE
HOT & COLD WATER PLUMBING SYSTEMS INSTALLATION GUIDE Designed Especially for Contractors $5.00 IMPORTANT NOTICE Bow FlowGuard Gold CPVC Systems are designed to be installed according to the local plumbing
Multiport Spill Containment with Defender Spill Containers
Multiport Spill Containment with Defender Spill Containers Retrofit Installation Guide Overview Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608
PEX Installation Manual
PEX allation Inst nual Ma Table of Contents Table of Contents...2 What Is PEX? Why Use PEX?...2 What You Might Need...3 Tools...4-9 Fittings...0-2 PEX Tubing...3-5 Plumbing Systems...6-7 Manifolds...8
TubeTrace, ThermoTube
TubeTrace, ThermoTube and Custom CEMS Tubing Bundles INSTALLATION PROCEDURES English Units TubeTrace & ThermoTube Tubing Bundles Receiving, Storing and Handling... 1. Inspect materials for damage incurred
Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996
CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH. 10 40 BLACK & GALVANIZED STEEL PIPE
FASTLOCK fittings are not currently approved for use with gas or fire protection applications. FITTINGS FOR STEEL PIPE LIST PRICE BOOK MALLEABLE CAST IRON FITTINGS FOR SCH. 10 40 BLACK & GALVANIZED STEEL
Specifications for Residential Property Owners Connection to New Public Sewer
Specifications for Residential Property Owners Connection to New Public Sewer Spalding Tract property owners are required to connect to the community sewer system when construction is complete and the
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide
*PATENT PENDING NS1100 / NS2200 Installation Manual & Owner s Guide Installation Tips Contents 1 Control Panel 1 Spool of Signal Wire 2 Mounting Screws & Drywall Inserts 2 Wire Clips 3 Wire Ties Tools
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215
0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted PMG 1057 Valid: 02/15 to 02/16 DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING
Pipe Protection Tape System
Pipe Protection Tape System PASCO All Weather Pipe Protection Tape is a pure physical barrier that is moisture proof, inert and non-conducting. Whether the need is to protect overhead piping in industrial
Saving Water and Energy in Residential Hot Water Distribution Systems. Gary Klein California Energy Commission
Saving Water and Energy in Residential Hot Water Distribution Systems Gary Klein California Energy Commission What Do You Want from your Hot Water System? Safety Not too hot Not too cold No harmful bacteria
Arapahoe County Residential Water Heater Installation and Inspection Guide
Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however
SANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L
T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L AT I O N I N S T R U C T I O N S C A R E F U L LY CAR
W I T H I N J O I ST S I N STA L L AT I ON
Radiantec W I T H I N J O I ST S I N STA L L AT I ON I N S TA L L AT I O N S U P P L E M E N T 260 Joists When tubing is placed beneath a joisted floor system, it is weaved between the joists and supported
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft