Technical Data. General specifications Switching element function Rated operating distance s n 5 mm



Similar documents
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Inductive sensor NI10-M18-Y1X-H1141

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Series 8146/5-V37 and Series 8150/5-V37

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Solenoid Valve Island Type 3965

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

SEISMIC VELOCITY TRANSDUCER T1-40

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Control- and feedback head for integrated mounting on Robolux valves Type 2036

2.12. page Products for Explosion hazardous Environment

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Explosion proof enclosures

Terminal Box. Specifications TNCN

Compact pressure switch Flameproof enclosure Ex d Model PCA

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Relative pressure transmitter type 520

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

A good connection. International approvals.

Plug and Socket Devices SolConeX 16 A Series 8570

Safety instructions VEGADIS DIS81.CEIA/V****

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Inductive sensors. Compact, fast, reliable. Edition 2013

Plug and Socket Devices CES 63 A Series 8579

CAPACITIVE LEVEL METERS CLM 36

Control and Distribution Boxes made of Stainless Steel Series 8150

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

type V46, solenoid or pneumatic operated

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

TTF300 Field-mount temperature transmitter

Design of intrinsically safe systems

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Differential-Hall-Effect based Sensors Series A5S Overview

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Flow switches Series AD/VH

Series 3730 Type Electropneumatic Positioner

Instructions for Safe Use

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Terminal Boxes Series 8146

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Technical Information RIA14

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

EPHY-MESS GmbH phone: Berta-Cramer-Ring 1 fax: Wiesbaden info@ephy-mess.de Germany

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Worcester DS/DM Series UltraSwitch Switch box

Linear Luminaire with LED Series EXLUX 6402/2

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Cross-beam scanning system to detect slim objects. 100 mm in

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Cable Plug acc. to DIN EN , Form A

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

FGM 160 ATEX EC type examination certificate

Capacitive Prox E2K-X

Inductive proximity sensors IM 12 series, sensing range 2 / 4 mm DC 3-wire, metal housing

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Series 3730 Type Electropneumatic Positioner with FOUNDATION fieldbus communication

Flameproof Audible Signal 115 db (A) Series YA90

Technical data sheet TDS0070

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

distributing & controlling system solutions

Plastic tube flowmeters Series PT/PS

INTERNATIONAL STANDARD

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing


Magnetic proximity switches

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Plug-in relays Mini ISO relays

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

MINI MCR-SL-R-UI(-SP)

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

3/2-way Solenoid Valve, direct-acting, NC or NO

Threaded Resistance Thermometers Model TR10-D, Miniature Design

PTB 07 ATEX Example/Beispiel/Exemple. Flipperventil Operating Instructions

Redundancy Module QUINT-DIODE/40

Transcription:

0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush Output polarity NAMUR Assured operating distance s a 0... 4.05 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage U o 8.2 V (R i approx. 1 kω) Switching frequency f 0... 3000 Hz Hysteresis H typ. 5 % Suitable for 2:1 technology yes, Reverse polarity protection diode not required Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Functional safety related parameters MTTF d 11774 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25... 100 C (-13... 212 F) Mechanical specifications Connection type cable PVC, 2 m Core cross-section 0.34 mm 2 Housing material Stainless steel 1.4305 / AISI 303 Sensing face PVDF Degree of protection IP68 Cable Bending radius > 10 x cable diameter information Use in the hazardous area see instruction manuals Category 2G; 3G; 1D; 3D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates UL approval culus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions M14x1 Ø 11 31 14 3 19 Electrical Connection BN BU L+ L- 1

Equipment protection level Gb Device category 2G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate PTB 00 ATEX 2048 X CE marking 0102 II 2G Ex ia IIC T6 T1 Gb The Ex-related marking can also be printed on the enclosed label. Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Appropriate type NJ 5-11-N... Effective internal inductivity C i 45 nf ; a cable length of 10 m is considered. Effective internal inductance L i 50 µh ; a cable length of 10 m is considered. Maximum permissible ambient temperature T amb and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. The connecting parts of the sensor must be set up in such a way that degree of protection IP20, in accordance with lec 60529, is achieved as a minimum. When using the device in a temperature range of -60 C to -20 C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. s must be avoided on the mechanical housing components. 2

Equipment protection level Gc (nl) Note This instruction is only valid for products according to EN 60079-15:2005, valid until 01-May-2013 Device category 3G (nl) for use in hazardous areas with gas, vapour and mist CE marking 0102 Standard conformity Effective internal capacitance C i Effective internal inductance L i for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Protection from UV light Protection of the connection cable Connection parts II 3G Ex nl IIC T6 X EN 60079-15:2005 Ignition protection category "n" 45 nf ; a cable length of 10 m is considered. 50 µh ; a cable length of 10 m is considered. and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! must be observed. The sensor must only be operated with an energy-limited circuit, which satisfies the requirements of IEC 60079-15. The explosion group complies with the connected, supplying, power limiting circuit. The sensor must not be exposed to ANY FORM of mechanical danger. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. The connection cable must be prevented from being subjected to tension and torsional loading. s must be avoided on the mechanical housing components. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 3

Equipment protection level Gc (ic) Device category 3G (ic) Certificate of Compliance CE marking for use in hazardous areas with gas, vapour and mist PF 13 CERT 2895 X II 3G Ex ic IIC T6 T1 Gc The Ex-significant identification is on the enclosed adhesive label Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category "ic" Effective internal inductivity C i 45 nf ; a cable length of 10 m is considered. Effective internal inductance L i 50 µh ; A cable length of 10 m is considered. for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Connection parts and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group complies with the connected, supplying, power limiting circuit. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. s must be avoided on the mechanical housing components. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 4

Equipment protection level Da Device category 1D for use in hazardous areas with combustible dust EC-Type Examination Certificate PTB 00 ATEX 2048 X CE marking 0102 II 1D Ex ia IIIC T135 C Da The Ex-related marking can also be printed on the enclosed label. Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Appropriate type NJ 5-11-N... Effective internal inductivity C i 45 nf ; a cable length of 10 m is considered. Effective internal inductance L i 50 µh ; a cable length of 10 m is considered. Maximum permissible ambient temperature T amb and in this instruction manual. The EC-Type Examination Certificate has to be observed. Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. The connecting parts of the sensor must be set up in such a way that degree of protection IP20, in accordance with lec 60529, is achieved as a minimum. When using the device in a temperature range of -60 C to -20 C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. s must be avoided on the mechanical housing components. Do not attach the nameplate provided in areas where electrostatic charge can build up. 5

Equipment protection level Dc (td) Note This instruction is only valid for products according to EN 61241-0:2006 and EN 61241-1:2004 Note the ex-marking on the sensor or on the enclosed adhesive label Device category 3D CE marking for use in hazardous areas with non-conducting combustible dust II 3D Ex td A22 IP67 T80 C X Standards EN 61241-0:2006, EN 61241-1:2004 Protection via housing "td" and in this instruction manual. The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! must be observed. Minimum series resistance R V A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum permissible ambient temperature T Umax tance Rv. Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resis- at U Bmax =9 V, R V =562 Ω 57 C (134.6 F) using an amplifier in accordance with 57 C (134.6 F) EN 60947-5-6 The sensor must not be exposed to ANY FORM of mechanical danger. Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. Protection of the connection cable The connection cable must be prevented from being subjected to tension and torsional loading. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be 6