The Problem Solving of Exhaust Frame Air Cooling System Pressure Low in GE Frame 9 Gas Turbine



Similar documents
Mechanical kiln inspection. Improves and ensures kiln availability by optimisation of: Kiln axis Kiln shell ovality Axial balance Kiln crank

Lifetime Extension for SIEMENS Gas Turbines

1.3 Turbochargers are categorised in three groups depending on served power by cylinder groups with:

Low Load Operational Flexibility for Siemens G-class Gas Turbines

Gas Turbine Metallurgy, Coatings and Repair Technology Workshop May 2 nd, 2010

Siemens Steam Turbine-Generator SST-5000 Series. for combined cycle and subcritical steam applications. Answers for energy.

WHAT IS INFRARED (IR) THERMOGRAPHY

Chapter 5 - Aircraft Welding

Originators of the Flexible Water Tube design

HAZARD RISK ASSESSMENT

THERMAL POWER PLANTS Vol. III - Gas Turbines For Electric Power Generation - H.I.H. Saravanamuttoo GAS TURBINES FOR ELECTRIC POWER GENERATION

QUADRANT SR- Thermal Oxidizer Process Design & Environmental Control Benefits for the Sand Coating Industries

Bearing Failure: Causes and Cures

Sulzer Turbo Services

Performance Monitoring For Gas Turbines

Maintenance and Service Instruction

Operational Flexibility Enhancements of Combined Cycle Power Plants. Dr. Norbert Henkel, Erich Schmid and Edwin Gobrecht

OVERVIEW OF GENERAL ELECTRIC S ADVANCED TURBINE SYSTEMS PROGRAM

Coal Handling Plant Alignment Standards For Shaft To Shaft Alignment. By Makarand Joshi M.Tech

SGT-800 GAS TURBINE CONTINUED AVAILABILITY AND MAINTAINABILITY IMPROVEMENTS. Dr. Vladimir Navrotsky Lena Strömberg Claes Uebel

Integrated Asset Management at REGCO, Thailand

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

Source: EIA Natural Gas Issues and Trends 1998

Siemens Gas Turbines over 100 MW

Turbine Optimization Programs to Extend Outage Periods and Manage Equipment Breakdown Risk

F.I.R.S.T. Gas Turbine End of Life Presentation

due to uncertainty. This, in turn, has a direct impact on equipment availability and maintenance costs. Unfortunately, due to misconceptions and

TITANIUM FABRICATION CORP.

Gas turbine performance and maintenance continuous improvement

A Study of Durability Analysis Methodology for Engine Valve Considering Head Thermal Deformation and Dynamic Behavior

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine.

Boiler Preparation, Start-Up and Shutdown

Reliability. The Essentials of Eliminating Downtime of your Electric Motor. Asset Management? Or, Maintenance Management, Re-branded?

AIRWORTHINESS BULLETIN

Diagnostics for Mobile Homes: HVAC

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

GENERAL PROPERTIES //////////////////////////////////////////////////////

North American Stainless

Company Profile. New and overhauled Power Plants for sale

TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES

Hydrate Occurrence in Centrifugal Compressor Systems

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

Nuclear power plant systems, structures and components and their safety classification. 1 General 3. 2 Safety classes 3. 3 Classification criteria 3

Oil and Gas Pipeline Design, Maintenance and Repair

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT KEYWORDS. Seal welding, tube-to-tubesheet welds, heat exchanger, mock-up, tube expansion

Routine and Emergency Boiler Operation

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Thermal Control of the Extrusion Press Container

Why and How we Use Capacity Control

7.3 Fit selection. Inner ring: Rotating. Outer ring: Stationary. Inner ring: Stationary. Outer ring: Rotating. Inner ring: Stationary

Investigating the Impact of Boiler Aging In Replacement Decisions

North American Stainless

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

Miglioramenti nella flessibilità dei cicli combinati: esperienze recenti di Ansaldo Energia. Alice Pesenti Federico Calzolari

The soot and scale problems

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

OPERATING EXPERIENCE OF LARGE REHEAT HRSGs in MERCHANT SERVICE

USC Steam Turbine technology for maximum efficiency and operational flexibility. Dr. Rainer Quinkertz Andreas Ulma Edwin Gobrecht Michael Wechsung

UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0

EFFICIENT ENERGY SUPPLY (ELECTRICITY AND DISTRICT HEAT) FOR THE CITY OF LINZ

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

Power Plant Electrical Distribution Systems

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

Equipment Performance Monitoring

- Service Bulletin - Pistons.

Fleet Technician I Fleet Technician II Fleet Technician III

Combined Cycle Control Overview

Development of Tandem-Compound 1,000-MW Steam Turbine and Generator

RecipCOM. Expertise, reciprocating compressor monitoring and protection tailored to your needs

Stainless steel grade chart

Itemized RAI Responses

Power Plants. BENSON Once-Through Heat Recovery Steam Generator. Power Generation

EVERY PROOF. DURABILITY. HIGH-MILEAGE ISX TEARDOWN

HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V

How To Clean Up A Reactor Water Cleanup

North American Stainless

SWITCHING STRATEGIES: MOVING TO CONDITION- BASED MAINTENANCE. By David Stevens, Technical Manager & Trainer, AVT Reliability

HVAC Design Requirements

Engine, Drive Train, and Hydraulic Repair Indicator Quick Reference Guide

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

Stay Cable Replacement of the Luling Bridge

The Technology and Business of Power Andrew Valencia, P.E. Lower Colorado River Authority

Vogt Power Emission Control Solutions

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

Overview of Waste Heat Recovery for Power and Heat

Technical Data. 7. Bearing Fits. 7.1 Interference. 7.2 Calculation of interference F B LLLLLLLLL( A-54

Repair of damaged rotor journal portion

Plastic Injection Molding

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

Maintenance and Asset Management Strategy Using Physics of Failure Factors Analysis

Autoclave Design Considerations

SSE Seth Muthuraman PhD.

in-service inspections

10 Nuclear Power Reactors Figure 10.1

Facility Support Services

GEOTHERMAL POWER PLANTS IN JAPAN ADOPTING RECENT TECHNOLOGIES

Brochure. Generators for wind power Proven generators reliable power

System Solutions for Boiler Air Preheating

Transcription:

The Problem Solving of Exhaust Frame Air Cooling System Pressure Low in GE Frame 9 Gas Turbine Author: Nattapon Pinitchan, Kanyarat Tankong, EGAT (Bangpakong Power Plant), Thailand 1 of 10

ABSTRACT EGAT's Bangpakong Power Plant has The Combined Cycle with Gas turbine GE Frame 9 with 4 Units, produce 100 MW each. The exhaust frame air cooling system consists of parallel blowers of two units (Exhaust frame blower). The ambient air used in cooling is supplied for the turbine shell, the exhaust diffuser radial struts and third stage aft wheel space. The exhaust frame system control flow and pressure cooling air by the flexible seal clearance. The important flexible seal clearance it s between upper and lower half exhaust casing and between third aft wheel space. The effect for over clearance of flexible seal made exhaust casing distortion, high temperature on bearing No.3, high vibration, trouble alarm of Unit Auto Reducing Load by Exhaust Casing Cooling Pressure Low and shut down in a shutdown sequence. The maintenance & operation team monitored closely all systems and founded unusual exhaust frame air cooling pressure reduced. When unit reserved shutdown the exhaust frame system had inspected by visual. We founded that flexible seal damage such as material lost, melting and seal welding crack. Meanwhile we carefully considered to change flexible seal material to avoid thermal fatigue and welding residual stress for cyclic load operation, we was monitoring cooling air pressure rated and temporary repaired for availability of Power Plant. The preparation of spare part and scheduling provide for next interval inspection. For the cyclic load operation, all units must be monitored and corrected the data for the primary goal that can reduce power plant production costs. The improvement of inspection interval or inspection scope and spare part management should be considered for long life time operation, maintain function for availability and reliability electrical system in the country. 2 of 10

INTRODUCTION The Bangpakong Combined Cycle Power Plant, BPK-CC3 and BPK-CC4, has been in commercial operation since 1994. Each block is a multi-shaft combined cycle system that has two gas turbine generators and two heat recovery steam generator (HRSG), in which supply steam through a common header to a single steam turbine-generator. Gas turbines are heavy duty industrial gas turbine served by Gas turbine GE Frame 9. The performance of plants have reduced and founded mechanical degradation in many compartments. Due to the fact that the plants generated over twenty years, and the merit order is the method used in the electricity market in Thailand, the both reason effect to Bangpakong Combined Cycle Power Plant generate in the cyclic duty operation instead of the continuous duty operation in which was demanded to start/stop every weekend. Gas turbines wear in different ways for different service-duties. Thermal mechanical fatigue is the dominant limiter of life for peaking machines, while creep, oxidation, and corrosion are the dominant limiters of life for continuous duty machines. Interactions of these mechanisms are considered in the GE design criteria, but to a great extent are second-order effects. [1] For the starts-based maintenance criteria, operating factors associated with the cyclic effects produced during startup, operation and shutdown of the turbine must be considered. Operating conditions other than the standard startup and shutdown sequence can potentially reduce the cyclic life of the hot gas path components and rotors, and, if present, will require more frequent maintenance and parts refurbishment and/or replacement. [1] In term of effect by the cyclic duty operation in Bangpakong Power Plant, we found low pressure problem in exhaust frame cooling system which is significant by reason of it alarm trouble of Unit Auto Reducing Load by Exhaust Casing Cooling Pressure Low and cause shut down gas turbine in a shutdown sequence. 3 of 10

LOW PRESSURE PROBLEM IN EXHAUST FRAME COOLING SYSTEM The exhaust frame cooling system consists of parallel blowers of two units (88TK - 1, 88TK - 2). The ambient air used in cooling is supplied for the turbine shell, the exhaust frame radial struts and third stage aft wheel space, as shown in Figure 1. Air separately supply to cool the turbine shell and the exhaust frame radial struts for maintaining tight turbine-section clearance control and to prevent the cracking, distortion and deform in exhaust frame. The air flow pass the struts for cooling and maintaining uniform temperature of the struts. Then air going to third stage turbine aft wheelspace and remainder running to the load tunnel. Cooling for Turbine Shell 88TK - 1, 2 Cooling for 3 rd Aft Wheelspace Cooling for Exhaust radial struts Dumps into Load Tunnel Figure 1. Exhaust frame air cooling system Gas turbine As the concept of exhaust frame cooling system, low pressure was unquestionably a sign of air leakage from some of cracking and/or over clearances in case of completely inspection of blowers, motor and functions. The maintenance & operation team monitored closely all systems and founded unusual exhaust frame air cooling pressure reduced. Therefore the exhaust casing was inspected immediately for the period of reserved shutdown condition and we found over clearance between upper half and lower half inner exhaust diffuser, as shown 4 of 10

Power-Gen Asia 2014 in Figure 2. Air leakage test by running the exhaust cooling blower founded truly leakage stream through between clearances. The possible improvement response to the reliability and have no an impact on the plant availability is temporary repairing by using metal plate bar and welding both side along clearance. Figure 3 illustrate the way to temporary repair exhaust diffuser distortion. Nevertheless temporary repairing was done, the monitoring cooling air pressure rated still be running for certain reliability of power plant and prepare potentially scheduling of inspection and better enhancement in next interval. Figure 2. Clearance of upper-lower half inner exhaust diffuser Figure 3. Temporary exhaust frame repairing 5 of 10

SOLVING AND DISCUSSION According to possible failure discussion by thermal mechanical fatigue and high cyclic fatigue, which may be exhaust diffuser distortion, flexible seal damage and deteriorate on third stage buckets. Scheduling provide for additional failure in the next hot gas path inspection. Figure 4. Flexible seal cracked Figure 5. Damaged key of upper half outer exhaust casing For the duration of hot gas path inspection, there are several failures occur on exhaust diffuser part and construction. Figure 4 illustrate flexible seal crack which described reasonably damage by deforming of exhaust diffuser. The key of upper half outer exhaust casing damaged and dowel pin between upper lower half exhaust diffuser failed and 6 of 10

distorted as shown in Figure 5 and Figure 6 respectively. Some of dowel lost by distorted casing Figure 6. Damaged dowel and dowel hole Discussion, firstly, as air separately supply to cool the turbine shell and the exhaust frame radial struts for maintaining tight turbine-section clearance control and to prevent the cracking, distortion and deform in exhaust frame. The cyclic operation cause thermal mechanical fatigue and effect to exhaust frame distortion. Moreover the flexible seal misaligned to end with crack. Figure 7 described low pressure exhaust cooling system due to air leakage through flexible seal to exhaust stream. GE fundamental of gas turbine training manual describe Exhaust frame radial struts cross the exhaust gas stream. These struts position the inner cylinder and third bearing in relation to the outer casing of gas turbine. The struts must be maintained at a constant temperature to control the center position of rotor in relation to stator. Temperature stabilization is accomplished by protecting the struts from exhaust gases with a metal fairing that forms an air space around each struts. Turbine shell cooling air flows through the space between the struts and the wrapper to maintain uniform temperature of the struts. The low pressure cannot stabilize temperature around struts and exhaust frame construction, meaning the center position of rotor in relation to stator uncontrolled. Temperature gradient occur on struts, exhaust frame deformed, the upper-lower half separated as showing as clearance. Likewise loss of cooling and sealing at third stage aft wheelspace and small flow to the load tunnel which effect to high temperature on third bearing. Exhaust gas stream may slightly run to root section of third stage bucket cause of short life third stage bucket and all seal around. 7 of 10

Cooling for Turbine Shell 88TK - 1, 2 Loss Cooling for 3 rd Aft Wheelspace Cooling for Exhaust radial struts Exhaust stream leak Low flow to Load Tunnel Figure 7. Air leakage in exhaust frame air cooling system Figure 8. Distortion solving by inner exhaust frame repairing Secondly, problem solving, the effect of plant generate in the cyclic duty operation instead of the continuous duty operation in which was demanded to start/stop every weekend. The starts-based maintenance criteria were considered for preventing the thermal mechanical fatigue. The compartment was repaired, refurbished and considered new material for serving cyclic duty operation. The first question was Which material is suitable for high cyclic fatigue? the flexible seal material was changed from SUS 304 to SUS 310S which is more 8 of 10

composition of Ni and Cr. Inner cylinder liner was carefully replaced as shown in Figure 8 and additionally changed dowel pin and key of upper half outer exhaust casing. Figure 9. Distortion solving by adding dowel pin Figure 10. New flexible seal material SUS310S 9 of 10

CONCLUSION The cyclic duty operation of gas turbine develop crack and failure in various seals for instance sheet metal and/or plate and welding for construction, sealing and clearance, especially deteriorate mechanical hot gas path. Exhaust diffusers should be inspected clearance of upper-lower half inner exhaust diffuser, for cracking at every combustion, hot gas path and major outage. It not only exhaust diffuser but also parts in hot gas path section should be apprehensively monitored and corrected the data for the primary goal that can reduce power plant production costs. The improvement of inspection interval or inspection scope and spare part management should be reconsidered. Optimized planning and correct implementation for maintenance is necessity for reduced forced outages unscheduled repairs and downtime, long life time operation, maintain function for availability and increased starting reliability electrical system in the country. REFERENCES [1] Heavy-Duty Gas Turbine Operating and Maintenance Considerations, GER-3620L.1 (10/10) GE Energy, Atlanta, GA [2] Fundamentals of Gas Turbine Construction & Operation Training Manual, 1996, 10 of 10