Transcutaneous Bilirubinometer



Similar documents
Suggested BiliChek Usage Protocol

D Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105

Sample Usage Protocol Jaundice Meter JM-105

CAROLINE S STORY. A real case demonstrating the unfairness of damage caps.

Hyperbilirubinemia in the Newborn Infant 35 Weeks Gestation: An Update With Clarifications

Clinical guideline Published: 19 May 2010 nice.org.uk/guidance/cg98

Jaundice in the Newborns

Prediction of the development of neonatal hyperbilirubinemia by increased umbilical cord blood bilirubin

Breastfeeding. Clinical Case Studies. Residency Curriculum

ASSESSMENT AND MANAGEMENT OF NEONATAL JAUNDICE IN THE FIRST TWO WEEKS OF LIFE NEONATAL CLINICAL GUIDELINE

D Next-generation LED phototherapy NanoBlu 500

9.Pediatric Procedures

UNIT: Total and Direct Bilirubin

Cat S O SSM. Services. Reporting Particle Count by ISO Code. Management Guide. Two methods of reading particles

Eyelid Surgery - Lower

Premature Infant Care

Effect of White Plastic Cover around the Phototherapy Unit on Hyperbilirubinemia in Full Term Neonates

Body Fat Scale Instructions for use

Why is prematurity a concern?

Critical Care Therapy and Respiratory Care Section

Hemoglobin detection kit Catalog # ADI

BiliCam: Using Mobile Phones to Monitor Newborn Jaundice

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Bilirubin (serum, plasma)

St Lucia Diabetes and Hypertension Screening and Disease Management Programs

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

Blood Glucose Monitoring: The Facts about Accuracy

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

MANAGEMENT OF DIRECT ANTIGLOBULIN TEST (DAT) POSITIVE INFANTS NEONATAL CLINICAL GUIDELINE

Three Key Paper Properties

PedsCases Podcast Scripts. Developed by Amarjot Padda, Chris Novak, Dr. Melanie Lewis and Dr. Bryan Dicken for

Wound Care Charge Process

Critical Congenital Heart Disease (CCHD) Screening

Using the Spectrophotometer

Neonatal Equipment Everything that you would like to know!

There are different types of lasers that according the wavelength of their beams have different indications; the most common ones used on skin are:

2 Spectrophotometry and the Analysis of Riboflavin

Quality-Based Procedures Clinical Handbook for Hyperbilirubinemia in Term and Late Pre-Term Infants ( 35 weeks)

How to measure Chlorophyll-a

The sensitive marker for glomerular filtration rate (GFR) Estimation of GFR from Serum Cystatin C:

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Futuristic Beauty. Buyers Guide

IOWA DEPARTMENT OF PUBLIC HEALTH CHILDHOOD LEAD POISONING RISK QUESTIONNAIRE

Delayed Cord Clamping

How babies' senses develop

New Methods for Guidance of Light-Based Treatments Using Objective Melanin Measurements

Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry

Operating Manual FINGERSIM SET /5.11. for SECULIFE NIBP in Combination with SECULIFE OX1

Corporate Medical Policy Laser Treatment of Port Wine Stains

Supporting Breastfeeding and Lactation: The Primary Care Pediatrician s Guide to Getting Paid

NICU Level of Care Criteria

Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Laparoscopic Gallbladder Removal (Cholecystectomy) Patient Information from SAGES

Pulse Oximetry. Principles of oximetry

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

Lab #11: Determination of a Chemical Equilibrium Constant

Figure S1. SDS-PAGE of purified rtmd proteins Figure S2. rtmd1 interferes with chemotaxis of HUVECs induced by rtmd23

EXERCISE 3: SKIN PUNCTURE ON INFANTS

Experiment 5. Lasers and laser mode structure

Accuracy and reliability of pulse oximetry in

Perinatal Symposium--2012

Forehead. Use and Care Manual. Thermometer IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Model V977

Resource Document 6: Tetanus Immunization. I. Introduction

EXERGEN. English. TemporalScanner TM. Accurate Temperature with a Gentle Forehead Scan. Operators Manual for TAT-5000

Issue date: May Neonatal jaundice. NICE clinical guideline 98 Developed by the National Collaborating Centre for Women s and Children s Health

Light in the Greenhouse: How Much is Enough?

Supplementary online appendix

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

NEONATAL CLINICAL PRACTICE GUIDELINE

The Heart Center Neonatology. Congenital Heart Disease Screening Program

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Introduction to Fourier Transform Infrared Spectrometry

Official reprint from UpToDate UpToDate

BACTERIAL ENUMERATION

Pneumatic tube systems in hospitals

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

School-age child 5-1 THE BLOOD

INTRAVENOUS FLUIDS. Acknowledgement. Background. Starship Children s Health Clinical Guideline

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

NNIN Nanotechnology Education

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Guy s, King s and St Thomas Cancer Centre The Cancer Outpatient Clinic Central venous catheter: Peripherally inserted central catheter

The Determination of an Equilibrium Constant

Characterization of a New Light and Vacuum Device for the Treatment of Acne

digital fever alert ear thermometer suitable from birth instruction manual

Density and Refractometry

GROUP MEDICARE SUPPLEMENT PLANS. S5753_081213_GB03_MN Internal Approval 08/13/2013

Abdominal Aortic Aneurysm (AAA) General Information. Patient information Leaflet

Acid-Base Balance and the Anion Gap

Nucleic Acid Purity Assessment using A 260 /A 280 Ratios

Gentle and safe injections. Tips and tricks for injecting insulin.

Self-Monitoring of Blood Glucose

Corporate Overview. April 2014 OTCQB: LCDX

Who Is Involved in Your Care?

Biochemistry Validation Form

Transcription:

Transcutaneous Bilirubinometer Neonatal jaundice occurs in nearly 70% of term and 80% of preterm babies. Management of jaundiced neonates often requires measurement of total serum bilirubin (TSB). Total serum bilirubin (TSB) is commonly determined by spectro-photometric methods by analyzing plasma or serum sample. Such techniques require drawing of blood causing pain and trauma to the neonate. In addition, there is a wide range of intra- and inter-laboratory variability in the performance of the bilirubin analyzers. These problems have led to search for a non-invasive, reliable technique for estimation of TSB. A large number of studies have demonstrated the possibility of prediction of serum bilirubin in neonates by measuring the yellowness of the skin in the jaundiced neonate using transcutaneous bilirubino-meters. Principle High correlation between cutaneous bilirubin and TSB form the basis of Transcutaneous Bilirubinometry. These meters work by directing light into the skin of the neonate and measuring the intensity of specific wavelength that is returned. The number of wavelengths, used is variable in different transcutaneous bilirubinometers. The meter analyzes the spectrum of optical signal reflected from the neonate s subcutaneous tissues. These optical signals are converted to electrical signal by a photocell. These are analyzed by a microprocessor to generate a serum bilirubin value. The major skin components, which impart the spectral reflectance in neonate, are (i) melanin, (ii) dermal maturity, (iii) hemoglobin, and (iv) bilirubin. Earlier, the transcutaneous bilirubinometers utilized only a few wavelengths. In these meters, there was no provision to overcome the impact of dermal maturity and melanin content. Therefore, separate analysis for each patient population (different ages and races) was required one had to refer to different conversion tables for each population. However, a new product, Bilicheck TM (Specter, Inc) performs a spectral analysis at more than 100 different wavelengths. By subtracting the spectral contribution of the known components, the bilirubin absorbance is quantified. The available meters can be divided into 2 categories: (i) Multi wavelength Spectral Reflectance meters (Bilicheck) TM (ii) Two-wavelength (460 nm, 540 nm) Spectral Reflectance meters (Minolta, Bili-test) 1

How do these meters report the results? The earlier transcutaneous bilirubino-meters reported the result in form of Transcutaneous Bilirubin Index (TcBI). The TcBI can be converted to bilirubin values in mg/dl or umol/ll by using different multiplication factors for different populations. Bilicheck TM, however, displays the results in clinically appropriate units: mg/dl or µmol/l. Basic operating procedure While each transcutaneous bilirubinometer has a different detailed operating procedure, the basic principle remains the same. The optic head of the meter is gently pressed against the neonates skin (usually forehead or upper part of sternum). For correct measurement, the optic head should make full contact with the skin and there should be no gaps between the head and the skin. This should be achieved by gentle pressure. Bilicheck TM differs from the other meters, in that, each time, 5 values are recorded at different sites in a neonate and then the result gets displayed. Site of measurement The commonly used sites are the forehead and the upper end of sternum. The meter readings for each site should be compared with the actual TSB before a particular site is chosen. The correlation coefficients for other sites such as the lower limbs are poor. Hyperemia at the test site may affect the results. Measurements against bruises, birthmarks and subcutaneous hematoma should be avoided. Advantages of Bilicheck TM over other meters (i) The measurements are accurate for newborn of all races and ages; therefore separate analysis/conversion table are not required for each population. (ii) It is optimized for measuring bilirubin in the venous plexus. (iii) The results are displayed in clinically appropriate units mg/dl or µmol/l. (iv) The instrument automatically calibrates with the BiliCal before each measurement. Other instruments are factory calibrated. (v) The optical tip (Bili-Cal ) has a small 0.5 cm platform ensuring proper skin/tip contact. Other equipment have a larger optical head. However, the disadvantage of Bili-check TM is the need for changing the tip (Bili-Cal) for each measurement. This adds to the cost of operation. 2

Clinical utility of Transcutaneous Bilirubinometers Often a pediatrician is interested to corroborate his clinical estimate of the icterus with actual serum bilirubin level. Any such technique should ideally be accurate, non-invasive and valid. A large number of studies have tested the agreement between transcutaneous bilirubinometer results and TSB. Most studies have found fair to excellent correlation between the two. However, the correlation is not an appropriate statistical technique for judging the agreement. Earlier instruments have been found more useful in whites and some other population; studies in India have not reported the same degree of agreement. While the correlation may be good, the difference between two values may be too large to be acceptable clinically. It appears that the difference between the transcutaneous bilirubin estimate and TSB may be too much to be acceptable. Also, once phototherapy is started for hyperbilirubinemia, these instruments have no utility. Despite these limitations, transcutaneous bilirubinometers can serve as a screening tool, especially where services of a neonatologist are not available. However, this cannot serve as a substitute for TSB estimations. Table 8.1: Common transcutaneous bilirubinometer available in the market S.No. Make Principals Dealers Cost 1. Airsheild s-minolta Hillrom-Airsheild s Drager Medical Rs. 1,00,000/- 2. Bilitest Technomedia Lacteromedik Rs. 1,20,000/- Pharmamen Enterprises 3. BiliCheck Spectrex Rustagi Surgicals, Phoenix Rs. 1,75,000/- 4. Ohmeda Datex- Ohmeda Phoenix Not launched Frequently asked questions (FAQ s) Q1. Why is there a need for transcutaneous bilirubinometry? Neonatal jaundice is a very common condition. Though benign in majority some need investigations and appropriate management. In such a situation, reliable, 3

non-invasive method of bilirubin estimation will certainly be of great help. Transcutaneous bilirubinometers attempt to achieve this. Q2. What is the principle of Transcutaneous Bilirubinometry? High degree of correlation between cutaneous bilirubin and TSB is the basis of transcutaneous bilirubinometry. Simply stated, transcutaneous bilirubinometer measures the yellowness of the skin by analyzing the spectrum of light reflected by the baby s skin. Q3. What is a multi reflectance spectral bilirubin meter? The major components which impart the spectral reflectance in neonates are: melanin, dermal maturity, hemoglobin and bilirubin. Most bilirubinometers analyze only a few wavelengths; as a result, the dermal maturity and melanin content would interfere with the result. With these meters, separate analyses for each patient population were required. To overcome this problem, multireflectance spectral bilirubin meter has been designed. This instrument perform spectral analysis at more than 100 different wavelengths and by subtraction of spectral combination of the known components, bilirubin absorbance is quantified. This technique eliminates need for different charts for different populations. Q4. What are the commonly used sites for estimation by these meters? Forehead and the upper end of sternum are the commonly used sites. Hyperemia at the test site may affect results. Measurement against bruises, birthmark and subcutaneous hematoma should be avoided. Q5. Does it matter, who is doing the measurement? Virtually all of the published studies performed with the Bilichek TM and the JM- 103 have been performed under the relatively rigorous conditions of clinical investigation, with TcB measurements obtained by research nurses or technicians. Such studies almost certainly provide more accurate and precise results than those obtained with real world measurements by many different nurses or physicians in different environments and in the course of a normal day s work. 4

Q6. Do these instruments have any ongoing costs? For Bilicheck TM, the tip (Bili-cal) needs to be replaced for each new measurement, which adds to the cost of operation. Other meters do not require this tip. Q7. In what unit are the readings of these instruments? Bilicheck TM gives the reading in mg/dl. However other meters Twin wavelength spectral reflectance meters give reading in form of transcutaneous bilirubin index (TcBI), which then has to be converted to value in mg/dl by using available formulae/chart. Q8. How sensitive and specific are the bilirubin estimations by Transcutaneous Bilirubinometer? Most of the studies performed on older bilirubinometer, have used correlation as the statistical technique; they reported various degrees of correlation. In a study at AIIMS, using Bilicheck TM, the sensitivity and specificity of the meter to pick up bilirubin >13 mg/dl was 69% and 89.3% respectively. However, the sensitivity was lower at higher cut offs (Indian Pediatr 2000; 37: 771-775) Q9. What is the clinical utility of transcutaneous bilirubinometer? Are these useful as screening tools? Presently available instruments are not sufficiently sensitive and specific to replace TSB measurement. The difference between transcutaneous bilirubin estimate and TSB appears to be too large to be acceptable. However, transcutaneous bilirubinometers can serve as screening tools, especially where services of a neonatologist are not available. 5