Criteria for Selecting a Residual-Current Device



Similar documents
Medium-voltage Transformers

SUNNY TRIPOWER 5000TL 12000TL

Technical Information Short-Circuit Currents Information on short-circuit currents of SMA PV inverters

PROTECTION AGAINST ELECTRIC SHOCK by John Ware

Sunny Family 2012 PRODUCT CATALOG

Firmware Update with SD Card SUNNY BOY WINDY BOY SUNNY TRIPOWER

Electrical safety requirements in DC distribution systems

SMA Bluetooth. Content. SMA Bluetooth Wireless Technology in Practice. Further Documents on SMA Bluetooth

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Electrical safety. in control and auxiliary circuits. Safety objectives

Roy Allen, Technical Training, 17FEB2015 ABB Solar Days Residential Products, Design & Application Rapid Shutdown. ABB Feb 27, 2014 Slide 1

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Insulation resistance

Ground Fault Protection

Planning Guidelines SMA FLEXIBLE STORAGE SYSTEM WITH BATTERY-BACKUP FUNCTION

Residual Current Circuit Breaker

Three phase connection

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Technical guide Protection against earth faults with Residual Current Devices

Advisory Guide. Decentralized Inverter Technology in Large-Scale PV Plants. String inverters. Technical Information Edition1.1 BL-DezWT-UEN103511

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

Solar-Bau Elisabeth Str Gorlitz 056/651/25124 USt-IdNr: DE

Inverters. The product range.

Designing PV Plants Optimised for Economic Efficiency

5SV Residual Current Protective Devices

How can a charging station for electric vehicles be set up simply and safely?

ABB central inverters PVS to 1000 kw

Digital Pressure Measuring Instrument MDR480

SUNNY BOY 2000HF / 2500HF / 3000HF

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2

How To Understand The Electrical Power Supply Of A Power Supply System

ADM1TE 5/30A DIN rail single phase two wire energy meter

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS RESIDUAL CURRENT DEVICES

Technical Information Requirement for MV transformers and transformer for internal power supplies for SUNNY CENTRAL

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

RELAYS Solar Energy Systems

PV Inverter SUNNY TRIPOWER 8000TL/10000TL/12000TL/15000TL/17000TL

Checklist Testing and inspection without interconnection

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Guide to the Selection & Use of Residual Current Devices

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

TechnologyCompendium 3.4. PV Grid Integration. Backgrounds, requirements, and SMA solutions

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

sma FlexIble storage system

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Communication interface for SMA inverters SMA WEBCONNECT DATA MODULE

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

6 ELECTRICAL PARAMETERS

PID - The Problem and How to Solve It

Standards, formulae, tables

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Sunny Boy Accessories SMA POWER BALANCER

Permissible ambient temperature Operation Storage, transport

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

A B Brown. This sheet forms part of *Inspection Report Number/*Certificate Number NA/ * EC/ * PIR *Delete as applicable DB

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

R.C.C.B. s two-pole LEXIC

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Application of Four-Pole Circuit Breakers within Data Centers

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Electrical Safety Tester Verification

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

ABB Inc. April 19, 2011 Slide 1

PHOENIX CONTACT - 01/2007

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Safety technique. Emergency stop module BO 5988 safemaster

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

Section B: Electricity

Product and functional description

Sunny Boy SB 700. String Inverter 700 W, grid-tied operation, grid frequency 777,00 50 Hz / 60 Hz auto-detection SB 1100LV

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

EDS LV NETWORK EARTHING DESIGN

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Appliance Multitester C.A 6155

SURGE PROTECTIVE DEVICES

A Guide to 17th Edition Testing

DALI RC BASIC SO. Control unit Operating instructions

Consumer Products Services Germany GmbH Türkheim Germany

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Infrarot-Bewegungsmelder IP44

Application Note: String sizing Conext CL Series

Operating Manual SUNNY BOY 1.5 / 2.5

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

PV Inverter SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

Operating Manual SUNNY BOY 3000TL / 3600TL / 4000TL / 5000TL

User Guide. Model Insulation Tester / Megohmmeter

SELECTION OF FINAL CIRCUIT PROTECTION

EurotestXE MI 3102H BT MI 3102 BT Instruction manual Version 1.1, Code no

User s Manual Before using the inverter, you need to read and save the safety instructions.

Actuator-Sensor-Interface

Satcon Solstice 100 kw System Solution

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Transcription:

Criteria for Selecting a Residual-Current Device Use of Residual-Current Devices for SUNNY BOY, SUNNY MINI CENTRAL and SUNNY TRIPOWER Content When installing inverters, there are often uncertainties when using a residual-current device. For PV plants, above all DIN VDE 0100-410 (IEC 60364-4-41:2005) and DIN VDE 0100-712 (IEC60364-7-712:2002) may be applied. Residual-current devices are used as protection against indirect contact (personal safety). RCD-TI-en-43 Version 4.3 1/11

Definition 1 Definition 1.1 Protective Measure According to DIN VDE 0100-410 (IEC 60364-4-41:2005) According to this standard, a measure protecting against electric shock consists of two safety precautions: Basic protection: protection from direct contact. Fault protection: protection in the event of a fault. This safety precaution takes effect when the basic protection ceases to be effective and prevents physical damage. The installation of a PV plant on the AC side is generally protected through automatic disconnection of supply. Apart from the insulation of live parts as basic protection, fault protection is also established through protective electric bonding and through a disconnection device. It must disconnect within the specified time after occurrence of the fault (at 230 V AC : 0.2 s in TT grounding systems or 0.4 s in TN grounding systems). 1.2 Grounding Systems TT Grounding System SMA Solar Technology AG 2/11

Definition TN Grounding Systems TN-C Grounding System TN-S Grounding System TN-C-S Grounding System SMA Solar Technology AG 3/11

Definition 1.3 Abbreviations, Symbols and Formula Symbols LS Miniature circuit-breaker Circuit symbol for miniature circuit-breaker RCD Residual-current device RCMU (All-pole sensitive) residual-current monitoring unit I a Current causing automatic disconnection within the required time (short-circuit protection) If the miniature circuit-breaker has B-characteristics, this will be 5 times the nominal current (I nom ) of the miniature circuit-breaker. In case of C-characteristics, it will be 10 times as high, e.g. LS C16 A => I a = 160 A. I nom Nominal current of the miniature circuit-breaker I Δf Rated residual current of the residual-current device R A Total resistance of the ground electrode and protective conductor of the exposed conductive part to be protected U 0 Nominal AC voltage of the line conductor to ground Z S Loop impedance of the error loop (consisting of power source, line conductor to the fault location and protective conductor between fault location and power source) R A and Z S in TT grounding system Z S in TN grounding system SMA Solar Technology AG 4/11

Disconnection Options 2 Disconnection Options Automatic disconnection can be established through protective electric bonding combined with a miniature circuit-breaker or a residual-current device in accordance with DIN VDE 0100-410 (IEC 60364-4-41:2005). 2.1 Automatic Disconnection via Miniature Circuit-Breaker A miniature circuit-breaker can guarantee the automatic disconnection if the following conditions are met: TN grounding system: If TT grounding system:, then the miniature circuit-breaker can guarantee protection through automatic disconnection. A residual-current device is required as primary fault protection. If, then the miniature circuit-breaker can also guarantee protection through automatic disconnection. Example: Disconnection through miniature circuit-breaker in case of a fault in the TN-C-S grounding system SMA Solar Technology AG 5/11

Disconnection Options 2.2 Automatic Disconnection via Residual-Current Device A residual-current device guarantees automatic disconnection if the following conditions are fulfilled: TN grounding system: In the TN grounding system, the residual currents are much higher than the rated residual current IΔf of the residual-current device. This means that the disconnection times must always be maintained with the residual-current device. Residual-current devices must not be used in in TN-C grounding systems. TT grounding systems: A residual-current device is required as primary fault protection. If, the residual-current device can guarantee protection through automatic disconnection. Example: Disconnection by residual-current device in case of a fault in the TT grounding system 2.3 Selecting Disconnection Options It must be examined whether the miniature circuit-breaker provided for line protection is sufficient for automatic disconnection (see Section 2.1 "Automatic Disconnection via Miniature Circuit-Breaker" (page 5)). If this is the case, a current flows via the error loop (depending on the extent of the loop impedance) which is greater than the operating current I a (short-circuit protection). The miniature circuit-breaker can therefore disconnect within the required times. If loop impedance is too high, a residual-current device must also be installed (except in the TN-C grounding system). SMA Solar Technology AG 6/11

Other Reasons for Using a Residual-Current Device 3 Other Reasons for Using a Residual-Current Device 3.1 Outdoor Installations There is widespread opinion that a residual-current device must always be used for outdoor installations. In accordance with DIN VDE 0100-410 (IEC 60364-4-41:2005), this only applies to final circuits for outdoor portable electric equipment with a rated current of up to 32 A. 3.2 Requirements of the Grid Operator Some grid operators adjust the general technical connection requirements (TCR) for their grid and therefore deviate from the standards. These specific technical connection requirements may therefore also require the use of a residual-current device. If the grid operator requires a residual-current device, the type and use conditions are governed by the technical connection requirements (TCR). However, grid operators often do not explicitly require the use of a residual-current device, but just a "standard-compliant installation". 3.3 Necessity due to Other Standards Depending on the installation site and local conditions, a residual-current device may be necessary due to other standards or regulations. If the installation is located in a barn or in wooden cabins, for example, DIN VDE 0100-482 (IEC 60364-4-42:2001-08) also applies. In that case, a residual-current device with a rated residual current of max. 300 ma is required for fire protection reasons. The various influences can only be assessed by the installer on site. Standard installations and special features of PV plants are explained in Section 4 "Selecting the Residual-Current Device for a PV Plant" (page 8). 3.4 Additional Protection SMA Solar Technology AG recommends always installing a residual-current device as additional protection in order to achieve the highest possible degree of safety. It can also provide the function of an all-pole disconnecting switch, which is frequently required for other reasons. SMA Solar Technology AG 7/11

Selecting the Residual-Current Device for a PV Plant 4 Selecting the Residual-Current Device for a PV Plant Besides the criteria mentioned before, there are further reasons for the selection of a residual-current device in PV plants. 4.1 Requirement as per DIN VDE 0100-712 (IEC60364-7-712:2002) If intended as fault protection (see Section 2.2 "Automatic Disconnection via Residual-Current Device" (page 6)), DIN VDE 0100-712 requires a type B residual-current device for transformerless inverters. This requirement also applies to inverters with HF transformers, since there is no galvanic isolation between the AC current side and the DC voltage side. This requirement does not apply to inverters with LF transformers. One exception to this is if the manufacturer of the inverter can exclude the possibility of DC residual currents in the system. If necessary, type A residual-current devices can be used. All SMA inverters with transformer, including SB 2000HF-30, SB 2500HF-30, SB 3000HF-30, and the transformerless SMA inverters listed below are not capable of feeding-in DC residual currents due to their design. They fulfill this requirement in accordance with DIN VDE 0100-712 (IEC60364-7-712:2002). Sunny Boy: SB 240-10, Multigate-10, SB 1300TL-10, SB 1.5-1VL-40, SB 1600TL-10, SB 2100TL, SB 2.5-1VL-40, SB 2500TLST-21, SB 3000TL-20, SB 3000TL-21, SB 3000TLST 21, SB 3600TL 21, SB 3600SE-10, SB 4000TL 20, SB 4000TL-21, SB 5000TL-20, SB 5000TL-21, SB 5000SE-10, SB 6000TL-21 Sunny Mini Central: SMC 6000TL, SMC 7000TL, SMC 8000TL, SMC 9000TL-10, SMC 9000TLRP-10, SMC 10000TL-10, SMC 10000TLRP-10, SMC 11000TL-10, SMC 11000TLRP-10 Sunny Tripower: STP 5000TL-20, STP 6000TL-20, STP 7000TL-20, STP 8000TL-10, STP 8000TL-20, STP 9000TL-20, STP 10000TL-10, STP10000TL-20, STP 12000TL-10, STP 12000TL-20, STP 15000TL-10, STP 15000TLHE-10, STP 15000TLEE-10, STP 17000TL-10, STP 20000TLHE-10, STP 20000TL-30, STP 20000TLEE-10, STP 25000TL-30 The possibilities of faults were examined without taking the integrated residual-current monitoring unit (RCMU) into account. When examining these faults in terms of the currently valid installation standards, no danger in combination with a type A upstream residual-current device can occur. Accordingly, faults that would otherwise require the use of a type B residual-current device due to the inverter can be excluded. SMA Solar Technology AG 8/11

Selecting the Residual-Current Device for a PV Plant The integrated all-pole sensitive residual-current monitoring unit (RCMU) results in additional safety. For inverters with grounding conductor monitoring, this must be activated. These statements also apply to versions of the listed devices with deviating power. 4.2 Operational Differential Currents When operating a transformerless inverter, differential currents occur due to the insulation resistance and capacities of the PV array. In order to prevent unintentional triggering during operation, the rated residual current of the residual-current device must be at least 100 ma. For every connected inverter, a rated residual current of 100 ma must be provided. The rated residual current of the residual-current device must be equal to at least the sum of the rated residual currents of the connected inverters. That means that, if, for example, 3 transformerless inverters are connected, the rated residual current of the residual-current device must be at least 300 ma. For the inverter types SB 1300TL-10, SB 1600TL-10, SB 2100TL, SMC 6000TL, SMC 7000TL and SMC 8000TL, only the following residual-current devices must be used: Residual-current device type A by ABB, type F202A-xx/0,x or F204A-xx/0,x Residual-current device type A by Siemens, type 5SM1. or 5SM3. Other residual-current devices by other manufacturers are currently being tested. In this case it must be taken into account that the operating currents resulting from the differential DC currents during operation can be slightly higher than the rated residual current of the residual-current device used (0-30%). By contrast to the conditions explained in Section 2.2 "Automatic Disconnection via Residual-Current Device" (page 6) for the use of a residual-current device, in this case, the following applies: If, then the residual-current device can guarantee protection through automatic disconnection. If the use of the residual-current devices suggested above is not possible, we recommend using other inverters. When taking into account the criteria mentioned above, PV plants can be installed both in compliance with the appropriate standard and in a cost-optimized way. The suitability of the above-mentioned transformerless SMA inverters for type A residual-current devices in particular facilitate a low-cost installation. SMA Solar Technology AG 9/11

Calculation Examples 5 Calculation Examples The selection of suitable electric equipment as fault protection through automatic disconnection is illustrated in 2 examples below. It is always assumed that the necessary protective electric bonding is being carried out simultaneously. The values used are examples which cannot be used as guideline values for the respective grounding system or application. 5.1 Calculation Example 1 1 Sunny Boy SB 2100TL; fused with a miniature circuit-breaker B16A; TN grounding system; loop impedance Zs = 1.5 Ω; barn roof: LS B16A has a short-circuit operating current I a of 80 A (B-characteristics: factor 5; I nom of the miniature circuit-breaker = 16 A => 5 x 16 A = 80 A). At 230 V, 153 A can flow through the fault loop ( ). The 153 A are higher than the required 80 A operating current of the miniature circuit-breaker. Therefore, the miniature circuit-breaker will disconnect safely within the specified time. LS B16A suffices as fault protection against indirect contact. However, since it is a barn, in this case an additional type A residual-current device with a rated residual current of max. 300 ma must be installed. That is required in accordance with DIN VDE 0100-482 (IEC 60364-4-42:2001-08) for fire protection reasons. SMA Solar Technology AG 10/11

Calculation Examples 5.2 Calculation Example 2 3 Sunny Mini Centrals SMC 6000TL; fused with one miniature circuit-breaker C32A each; TT grounding system; loop impedance Zs = 0.2 Ω; R A = 1.1 Ω: LS C32A has a short-circuit operating current of 320 A (C-characteristics: factor 10; Inom of the miniature circuit-breaker = 32 A => 10 x 32 A = 320 A). 230 V At 230 V, 177 A can flow through the fault loop ( ). 1,3 Ω = 177 A The 177 A are lower than the required 320 A operating current of the miniature circuit-breaker. Therefore, the miniature circuit-breaker will not disconnect safely within the specified time. LS C32A is not sufficient as fault protection against indirect contact. First option: use of another miniature circuit-breaker (if possible) If using a miniature circuit-breaker B32A, the short-circuit operating current would be 160 A (B-characteristics: factor 5; I nom of the miniature circuit-breaker = 32 A => 5 x 32 A = 160 A). The operating current of the miniature circuit-breaker with B-characteristics would be less than the 177 A which would flow in the event of a fault. Therefore, these miniature circuit-breakers would disconnect within the specified time. The miniature circuit-breaker B32A suffices as fault protection against indirect contact. Second option: use of a residual-current device In case no other miniature circuit-breaker can be employed, a residual-current device must be used for fault protection. Since 3 transformerless inverters are being used, the rated residual current according to Section 4.2 "Operational Differential Currents" (page 9) must be at least 300 ma. A residual-current device with a rated residual current I Δf of 500 ma is selected. In addition, it should be tested according to the condition of 4 b (see page 9), whether the protective effects are sufficient: 50 V R A = 1,1 Ω <, thus 1,3 x I Δf A type A residual-current device with a rated residual current IΔf of 500 ma guarantees fault protection against indirect contact. SMA Solar Technology AG 11/11