Operating Manual SUNNY BOY 3000TL / 3600TL / 4000TL / 5000TL
|
|
|
- Rodger Burke
- 9 years ago
- Views:
Transcription
1 Operating Manual SUNNY BOY 3000TL / 3600TL / 4000TL / 5000TL SB30-50TL-21-BE-en-11 Version 1.1 AMERICAN ENGLISH
2 Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in these documents is property of SMA Solar Technology AG. Any publication, whether in whole or in part, requires prior written approval by SMA Solar Technology AG. Internal reproduction used solely for the purpose of product evaluation or other proper use is allowed and does not require prior approval. SMA Warranty You can download the current warranty conditions from the Internet at Trademarks All trademarks are recognized, even if not explicitly identified as such. A lack of identification does not mean that a product or symbol is not trademarked. The BLUETOOTH word mark and logos are registered trademarks of Bluetooth SIG, Inc. and any use of these marks by SMA Solar Technology AG is under license. Modbus is a registered trademark of Schneider Electric and is licensed by the Modbus Organization, Inc. QR Code is a registered trademark of DENSO WAVE INCORPORATED. Phillips and Pozidriv are registered trademarks of Phillips Screw Company. Torx is a registered trademark of Acument Global Technologies, Inc. SMA Solar Technology AG Sonnenallee Niestetal Germany Tel Fax [email protected] 2004 to 2014 SMA Solar Technology AG. All rights reserved. 2 SB30-50TL-21-BE-en-11 Operating Manual
3 SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Document Validity Target Group Additional Information Symbols Nomenclature Safety Intended Use Safety Information Scope of Delivery Product Description Sunny Boy Interfaces and Functions Mounting Requirements for Mounting Mounting the Inverter Electrical Connection Safety during Electrical Connection Overview of the Connection Area View from Below Interior View AC Connection Requirements for the AC Connection Connecting the Inverter to the Utility Grid Connecting Additional Grounding DC Connection Requirements for the DC Connection Connecting the PV Array Commissioning Commissioning Procedure Operating Manual SB30-50TL-21-BE-en-11 3
4 Table of Contents SMA Solar Technology AG 7.2 Configuring the Country Data Set Setting the NetID Commissioning the Inverter Self-Test in Accordance with CEI 0-21 for PV Systems 6 kw Starting the Self-Test Restarting the Self-Test Configuration Configuration Procedure Changing the Display Language Integrating the Inverter into the Network Changing Operating Parameters Deactivating Grounding Conductor Monitoring Setting SMA OptiTrac Global Peak Operation LED Signals Display Overview Activating and Operating the Display Calling Up Display Messages of the Start-Up Phase Disconnecting the Inverter from Voltage Sources Technical Data DC/AC Sunny Boy 3000TL / 3600TL Sunny Boy 4000TL / 5000TL General Data Protective Devices Climatic Conditions Equipment Torques Electronic Solar Switch Data Storage Capacity Accessories SB30-50TL-21-BE-en-11 Operating Manual
5 SMA Solar Technology AG Table of Contents 13 Contact EC Declaration of Conformity Operating Manual SB30-50TL-21-BE-en-11 5
6 1 Information on this Document SMA Solar Technology AG 1 Information on this Document 1.1 Validity This document is valid for the following device types from firmware version 2.55: SB 3000TL-21 (Sunny Boy 3000TL) SB 3600TL-21 (Sunny Boy 3600TL) SB 4000TL-21 (Sunny Boy 4000TL) SB 5000TL-21 (Sunny Boy 5000TL) 1.2 Target Group This document is intended for qualified persons and end users. Only qualified persons are allowed to perform the activities marked in this document with a warning symbol and the caption "Qualified person". Tasks that do not require any particular qualification are not marked and can also be performed by end users. Qualified persons must have the following skills: Knowledge of how an inverter works and is operated Training in how to deal with the dangers and risks associated with installing and using electrical devices and installations Training in the installation and commissioning of electrical devices and installations Knowledge of the applicable standards and directives Knowledge of and compliance with this document and all safety information 1.3 Additional Information Links to additional information can be found at Document title and content Troubleshooting, Cleaning, Replacement of Varistors and Decommissioning "Overview of the Rotary Switch Settings" Overview of the rotary switch settings for configuring the country data set and display language "Efficiency and Derating" Efficiency and Derating Behavior of the Sunny Boy, Sunny Tripower and Sunny Mini Central Inverters Document type Service Manual Technical Information Technical Information "Criteria for Selecting a Residual-Current Device" Technical Information "Circuit Breaker" Dimensioning and Selection of a Suitable AC Circuit Breaker for Inverters under PV-Specific Influences Technical Information 6 SB30-50TL-21-BE-en-11 Operating Manual
7 SMA Solar Technology AG 1 Information on this Document Document title and content "Insulation Resistance (Riso) of Non-Galvanically Isolated PV Systems" "Integrated Plant Control and Q on Demand 24/7" Detailed explanation of functions and description for setting the functions "Webconnect Systems in Sunny Portal" Registration in Sunny Portal "Firmware Update with SD Card" "Parameter list" Overview of All Inverter Operating Parameters and Their Configuration Options Document type Technical Information Technical Information User Manual Technical Description Technical Information 1.4 Symbols Symbol 1.5 Nomenclature Complete designation Sunny Boy Explanation Indicates a hazardous situation which, if not avoided, will result in death or serious injury Indicates a hazardous situation which, if not avoided, can result in death or serious injury Indicates a hazardous situation which, if not avoided, can result in minor or moderate injury Indicates a situation which, if not avoided, can result in property damage Sections describing activities to be performed by qualified persons only Information that is important for a specific topic or goal, but is not safety-relevant Indicates a requirement for meeting a specific goal Desired result A problem that might occur Designation in this document Inverter, product Operating Manual SB30-50TL-21-BE-en-11 7
8 1 Information on this Document SMA Solar Technology AG Complete designation Electronic Solar Switch SMA BLUETOOTH Wireless Technology Designation in this document ESS BLUETOOTH 8 SB30-50TL-21-BE-en-11 Operating Manual
9 SMA Solar Technology AG 2 Safety 2 Safety 2.1 Intended Use The Sunny Boy is a transformerless PV inverter with two MPP trackers which converts the direct current of the PV array to grid-compliant alternating current and feeds it into the utility grid. The product is suitable for indoor and outdoor use. The product must only be operated with PV arrays of protection class II in accordance with IEC 61730, application class A. The PV modules must be compatible with this product. PV modules with a high capacity to ground must only be used if their coupling capacity does not exceed 1.4 μf (for information on how to calculate the coupling capacity, see the Technical Information "Leading Leakage Currents" at All components must remain within their permitted operating ranges at all times. The product must only be used in countries for which it is approved or released by SMA Solar Technology AG and the grid operator. Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable standards and directives. Any other application may cause personal injury or property damage. Alterations to the product, e.g. changes or modifications, are only permitted with the express written permission of SMA Solar Technology AG. Unauthorized alterations will void guarantee and warranty claims and usually void the operation permit. SMA Solar Technology AG shall not be held liable for any damage caused by such changes. Any use of the product other than that described in the Intended Use section does not qualify as appropriate. The enclosed documentation is an integral part of this product. Keep the documentation in a convenient place for future reference and observe all instructions contained therein. The type label must remain permanently attached to the product. 2.2 Safety Information This section contains safety information that must be observed at all times when working on or with the product. To prevent personal injury and property damage and to ensure long-term operation of the product, read this section carefully and observe all safety information at all times. Operating Manual SB30-50TL-21-BE-en-11 9
10 2 Safety SMA Solar Technology AG Danger to life due to high voltages of the PV array When exposed to sunlight, the PV array generates dangerous DC voltage which is present in the DC conductors and the live components of the inverter. Touching the DC conductors or the live components can lead to lethal electric shocks. If you disconnect the DC connectors from the inverter under load, an electric arc may occur leading to electric shock and burns. Do not touch non-insulated cable ends. Do not touch the DC conductors. Do not touch any live components of the inverter. Have the inverter mounted, installed and commissioned only by qualified persons with the appropriate skills. If an error occurs, have it rectified by qualified persons only. Prior to performing any work on the inverter, disconnect it from all voltage sources as described in this document (see Section 10 "Disconnecting the Inverter from Voltage Sources", page 45). Danger to life due to electric shock Touching an ungrounded PV module or array frame can cause a lethal electric shock. Connect and ground the PV modules, array frame and electrically conductive surfaces so that there is continuous conduction. Observe the applicable local regulations. Risk of burns due to hot enclosure parts Some parts of the enclosure can get hot during operation. Do not touch any parts other than the lower enclosure lid of the inverter during operation. Damage to the display or the type label due to the use of cleaning agents If the inverter is dirty, clean the enclosure, the enclosure lid, the type label, the display and the LEDs with a damp cloth only. 10 SB30-50TL-21-BE-en-11 Operating Manual
11 SMA Solar Technology AG 3 Scope of Delivery 3 Scope of Delivery Check the scope of delivery for completeness and any externally visible damage. Contact your distributor if the scope of delivery is incomplete or damaged. Figure 1: Components included in the scope of delivery Position Quantity Designation A 1 Inverter* B 1 Wall mounting bracket C 4 Positive DC connector D 4 Negative DC connector E 8 Sealing plug for DC connectors F 1 Cable gland M32x1.5 G 1 Counter nut for cable gland M32x1.5 H 1 Quick Reference Guide for Installation, installation manual of the SMA Speedwire/Webconnect data module, installation manual of the DC connectors, supplementary sheet with default settings, supplementary sheet with access data for registration in Sunny Portal I 1 Warning label * Optional without Electronic Solar Switch (ESS) Operating Manual SB30-50TL-21-BE-en-11 11
12 4 Product Description SMA Solar Technology AG 4 Product Description 4.1 Sunny Boy The Sunny Boy is a transformerless PV inverter with two MPP trackers which converts the direct current of the PV array to grid-compliant alternating current and feeds it into the utility grid. Figure 2: Design of the Sunny Boy Position A B C D Explanation Upper enclosure lid Type label The type label uniquely identifies the inverter. You will require the information on the type label to use the product safely and when seeking customer support from the SMA Service Line. You will find the following information on the type label: Device type (Model) Serial number (Serial No.) Date of manufacture Device-specific characteristics Additional label with details for registration in Sunny Portal: Internet address of the PV System Setup Assistant Identification key (PIC) Registration ID (RID) LEDs The LEDs indicate the operating state of the inverter (see Section 9.1 "LED Signals", page 41). 12 SB30-50TL-21-BE-en-11 Operating Manual
13 SMA Solar Technology AG 4 Product Description Position E F G * Optional Explanation Display The display shows the current operating data and events or errors (see Section 9.2 "Display Overview", page 41). Electronic Solar Switch (ESS)* The ESS and the DC connectors together form a DC load-break switch. When plugged in, the ESS forms a conductive path between the PV array and the inverter. Removing the ESS interrupts the DC electric circuit and removing all DC connectors disconnects the PV array completely from the inverter. Lower enclosure lid Symbols on the inverter, the type label and the ESS Symbol Explanation Inverter Together with the green LED, this symbol indicates the operating state of the inverter. Observe the documentation Together with the red LED, this symbol indicates an error (for troubleshooting, see the service manual at BLUETOOTH Together with the blue LED, the symbol indicates active communication via BLUETOOTH. Danger This symbol indicates that the inverter must be additionally grounded if additional grounding or equipotential bonding is required at the installation site (see Section 6.3.3, page 27). QR Code Links to additional information on the inverter can be found at Operating the inverter without the lower enclosure lid is prohibited. Always operate the inverter with the lower enclosure lid. Operating Manual SB30-50TL-21-BE-en-11 13
14 4 Product Description SMA Solar Technology AG Symbol Explanation Operating principle of the ESS: If the ESS is plugged in, the DC electric circuit is closed. To interrupt the DC electric circuit, you must perform the following steps in the given order: Remove the ESS. Unlock and remove all DC connectors. Danger to life due to electric shock The product operates at high voltages. All work on the product must be carried out by qualified persons only. Risk of burns due to hot surfaces The product can get hot during operation. Avoid contact during operation. Allow the product to cool down sufficiently before carrying out any work. Observe the documentation Observe all documentation supplied with the product. Direct current The product does not have a transformer. Alternating current WEEE designation Do not dispose of the product together with the household waste but in accordance with the locally applicable disposal regulations for electronic waste. CE marking The product complies with the requirements of the applicable EU directives. Device class ID The product is equipped with a wireless component and complies with device class 2. Degree of protection IP65 The product is protected against dust intrusion and water jets from any angle. 14 SB30-50TL-21-BE-en-11 Operating Manual
15 SMA Solar Technology AG 4 Product Description Symbol Explanation The product is suitable for outdoor installation. Certified safety The product is VDE-tested and complies with the requirements of the German Equipment and Product Safety Act. RCM (Regulatory Compliance Mark) The product complies with the requirements of the applicable Australian standards. 4.2 Interfaces and Functions The inverter can be equipped or retrofitted with the following interfaces and functions: BLUETOOTH Via BLUETOOTH, the inverter can communicate with various BLUETOOTH devices (for information on supported SMA products, see SMA Speedwire/Webconnect The inverter is equipped with SMA Speedwire/Webconnect as standard. SMA Speedwire/ Webconnect is a type of communication based on the Ethernet standard. This enables inverteroptimized 10/100 Mbit data transmission between Speedwire devices in PV systems and the software Sunny Explorer. The Webconnect function enables direct data transmission between the inverters of a small-scale system and the Internet portal Sunny Portal without any additional communication device and for a maximum of four inverters per Sunny Portal system. In large-scale PV power plants, data transmission to the Internet portal Sunny Portal is carried out via the SMA Cluster Controller. You can access your Sunny Portal system from any computer with an Internet connection. SMA Speedwire/Webconnect enables, for PV systems operated in Italy, the connection to or disconnection of the inverter from the utility grid and definition of the frequency limits to be used with IEC61850-GOOSE messages. RS485 interface The inverter can communicate via cables with special SMA communication products via the RS485 interface (information on supported SMA products at The RS485 interface can be retrofitted. Grid Management Services The inverter is equipped with service functions for grid management. Depending on the requirements of the grid operator, you can activate and configure the functions (e.g. active power limitation) via operating parameters. Operating Manual SB30-50TL-21-BE-en-11 15
16 4 Product Description SMA Solar Technology AG SMA Power Control Module The SMA Power Control Module enables the inverter to implement grid management services and is equipped with an additional multifunction relay (for information on installation and configuration, see the installation manual of the SMA Power Control Module). The SMA Power Control Module can be retrofitted. Multifunction Relay You can configure the multifunction relay for various operating modes. The multifunction relay is used, for example, to switch fault indicators on or off (for information on installation and configuration, see the installation manual of the multifunction relay). The multifunction relay can be retrofitted. Fan retrofit kit The fan retrofit kit is used for additional inverter cooling at high ambient temperatures and also has a multifunction relay (for information on installation and configuration, see the installation manual of the fan retrofit kit). The fan retrofit kit can be retrofitted and must not be operated in parallel with the SMA Power Control Module. SMA OptiTrac Global Peak SMA OptiTrac Global Peak is an advancement of SMA OptiTrac and allows the operating point of the inverter to follow the optimal operating point of the PV array (MPP) precisely at all times. In addition, with the aid of SMA OptiTrac Global Peak, the inverter can detect the presence of several maximum power points in the available operating range, such as may occur particularly with partially shaded strings. SMA OptiTrac Global Peak is enabled by default. All-pole sensitive residual-current monitoring unit The all-pole sensitive residual-current monitoring unit detects alternating and direct differential currents. In single-phase and three-phase inverters, the integrated differential current sensor detects the current difference between the neutral conductor and the line conductor(s). If the current difference increases suddenly, the inverter disconnects from the utility grid. 16 SB30-50TL-21-BE-en-11 Operating Manual
17 SMA Solar Technology AG 5 Mounting 5 Mounting 5.1 Requirements for Mounting Requirements for the mounting location: Danger to life due to fire or explosion Despite careful construction, electrical devices can cause fires. Do not mount the inverter in areas containing highly flammable materials or gases. Do not mount the inverter in a potentially explosive atmosphere. The mounting location must be inaccessible to children. A solid support surface must be available for mounting, e.g. concrete or masonry. When mounted on drywall or similar materials in the living area, the inverter emits audible vibrations during operation which could be perceived as annoying. The mounting location must be suitable for the weight and dimensions of the inverter (see Section 11 "Technical Data", page 47). To ensure optimum operation, the ambient temperature should be between -25 C and 40 C. The mounting location should not be exposed to direct solar irradiation. Direct solar irradiation can cause the inverter to overheat. As a result, the inverter reduces its power output. Climatic conditions must be met (see Section 11 "Technical Data", page 47). The mounting location should be freely and safely accessible at all times without the need for any auxiliary equipment (such as scaffolding or lifting platforms). Non-fulfillment of these criteria may restrict servicing. Operating Manual SB30-50TL-21-BE-en-11 17
18 5 Mounting SMA Solar Technology AG Dimensions for mounting: Figure 3: Position of the anchoring points Recommended clearances: If you maintain the recommended clearances, adequate heat dissipation will be ensured. Thus, you will prevent power reduction due to excessive temperature. Maintain the recommended clearances to walls as well as to other inverters or objects. If multiple inverters are mounted in areas with high ambient temperatures, increase the clearances between the inverters and ensure sufficient fresh-air supply. 18 SB30-50TL-21-BE-en-11 Operating Manual
19 SMA Solar Technology AG 5 Mounting Figure 4: Recommended clearances Permitted and prohibited mounting positions: The inverter must be mounted in one of the permitted positions. This will ensure that no moisture can penetrate the inverter. The inverter should be mounted in such way that display messages and LED signals can be read without difficulty. Figure 5: Permitted and prohibited mounting positions 5.2 Mounting the Inverter Additionally required mounting material (not included in the scope of delivery): Three screws suitable for the support surface (diameter: at least 6 mm) Three washers suitable for the screws (outer diameter: at least 18 mm) If necessary, three screw anchors suitable for the support surface and the screws To secure the inverter against theft: one padlock suitable for outdoor use Operating Manual SB30-50TL-21-BE-en-11 19
20 5 Mounting SMA Solar Technology AG Risk of injury when lifting the inverter, or if it is dropped The inverter weighs 30 kg. There is risk of injury if the inverter is lifted incorrectly or dropped while being transported or when attaching it to or removing it from the wall mounting bracket. Transport and lift the inverter carefully. Procedure: 1. Risk of injury due to damaged cables There may be power cables or other supply lines (e.g. gas or water) routed in the wall. Ensure that no lines are laid in the wall which could be damaged when drilling holes. 2. Align the wall mounting bracket horizontally on the wall and mark the position of the drill holes. Use at least two holes on the right-hand and left-hand side and the lower hole in the middle of the wall mounting bracket. Useful hint: When mounting on a post, use the upper and lower central holes of the wall mounting bracket. 3. Set the wall mounting bracket aside and drill the marked holes. 4. Insert screw anchors into the drill holes if the support surface requires them. 5. Secure the wall mounting bracket using screws and washers. 6. Hook the inverter into the wall mounting bracket. 7. Ensure that the inverter is securely in place. 8. To protect the inverter against theft or from falling down in the event of an earthquake, use an appropriate padlock. Place the shackle of the padlock through the metal bracket on the wall mounting bracket and through the bracket on the rear of the inverter. Guide the shackle outwards from the center of the inverter. Close the padlock. Keep the key of the padlock in a safe place. 20 SB30-50TL-21-BE-en-11 Operating Manual
21 SMA Solar Technology AG 6 Electrical Connection 6 Electrical Connection 6.1 Safety during Electrical Connection Danger to life due to high voltages of the PV array When exposed to sunlight, the PV array generates dangerous DC voltage which is present in the DC conductors and the live components of the inverter. Touching the DC conductors or the live components can lead to lethal electric shocks. If you disconnect the DC connectors from the inverter under load, an electric arc may occur leading to electric shock and burns. Do not touch non-insulated cable ends. Do not touch the DC conductors. Do not touch any live components of the inverter. Have the inverter mounted, installed and commissioned only by qualified persons with the appropriate skills. If an error occurs, have it rectified by qualified persons only. Prior to performing any work on the inverter, disconnect it from all voltage sources as described in this document (see Section 10 "Disconnecting the Inverter from Voltage Sources", page 45). Damage to the inverter due to electrostatic discharge Touching electronic components can cause damage to or destroy the inverter through electrostatic discharge. Ground yourself before touching any component. Operating Manual SB30-50TL-21-BE-en-11 21
22 6 Electrical Connection SMA Solar Technology AG 6.2 Overview of the Connection Area View from Below Figure 6: Enclosure openings at the bottom of the inverter Position A B C D E * Optional Designation Pin connector for the ESS* Cable gland M20x1.5 for the connection to the multifunction relay or SMA Power Control Module* Enclosure opening with filler plug for cable gland M32x1.5 with two-hole cable support sleeve Enclosure opening with filler plug Cable gland M32x1.5 for the AC cable 22 SB30-50TL-21-BE-en-11 Operating Manual
23 SMA Solar Technology AG 6 Electrical Connection Interior View Figure 7: Connection areas in the interior of the inverter Position A B C D E F G H I K L M * Optional Designation 2 positive and 2 negative DC connectors, input A Pin connector for the ESS* 2 positive and 2 negative DC connectors, input B Pin connector for connecting the multifunction relay, the SMA Power Control Module or the fan retrofit kit* Pin connector for connecting the Speedwire/Webconnect interface or the RS485 interface* Connecting terminal plate for connecting the AC cable Switch for temporarily changing the display language to English (for service purposes) Rotary switch C for configuring the NetID Rotary switch A and B for setting the country data set and the display language Slot for SD memory card Mounting location for the fan retrofit kit* Grounding terminal for additional grounding of the inverter Operating Manual SB30-50TL-21-BE-en-11 23
24 6 Electrical Connection SMA Solar Technology AG 6.3 AC Connection Requirements for the AC Connection Cable requirements: External diameter: 12 mm to 21 mm Conductor cross-section: 1.5 mm² to 10 mm² Insulation stripping length: 12 mm The cable must be dimensioned in accordance with the local and national directives for the dimensioning of cables. The requirements for the minimum wire size derive from these directives. Examples of factors influencing cable dimensioning are: nominal AC current, type of cable, routing method, cable bundling, ambient temperature and maximum desired line losses (for calculation of line losses, see the design software "Sunny Design" from software version 2.0 at Load-break switch and cable protection: Damage to the inverter due to the use of screw-type fuses as load-break switches Screw-type fuses (e.g. DIAZED fuse or NEOZED fuse) are not load-break switches. Do not use screw-type fuses as load-break switches. Use a load-break switch or circuit breaker as a load disconnection unit (for information and design examples, see the Technical Information "Circuit Breaker" at In PV systems with multiple inverters, protect each inverter with a separate circuit breaker. Make sure to observe the maximum permissible fuse protection (see Section 11 "Technical Data", page 47). This will prevent residual voltage being present at the corresponding cable after disconnection. Loads installed between the inverter and the circuit breaker must be fused separately. Residual-current monitoring unit: If an external residual-current device is required, install a residual-current device which trips at a residual current of 100 ma or higher (for details on selecting a residual-current device, see the Technical Information "Criteria for Selecting a Residual-Current Device" at Solar.com). Overvoltage category: The inverter can be used in grids of overvoltage category III or lower in accordance with IEC That means that the inverter can be permanently connected to the grid-connection point of a building. In case of installations with long outdoor cabling routes, additional measures to reduce overvoltage category IV to overvoltage category III are required (see the Technical Information "Overvoltage Protection" at 24 SB30-50TL-21-BE-en-11 Operating Manual
25 SMA Solar Technology AG 6 Electrical Connection Grounding conductor monitoring: The inverter is equipped with a grounding conductor monitoring device. This grounding conductor monitoring device detects when there is no grounding conductor connected and disconnects the inverter from the utility grid if this is the case. Depending on the installation site and grid configuration, it may be advisable to deactivate the grounding conductor monitoring. This is necessary, for example, in an IT system if there is no neutral conductor present and you intend to install the inverter between two line conductors. If you are uncertain about this, contact your grid operator or SMA Solar Technology AG. Grounding conductor monitoring must be deactivated after initial start-up depending on the grid configuration (see Section 8.5, page 40). Safety in accordance with IEC when the grounding conductor monitoring is deactivated In order to guarantee safety in accordance with IEC when the grounding conductor monitoring is deactivated, carry out one of the following measures: Connect a grounding conductor made of copper wire with a cross-section of at least 10 mm² to the connecting terminal plate for the AC cable. Connect additional grounding with the same cross-section as the connected grounding conductor to the connecting terminal plate for the AC cable (see Section 6.3.3, page 27 ). This prevents touch current if the grounding conductor at the connecting terminal plate for the AC cable fails. Connection of additional grounding In some countries, additional grounding is generally required. In each case, observe the locally applicable regulations. If additional grounding is required, connect an additional grounding with the same crosssection as the connected grounding conductor to the connecting terminal plate for the AC cable (see Section 6.3.3, page 27). This prevents touch current if the grounding conductor at the connecting terminal plate for the AC cable fails Connecting the Inverter to the Utility Grid Requirements: The connection requirements of the grid operator must be met. The grid voltage must be in the permissible range. The exact operating range of the inverter is specified in the operating parameters. Procedure: 1. Disconnect the circuit breaker and secure it against reconnection. 2. If an additional DC load-break switch is available, switch off the DC load-break switch and secure against reconnection. 3. If the ESS is installed and plugged in, remove the ESS. 4. If the lower enclosure lid is mounted, loosen all screws of the lower enclosure lid using an Allen key (AF 3) and remove the enclosure lid. Operating Manual SB30-50TL-21-BE-en-11 25
26 6 Electrical Connection SMA Solar Technology AG 5. Loosen the screw on the display and flip the display up to have more space to make the connection. The display clicks into place. 6. Unscrew the swivel nut from the cable gland. 7. If the outer diameter of the cable is between 15 mm and 21 mm, remove the inner sealing ring from the cable gland. 8. Move the swivel nut of the cable gland over the AC cable and then route the AC cable through the cable gland into the inverter. 9. Dismantle the AC cable. 10. Shorten L and N by 5 mm each. 11. Strip the insulation of L, N and the grounding conductor by 18 mm. 12. Push the locking levers of the connecting terminal plate for the AC cable right up to the stop. 13. Connect the grounding conductor, N and L to the connecting terminal plate for the AC cable in accordance with the labeling. 14. Danger of crushing fingers when locking levers snap shut The locking levers close by snapping down fast and hard. Press the locking levers of the connecting terminal plate for the AC cable down with your thumb only. Do not grip the entire connecting terminal plate for the AC cable. Do not place your fingers under the locking levers. 15. Make sure that all conductors are securely in place. 16. Screw the swivel nut onto the cable gland. 17. If the display is flipped up, flip it down and tighten the screw. 26 SB30-50TL-21-BE-en-11 Operating Manual
27 SMA Solar Technology AG 6 Electrical Connection Connecting Additional Grounding If additional grounding or equipotential bonding is required locally, you can connect additional grounding to the inverter. This prevents touch current if the grounding conductor at the terminal for the AC cable fails. Cable requirement: Grounding cable cross-section: max. 10 mm² Procedure: 1. Strip the grounding cable insulation. 2. Release the screw using an Allen key (AF 4) until the grounding cable can be led under the clamping bracket. 3. Feed the grounding cable under the clamping bracket. Position the grounding conductor on the left-hand side. 4. Tighten the clamping bracket with the screw and conical spring washer (torque: 6 Nm). The teeth of the conical spring washer must face the clamping bracket. 6.4 DC Connection Requirements for the DC Connection Requirements for the PV modules per input: All PV modules must be of the same type. All PV modules must be aligned and tilted identically. On the coldest day based on statistical records, the open-circuit voltage of the PV array must never exceed the maximum input voltage of the inverter. The same number of series-connected PV modules must be connected to each string. The maximum input current per string must be maintained and must not exceed the throughfault current of the DC connectors (see Section 11 "Technical Data", page 47). The thresholds for the input voltage and the input current of the inverter must be adhered to (see Section 11 "Technical Data", page 47). Operating Manual SB30-50TL-21-BE-en-11 27
28 6 Electrical Connection SMA Solar Technology AG The positive connection cables of the PV modules must be fitted with the positive DC connectors (for information on assembling DC connectors, see the DC connector installation manual). The negative connection cables of the PV modules must be fitted with the negative DC connectors (for information on assembling DC connectors, see the DC connector installation manual). If the inverter is not equipped with an ESS and the regulations in the country of installation require an external DC load-break switch, you must install an external DC load-break switch. Use of Y adapters for parallel connection of strings The Y adapters must not be used to interrupt the DC circuit. Do not use the Y adapters in the immediate vicinity of the inverter. The adapters must not be visible or freely accessible. In order to interrupt the DC circuit, always disconnect the inverter as described in this document (see Section 10, page 45). Reduced electromagnetic compatibility of the inverter in case of incorrect DC connection If the positive terminal and the negative terminal of a string are not connected to the same input, electromagnetic compatibility of the inverter cannot be guaranteed. As a result, the inverter can cause electromagnetic interference in other devices. Always connect the positive terminal and the negative terminal of one string to the same input Connecting the PV Array Destruction of the inverter due to overvoltage If the open-circuit voltage of the PV modules exceeds the maximum input voltage of the inverter, the inverter can be destroyed due to overvoltage. If the open-circuit voltage of the PV modules exceeds the maximum input voltage of the inverter, do not connect any strings to the inverter and check the design of the PV system. Destruction of the measuring device due to overvoltage Only use measuring devices with a DC input voltage range of 1,000 V or higher. 28 SB30-50TL-21-BE-en-11 Operating Manual
29 SMA Solar Technology AG 6 Electrical Connection Damage to the DC connectors due the use of contact cleaner of other cleaning agents Some contact cleaners or other cleaning agents may contain substances that decompose the plastic of the DC connectors. Do not use contact cleaners or other cleaning agents for cleaning the DC connectors. Procedure: 1. Ensure that the circuit breaker is switched off and that it cannot be reconnected. 2. If an additional DC load-break switch is available, switch off the DC load-break switch and secure against reconnection. 3. If the ESS is installed and plugged in, remove the ESS. 4. Ensure that there is no ground fault in the PV array (see service manual at Solar.com). 5. Check whether the DC connectors have the correct polarity. If the DC connector is equipped with a DC cable of the wrong polarity, the DC connector must be assembled again. The DC cable must always have the same polarity as the DC connector. 6. Ensure that the open-circuit voltage of the PV array does not exceed the maximum input voltage. 7. Connect the assembled DC connectors to the inverter. The DC connectors snap into place. 8. Ensure that all DC connectors are securely in place. Operating Manual SB30-50TL-21-BE-en-11 29
30 6 Electrical Connection SMA Solar Technology AG 9. Damage to the inverter due to moisture ingress The inverter is only properly sealed when all unused DC inputs are closed with DC connectors and sealing plugs. Do not insert the sealing plugs directly into the DC inputs on the inverter. For unused DC connectors, push down the clamping bracket and push the swivel nut up to the thread. Insert the sealing plug into the DC connector. Tighten the DC connector (torque: 2 Nm). Insert the DC connectors with sealing plugs into the corresponding DC inputs on the inverter. The DC connectors snap into place. Ensure that all DC connectors with sealing plugs are securely in place. 30 SB30-50TL-21-BE-en-11 Operating Manual
31 SMA Solar Technology AG 7 Commissioning 7 Commissioning 7.1 Commissioning Procedure Before you can commission the inverter, you must check various settings and make changes if necessary. This section describes the procedure and gives an overview of the steps, which must always be performed in the prescribed sequence. Procedure 1. Connect to the communication interface. Installation manual of the communication interface 2. Check the country data set configuration of the inverter. Supplementary sheet with the default settings, type label or display 3. If the country data set is not set correctly for your country or your purpose, adjust to the required country data set and the corresponding display language within the first ten feed-in hours via the rotary switches in the inverter. 4. If the inverter is to communicate with several BLUETOOTH devices, or if BLUETOOTH is not to be used as a type of communication, set the NetID. See Section 7.2, page 31 Section 7.3, page Commission the inverter and start a self-test, if required. Section 7.4, page 34 and Section 7.5, page Configuring the Country Data Set A display language is assigned to every country data set. Set the country data set appropriate for your country or purpose, with the corresponding display language, within the first ten feed-in hours via the rotary switches in the inverter. After the first ten feed-in hours, the country data set can only be changed by means of a communication product. If the display language of the country data set does not match the required language, you can change it after commissioning (see Section 8.2 "Changing the Display Language", page 38). The country data set must be set correctly. If you select a country data set which is not valid for your country and purpose, it can cause a disturbance in the PV system and lead to problems with the grid operator. When selecting the country data set, you must always observe the locally applicable standards and directives as well as the properties of the PV system (e.g. PV system size, grid-connection point). If you are not sure which country data set is valid for your country or purpose, contact your grid operator for information on which country data set is to be configured. Operating Manual SB30-50TL-21-BE-en-11 31
32 7 Commissioning SMA Solar Technology AG Procedure: 1. Determine the rotary switch position for your country and purpose. Call up the Technical Information "Overview of the Rotary Switch Settings" at 2. Danger to life due to high voltages Ensure that the inverter is disconnected from all voltage sources and that the enclosure lid is removed (see Section 10, page 45). 3. Set the rotary switches A and B to the required position using a flat-blade screwdriver (blade width: 2.5 mm). The inverter will adopt the setting after commissioning. This can take up to five minutes. 7.3 Setting the NetID By default, the NetID is set to 1 for all SMA inverters and SMA communication products with BLUETOOTH. If your PV system consists of an inverter and a maximum of one further BLUETOOTH device (e.g. computer with BLUETOOTH interface or SMA communication product), you can leave the NetID set to 1. You must change the NetID in the following cases: If your PV system consists of one inverter and two other BLUETOOTH devices (e.g. computer with BLUETOOTH interface and SMA communication product) or of multiple inverters with BLUETOOTH, you must change the NetID of your PV system. This will enable communication with multiple BLUETOOTH devices. If another PV system with BLUETOOTH is located within 500 m of your PV system, you must change the NetID of your PV system. This will help keep both PV systems separate. If you do not wish to communicate via BLUETOOTH, deactivate the BLUETOOTH communication on your inverter. This will protect your PV system from unauthorized access. 32 SB30-50TL-21-BE-en-11 Operating Manual
33 SMA Solar Technology AG 7 Commissioning All BLUETOOTH devices in a PV system must have the same NetID. You can set a new NetID in the inverter by means of the rotary switch C. Figure 8: Positions of rotary switch C Position Explanation 0 Communication via BLUETOOTH is deactivated. 1 Communication via BLUETOOTH with a further BLUETOOTH device 2 to F NetID for communication via BLUETOOTH with multiple BLUETOOTH devices Procedure: 1. Danger to life due to high voltages Ensure that the inverter is disconnected from all voltage sources (see Section 10, page 45 ). 2. To set a new NetID, set the rotary switch C to the determined NetID using a flat-blade screwdriver (blade width: 2.5 mm). 3. To deactivate communication via BLUETOOTH, set the rotary switch C to position 0 using a flatblade screwdriver (blade width: 2.5 mm). This will protect your PV system from unauthorized access. The inverter will adopt the setting after commissioning. This can take up to five minutes. Operating Manual SB30-50TL-21-BE-en-11 33
34 7 Commissioning SMA Solar Technology AG 7.4 Commissioning the Inverter Requirements: The inverter must be correctly mounted. The circuit breaker must be correctly rated and mounted. All cables must be completely and correctly connected. Unused DC inputs must be sealed using the corresponding DC connectors and sealing plugs. The country data set must be set correctly for the country or the purpose. Procedure: 1. Insert the lower enclosure lid from above and flip it down. The screws must protrude from the lower enclosure lid. 2. Tighten all screws of the lower enclosure lid using an Allen key (AF 3) in the order 1 to 6 (torque: 2 Nm ± 0.3 Nm). Useful hint: If the screws fall out of the lower enclosure lid, insert the short screw in the upper middle hole and the five long screws in the other holes. 3. If the ESS is available, plug it in. The ESS must be aligned parallel to and flush with the enclosure. 4. Currents in the DC cabling after plugging in the ESS After plugging in the ESS, DC currents may occur in the DC cabling, even when there is no AC-side supply. This is not an error but normal behavior of the inverter when in operation. 5. Attach the supplied warning labels so that they are clearly visible on the disconnection point on the AC side. 6. Switch on the circuit breaker. 7. If an external DC load-break switch is installed, switch it on. 8. If the multifunction relay is used, connect the supply voltage to the load. All three LEDs start to glow and the start-up phase begins. The start-up phase may take several minutes. 34 SB30-50TL-21-BE-en-11 Operating Manual
35 SMA Solar Technology AG 7 Commissioning Self-test in accordance with CEI 0-21 during commissioning (applies to Italy only) The Italian standard prescribes that an inverter can only be operated on the utility grid after the disconnection times for overvoltage, undervoltage, minimum frequency and maximum frequency have been checked. If the country data set is configured to CEI 0-21 Int / CEI 0-21 internal, start the self-test as soon as the display shows the country data set (see Section "Starting the Self- Test", page 35). The green LED is glowing and the display alternates automatically between the device type, firmware version, the serial number or designation of the inverter, the NetID, the configured country data set and the display language. The green LED is flashing? Possible cause of error: the DC input voltage is still too low or the inverter is monitoring the utility grid. Once the DC input voltage is sufficiently high and the grid-connection conditions are met, the inverter will start operation. The red LED is glowing and an error message and event number appear in the display? An error has occurred. Rectify the error (see service manual at Self-Test in Accordance with CEI 0-21 for PV Systems 6 kw Starting the Self-Test The self-test only applies to inverters that are configured with the country data set CEI 0-21 Int or CEI 0-21 internal. The self-test is only valid for inverters licensed for Italy and configured with the country data set CEI 0-21 Int or CEI 0-21 internal. If the inverter is configured to the country data set CEI 0-21 Ext or CEI 0-21 external, no self-test is required. The self-test is only required for inverters to be commissioned in Italy. The Italian standard requires that all inverters feeding into the utility grid are equipped with a self-test function in accordance with CEI During the self-test, the inverter will consecutively check the reaction times for overvoltage, undervoltage, maximum frequency and minimum frequency. The self-test changes the upper and lower disconnection values for each protective function on a linear basis for frequency monitoring and voltage monitoring. As soon as the measured value exceeds the permitted disconnection threshold, the inverter disconnects from the utility grid. In this way, the inverter determines the reaction time and checks itself. After the self-test has been completed, the inverter automatically switches back to feed-in operation, resets the original disconnection conditions and connects to the utility grid. The test takes approximately three minutes. Operating Manual SB30-50TL-21-BE-en-11 35
36 7 Commissioning SMA Solar Technology AG Requirements: Configured country data set: CEI 0-21 Int or CEI 0-21 internal or amended country data set trimmed or Special setting based on one of the country data sets mentioned above. A report for entering the test results according to CEI 0-21 must be available. The inverter must be in operation and in the start-up phase. Procedure: 1. As soon as the configured country data set appears in the display, tap once on the display within ten seconds. A message informing you that the self-test has started is shown in the display: Avvio Autotest. The message Avvio Autotest is not shown in the display? The ten seconds have elapsed so the self-test cannot start. Restart the self-test (see Section 7.5.2, page 36). 2. Tap on the display within 20 seconds and enter the subsequent test results into the test report. The self-test starts. The inverter displays the results of the individual tests for overvoltage, undervoltage, maximum frequency and minimum frequency. The results are displayed three times in succession for ten seconds each. Useful hint: If you want to have the next result displayed without waiting ten seconds, tap twice on the enclosure lid. The information Autotest interroto is shown in the display? The self-test was cancelled due to an unexpected disconnection condition or the DC voltage is too low to continue grid feed-in. Restart the self-test (see Section 7.5.2, page 36). Example: Display messages for overvoltage test - Name of the test: Autotest (59.S1) V - Disconnection value: Valore di soglia con V - Normative value: Va. taratura V - Disconnection time: Tempo die intervento 0.02 s - Current grid voltage: Tensione di rete Val.eff.: V Restarting the Self-Test 1. Disconnect the circuit breaker and secure it against reconnection. 2. If the multifunction relay is used, disconnect the supply voltage to the load. 3. If an external DC load-break switch is used, switch it off for five minutes and then switch it on again. 36 SB30-50TL-21-BE-en-11 Operating Manual
37 SMA Solar Technology AG 7 Commissioning 4. If an ESS is in use, pull it out of the inverter for five minutes and then plug it in again firmly. 5. Recommission the inverter. The inverter is back in the start-up phase and you can start the self-test once again (see Section 7.5.1, page 35). Operating Manual SB30-50TL-21-BE-en-11 37
38 8 Configuration SMA Solar Technology AG 8 Configuration 8.1 Configuration Procedure Once you have commissioned the inverter, you may have to adjust various settings via the rotary switches in the inverter or via a communication product. This section describes the procedure for configuration and gives an overview of the steps you must perform in the prescribed order. Procedure 1. If the display language is not set correctly, adjust the settings. 2. In order to use the Webconnect function, integrate the inverter into the network. 3. To manage the PV system data or to set the inverter parameters, capture the inverter in a communication product. 4. In order to receive control commands of the grid operator via SMA Speedwire/Webconnect for PV systems in Italy, set the parameters. See Section 8.2, page 38 Section 8.3, page 39 Manual of the communication product at Solar.com Manual of the Speedwire/ Webconnect interface 5. Change the system time and system password. Manual of the communication product at Solar.com 6. If the inverter is installed in an IT network or another grid configuration where deactivation of the grounding conductor monitoring is required, deactivate the grounding conductor monitoring. 7. For partially shaded PV modules and depending on the given shading situation, you should set the interval at which the inverter optimizes the MPP of the PV system. 8.2 Changing the Display Language Section 8.5, page 40 Section 8.6, page 40 If the language for the country data set is not the language you want to use, you can change the display language as follows: Procedure: 1. Danger to life due to high voltages Disconnect the inverter from all voltage sources and open the enclosure lid (see Section 10, page 45). 38 SB30-50TL-21-BE-en-11 Operating Manual
39 SMA Solar Technology AG 8 Configuration 2. Determine the rotary switch setting for the desired display language. Call up the Technical Information "Overview of the Rotary Switch Settings" at 3. Set the rotary switch A to 0 using a flat-blade screwdriver (blade width: 2.5 mm). This ensures that the selected data country set remains unchanged. 4. Set the rotary switch B to the required language using a flat-blade screwdriver (blade width: 2.5 mm). 5. Recommission the inverter (see service manual at The inverter adopts the settings after commissioning. This can take up to five minutes. 8.3 Integrating the Inverter into the Network If the router supports DHCP and DHCP is enabled, the inverter will automatically be integrated into the network. You will not need to carry out network configuration. If the router does not support DHCP, automatic network configuration will not be possible and you will need to use the SMA Connection Assist to integrate the inverter into the network. Requirements: The inverter must be in operation. There must be a router with Internet connection in the local network of the system. The inverter must be connected to the router. Procedure: Integrate the inverter into the network by means of the SMA Connection Assist. Download the SMA Connection Assist and install it on the computer (see Changing Operating Parameters This section describes the basic procedure for changing operating parameters. Always change operating parameters as described in this section. Some parameters that have sensitive functions can only be viewed and changed by qualified persons (for further information on changing parameters, refer to the manual of the communication product). The operating parameters of the inverter are set to certain values by default. To optimize inverter operation, you can change the operating parameters using a communication product. Requirements: Depending on the type of communication, a computer with BLUETOOTH or Ethernet interface must be available. Operating Manual SB30-50TL-21-BE-en-11 39
40 8 Configuration SMA Solar Technology AG A communication product corresponding to the type of communication used must be available. The inverter must be registered in the communication product. The changes to the grid-relevant parameters must be approved by the responsible grid operator. When changing grid-relevant parameters, the SMA Grid Guard code must be available (see "Application for SMA Grid Guard Code" at Procedure: 1. Call up the user interface of the communication product or software and log in as Installer or User. 2. If required, enter the SMA Grid Guard code. 3. Select and set the required parameter. 4. Save settings. 8.5 Deactivating Grounding Conductor Monitoring If the inverter is to be installed in an IT network or another grid configuration in which deactivation of the grounding conductor monitoring is required, deactivate the grounding conductor monitoring as follows. The basic procedure for changing operating parameters is explained in another section (see Section 8.4 "Changing Operating Parameters", page 39). Procedure: Set the parameter PE connection monitoring or PEOpnMon to Off. 8.6 Setting SMA OptiTrac Global Peak For partially shaded PV modules, you should set the interval at which the inverter is to optimize the MPP of the PV system. The basic procedure for changing operating parameters is explained in another section (see Section 8.4 "Changing Operating Parameters", page 39). Procedure: Select the parameter Cycle time of the OptiTrac Global Peak algorithm or MPPShdw.CycTms and set the required time interval. The ideal time interval is usually six minutes. This value should only be increased if the shading situation changes extremely slowly. The inverter optimizes the MPP of the PV system at the predetermined time interval. 40 SB30-50TL-21-BE-en-11 Operating Manual
41 SMA Solar Technology AG 9 Operation 9 Operation 9.1 LED Signals The LEDs indicate the operating state of the inverter. LED Status Explanation Green LED glowing Feed-in operation If an event occurs during feed-in operation, an event message will be shown on the display (for event messages see the service manual at flashing The conditions for feed-in operation are not yet met. As soon as the conditions are met, the inverter will start feedin operation. Red LED glowing Error If an error occurs, the error message and the corresponding event number will be shown in the display. The error must be rectified by a qualified person (for troubleshooting, see the service manual at Blue LED glowing BLUETOOTH communication is activated. 9.2 Display Overview The display shows the current operating data of the inverter (e.g. current power, daily energy, total energy) as well as events or errors. Power and energy are displayed as bars in a diagram. Operating Manual SB30-50TL-21-BE-en-11 41
42 9 Operation SMA Solar Technology AG There is a slot for an SD memory card on the left edge of the display enclosure. You can use the SD memory card to carry out an inverter firmware update, for example (for information on firmware updates with an SD memory card see the technical description "Firmware Update with SD Card" at Figure 9: Layout of the display (example) Position Symbol Explanation A - Current power B - Energy on the current day C - Total amount of energy fed in 42 SB30-50TL-21-BE-en-11 Operating Manual
43 SMA Solar Technology AG 9 Operation Position Symbol Explanation D Active BLUETOOTH connection Quality of the BLUETOOTH connection Active connection to a Speedwire network Active connection to Sunny Portal Multifunction relay is active Power limitation due to excessive temperature Active power limitation via PV system control E - Line conductor to which the displayed values apply F Utility grid G - Event number of an error on the utility grid side H - Output voltage or output current of a line conductor I - Event number of an error in the inverter K L Grid relay When the grid relay is closed, the inverter feeds into the utility grid. When the grid relay is open, the inverter is disconnected from the utility grid. Inverter M - Input voltage or input current of a line conductor N - Event number of an error on the PV array side O - Text line to display event and error messages P PV Array Operating Manual SB30-50TL-21-BE-en-11 43
44 9 Operation SMA Solar Technology AG Position Symbol Explanation Q - Diagram with the power curve of the last 16 feed-in hours or energy yields of the last 16 days In order to switch between diagrams, tap once on the enclosure lid. R You can operate the display by tapping on the enclosure lid (see Section 9.3, page 44). The displayed error must be rectified on-site by a qualified person (for troubleshooting, see service manual at The displayed error cannot be rectified on-site. Contact Service (see Section 13, page 55). 9.3 Activating and Operating the Display You can activate and operate the display by tapping on the enclosure lid. Procedure: 1. Activate the display. Tap on the enclosure lid once. The backlight is switched on. 2. To move to the next line, tap on the enclosure lid once. 3. In order to switch between the power curve of the last 16 feed-in hours and the energy yields of the last 16 days in the diagram, tap on the enclosure lid once. 9.4 Calling Up Display Messages of the Start-Up Phase Various inverter information is displayed during the start-up phase that can be called up whenever required during operation. Procedure: Tap on the enclosure lid twice. The display shows all messages of the start-up phase in sequence. 44 SB30-50TL-21-BE-en-11 Operating Manual
45 SMA Solar Technology AG 10 Disconnecting the Inverter from Voltage Sources 10 Disconnecting the Inverter from Voltage Sources Prior to performing any work on the inverter, always disconnect it from all voltage sources as described in this section. Always adhere to the prescribed sequence. Destruction of the measuring device due to overvoltage Only use measuring devices with a DC input voltage range of 1,000 V or higher. Procedure: 1. Disconnect the circuit breaker and secure it against reconnection. 2. If an additional DC load-break switch is available, switch off the DC load-break switch and secure against re-connection. 3. If an ESS is plugged in, remove the ESS. 4. If the multifunction relay is used, switch off any supply voltage to the load. 5. Wait until the LEDs, the display and if necessary, the load connected to the multifunction relay, are switched off. 6. Use a current clamp to ensure that no current is present in the DC cables. 7. Remove all screws of the lower enclosure lid using an Allen key (AF 3) and remove the enclosure lid. 8. Release and remove all DC connectors. Insert a slotted screwdriver or an angled screwdriver (blade width 3.5 mm) into one of the slide slots and pull the DC connectors out downwards. Do not pull on the cable. 9. Ensure that no voltage is present at the DC inputs of the inverter. 10. Use a suitable measuring device to check that no voltage is present at the AC connecting terminal plate between L and N and L and PE. Insert the test probe (maximum diameter: 2 mm) in each round opening of the terminal. 11. Flip the display up to have more space to make the measurement. Loosen the screw on the display. The display clicks into place. 12. Ensure that no voltage is present between any terminal of the multifunction relay and PE of the AC connecting terminal plate. Operating Manual SB30-50TL-21-BE-en-11 45
46 10 Disconnecting the Inverter from Voltage Sources SMA Solar Technology AG 13. Damage to the inverter due to electrostatic discharge The internal components of the inverter can be irreparably damaged by electrostatic discharge. Ground yourself before touching any component. 46 SB30-50TL-21-BE-en-11 Operating Manual
47 SMA Solar Technology AG 11 Technical Data 11 Technical Data 11.1 DC/AC Sunny Boy 3000TL / 3600TL DC Input SB 3000TL-21 SB 3600TL-21 Maximum DC power at cos φ = 1 3,200 W 3,880 W Maximum input voltage 750 V 750 V MPP voltage range 175 V to 500 V 175 V to 500 V Rated input voltage 400 V 400 V Minimum input voltage 125 V 125 V Initial input voltage 150 V 150 V Maximum input current, input A 15 A 15 A Maximum input current, input B 15 A 15 A Maximum short-circuit current per input* 20 A 20 A Maximum reverse current from the inverter in the system for max. 1 ms 0 A 0 A Number of independent MPP inputs 2 2 Strings per MPP input 2 2 Overvoltage category in accordance with IEC * In accordance with IEC : I SC PV AC Output II SB 3000TL-21 II SB 3600TL-21 Rated power at 230 V, 50 Hz 3,000 W 3,680 W Maximum apparent AC power 3,000 VA 3,680 VA Rated grid voltage 230 V 230 V Nominal AC voltage 220 V / 230 V / 240 V 220 V / 230 V / 240 V AC voltage range* 180 V to 280 V 180 V to 280 V Nominal AC current at 220 V 13.6 A 16.0 A Nominal AC current at 230 V 13.0 A 16.0 A Nominal AC current at 240 V 12.5 A 15.3 A Operating Manual SB30-50TL-21-BE-en-11 47
48 11 Technical Data SMA Solar Technology AG SB 3000TL-21 SB 3600TL-21 Maximum output current 16 A 16 A Total harmonic distortion of the output current with total harmonic distortion of the AC voltage < 2%, and AC power > 50% of the rated power Inrush current 4% 4% < 20% of the nominal AC current for a maximum of 10 ms < 20% of the nominal AC current for a maximum of 10 ms Maximum output current under fault conditions 34 A 34 A Rated power frequency 50 Hz 50 Hz AC power frequency* 50 Hz / 60 Hz 50 Hz / 60 Hz Operating range at AC power frequency 50 Hz 45 Hz to 55 Hz 45 Hz to 55 Hz Operating range at AC power frequency 60 Hz 55 Hz to 65 Hz 55 Hz to 65 Hz Power factor at rated power 1 1 Displacement power factor cos φ, adjustable 0.8 underexcited to 1 to 0.8 overexcited 0.8 underexcited to 1 to 0.8 overexcited Feed-in phases 1 1 Connection phases 1 1 Overvoltage category in accordance with IEC * depending on the configured country data set Efficiency III SB 3000TL-21 III SB 3600TL-21 Maximum efficiency, η max 97.0% 97.0% European weighted efficiency, η EU 96.0% 96.4% Sunny Boy 4000TL / 5000TL DC Input SB 4000TL-21 SB 5000TL-21 Maximum DC power at cos φ = 1 4,200 W 5,200 W Maximum input voltage 750 V 750 V MPP voltage range 175 V to 500 V 175 V to 500 V Rated input voltage 400 V 400 V Minimum input voltage 125 V 125 V 48 SB30-50TL-21-BE-en-11 Operating Manual
49 SMA Solar Technology AG 11 Technical Data SB 4000TL-21 SB 5000TL-21 Initial input voltage 150 V 150 V Maximum input current, input A 15 A 15 A Maximum input current, input B 15 A 15 A Maximum short-circuit current per input* 20 A 20 A Maximum reverse current from the inverter in the system for max. 1 ms 0 A 0 A Number of independent MPP inputs 2 2 Strings per MPP input 2 2 Overvoltage category in accordance with IEC * In accordance with IEC : I SC PV AC Output II SB 4000TL-21 II SB 5000TL-21 Rated power at 230 V, 50 Hz 4,000 W 4,600 W Maximum apparent AC power 4,000 VA 5,000 VA Rated grid voltage 230 V 230 V Nominal AC voltage 220 V / 230 V / 240 V 220 V / 230 V / 240 V AC voltage range* 180 V to 280 V 180 V to 280 V Nominal AC current at 220 V 18.2 A 20.9 A Nominal AC current at 230 V 17.4 A 20.0 A Nominal AC current at 240 V 16.7 A 19.2 A Maximum output current 22 A 22 A Total harmonic distortion of the output current with total harmonic distortion of the AC voltage < 2%, and AC power > 50% of the rated power Inrush current 4% 4% < 20% of the nominal AC current for a maximum of 10 ms < 20% of the nominal AC current for a maximum of 10 ms Maximum output current under fault conditions 34 A 34 A Rated power frequency 50 Hz 50 Hz AC power frequency* 50 Hz / 60 Hz 50 Hz / 60 Hz Operating range at AC power frequency 50 Hz 45 Hz to 55 Hz 45 Hz to 55 Hz Operating Manual SB30-50TL-21-BE-en-11 49
50 11 Technical Data SMA Solar Technology AG SB 4000TL-21 SB 5000TL-21 Operating range at AC power frequency 60 Hz 55 Hz to 65 Hz 55 Hz to 65 Hz Power factor at rated power 1 1 Displacement power factor cos φ, adjustable 0.8 underexcited to 1 to 0.8 overexcited 0.8 underexcited to 1 to 0.8 overexcited Feed-in phases 1 1 Connection phases 1 1 Overvoltage category as per IEC III III * depending on the configured country data set Efficiency SB 4000TL-21 SB 5000TL-21 Maximum efficiency, η max 97.0% 97.0% European weighted efficiency, η EU 96.4% 96.5% 11.2 General Data Width x height x depth, without Electronic Solar Switch Width x height x depth, with Electronic Solar Switch Weight Length x width x height of the packaging Transport weight Climatic category in accordance with IEC Environmental category 490 mm x 490 mm x 185 mm 490 mm x 519 mm x 185 mm 26 kg 597 mm x 617 mm x 266 mm 30 kg 4K4H Outdoors Pollution degree outside the enclosure 3 Pollution degree inside the enclosure 2 Operating temperature range Maximum permissible value for relative humidity, non-condensing Maximum operating altitude above mean sea level (MSL) Typical noise emission Power loss in night mode -25 C to +60 C 100% 2,000 m 25 db(a) <1 W 50 SB30-50TL-21-BE-en-11 Operating Manual
51 SMA Solar Technology AG 11 Technical Data Maximum data volume per inverter with Speedwire/Webconnect Additional data volume when using the Sunny Portal live interface Topology Cooling method Degree of protection for electronics in accordance with IEC Protection class in accordance with IEC Grid configurations* Approvals and national standards, as per 10/2014** 550 MB/month 660 kb/hour Transformerless Convection IP65 I IT, Delta-IT, TN-C, TN-S, TN-C-S, split phase, TT (if V N_PE < 20 V) AS4777:2005, CE, CEI 0-21, C10/11:2012, DIN EN , EN 50438:2013, G59/3, G83/2, IEC 61727, IEC , IEC , IEC 62116, NRS , PPC, PPDS, RD 661/2007, RD 1699:2011, SI4777, TOR D4, VDE , VDE :2006, VDE / UTE C , VDE-AR- N 4105, VFR 2014 * IT, Delta-IT: When using in these systems, the grounding conductor monitoring must be deactivated and an additional grounding connected to the inverter. ** EN 50438: does not apply to all national appendices of EN IEC : This standard requires that either the multifunction relay in the inverter is used as fault indicator or that the inverter is connected to Sunny Portal and that the fault alert is activated in Sunny Portal. NRS : This standard requires a separate label attached to the AC distribution board which indicates the AC-side disconnection of the inverter in case of a grid failure (for further details, see NRS , Sect and ) RD 661/2007, RD 1699:2011:Contact the Service for restrictions in specific regions(see Section 13, page 55) Protective Devices DC reverse polarity protection Input-side disconnection point DC overvoltage protection AC short-circuit current capability Short-circuit diode Electronic Solar Switch, SUNCLIX DC connector Thermally monitored varistors Current control Grid monitoring SMA Grid Guard 3 Maximum permissible fuse protection for SB 3000TL A Operating Manual SB30-50TL-21-BE-en-11 51
52 11 Technical Data SMA Solar Technology AG Maximum permissible fuse protection for SB 3600TL-21 Maximum permissible fuse protection for SB 4000TL-21 Maximum permissible fuse protection for SB 5000TL-21 Ground-fault monitoring for SB 3000TL-21 Ground-fault monitoring for SB 3600TL-21 Ground-fault monitoring for SB 4000TL-21 Ground-fault monitoring for SB 5000TL-21 All-pole sensitive residual-current monitoring unit 32 A 32 A 32 A Insulation monitoring: R iso > 625 kω Insulation monitoring: R iso > 550 kω Insulation monitoring: R iso > 500 kω Insulation monitoring: R iso > 400 kω Available 11.4 Climatic Conditions Installation in accordance with IEC , Class 4K4H Extended temperature range -25 C to +60 C Extended humidity range 0% to 100% Extended air pressure range 79.5 kpa to 106 kpa Transport in accordance with IEC , Class 2K3 Temperature range -25 C to +70 C 11.5 Equipment DC connection AC connection Display BLUETOOTH Speedwire/Webconnect data module RS485, galvanically isolated Multifunction relay SMA Power Control Module 11.6 Torques Upper enclosure lid screws Lower enclosure lid screws SUNCLIX DC connector Spring-cage terminal LC graphic display As standard As standard Optional Optional Optional 6 Nm ± 0.3 Nm 2 Nm ± 0.3 Nm 52 SB30-50TL-21-BE-en-11 Operating Manual
53 SMA Solar Technology AG 11 Technical Data Additional grounding SUNCLIX swivel nut RS485 communication or Speedwire/Webconnect connection Multifunction relay connection 6.0 Nm 2.0 Nm 1.5 Nm 1.5 Nm 11.7 Electronic Solar Switch Electrical endurance in the event of short circuit, at nominal current of 35 A Maximum switching current Maximum switching voltage At least 50 switching operations 35 A 800 V Maximum power 12 kw Degree of protection when plugged in Degree of protection when unplugged Fuses for Electronic Solar Switch IP65 IP21 F200, 600 V/4 A, fast acting and F201, 600 V / 4 A, fast acting (soldered, not replaceable) 11.8 Data Storage Capacity Energy yields in the course of the day Daily yields Event messages for users Event messages for installers 63 days 30 years 250 events 250 events Operating Manual SB30-50TL-21-BE-en-11 53
54 12 Accessories SMA Solar Technology AG 12 Accessories You will find the accessories for your product in the following overview. If required, these can be ordered from SMA Solar Technology AG or your distributor. Designation Brief description SMA order number RS485 data module RS458 interface as retrofit kit DM-485CB-10 SMA Power Control Module Multifunction interface for implementing grid management systems for one inverter PWCMOD-10 Multifunction relay Multifunction relay as retrofit kit MFR01-10 Fan retrofit kit Fan to be installed in the inverter for supplementary cooling FANKIT SB30-50TL-21-BE-en-11 Operating Manual
55 SMA Solar Technology AG 13 Contact 13 Contact If you have technical problems with our products, contact the SMA Service Line. We need the following information in order to provide you with the necessary assistance: Inverter device type Inverter serial number Inverter firmware version Special country-specific settings of the inverter (if applicable) Type and quantity of PV modules connected Mounting location and altitude of the inverter Inverter message Optional equipment, e.g. communication products Operating mode of the multifunction relay (if present) Australia Belgien/Belgique/België Brasil Česko Chile Danmark Deutschland España SMA Australia Pty Ltd. Sydney SMA Benelux BVBA/SPRL Mecheln Vide España (Espanha) SMA Central & Eastern Europe s.r.o. Praha Ver España Se Deutschland (Tyskland) SMA Solar Technology AG Niestetal SMA Ibérica Tecnología Solar, S.L.U. Barcelona Toll free for Australia: 1800 SMA AUS ( ) International: Medium Power Solutions Wechselrichter: Kommunikation: SMA Online Service Center: Hybrid Energy Solutions Sunny Island: PV-Diesel Hybridsysteme: Power Plant Solutions Sunny Central: Llamada gratuita en España: Internacional: Operating Manual SB30-50TL-21-BE-en-11 55
56 13 Contact SMA Solar Technology AG France India Italia Κύπρος/Kıbrıs Luxemburg/ Luxembourg SMA France S.A.S. Lyon SMA Solar India Pvt. Ltd. Mumbai SMA Italia S.r.l. Milano Βλέπε Ελλάδα/ Bkz. Ελλάδα (Yunanistan) Siehe Belgien Voir Belgique Magyarország lásd Česko (Csehország) Nederland Österreich Perú Polska Portugal România Schweiz Slovensko South Africa United Kingdom Ελλάδα България zie Belgien (België) Siehe Deutschland Ver España Patrz Česko (Czechy) SMA Solar Technology Portugal, Unipessoal Lda Lisboa Vezi Česko (Cehia) Siehe Deutschland pozri Česko (Česká republika) SMA Solar Technology South Africa Pty Ltd. Centurion (Pretoria) SMA Solar UK Ltd. Milton Keynes SMA Hellas AE Αθήνα Вижте Ελλάδα (Гърция) Medium Power Solutions Onduleurs : Communication : Hybrid Energy Solutions Sunny Island : Power Plant Solutions Sunny Central : Gratuito em Portugal: Internacional: SUNNY ( ) International: +27 (12) International: SB30-50TL-21-BE-en-11 Operating Manual
57 SMA Solar Technology AG SMA Solar (Thailand) Co., Ltd Contact 대한민국 SMA Technology Korea Co., Ltd. 서울 SMA Middle East LLC Middle East LLC Other countries International SMA Service Line Niestetal Toll free worldwide: SMA SERVICE ( ) Operating Manual SB30-50TL-21-BE-en-11 57
58 14 EC Declaration of Conformity SMA Solar Technology AG 14 EC Declaration of Conformity within the meaning of the EC directives 2004/108/EG (Electromagnetic compatibility, EMC) 2006/95/EG (Low voltage directive) 1999/5/EC (Radio and Telecommunications Terminal Equipment, R&TTE) SMA Solar Technology AG confirms herewith that the inverters described in this document are in compliance with the fundamental requirements and other relevant provisions of the abovementioned directives. The entire EC Declaration of Conformity can be found at Solar.com. 58 SB30-50TL-21-BE-en-11 Operating Manual
59
60 SMA Solar Technology
Operating Manual SUNNY BOY 1.5 / 2.5
Operating Manual SUNNY BOY 1.5 / 2.5 SB15-25-BE-en-10 Version 1.0 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in these documents is property of SMA Solar
Accessories SUNNY REMOTE CONTROL
Accessories SUNNY REMOTE CONTROL Mounting Instructions SRC20-MO-IEN121010 IMEN-SRC20 Version 1.0 EN SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This
Communication interface for SMA inverters SMA WEBCONNECT DATA MODULE
Communication interface for SMA inverters SMA WEBCONNECT DATA MODULE Installation Manual A B FA: FA: xxxxx xxxxx SER: SER: xx xx SPWDM-10.BG1 SPWDM-10.BG1 WebconnectDM-IA-IEN122510 98-0051210 Version 1.0
PV Inverter SUNNY BOY 3000TL / 3600TL / 4000TL / 5000TL
PV Inverter SUNNY BOY 3000TL / 3600TL / 4000TL / 5000TL Installation Manual SB30-50TL-21-IA-en-20 IMEN-SBXTL-21 Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Information
Ambient Temperature Sensor TEMPSENSOR-AMBIENT
Ambient Temperature Sensor TEMPSENSOR-AMBIENT Installation Guide TempsensorAmb-IEN110610 98-0042210 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Guide...............................
Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK
Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK Installation Guide BTPB-IEN112112 98-0014212 Version 1.2 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this
Firmware Update with SD Card SUNNY BOY WINDY BOY SUNNY TRIPOWER
Firmware Update with SD Card SUNNY BOY WINDY BOY SUNNY TRIPOWER Technical Description NG_UpdSD-TB-en-32 Version 3.2 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this
Operating Manual SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H SUNNY REMOTE CONTROL
Operating Manual SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H SUNNY REMOTE CONTROL SI30M-44M-60H-80H-BE-en-32 Version 3.2 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained
Installation Manual SMA CLUSTER CONTROLLER
Installation Manual SMA CLUSTER CONTROLLER ClusterController-IA-en-15 Version 1.5 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in these documents is property
PV Inverter SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL
PV Inverter SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL Installation Manual STP8-17TL-IA-en-31 IMEN-STP10-17TL Version 3.1 EN SMA Solar Technology AG Table of Contents Table of Contents
Sunny Boy Accessories SMA POWER BALANCER
Sunny Boy Accessories SMA POWER BALANCER Installation Guide SBUS-PowBal-IUS102810 IMUS-SBUS-PBL Version 1.0 US SMA America, LLC Legal Restrictions Copyright 2010 SMA America, LLC. All rights reserved.
Operating Manual POWER PLANT CONTROLLER
Operating Manual POWER PLANT CONTROLLER PPC-BE-P7-en-13 98-113900.02 Version 1.3 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in this document is the property
PV Inverter SUNNY TRIPOWER 8000TL/10000TL/12000TL/15000TL/17000TL
PV Inverter SUNNY TRIPOWER 8000TL/10000TL/12000TL/15000TL/17000TL Installation Guide STP8-17TL-IEN110121 IMEN-STP10-17TL Version 2.1 EN Power curve of the past 16 feed-in hours or past 16 days (switching
SUNNY TRIPOWER 5000TL 12000TL
SUNNY TRIPOWER 5000TL 12000TL STP 5000TL-20 / STP 6000TL-20 / STP 7000TL-20 / STP 8000TL-20 / STP 9000TL-20 / STP 10000TL-20 / STP 12000TL-20 NEW available as 10 kva and 12 kva versions Economical Flexible
Communication Interface for SMA Inverters SMA SPEEDWIRE/WEBCONNECT DATA MODULE
Communication Interface for SMA Inverters SMA SPEEDWIRE/WEBCONNECT DATA MODULE Installation Manual A B FA: FA: xxxxx xxxxx SER: SER: xx xx SPWDM-10.BG1 SPWDM-10.BG1 SWWEBCONDM-IA-en-11 98-0051211 Version
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
Service Manual SUNNY BOY 3000TL / 3600TL / 4000TL / 5000TL / 6000TL
Service Manual SUNNY BOY 3000TL / 3600TL / 4000TL / 5000TL / 6000TL SB30-60TL-21-SG-en-11 Version 1.1 AMERICAN ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained
How To Set Up An Inverter
MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS Installation Guide GSM Option Kit FLX series www.danfoss.com/solar Safety Safety Safety Message Types WARNING Safety information important for human safety.
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V
Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................
Solar Inverter Sunny Boy 5000US, 6000US, 7000US
Solar Inverter Sunny Boy 5000US, 6000US, 7000US Installation Guide SB50US-70US-IUS090523 TBUS-SB50_60_70US Version 2.3 US Copyright 2008 SMA America, Inc. All rights reserved. No part of this document
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
KNX R. Rain Sensor. Installation and Adjustment
EN KNX R Rain Sensor Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical specifications... 3 2. Installation and commissioning... 4 2.1. Installation notes... 4 2.2. Location... 4
Replacement Instructions. Warning: During this procedure, keep small parts away from children.
apple ibook G4 Memory Card Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Written
Mounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en
Mounting instructions Junction box VKK2R-8 DIGITAL VKK2R-8 DIGITAL 3 Contents Page Safety instructions... 4 1 Introduction and appropriate use... 7 2 Mechanical construction... 8 2.1 Mounting... 9 3 Electrical
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
RAY-MAX Integrated Solar Power Strip
RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...
Battery Power Inverters
Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.1 Important Safety Instructions Please save these instructions.
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar
Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
OPLC Installation Guide
Samba OPLC SM43-J-T20/ SM35-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs are set to pnp), 8 Relay Outputs 12 Digital
Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V
Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
YSmart Technology Co.,Ltd
YSmart Technology Co.,Ltd GWV Series Grid Tie Microinverter User Manual The copyright of this user manual belong to YSmart TechnologyCompany Limited. Without the written permission of the copyright holder,
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet
Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit
Installation Instructions PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit ATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on the power structure
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
KeContact P20 User manual
KeContact P20 User manual General notes for this manual At various points in this manual you will see notes and precautionary warnings regarding possible hazards. The symbols used have the following meanings:!!!
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
AMERBRITE UNDERWATER WHITE LED POOL LAMP
AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY WITH PENTAIR AMERLITE LUMINAIRE INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
Rousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to
2M IR Mini Dome Quick Installation Guide
2M IR Mini Dome 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
Model 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
LED MOTION ACTIVATED FLOOD LIGHT
Utilitech & UT Design are registered trademarks of LF, LLC. All Rights Reserved. ITEM #0611551, #0611550 LED MOTION ACTIVATED FLOOD LIGHT MODEL #SE1036-BP2-02LF0-U, SE1036-WH3-02LF0-U Français p. 10 Español
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
UniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
804 Ti Stand. Manual 8.804.8001EN
804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware
GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual
GreenWay Solar LED Path and Trail Lighting System Installation and Owner s Manual Important Notes and Warnings This installation and instruction manual provides installation, operation, and maintenance
SUNNY BOY 2000HF / 2500HF / 3000HF
SUNNY BOY 2000HF / 2500HF / 3000HF A New Dimension SUNNY BOY 2000HF / 2500HF / 3000HF A NEW DIMENSION AMAZINGLY SIMPLE. REASSURINGLY EFFICIENT. Do you want promising prospects? Then the Sunny Boy HF is
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
