Catalogue Wilo- Stratos PARA



Similar documents
Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO-D

Heating, air-conditioning, cooling

Series description: Wilo-Star-Z

Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX Q [US gpm]

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Series description: Wilo-Drain TC 40

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Type overview. Technical data

HYDRUS ULTRASONIC METER

Multistage high-pressure multistage centrifugal pumps

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

HERZ-Thermal Actuators

LC/LCD ranges level controllers

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Assisted lift operated 2/2-way solenoid valves Type EV250B

Series 6000 Torque measured metal bellow coupling

Photovoltaic Solar Energy Unit EESFB

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Overview of types. Technical data

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

PCS0100en Persy Control Services B.V. Netherlands

Voltage Regulator SPAU 341 C. Product Guide

Liquid Level Limit Switch liquiphant T FTL 20

Three-phase monitoring relay CM-PFE

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Laing industrial pumps

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

4 Posiflow Proportional Solenoid Valves

Safety at a high level!

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ST Series POWER SUPPLIES USER INSTRUCTIONS

Safety technique. Emergency stop module BO 5988 safemaster

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

WVC300 Micro-inverter solar grid system (Power line communications)

Butterfly Valves PN 6/10/16 for flanged connection

AMTRON E-30 Compact heat and cooling meter

Electronic Pressure Switch EDS 300

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

48 SERIES Relay interface modules 10 A

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Digital input modules

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

ACS-30-EU-EMDR-10-MOD

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

49 Series - Relay interface modules A. Features

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

BITMAIN. APW PSU Series User Guide

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

ECOCIAT. Domestic hot water heat recovery unit

Power Thyristor TS3 (SP) 3ph. Installation Guide

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Submittal Data Sheet Wilo IPL - Inline Centrifugal Circulators

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

RS - SPM. Serial parallel translator module

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Antec TruePower User's Manual

How To Use A Flowmeter

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Talon and Talon SR User Manual

Combi switchbox with integrated 3/2 way pilot valve

CRN A-F-G-E-HQQE 3x400D 50 HZ

Safety automation solutions

Transformerless PV inverter withstandardsystem monitoring. Fronius IG TL

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Conlift1, Conlift2, Conlift2 ph+

Number 1 in efficiency

Type: DILM32 10(24V50HZ) Article No.:

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Thermistor motor protection

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

LED control gear. LED control gear

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Series 7500 Torque Sensor

Cable Plug acc. to DIN EN , Form A

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

GLYDEA TM DIRECT DRIVE MOTORIZED CURTAIN TRACK SPECIFICATION DOCUMENT

Preset Counter signo 721

Transcription:

Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos PR 15/1-11,5; 20/1-11,5 Wilo-Stratos PR 25/1-8; 30/1-8 Wilo-Stratos PR 25/1-11; 30/1-11 Wilo-Stratos PR 25/1-12; 30/1-12

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Equipment/ Function Operating modes Control mode (n = constant) p-c for constant differential pressure p-v for variable differential pressure Manual functions djustment of operating mode djustment of differential-pressure setpoint utomatic functions Stepless performance adaptation as a function of operating mode Deblocking function Soft start Full motor protection with integrated trip electronics External control functions Control input "nalog In 0... 10 V" with cable brack funktion (remote speed setting) Control input "nalog In 0... 10 V" without cable brack funktion (remote speed setting) Control input PWM Signal and display functions Collective fault signal SSM (floating normally closed contact) Individual run signal SBM (floating normally opened contact) Equipment/scope of delivery Wrench attachment point on pump body Incl. seals for threaded connection (loose) Incl. installation and operating instructions Incl. thermal insulation for Heating Inkl. ClimaForm for Cooling 15/1-5 20/1-5 25/1-5 30/1-5 15/1-7 20/1-7 25/1-7 30/1-7 Wilo-Stratos PR 15/1-11,5 20/1-11,5 25/1-8 30/1-8 25/1-11 30/1-11 25/1-12 30/1-12 (Hmin=1m, Hmax=5m) (Hmin=1m, Hmax=7m) (Hmin=4m, Hmax=10m) (Hmin=1m, Hmax=7m) (Hmin=2m, Hmax=10m) (Hmin=2m, Hmax=11m) (Hmin=1m, Hmax=5m) (Hmin=2m, Hmax=6m) (Hmin=4m, Hmax=10m) (Hmin=2m, Hmax=7m) (Hmin=4m, Hmax=10m) (Hmin=4m, Hmax=10m) = available = not available o = optional = on request technical changes reserved

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Technical Data Heating water (as per VDI 2035) Water/glycol mixtures (max. 1:1; mixtures with more than 20 % glycol content require rechecking of the pumping data) Domestic hot water for secondary and service water systems in accordance with German directive TrinkwV 2001 15/1-5 20/1-5 25/1-5 30/1-5 15/1-7 20/1-7 25/1-7 30/1-7 Wilo-Stratos PR 15/1-11,5 20/1-11,5 25/1-12 30/1-12 Stratos PR- Z Performance Max. delivery head [m] Max. flow rate [m3/h] Speed range [rpm] Permitted field of application Temperature range for use in heating, ventilation and /C systems 5 3,2 1200-3700 7 4,5 1200-4450 12 1,4 1200-4450 8 8 1400-3900 11 4,5 1400-4850 12 10 1400-4800 at max. ambient temperature +25 C [ C] at max. ambient temperature +40 C [ C] at max. ambient temperature +50 C [ C] Temperature range for use in drinking-water circulation systems at max. ambient temperature +40 C [ C] -10 to +95-10 to +95-10 to +15-10 to +110-10 to +90-10 to +15-10 to +110-10 to +90-10 to +15 Max. permitted total hardness in drinking-water circulation systems [ d] Standard version for operating pressure pmax [bar Special version for operating pressure pmax [bar] Pipe connections 6 6/10 6/10 Screwed connection Rp 1/2 3/4 1 1 1/4 1/2 3/4 1 1 1/4 1/2 3/4 1 1 1/4 1 1 1/4 1 1 1/4 Nominal connection diameter DN 15 20 25 30 15 20 25 30 15 20 25 30 25 30 25 30 Electrical connection Mains connection 1 ~ [V], standard version Mains frequency [Hz] Motor/electronics Starting current, [] Standby-Power consuption, W Electromagnetic compatibility Emitted interference Immunity to interference Power electronics Protection class Insulation class Materials Pump housing 230 50/60 < 20 for 8ms 1,44 EN 61800-3 EN 61000-6-3 EN 61000-6-2 Frequency converter IP44 H Gray cast iron (EN GJL 200) 230 50/60 <= 30 for 10 ms 1,44 EN 61800-3 EN 61000-6-3 EN 61000-6-2 Frequency converter IP44 H Gray cast iron (EN GJL 200) 230 50/60 15-20 for 10ms 1,44 EN 61800-3 EN 61000-6-3 EN 61000-6-2 Frequency converter IP 44 H Gray cast iron (EN GJL 200) Impeller plastic (PPS- Noryl 1630 V (PPE/PS) 40%GF) Plastic (PPE) glass fiber reinforced PPS 25/1-8 30/1-8 25/1-11 30/1-11 Stratos PR-Z Shaft Stainless steel (X46 Cr13) Stainless steel (X46 Cr13) Stainless steel (X46 Cr13) Bearing Minimum suction head at suction branch [m] for avoiding cavitation at water delivery temperature Metal- impregnated carbon Metal- impregnated carbon Metal- impregnated carbon 50 C 3 3 3 3 3 95 C 10 10 10 10 10 110 C - - - 16 16 = available = not available * = infotmation at deadline was not availible technical changes reserved

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Duty Graph (n = max.) Motor Data Stratos PR 15/1-5 Stratos PR 20/1-5 Stratos PR 25/1-5 Stratos PR 30/1-5 Stratos PR 15/1-7 Stratos PR 20/1-7 Stratos PR 25/1-7 Stratos PR 30/1-7 Stratos PR 15/1-11,5 Stratos PR 20/1-11,5 Stratos PR 25/1-8 Stratos PR 30/1-8 Stratos PR 25/1-11 Stratos PR 30/1-11 Stratos PR 25/1-12 Stratos PR 30/1-12 Rated power Speed Power consumpt. Current at 1~230V Motor protection P2 n P1 l - [W] [1/min] [W] [] - 25 1200-3700 4-38 0,06-0,33 integrated 50 1200-4450 5-70 0,06-0,58 integrated 50 1200-4450 4,5-72 0,1-0,69 integrated 100 1400-3900 8-140 0,09-1,30 integrated 105 1400-4850 7-140 0,06-1,20 integrated 200 1400-4800 16-310 0,16-1,37 integrated technical changes reserved

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Duty Graph WILO-Stratos PR 15(20)(25)(30)/1-5 p-constant p-variable WILO-Stratos PR 15(20)(25)(30)/1-7 p-constant p-variable

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Duty Graph WILO-Stratos PR 25(30)/1-8 p-constant p-variable WILO-Stratos PR 25(30)/1-11

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Duty Graph WILO-Stratos PR 25(30)/1-12

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Electrical Connection Pin assignment - Connector is encoded! - 3-lead cable for 230V/50Hz C power supply, earth connected - 4-lead cable for 0-10V and SSM - 2-lead cable for PWM 1. Power supply: Black/brown: Blue: Green/yellow: 2. Control cable for 0-10V and SSM: Lead No 1 (brown): Lead No 2 (white): Lead No 3 (blue): Lead No 4 (black): 3. Control cable for PWM: Lead No 1 (brown): Lead No 2 (white): L1, 230V/C 50Hz Neutral N Protective earth 0-10V GND 0-10V Signal-characteristic below SSM contact (NC) SSM contact (NC) PWM GND PWM Signal-characteristic below - The following minimum requirements are to be met if a shutdown takes place by means of an onsite network relay: nominal current 10, nominal voltage 250 VC. - Leakage current per pump Ieff <=3,5 m (as per EN 60335) Possible combination of the functions and equipment: Type of pump Stratos PR Stratos PR Stratos PR P2=25-200 W P2<= 50W; 200 W P2=25-50 W Combination N 1 2 3 4 5 6 7 8 9 10 11 Operating modes Control mode (n = constant) p-c for constant differential pressure p-v for variable differential pressure External control functions Control input "nalog In 0... 10 V" with cable brake function Control input "nalog In 0... 10 V" without cable brake function Control input PWM 1 Control input PWM 2 Signal and display functions Collective fault signal SSM (floating NC contact) Individual run signal SBM (floating NO contact) Equipment Control Element "red Button" Power cable 4-lead cable for 0-10V and SSM/SBM 2-lead cable for PWM technical changes reserved

Heating, ir Condition, Cooling, Geothermal heat, Solar heat External control functions 0-10 V characteristic with cable brake function 0-10 V characteristic without cable brake function n[1/mi nmax nmin 0,5 1 2 3 10 U[V - input voltage < 1V: the pump stops - input voltage 1V<U<3V (running): the pump runs at min. speed - input voltage 2V<U<3V (starting): the pump runs at min. speed - input voltage 3V<U<10V: speed variation between n min and n max (linear) - input voltage <0,5V: cable break detected, emergency mode, the pump runs at min. speed PWM Signal frequency:100 Hz-5000 Hz (1000 Hz nominal) Signal amplitude:5v-15v (minimum curent 5m) Signal polarity:both PWM 1 PWM 2 Electrical Connection Start-Up Time Wilo-Stratos PR 15/1-5 20/1-5 25/1-5 30/1-5 15/1-7 20/1-7 25/1-7 30/1-7 15/1-11,5 20/1-11,5 25/1-8 30/1-8 25/1-11 30/1-11 25/1-12 30/1-12 Start-Up time : Power ON [sek] 0 to Min_Rpm 7 7 * 7 8 10 0 to Max_Rpm 7 7 * 7 8 10 Min_Rpm to Max_Rpm 3 4 * 2 3 5 Max_Rpm to Min_Rpm 3 4 * 5 6 * Start-Up time: Control input "nalog In 0... 10 V [sek] 0-10V ON : 0 to Max_Rpm 6 6 * 6 7 7 0-10V ON : 0 to Min_Rpm 1 1 * 2 3 * Start-Up time: Control input PWM, [sek] * * = infotmation at deadline was not availible

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Failure Matrix Failure Reaction time, tr Delay, ta llowed number of failures, n utoreset SSM SBM Comment line undervoltage 20ms 20ms unlimited yes open closed Off: 165V C / On: 195V C line overvoltage 20ms 20ms unlimited yes open closed Off: 265V C / On: 245V C blocked pump 10s 30s 5 no open closed lost of sync 10s 5s 25 no open closed overload motor 60s 30s 5 no open closed short circuit < 6µs 30s 5 no open closed I = 3 DC contact failure, winding failure <10s 30s 5 no open closed Dry running <60s 30s 5 no open closed overtemp. modul <1s 30s 5 no open closed Cable break on extern 0-10V <1s <1s unlimited no open closed Pump runs at minimum speed Definition of the reaction tim e 2 Tr = n * (tr + ta) State of the pump 0 = Failure occured 1 tr ta n tn 0-2 0 2 4 6 8 10 Tim e t Reaction time (tr) - Delay (ta) - time until failure is detected time until pump restarts uto reset - yes-> number of allowed errors has no limit -> -> software restarts pump after delay no -> number if allowed erros is limited -> -> interruption of mains is necessary to restart pump llowed failures - In case of limited allowed failures error counter will be reset, if no failure occurs within 2 minutes (tn). Otherwise after the maximum allowed errors is reached, the mains has to be interrupted to restart the pump.

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Failure Handling

Heating, ir Condition, Cooling, Geothermal heat, Solar heat Dimensions, weights/ Stratos PR 30-50 W b4 b5 l 1 l 2 a 3 l 0 l 3 a 2 a 1 Pipe connectio n Thread Pump dimensions Weight approx. Rp G l 0 a 1 a 2 a 2 l 1 l 2 l3 b 4 b 5 PN 6/10 [mm] [kg] Stratos PR 30/1-5 130 116 32 95 65 56 138 2,4 1 1/4 2 42 41 Stratos PR 30/1-7 180 116 32 94 90 56 138 2,4 Stratos PR 25/1-5 130 116 32 94 65 56 138 2,4 1 1 1/2 42 41 Stratos PR 25/1-7 180 116 32 94 90 56 138 2,4 Stratos PR 20/1-5 116 32 94 65 56 138 2,4 3/4 1 1/4 130 42 41 Stratos PR 20/1-7 116 32 94 90 56 138 2,4 Stratos PR 15/1-5 116 32 94 65 56 138 2,4 1/2 1 130 42 41 Stratos PR 15/1-7 116 32 94 65 56 138 2,4 Stratos PR 20/1-11,5 3/4 1 1/4 113 33 94 65 56 138 * 130 42 41 Stratos PR 15/1-11,5 1/2 1 113 33 94 65 56 138 * Dimensions, weights/ Stratos PR 100-200 W Stratos PR 25/1-8 Stratos PR 25/1-11 Stratos PR 25/1-12 Stratos PR 30/1-8 Stratos PR 30/1-11 Stratos PR 30/1-12 Pipe connectio n Thread Pump dimensions Weight approx. Rp G l 0 a 1 a 2 l 1 l 2 [mm] b 1 b 2 b 4 b 5 PN 6/10 [kg] 158 43 90 58,4 54 47,5 47,7 46,5 3,7 1 1 1/2 180 150 33,8 90 58,4 48 47,5 47,7 46,5 3,3 189 50 90 79 54 61 58 57 5,5 158 43 90 58,4 54 47,5 47,7 46,5 3,7 1 1/4 2 180 150 33,8 90 58,4 48 47,5 47,7 46,5 3,3 189 50 90 79 54 61 58 57 5,5 * = infotmation at deadline was not availible technical changes reserved