RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer



Similar documents
RS DIGITAL THERMOMETER

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

USER GUIDE. LED Light Meter. Model LT45

Temperature Humidity Meter

1. SAFETY INFORMATION

Professional Thermohygrometer

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

SOUND LEVEL METER 94405

Integrating Sound Level Meter and Datalogger

Hygro-Thermometer + InfraRed Thermometer Model RH101

AutoRanging Digital MultiMeter

4-Channel Thermometer / Datalogger

Owner s Manual

Dual Laser InfraRed (IR) Thermometer

Multi Media Cable Tester TM-901N/TM-902/TM-903

User's Guide. Pinless Moisture Meter. Model MO257

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Ground Resistance Clamp On Tester

Manual Ranging MultiMeter

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

User Guide. Model Insulation Tester / Megohmmeter

BLOOD COLLECTION MIXER

HVAC Clamp Meter. Users Manual

Instruction Manual Temp 4/5/6 Temperature Meter Series

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Pocket Tach 99 (PT99) Non-Contact Tachometer

Mini InfraRed Thermometer with Laser Pointer

62 Max/62 Max + Infrared Thermometer

UT202A Operating Manual. Contents

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

User's Guide. True RMS Industrial Multimeter

Microwave Meter. Instruction Manual

Duct Humidity Transmitter

INSTRUCTION MANUAL DTH Fax: (503)

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

HOBO U14 Data Logger User Manual

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

User Guide. Temperature and Humidity Datalogger. Model 42280

ExStik TM ph Waterproof Meters

User's Guide Integrating Sound Level Datalogger Model

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

User Guide. 4 wire Earth Resistance Tester Model GRT300

Ground Resistance Clamp-On Tester

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

Important Safeguards

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Multifunction HVAC and IAQ Meter

DISSOLVED OXYGEN METER Model : DO-5509

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Model UT33A: OPERATING MANUAL Table of Contents (1)

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

How To Use A Meter

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Thermistor Thermometer MODEL NO

Dual Laser InfraRed (IR) Thermometer with Color Alert

High Temperature InfraRed Thermometer with Laser Pointer

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Phoenix Body Fat Scale Manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

BASIC BODY COMPOSITION SCALE

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Instruction Manual. T3111 T3111L T3111P T3111Ex

Laser Distance Meter Laser-Distanzmesser Laser distance-mètre Metro di distanza laser Medidor Láser de Distancia User Manual

Stove Guard Kit User Manual

User's Guide. Digital Sound Level Meter. Model

Drayton Digistat +2RF/+3RF

CONTENTS USING THE LIGHTS KEY...31 NETWORK ALARMS...32 FAULT AND ERROR MESSAGES...33

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

3. Enter the first five digits of desired frequency ( for MHz).

Model UT201/202: OPERATING MANUAL. Table of Contents

Portable Air Conditioner

Nokia Bluetooth Headset BH-607. Issue 2. 1

BODY FAT & HYDRATION % MONITOR SCALE

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

OCS-S High Resolution Digital Crane Scale

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Operating instructions Platform/floor scales

IN-OUT Thermometer with Cable Free Sensor and Clock

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

USER MANUAL V5.0 ST100

Digital Photo Picture Frame. Operation Manual

Standard Operating Procedure

Tympanic Thermometer

Dual Laser InfraRed (IR) Thermometer

Thermal environments. Tel

EK908FHL - Thermostat for floor heating

NFC Communication Tray Model: HHX-IT3-Z

PREMIUM CLEAN ROOM MONITOR MODELS 8630-CRM-S 8630-CRM-P

Dual Laser InfraRed (IR) Thermometer

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Estação Meteorológica sem fio VEC-STA-003

EzFlex Combustible Gas Leak Detector Model EZ40

TENSIONMETER ** code 183_LNRSTW **

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Transcription:

RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES

CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4 4-1 Description of Parts & Control keys...4 4-2 Description of Display...6 5. MEASURING PROCEDURE...8 5-1 Getting Started...8 5-2 Settings and Calibrations...8 5-3 Air Velocity Measurement...10 5-4 Air Flow Measurement...10 5-5 MAX/MIN/AVG Recording Measurement...11 5-6 Air Velocity Manual Data Memory and Read Mode...11 5-7 Air Flow Manual Data Memory and Read Mode...11 5-8 Air Flow Auto Data Memory and Read Mode...12 5-9 Clearing Memory...12 6. MAINTENANCE...13 6-1 Cleaning...13 6-2 Battery Replacement...13 04/26/13 Version No. 01

SAFETY INFORMATION / EN 1. SAFETY INFORMATION The following symbol may appear on the instrument and in this instruction manual: Refer to Instruction Manual CAUTION When using the meter to check air flow, make certain that you can safely raise and hold the meter while making measurements. Be especially careful when working on a ladder. Observe all necessary precautions so that the unit does not become caught in moving machinery or touch any exposed electrical wiring. DANGER The meter is not designed for use in gas mixtures other than air. DO NOT use the unit with corrosive or other dangerous or explosive gas mixtures. 04/26/13 Version No. 01 EN-1

INTRODUCTION / EN 2. INTRODUCTION The Portable Air Velocity Meter is a lightweight instrument that can be used anywhere to measure air velocity using the flexible telescoping probe, applications include ventilation hood air velocity, clean rooms, OSHA compliance, ventilation ducts and outlets, heating and air conditioning, wind tunnels, product development, air flow research and mass flow measurement in ducts. Applications: HVAC system performance Commissioning Plant maintenance Critical environment certification Duct traverses FEATURES: Fast response probe. Air flow volume. Instant / Avg / 3 2 V max flow measurement. Velocity m/s, f t/min, knots, km/hr, mph, Beaufort (Bft). Data hold & Maximum / Minimum / Average function. Manual data memory and read function (5 x 99 sets). Auto data memory and read function (5x 99 sets). LCD triple display. Auto power off function ON / OFF Time setting. Backlight function ON / OFF Time setting. Telescoping probe with flexible probe end. Simple and safe to use. EN-2 04/26/13 Version No. 01

SPECIFICATIONS / EN 3. SPECIFICATIONS Display : Triple display, 4 digit LCD reading. Velocity Probe : Range : 0 to 30 m/s (0 to 600 ft/min) Resolution : 0.01 m/s (1 ft/min) Accuracy : ±3% of reading ±1%FS Duct Size : Range : 1 to 635 cm in increments of 0.1 cm. (1 to 250 inches in increments of 0.1 in.) Volumetric Flow Rate : Ranges : Actual range is a function of actual velocity, and duct size. Warm up Time : < 1 minute Response Time : < 2 seconds Sampling Rate : One time per second. Manual Data Memory Capacity : 5 x 99 sets. Auto Data Memory Capacity : 5 x 99 sets. Operation Temperature Range : Meter : 0 to 50 C (32 to 122 F) Probe : -10 to 60 C (14 to 140 F) Storage : -20 to 60 C (-4 to 140 F) Operation Conditions :Altitude up to 2000 metres. Relative humidity up to 80%RH, non condensing. Power Supply : 6 pcs 1.5V size AAA battery. Battery Life : Approx. 10 hours. Probe Dimensions / Weight : Wire length : 2.2 metre (7.2 ft) Probe length : 1.2 metre (3.9 ft) Probe diameter of tip : 9.0 mm (0.35 in.) Probe diameter of base : 28.0 mm (1.1 in.) Probe weight : 165 g (0.36 lbs) Meter Weight / Dimensions : 235 g (0.52 lbs) 150 x 72 x 35 mm 5.9 x 2.8 x 1.4 inches Supplied Accessories : Instruction manual, battery and Carry case. 04/26/13 Version No. 01 EN-3

PARTS & CONTROLS / EN 4. PARTS & CONTROLS 4-1 Description of Parts & Control keys 16 1 1 3 5 4 7 11 10 13 6 8 9 12 14 15 14 2 1. Air velocity sensor. (Measurement direction) 2. Flexible, telescoping probe. 3. Display. 4. Power key : Press power key to turn the meter on or off. 5. H HOLD key : Press H Hold key to freeze or unfreeze the display reading. In H mode, press UNIT key to select the desired unit of display. 6. key : Press key to turn on and off the backlight. 7. MX/MN key : Press MX/MN key to select between the reading of Maximum, Minimum, Average and Current record mode. Press MX/MN key for 2 seconds to exit this mode. 8. SET key : Press SET key to enter setting mode. Flow setup mode. EN-4 04/26/13 Version No. 01

PARTS & CONTROLS / EN Choosing a time constant mode. Choosing auto data memory interval time mode. Auto power off time setting mode. Backlight time setting mode. Air velocity calibration mode. Reset to factory default calibration value mode. 9. UNIT key : Press UNIT key to select the desired unit of measure. 10. FLOW key : Press FLOW key to select desired air velocity to determine the Air Flow. 2/3V MAX : Use the maximum reading obtained to determine the 2/3V MAX Air Flow. AVG : Use the average reading to determine the Air Flow. Use the current reading to determine the Air Flow. 11. key : Enter / Exit a setting mode or store the displayed setting. 12. Test ID key : A group of samples. The statistics (maximum, minimum, average and count) are calculated for each TEST ID. The total number of TEST IDs is 10. Press Test ID key to select the desired TEST ID number from 0 to 9. 13. AUTO MEM key : 1 In the setting mode, press this key to move the flashing cursor to the left. 2 In the TEST ID modes 0 to 4, press this key once to store the one data to memory. 3 In the TEST ID modes 5 to 9, press this key to start auto data memory mode, press this key again to exit this mode. 14. keys : 1 In the setting mode, press keys to increase or decrease the displayed setting. 2 In the READ mode, press keys to select increase or decrease the memory address. 15. READ key : 1 In the setting mode, press this key to move the flashing cursor to the right. 2 Press this key to enter the data memory READ mode, press this key again to exit this mode. 16. Sensor protection cap. 04/26/13 Version No. 01 EN-5

PARTS & CONTROLS / EN 4-2 Description of Display AIR VELOCITY DISPLAY FLOW SET UP DISPLAY AIR FLOW DISPLAY AIR VELOCITY DISPLAY : MEMORY DISPLAY : Auto power off indication. H : Data hold indication. SET : Setting mode indication. REC : Record mode and current air velocity measured display indication. REC MAX : Maximum air velocity measured display indication. REC MIN : Minimum air velocity measured display indication. REC AVG : Average air velocity measured display indication. (The average of the last 30 samples) Air Velocity Units : knots mile/hr : Miles per hour km/hr : Kilometres per hour ft/min : Feet per minute Bft : Beaufort scale m/s : Metres per second FLOW SET UP DISPLAY : : Round Duct diameter dimension indication. X : Rectangle Duct X dimension indication. Y : Rectangle Duct Y dimension indication. Kf : K factor indication. AREA : Duct Area indication. m 2 : Square metres ft 2 : Square feet in : Inches cm : Centimetre EN-6 04/26/13 Version No. 01

PARTS & CONTROLS / EN AIR FLOW DISPLAY : 2/3V MAX : 2/3V Maximum mode is selected indication. AVG : Average mode is selected indication. : Current mode is selected indication. x 10 : Multiply reading by ten. x 100 : Multiply reading by one hundred. x 1000 : Multiply reading by one thousand. ft 3 /min : Cubic feet per minute. m 3 /min : Cubic metres per minute. MEMORY DISPLAY : TEST ID 0 4 : Manu data memory indication. TEST ID 5 9 : Auto data memory indication. SAMPLE : Data memory number address indication. AVG SAMPLE : Total average data number indication. M : Data memory indication, M display one time store one data into the memory. R : Data read mode indication. TC INTV s : Average time constant indication. m s : Auto data memory interval time indication. + - : Low battery indication. 04/26/13 Version No. 01 EN-7

MEASURING PROCEDURE / EN 5. MEASURING PROCEDURE 5-1 Getting Started 1. Installing the Batteries Insert six AAA batteries as indicated by the diagram located on the inside of the battery compartment. 2. Extending the Probe To extend the probe, remove the sensor protection cap, hold the handle in one hand while pulling on the probe tip with the other hand. Do not hold the cable while extending the probe as this prevents the probe from extending. 3. Using the flexible telescoping probe The flexible telescoping probe contains the air velocity sensor. When using the probe, remove the sensor protection cap then rotate or bend the flexible tube, make sure the sensor window is fully exposed and is facing upstream. If in the right direction, the user will see the red-ink marking as following figure. 4. Retracting the Probe To retract the probe, hold the handle in one hand while pushing on the probe tip with the other hand. If you feel the probe antenna binding, pull gently on the probe tube until the flexible tube section is retracted. Collapse the rest of the antenna by pressing the probe tip and refit the sensor protection cap. 5-2 Settings and Calibrations 1. Flow Set Up mode 1 Press key to turn on the meter. 2 Press UNIT key to select the desired measurement unit. 3 Press SET key to enter the Flow Setup mode, the SET symbol is displayed. There are 4 types : Round Duct ( ), Rectangle Duct ( ), Duct Area (AREA), and K factor (Kf). 4 Press and keys to scroll through the choices and press key to confirm your choice. EN-8 04/26/13 Version No. 01

MEASURING PROCEDURE / EN If round duct is chosen, the symbol will displayed. Use and keys to set the size (diameter) from 1.0 to 635.0 cm or 1.0 to 250.0 inches. Press key to store the value. If rectangle duct is chosen, the X symbol will displayed. Use and keys to set the X size of the duct, then press key to store the value and advance to the next dimension, the Y symbol will displayed. Use and keys to set the Y size of the duct, then press key to store the value. If duct area is chosen, the AREA symbol will displayed. Use and keys to set the value and decimal point of the duct area from 0.001 to 9999ft 2 or 929m 2, then press key to store the value. If K factor is chosen, the Kf symbol will displayed. Use and keys to set the value and decimal point of the K factor from 0.001 to 9999, then press key to store the value. Note : Kf is the number by which the meter multiplies the velocity measurement to display volume. 5 Press SET key several times until the SET symbol disappears to exit the setting mode. 2. Choosing a Time Constant mode 1 Press SET key twice to enter this mode, the TC symbol and the current time constant are displayed. 2 Press and keys to scroll through the choices and press key to store the choice. The choice for the time constant are : 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25 and 30 seconds. 3 Press the SET key until the SET symbol vanishes to exit the setting mode. The time constant is an averaging period. It is used to dampen the display. If you are experiencing fluctuating flows, a longer time constant will slow down those fluctuations. The average method is also referred to as a moving average. 3. Choosing a Auto Data Memory Interval Time mode 1 Press SET key three times to enter this mode, the INTV symbol and the current interval time are displayed. 2 Press and keys to scroll through the log interval choices. The choice are : 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25 and 30, seconds, and 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25, 30 and 60, minutes. Press key to store the choice. 3 Press the SET key until the SET symbol vanishes to exit the setting mode. 4 Auto Power Off Time Setting mode 1 Press SET key four times to enter this mode, the APO symbol and the current auto power off time are displayed. 04/26/13 Version No. 01 EN-9

MEASURING PROCEDURE / EN 2 Press and keys to set the desired auto power off time from 1 to 50 minutes or to set to m to disable this function. Press key to store the setting. 3 Press the SET key until the SET symbol vanishes to exit the setting mode. 5. Backlighting Time Setting mode 1 Press SET key five times to enter this mode, the bl symbol and the current backlight time are displayed. 2 Press and keys to set the desired backlight time from 1 to 50 seconds or to set to s to disable this function. Press key to store the setting. 3 Press the SET key until the SET symbol disappears to exit the setting mode. 6. Air Velocity Calibration mode 1 Press SET key six times to enter this mode, the USEr CAL no symbol is displayed. 2 Press or keys to select symbol is displayed. 3 Press key to enter the air velocity zero calibration mode, the CAL 0 symbol is displayed. 4 Refit the sensor protection cap, until the air velocity reading is stable then press key to store the zero air velocity reading, and enter the air velocity scale factor calibration mode, the scale factor value is displayed. 5 Insert the meter probe into the calibration tunnel with the sensor window toward the air flow. Secure the probe firmly with the velocity sensor placed where air speed is known. 6 Press,, and keys to set the scale factor value until the display reading reaches the desired value, then press key to store the scale factor value, the CAL PASS symbol will display one second. 7 Press the SET key until the SET symbol vanishes to exit the setting mode. 7. Reset to Factory Default Calibration value mode 1 Press SET key seven times to enter this mode, the def CAL symbol is displayed. 2 Press or key to select or, select then press key to reset the unit to factory default calibration value and exit the setting mode. 5-3 Air Velocity Measurement 1. Press key to turn on the meter. 2. The display will show the air velocity reading directly on the Air Velocity Display. 3. Press UNIT key to select the desired measurement unit. 4. Press H HOLD key to freeze or unfreeze the display readings. In HOLD mode, the H symbol is displayed press UNIT key to select another display unit reading. 5-4 Air Flow Measurement AIR FLOW = (AIR VELOCITY) x (AREA) EN-10 04/26/13 Version No. 01

MEASURING PROCEDURE / EN 1. Press key to turn on the meter. 2. The display will show the air velocity reading directly on the air velocity display. 3. The flow type setting is displayed on the flow set up display. 4. Press FLOW key to select the desired 2/3V MAX mode, AVG mode or current mode. If 2/3V MAX mode is chosen, the 2/3V MAX symbol will be displayed. The meter will use the maximum air velocity value obtained to determine the 2/3V MAX Air Flow. If average mode is chosen, the AVG symbol will be displayed. The meter use air velocity average value (the last 30 samples) obtained to determine the Average Air Flow. If current mode is chosen, no symbol will be displayed. The meter will use the current air velocity value obtained to determine the Current Air Flow. 5. The display will show the air flow reading directly on the Air Flow Display. 5-5 MAX/MIN/AVG Recording Measurement 1. Press MX/MN key to enter the recording mode, the REC symbol is displayed and the auto power off function will automatically be cancelled. 2. Pressing MX/MN key to scroll the display through the maximum ( REC MAX ), minimum ( REC MIN), average ( REC AVG ) and current ( REC ) air velocity readings. 3. Press H HOLD key to pause recording, the H symbol is displayed, press H HOLD key again to resume recording. 4. Press MX/MN key for 2 seconds to exit this mode. 5-6 Air Velocity Manual Data Memory and Read Mode TEST ID 0 Memory Mode : 1. Press Test ID key to select the TEST ID 0 memory. 2. Press the AUTO MEM key, to store one set of readings into the memory and increments the sample display by 1, up to the max total memory size of 99 sets, the M symbol will also be shown each time to confirm the storage. 3. Press READ key to enter READ mode, the display will show R symbol and the memory address number. Press or key to select the desired memory address number data for display. Press READ key again to exit the READ mode. 5-7 Air Flow Manual Data Memory and Read Mode Memory Mode, TEST ID 1 ~ 4 only. 1. Press Test ID key to select the manual memory mode location. TEST ID 1 ~ 4. 2. Press AUTO MEM key to store one set of readings into memory and increment the TEST ID sample display by 1, the M symbol will also be shown each time to confirm the storage. The maximum total memory size is 99 Manual sets. If the flow parameters are change when in the read mode, the TEST ID will automatically increment. 04/26/13 Version No. 01 EN-11

MEASURING PROCEDURE / EN 3. Press READ key to enter READ mode, the display will show R symbol and the memory address number. Press or key to select the desired memory address number data for display. 4. Press MX/MN key to scroll through each of the memory readings for the maximum (MAX) air velocity and air flow and the memory address number, the minimum (MIN) air velocity and air flow reading and the memory address number, and the average (AVG) air velocity and air flow reading and the total average samples. Press the Test ID to select each range in turn. 5. Press READ key again to exit the READ mode. 5-8 Air Flow Auto Data Memory and Read Mode TEST ID 5 ~ 9 Memory Mode 1. Press Test ID key to select the TEST ID 5 memory. 2. Press AUTO MEM key to start auto data memory mode, INTV symbol and current interval time are display, the M symbol flashes one time to indicate that one set of data has been memorized. Total memory size is 99 sets per each IDs. Press AUTO MEM key again to exit this mode. If the flow parameters are change when in the read mode, the TEST ID will automatically increment. 3. Press READ key to enter READ mode, the display will show R symbol and the memory address number. Press or key to select the desired memory address number data for display. 4. Press MX/MN key to scroll through the memory of the maximum (MAX) air velocity and air flow reading and the memory address number; the minimum (MIN) air velocity and air flow reading and the memory address number; and the average (AVG) air velocity and air flow reading and the total average samples. Press the Test ID to select each range in turn. 5. Press READ key again to exit the READ mode. 5-9 Clearing Memory 1. Press key to turn off the meter. 2. Press and hold down the AUTO MEM key then press key to turn on the meter to enter clear memory mode, CLr no symbol is displayed. 3. Press Test ID key to select the desired TEST ID to be clear. 4. Press key to select the symbol. 5. Press AUTO MEM key to clear the memorized data. repeat steps 2 to 5 if required. 6. Press key to exit the clear memory mode. EN-12 04/26/13 Version No. 01

MAINTENANCE / EN 6. MAINTENANCE 6-1 Cleaning : Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Clean and dry as required. 6-2 Battery Replacement : Note: The condition of the battery should be checked prior to use and changed if necessary. The LCD display will show + - symbol when the battery power is not sufficient for accurate testing. 1. Remove discharged battery and insert new one, respecting the correct polarity. 2. Dispose of the removed batteries is accordance with local regulations. 3. If the instrument is likely to remain unused for a long period it is advised to remove the batteries. 04/26/13 Version No. 01 EN-13