Cl/SfB (13.9) a comprehensive. technical guide. to the specification of. vapour control layers. www.proctorgroup.com GROUP LTD



Similar documents
BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Multi-layer Insulation Blanket for Roofs

Including. Rubershield-Pro. Breather Membrane

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Monarflex Vapour Control Layers

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

AND MEMBRANES ROOFING UNDERLAYS.

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Condensation. Some Causes, Some Advice

SANS FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/ / / /341

Asphalt Shingle Application Requirements

Preventing Ice Dams on Roofs

Chapter 2 Basis of design and materials

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

BLACK JACK ALL WEATHER ROOF COATING

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Bituminous Sheet Flat Roofs: Their repair and maintenance

Dealing with damp, condensation and mould growth in your home.

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

Housing Fact Sheets. Moisture Condensation at the Windows

Dealing with damp and mould growth

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Housing Services Guidance for tackling condensation, damp and mould in your home

Wraptite THE AIRTIGHT AND VAPOUR PERMEABLE MEMBRANE

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

MONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED)

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

DENSO WATERPROOFING SYSTEMS

Roofers Guide to Underslating Membranes

Energy Company Obligation (ECO): Technical Monitoring Questions

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

CONDENSATION - THE BASICS

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

CONDENSATION IN REFRIDGERATED BUILDINGS

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Ubiflex. Non-lead flashing system

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

The formation of roof waterproofing details calls for

SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES

PROFILED METAL ROOFING DESIGN GUIDE

Manual lifting and handling

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Glidevale offers a complete range

Technology at its best. Benefits

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Rooflighting and Glazing

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

ROOFS, SNOW AND ICE DAMS

PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs.

Rockwool Cladding Roll

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Mission 7: Saving Energy

Renovating Your Basement

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

LAYING BLOCK AND BRICK

Humidity, Condensation, Clouds, and Fog. Water in the Atmosphere

EcoTouch Insulation with PureFiber Technology

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

WATERPROOFING FOR CONCRETE STRUCTURES

INSULATED PITCHED ROOFING

Rockwool Flexi Insulation Application Guide

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

ICOPAL POUR AND ROLL ROOF WATERPROOFING ICOPAL POWER ELASTOMERIC ROOF WATERPROOFING SYSTEM

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

THE REDLAND GUIDE TO BS 5534

Your guide to home maintenance. Flat Roofs

Code of practice for control of condensation in buildings

Molds and mildew are fungi that grow

ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE

Retrofitting an Insulated Cold Roof

Water Damage & Repair

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

SHINGLE APPLICATION GUIDE

I n s u l a t i o n. Low Energy Low Carbon Buildings

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

Sealing & Bonding Sika solutions for Window Installation

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors

How to repair your existing low slope flat roof.

Transcription:

Cl/SfB (13.9) Ln6 a comprehensive technical guide to the specification of vapour control layers..the knowledge to produce solutions GROUP LTD www.proctorgroup.com

Partnerships in action THE PROBLEM GROUP LTD Moisture in today s buildings can be a continuous problem if not tackled professionally. Equally, new and existing buildings, particularly those that will house hi-tech machinery and computer equipment, need to be guarded against condensation and its consequences. Homes fitted with double glazing no longer have natural outlets for moisture; while industry demands a higher level of comfort for its workers. The loft conversion market, too, seeks faster, more effective production methods that will bring confidence in guarantees. THE SOLUTION (below) A. Proctor Group s Head Office- The Haugh, Blairgowrie, Perthshire. The A.Proctor Group, with its history of successful technical solutions, recognised these problems and has linked with two manufacturers to offer total solutions to all the traditional problems of vapour control. All the manufacturers use state of the art plant and production equipment, and operate within recognised quality standards. These total solution products offer the most comprehensive range available. Each one is fully researched and tested to ensure complete satisfaction and guaranteed performance. THE KNOWLEDGE The A.Proctor Group has, for over 40 years, been serving the construction industry with an extensive portfolio of technically advanced thermal, acoustic and membrane products. This commitment to develop a complete membrane range, covering Vapour Control Layers and Breather Membranes in pitched roofing and industrial cladding, has resulted in a unique, exclusive partnership with two of the U.K s largest and most respected membrane manufacturers. BSk, based in Strood, Kent, manufacture the U.K s only reinforced polyethylene and polyethylene /foil Vapour Control Layers to a carefully determined specification. ISO 9000 quality procedures ensure product reliability and performance. Don and Low Nonwovens have now added Roofshield, for domestic pitched roofing, to Cladshield and Frameshield, the U.K s top brands in the industrial cladding and timber frame markets. A nationwide technical specification team, together with Tecline Advice Centre, ensure professional response to the industry s requirements. A national network of distribution outlets ensure prompt and effective service. two

Contents The Importance of Vapour Control page 4-9 Product Selector Membrane Information Sheets Details and Installation Preferred Details page 10 page 11-12 page 13-14 page 15 OBJECTIVE OF TECHNICAL GUIDE This Technical Guide offers good advice on the specification and installation of membranes to control water vapour within roof and wall constructions. By adopting the practical measures given in this Technical Guide, the design and build team can reduce the risks of condensation, water ingress and excessive heat loss after the building has been completed. three

The Importance of Vapour Control INTRODUCTION Industrial Processes GROUP LTD It has been long recognised that condensation within buildings can be a problem. But how can it be minimised? The starting point is to look at the sources of moisture within a building. SOURCES OF MOISTURE WITHIN A BUILDING Domestic Functions Cooking, washing and drying clothes, dish washing, bathing and showering are all everyday activities that result in the internal air coming into contact with water and turning to steam or vapour. People Many industrial processes will involve vapour generation for example textile and paper mills, laundries, printing houses. Indoor heated swimming pools and leisure pools will also create moisture which requires control. Construction Wet finishes such as concrete slabs, screeds, masonry and plaster are installed with a lot of water within them. For example, a 150mm thick concrete slab would have approximately 27 litres within each square metre when first cast and drying out takes many months, often long after the roofing and walling have enclosed the slab. (below) British American Tobacco, Southampton. Our bodies perspire, especially when we are exercising. It has been estimated that a person typically generates 1.2 litres of moisture per day. This becomes much more of an issue when large groups of people are gathered together, such as in a school, a theatre or a sports hall. WATER VAPOUR PRESSURE Internal conditions within a building are measured in terms of: air temperature in o C relative humidity in % Using the psychometric chart the vapour pressure in kilopascal can be read off. The greater the vapour pressure within the building, the greater the condensation risk. The notional indoor conditions for a range of building types are given in the table and are plotted on the chart. Higher humidities are generated in kitchens, bathrooms and laundries. With the information about what is likely to be going on in the building, the designer is in a position to take the design forward. four

The Importance of Vapour Control CONDENSATION The air around us holds moisture in the form of a colourless vapour; the warmer the air, the greater the amount of moisture it can hold. If the air is cooled, then it cannot hold as much moisture and there comes a point at which the water changes from a vapour to a liquid, which we see in the form of condensate. At this point the relative humidity is 100%. As an example, we can see this when we take a cold bottle of wine out of the fridge. The air containing water vapour is cooled as it passes over the glass bottle, such that the air can no longer hold the water vapour and a film of water droplets forms as condensate on the bottle. Another everyday example of condensation is on a mirror in a bathroom. As we have a bath or shower, vapour is released into the air, thus the humidity levels increase. As the vapour laden air passes the mirror the temperature drops and the vapour is released on the mirror in the form of water. Condensation occurs within roof and wall constructions if the heated internal air escapes through the lining and insulation then comes into contact with the cold outer surfaces, forming condensation which can drip back down into the building. Alternatively with a metal roof on a cold clear night the surface temperature of the metal sheets may be significantly less than the surrounding ambient temperature. Significant quantities of ice and/or condensation may form on the underside of the weather sheet. Such effects are caused by night radiation and wind chill. Relative Humidity % Saturation 90 70 50 30 10 80 60 40 20 0-5 0 5 10 15 20 25 Type of building Dry Bulb Air Relative Vapour Temperature oc Humidity % Pressure kpa A Factories and heated warehouses 15 35 0.6 B Offices 20 40 0.9 C Schools 20 50 1.2 D Houses and flats 20 55 1.3 E Textile factories 20 70 1.6 F Swimming pool halls 25 70 2.2 Table 1 - Notional internal conditions, taken from BS6229 The threshold between the high/moderate internal vapour pressure is taken as 20 C 60%RH (=1.4KPa). The threshold between the moderate/low internal vapour pressure is taken as half of the upper threshold (=0.7KPa). HIGH MODERATE LOW Wet bulb temperature C Dry bulb temperature C Moisture content g/kg dry air 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Vapour pressure KPa 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 3.1 2.9 2.7 2.5 2.3 2.1 1.9 1.7 1.5 1.3 1.1 0.9 0.7 0.5 0.3 0.1 five

The Importance of Vapour Control GROUP LTD AFFECTS ON BUILDING FABRIC Condensation within roof and wall constructions can lead to serious problems: Timber can rot, causing severe structural weakening reducing life of structure. Wetting can cause timber and other hygroscopic materials to swell, resulting in distortion and permanent damage to sarking boards and wall plates. With the continuing trend to increase the thickness of thermal insulation, the risk of unwanted condensation forming will be ever present and hence the need for care in dealing with vapour control in buildings. Solving condensation problems after a building is completed is not straightforward, and sometimes requires the total dismantling of the roof or wall, which is a costly repair. 1 Warm Vapour laden air 2 Dispersed Vapour 3 Decking 4 Vapour Barrier 5 Insulation 6 Breather Membrane 7 Vapour Condensate builds up on underside of roof, water droplets fall onto waterproof breather membrane and run off into gutter. 8 Outer Covering 9 Cold Air Corrosion may occur on unprotected metal surfaces, including components such as roof truss nailplates. Insulation materials may absorb moisture and lose their thermal effectiveness. Ceilings and decorations can be damaged by condensation soaking through. Mould growth can form, presenting a health hazard. Condensation may effect electrical wiring within the hidden roof and wall spaces. Items such as furniture stored in a loft space can be permanently damaged. 9 Insulation values can be effected by the build up of condensation TACKLING CONDENSATION Reduce the internal vapour pressure. Where possible remove the source of moisture within the building. Improve the internal ventilation and airflow, such as by opening windows and providing ventilation. Provide a continuous barrier to stop vapour entering the roof or wall. 8 6 5 7 The vapour control layer needs to be continuous and impose a substantially greater vapour resistance than the total of the elements above, i.e. the insulation / breather membrane / roofing or walling. A continuous vapour control layer will have the added benefit of reducing the amount of heated air escaping from a building. By stopping these draughts and reducing air convection losses the thermal performance of a building can be significantly improved. 1 4 3 Promote the release of moisture above the vapour control layer 2 Any vapour that does get past the vapour control layer needs to have a path out of the building with effective ventilation. Therefore minimise the external vapour resistance and allow the external skin to breathe. (See illustration left) six

The Importance of Vapour Control MEASURES TO IMPROVE THE EFFECTIVENESS OF A VAPOUR CONTROL LAYER 1. Respect the vapour control layer Through all stages of the construction sequence a high standard of care and attention must be given, from the original specification, detailing stages, storage of materials on site through to installation and final inspection. All members of the design and construction team should be fully aware that a roof with an ineffective vapour control layer can only be repaired properly by stripping the entire roof and starting again or by over-roofing. 2. Select a vapour control layer with high vapour resistance Industry guidance suggests that the vapour resistance of a vapour control layer within high risk roofs should be at least 500 MNs/g. The addition of an aluminium foil greatly enhances the vapour resistance. 3. Select a vapour control layer with good tear resistance - The importance of multifilament reinforcement. The vapour control layer is often subjected to reversals of wind pressure, causing the membrane to drum against supports. If there is room for movement and there are sharp edges, then the membrane can tear. It has been found that monofilament reinforced vapour control layers often have small pockets of air entrapped either side of their relatively bulky reinforcement, which reduces the tear resistance. 4. Provide good support On cold roof constructions where the vapour control layer is draped between purlins, the laps are extremely difficult to seal. This arrangement is best avoided and must not be used in high risk areas. Instead a rigid safe lining sheet should be provided for laying, jointing and sealing the vapour control layer. For advice on high risk areas please contact APG Techdesk. Warm roof constructions have the benefit of a structural deck directly below and offering good support. Rigid structural decks and safe walkable lining sheets are recommended to give full support for laying and sealing the vapour control layers. This is one of the reasons why the BRE recommends a warm deck roof above swimming pools. Over trapezoidal decking, the side laps should be above the crown of the profile, and the end laps should be supported on flat plates bridging the troughs. 5. Minimise the number of laps Where possible reduce the number of end laps to a minimum by using full rolls of sheeting. The laps should be at least 150mm wide. 6. Attention to detail The vapour control layers must be properly closed, sealed and fully integrated with wall structure, masonry, roof upstands, glazing heads, the roof perimeter and penetrations such as soil and vent pipes. Consider a clamped fixing arrangement which reduces the amount of air leakage. It is important that someone within the design team prepares large scale details of how these closures should be formed, ensuring that the materials will be readily available on site. 7. Good site practice. Monofilament Multifilament This is probably the most important factor of all in achieving an effective vapour control layer. It is essential that the site tradesmen are fully aware of the importance of the vapour control layer above warm and humid buildings, especially since their completed work will quickly be covered over as the roof is assembled. Weather plays an important part, particularly when dealing with lightweight membranes which blow around in the wind. With lap details ensure a butyl tape is used, which can be used in damp and cold climates. Probond would meet this criteria. Finally, any minor scuffs and punctures through a completed vapour control layer must be promptly repaired. seven

The Importance of Vapour Control CONDENSATION RISK ANALYSIS SOME USEFUL REFERENCES GROUP LTD The risk of condensation forming within a roof or wall construction can be predicted using the method described in BS 5250. It is usual for this analysis to be undertaken on computer, and this service is provided by the A Proctor Group Tecline. The starting point is to input the different layers of the construction, adding the thickness (mm), thermal resistivity (mk/w) and vapour resistivity (MNs/g.m) for each material. Next the internal conditions are required, preferably from site measurements. However, if they are not known, then the notional conditions for different building types can be taken from Table 1 (page5). The external summer and winter conditions averaged for a 60 day period are normally taken from BS 6229. The computer software computes the temperatures to the different interfaces of the construction and determines the associated saturated vapour pressure (svp). The cumulative vapour resistance is also computed, and where this is the same as the svp for any interface, then condensation is predicted. This can be plotted graphically as shown in the figure. Where the line meets the svp line, then condensation will occur. BS 5250: 2002 Control of condensation in buildings. BS 5427: Part 1: 1996 The use of profiled sheet for roof and wall cladding on buildings. BS 5534: 2003 Slating and tiling: design. BS 6229: 1982 Flat roofs with continuously supported coverings. BS 4016: 1997 Specification for building papers (breather type) The Building Regulations, Approved Document F2 Condensation in Roofs BRE Digest 270, Condensation in Insulated Domestic Roofs, February 1983. BRE Digest 336, Swimming Pool Roofs, Minimising the Risk of Condensation, September 1988. BRE Digest 369, Interstitial Condensation and Fabric Degradation, February 1992. BRE Report 262, Thermal Insulation: Avoiding Risks, Second Edition, 1994 Temperature Dew Point LAYER 1 1.2mm Metal Cladding LAYER 2 0.5mm Breather Membrane LAYER 3 120.0mm Thermal Insulation LAYER 4 0.4mm Vapour Control Layer LAYER 5 30.0mm Acoustic Insulation LAYER 6 0.9mm Liner NHBC Standards, Chapters 7.1 and 7.2 National Building Specification, Sections H30, H31, H60, H61, H65 Outside -5.0 o C 90.0%RH 2 3 4 5 6 Inside 30 o C 70.0%RH CIRIA / BFRC, Flat Roofing : Design and Good Practice, 1993 FRCAB, Roofing Handbook, Information Sheets 6 and 7, June 1988 NFRC, Profiled Sheet Metal Roofing and Cladding A Guide to Good Practice, Second Edition, 1991 Dewpoint / Interface temperature graph If the analysis does predict condensation it is important to assess the long term risk to the fabric. Will the timber rot? Would the insulation become ineffective? Could condensate drip into the building and stain ceiling tiles? There are limitations using condensation risk analysis as it is simply a one dimensional steady state model with a number of assumptions. However, the results can highlight the potential risk for a given construction and provide a timely warning. eight

The Importance of Vapour Control DIFFERENT TYPES OF MEMBRANE TO CONTROL WATER VAPOUR TO SUMMARISE, THE KEY POINTS ARE The A Proctor Group is unique in that they supply two different families of membranes to control water vapour within roof and wall constructions, each serving a different purpose. The Vapour Control Layer is a continuous membrane laid on the warm side of the insulation to reduce the amount of moist air escaping into the roof or wall construction. The Breather Membrane allows any moist air within the construction to pass out of the building while offering some weather protection from driving rain and snow. The vapour control layer must be: on the warm side of the insulation continuous treated with respect sealed at all laps sealed to and integrated with other elements such as wall heads, glazing heads, glazing upstands and soil and vent pipes. The breather membrane must be: behind the external weathering face continuous able to shed water out of the building of a high moisture vapour permeability Membrane Type Allows passage of water Go to page Water as a liquid Water as a gas Vapour Control Layer No No 10 Breather Membrane No Yes 17 Table 2 NBS SPECIFICATION Full NBS Specifications are available on the web site or alternatively contact our Techdesk. Tel No: 01250 872261 Web: www.proctorgroup.com nine

Product Selector Vapour Control Layers Procheck Standard 300 Procheck Premier 500 PRODUCT Procheck Premier FR 400 Profoil FS1 Profoil Code 850 859 835 862 861 Reinforced Translucent PROPERTIES Aluminium Foil Corrosion Resistant in chlorine environments UV Stabilised Fire Resistant APPLICATION high humidity moderate humidity low humidity Page Ref: 11 11 12 12 11 Table 3 ten

Membrane Information Sheets Procheck Standard 300 A lightweight reinforced polyethylene vapour control layer for use within roof and wall constructions to prevent warm, moist air escaping from inside the building and condensing within the insulation. The woven polypropylene multifilament scrim reinforcing provides good resistance to tears and punctures. Physical Properties Test Method Result Nominal Weight 152 g/m 2 Nominal Thickness 0.29 mm Tensile Strength BS 4415 Part 2 3.4 kn/m 2.4 kn/m Nail Tear Resistance MOAT No: 27 : 5.4.1 60 N 60 N Water Vapour Resistance ISO 9932 : 1990 336 MNs/g Moisture Vapour Transmission Rate ISO 9932 : 1990 0.61g/m 2 /day Roll Specification: Standard Roll Size: 50m x 2.0m Weight: 15 kg/roll Colour: Translucent Product Code: 850 Procheck Premier 500 A strong reinforced polyethylene vapour control layer with good vapour resistance. The woven extruded polypropylene multifilament scrim reinforcing provides improved nail tear resistance. The sheet is translucent to ease the installation and later inspection of support arrangements, and is the grade utilised by many leading system manufacturers. Physical Properties Test Method Result Nominal Weight 236 g/m 2 Nominal Thickness 0.37 mm Tensile Strength BS 4415 Part 2 6.2 kn/m 5.8 kn/m Nail Tear Resistance MOAT No: 27 : 5.4.1 180 N 170 N Water Vapour Resistance ISO 9932 : 1990 533 MNs/g Moisture Vapour Transmission Rate ISO 9932 : 1990 0.39 g/m 2 /day Roll Specification: Standard Roll Size: 50m x 2.0m Weight: 23.6 kg/roll Colour: Translucent Product Code: 859 Profoil A heavyweight reinforced vapour control layer with aluminium foil core to give a high water vapour resistance. The woven extruded polypropylene multifilament scrim reinforcement gives good resistance to tears and punctures. The aluminium foil is protected on both faces by polyethylene for corrosive situations, such as chlorine in swimming pools. Physical Properties Test Method Result Nominal Weight 310 g/m 2 Nominal Thickness 0.4 mm Tensile Strength BS 4415 Part 2 7.3 kn/m 7.3 kn/m Nail Tear Resistance MOAT No: 27 : 5.4.1 215 N 182 N Water Vapour Resistance ISO 9932 : 1990 Greater than 533 MNs/g Moisture Vapour Transmission Rate ISO 9932 : 1990 Less than 0.005 g/m2/day Roll Specification: Standard Roll Size: 50m x 2.0m Weight: Colour: 31 kg/roll Blue (top) Reflective Silver (bottom) Product Code: 861 eleven

Membrane Information Sheets Profoil FS1 A heavyweight reinforced vapour control layer with aluminium faces and good fire resistance properties. The multifilament polyester scrim reinforcement gives good resistance to tears and punctures. The exposed aluminium foil on both faces gives a high water vapour resistance and ensures low flame spread characteristics. Physical Properties Test Method Result Nominal Weight 297 g/m 2 Nominal Thickness 0.45 mm Tensile Strength BS 4415 Part 2 10.5 kn/m 9.3 kn/m Nail Tear Resistance MOAT No: 27 : 5.4.1 150 N 150 N Water Vapour Resistance ISO 9932 : 1990 Greater than 20,600 MNs/g Moisture Vapour Transmission Rate ISO 9932 : 1990 Less than 0.01 g/m2/day Roll Specification: Standard Roll Size: 50m x 1.5m Weight: 23 kg/roll Colour: Reflective Silver Product Code: 862 Procheck FR 400 A strong reinforced polyethylene vapour control layer with good vapour resistance. The woven polypropylene multifilament scrim reinforcing provides improved nail tear resistance. The addition of fire resisting compounds means that the material will not readily ignite and, although it will melt, will not continue to burn in small fires. Physical Properties Test Method Result Nominal Weight 240 g/m 2 Nominal Thickness 0.37 mm Tensile Strength BS 4415 Part 2 6.2 kn/m 6.1 kn/m Nail Tear Resistance MOAT No: 27 : 5.4.1 170 N 160 N Water Vapour Resistance ISO 9932 : 1990 428 MNs/g Moisture Vapour Transmission Rate ISO 9932 : 1990 0.48 g/m 2 /day Fire Resistance to Spread of Flame DIN 4102 B2 Roll Specification: Standard Roll Size: 50m x 2.0m Weight: 24 kg/roll Colour: Opaque Product Code: 835 Cladshield A single layer spun bonded polypropylene breather membrane designed for use primarily in lightweight industrial cladding systems. During site construction Cladshield is satisfactory if left open in fair weather prior to covering, but it cannot be regarded as temporary weather protection against wind driven rain and snow. Cladshield can also be used as a separation layer between some types of insulation and single ply membranes. Physical Properties Test Method Result Nominal Weight 100 g/m 2 Nominal Thickness 0.5 mm Tensile Strength: 56 days aged @ 60 o C BS 2782:320A 6.0 kn/m 4.0 kn/m Nail Tear Resistance MOAT No: 27 : 5.4.1 110 N 90 N Burst Strength, wet/dry BS 3137 500 kn/m 2 Water Vapour Resistance BS 3177 0.17 MNs/g Moisture Vapour Permeability BS 3177 1100 g/m 2 /day Resistance to Water Penetration (Eosin Test) BS 4016 Pass Fire Resistance to Spread of Flame DIN 4102 B2 Roll Specification: Standard Roll Size: 100m x 1.6m 100m x 3.0m Weight: Colour: 16 kg/roll, 30 kg/roll, Grey twelve

Details and Installation INSTALLATION OF VAPOUR CONTROL LAYERS 25mm 150mm Min 25mm Delivery and Site Handling Rolls of vapour control layers are delivered to site with tape identifying the product grade or membrane, or overprinted, clearly identifying product name and grade. Rolls should be stored flat or upright on a clean, level surface and kept under cover. Weather Conditions Laying lightweight membranes in high wind conditions is difficult and appropriate precautions should be taken during installation. Preparation of the Base Before installing the vapour control layer ensure that the surfaces to be covered are firmly fixed, clean, dry and smooth. Laps Lay the vapour control layer loose, flat and without wrinkles. Laps should be preferably sealed with two continuous runs of 15mm wide Probond RG tape. (see photo above) The minimum width of a lap should be 150mm. Adhesive PVC should not be used for sealing and jointing laps in vapour control layers. Puncture Damage Where puncture damage is unavoidable, apply good sized patches over the puncture, ensuring that there is a continuous bead of tape all the way around the hole. For small scuff type damage of less than 25mm as an alternative Profoil Tape may be used. Details Attention to detail is important. The vapour control layer needs to be continuous and particular care is required sealing around penetrations and at the perimeters where roofs and walls meet. thirteen

Details and Installation INSTALLATION OF BREATHER MEMBRANES Delivery and Site Handling Rolls of breather membrane are delivered to site, individually wrapped in a polythene sleeve. The sleeve has an identification tape with Product Name and Supplier Information. Rolls may be stored flat or upright on a clean, level surface and kept under cover. Metal roofs For sheet roof applications, the breather membrane should be laid either horizontally or vertically up the slope such that it forms a continuous membrane over the entire area of the roof, allowing any water to drain down to the gutters. On a low pitch metal roof, the draping of the breather membrane between purlins can result in ponding which is unsatisfactory and should be avoided. It is preferable for the breather membrane to be fully supported to give a clear drainage path. If this is not practical on low slope roofs then the laps should be taped using Proctor Breather Adhesive Tape to prevent water finding its way down onto the insulation below. At penetrations, such as vent pipes and rooflights, an additional piece of breather membrane should be laid upslope and taped in position, to channel water away to each side of the opening. Laying lightweight membranes in high wind conditions is difficult and appropriate precautions should be taken during installation. Wall Cladding For vertical Metal Cladding Application the breather Membrane should be installed on the outer side of the insulation. The membrane is usually installed vertically with laps of 100mm minimum as work progresses. Detailing of the membrane is important to ensure that the building is temporarily protected from rain during installation and that condensation will drain away once the external sheeting has been applied. Details Attention to detail is important. Avoid blockages where possible that would otherwise prevent the free drainage of water. A preferred specification is the use of an eaves carrier. fourteen

Preferred Details Metal Cladding Thermal Insulation Metal Lining BUILT UP METAL ROOF/ METAL SIDE CLADDING Breather Membrane Key point to watch: Ensure Vapour Control Layer is continuous and all laps and penetrations are sealed effectively Vapour Control Layer Figure 1 - Typical section Breather Membrane Key point to watch: The lap between the vapour control layers should be sealed with two continuous runs of 15mm wide Probond Tape. Vapour Control Layer Figure 2 - Ridge Key points to watch: 1. The vapour control layer in the wall needs to be effectively sealed to the vapour control layer in the roof. 2. The roof breather membrane drains freely into the gutter. Breather Membrane Vapour Control Layer Figure 3 - Eaves gutter Breather Membrane Key point to watch: 1. Ensure the Vapour Control Layer is fully sealed to the Top Hat with Probond Tape Also ensure the Top Hat is sealed to the pipe using a suitable sealant. Breather Membrane Vapour Control Layer Top Hat Vapour Control Layer 2. Ensure Breather membrane is turned up around pipe to prevent condensate draining into roof void. Figure 4 - Verge detail Figure 5 - pipe penetration fifteen

www.proctorgroup.com GROUP LTD Reg No. FM45117 ISO 9001 APG5450