Fire Resistance and Safety in Case of Fire



Similar documents
The Quality Connection. BETAflam Fire Resistant Safety Cables

Safety Storage Cabinets

Fire Performance Standard

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

The most important matter is to select the right product based on the environment in which it will be installed and on its use or application.

Flexible and safe solutions, for decades. Cables for alarmand safety systems

INTERNATIONAL STANDARD

Fire-Rated Glass and Glazing START

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Fire Safety Risk Assessment Checklist for Residential Care Premises

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

WHITE PAPER Fire & safety performance standards

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Fire Resistant Cables

RADOX railway cables acc. to EN and EN Edition 2009

Fire safety standards for LAN cabling systems

Decree of the Ministry of the Environment on fire safety of ventilation systems

exit routes and fire protection

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria

Tremco Fire Protection Systems Group Technical Bulletin

Certification of construction products - Fire dampers. Certification Rules 032

6 ELECTRICAL PARAMETERS

Comprehensive safety concepts for building applications

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

Fire Security Systems

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

An inventory of hazardous materials used in your workplace will prove useful.

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

D A T A C O M M U N I C A T I O N S C O M P E T E N C E C E N T E R

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

FIRE RISK ASSESSMENT

St. John s University

Comparative study for cables and busbars

English Version. Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

International Electrotechnical Commission Standards

Fire detection in kitchens

Fire Development and Fire Behavior Indicators

Mineral Insulated Cable A cable for today and tomorrow!

A Guide to the European Standard for Safety Storage Cabinets (BS EN )

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

FIRE SAFETY RISK ASSESSMENT

Emergency Response Guide

Installation Instructions for Alarm Module Kit A043F059

Global cable expertise for rolling stock

Name Of Occupancy Date. Yes No Describe

Composite Panel Firewall Systems

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

The soot and scale problems

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

Fire safety in timber buildings

DCSS (ACB) Data Center Fire Suppression Procedures

The proof is here!! Ron Goethals, Philadelphia; June 18, 2014

Services Enclosures and Protected Shafts - Maintaining Compartmentation

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

FLAMMABILITY REQUIREMENTS FOR AIRCRAFT SEAT CUSHIONS

1-085 Fire safety performance of materials

Fire. The Fire Installers Mate. A guide to fire alarm systems design

BS5839 Part 1:2002 Overview

INTERNATIONAL STANDARD

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

Fire Risk Assessment For Simple Premises

CONE CALORIMETER A TOOL FOR MEASURING HEAT RELEASE RATE

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

Portable digital microprocessor thermometers with interchangeable probes

PYROSWISS VETROFLAM CONTRAFLAM

Safe Operating Procedure

DIY Poly Digester. What is Supplied in the Kit. Sketch of Arrangement

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Explosion proof enclosures

1.0 Purpose Definitions Hot Work Operations. 5

Approval Standard for Plastic Suspended Ceiling Panels

Terms and Definitions In Canada

St. John s University Fire Safety Plan

HOT WORK PERMIT PROCEDURES

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Fire Testing of Recycled Materials for Building Applications

FIRE SAFETY ONLINE TRAINING

PREHEATING AUTOMATIC DRYING AND PREHEATING STATIONS

LESSON PLAN 1. Fire Science. Key Terms and Concepts. ash chemical reaction combustion Consumer Product Safety Commission endothermic exothermic

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

PYRAN PYRANOVA. Special-purpose glass products for fire resistant glazing

ELECTRICAL FUNDAMENTALS

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

Pyroguard Wired Glass

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Infrarot-Bewegungsmelder IP44

October Safety Subject

David O Brien, CMP Products (David.OBrien@cmp-products.com)

Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:

Piotr Tofiło a,*, Marek Konecki b, Jerzy Gałaj c, Waldemar Jaskółowski d, Norbert Tuśnio e, Marcin Cisek f

How To Test For Premer Retardant

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Transcription:

Fire Resistance and Safety in Case of Fire Franck GYPPAZ Nexans Research Center franck.gyppaz@nexans.com April 2014 Page 1/12

Table of content 1 Introduction... 3 2 Fire development... 3 2.1 Ignition... 3 2.2 Growth or propagation... 4 2.3 Full development... 4 2.4 Decay... 4 3 Fire Resistance and cable technology... 5 4 Cable fire resistance assessment... 6 5 CR1... 11 6 Conclusion... 12 Page 2/12

Flash over Temperature 1 Introduction One minute after a fire ignites, it is generally said that only one water glass is needed to extinguish it. After two minutes, one pail of water is needed, and after three minutes, the fire is out of control. Only firefighters or well-trained people can act to contain the disaster. Bearing this in mind, it is crucial to have the possibility of escaping the building as quickly as possible. In this event, pre-planned fire-safety strategy is paramount. Flame, fire, smoke detectors can be installed in all areas to alert people and allow their escape during the first stage of a fire. But for a well-developed fire, smoke is released and can reduce visibility. To remedy this, EXIT signs are used to help people find their way out. In addition, blinding and choking smoke is extracted via smoke exhaust systems. In all cases, the devices will have to be connected to the electrical system. The usual way is to use fire-resistant cable to enable electrical continuity even in extreme fire conditions. This White Paper aims to show how fire-resistant cables work, as well as to explain how their reliability and robustness impact on safety. 2 Fire development Generally speaking, the spread of fires in buildings follows four different stages of development, as showed here. Fire fully developed Fire extinction and escape possible Ignition Start of fire & propagation Role of fire reaction Role of fire resistance Time 2.1 Ignition Figure 1: Fire development The fire triangle (see Figure 2) illustrates the fire principle. To start burning, three different elements are necessary at the same time, in just the right proportion. They are heat, fuel and an oxidizing agent, usually oxygen. However, in flats, offices, two of them are always present. Page 3/12

Figure 2: Fire triangle The fuel consists of all of the materials: the furniture, computers, paper, combustible liquids, etc. Air brings the necessary oxygen into the room. In air, the oxygen content is 20.95%. Finally, only a simple spark or flame is missing to trigger the infernal process. This could occur because of a short circuit due to an electrical device malfunction or external events (fire in a garbage can, cigarette, etc.). 2.2 Growth or propagation Finally, the fuel is heated to a temperature at which it starts to decompose and release gaseous products. They diffuse into the flame, and undergo combustion in the gas phase, liberating more heat. Under steady-state burning conditions, heat is transferred back to the fuel surface, producing more volatile polymer fragments to sustain the combustion cycle. The overall temperature in the room increases and the fire continues to grow. By convection, the hot gases or particles ignite other items in the room. The pressure increases, and gases try to escape via openings igniting other fire sources. Furthermore, depending on the building construction thermal conductivity, a significant amount of energy can be transferred from one room to another increasing the likelihood of fire propagation. The higher the thermal conductivity, the higher the risk. 2.3 Full development In the case of a closed room, a flashover may occur if the overall temperature is high enough (500-600 C), with sufficient oxygen content. There is a sudden transition from a growth stage to a fully developed fire with a total surface involvement of all combustible materials. The internal pressure becomes huge in the enclosed space, leading to a possible explosion and aperture openings. At the same time, the heat released is at its maximum, and hot gases (as well as flames) can propagate far away from the starting point. Finally the fire spreads from one room to another following the same cycle, and conditions quickly threaten life and infrastructure. 2.4 Decay When the combustible material and/or the oxygen contents are not high enough to sustain the fire cycle, the fire starts to decay. This is obviously a good sign that the fire will stop soon. Nevertheless, it may be a trap. Page 4/12

Decay begins when the oxygen content is not high enough to sustain fire combustion. The heat released decreases, but the temperature can still increase for some time. Hot combustible particles and gases are still produced and can burst into flame again if fresh air arrives in the environment. 3 Fire Resistance and cable technologies During the first stage of a fire, the basic idea is to stop or reduce as much as possible its propagation and make possible fire extinguishment. At the same time, it ensures that people can be evacuated under safe conditions. Nexans has developed various fire-retardant systems, and proposes many of them under the trademark, ALSECURE, for building applications. When the fire is out of control, the situation becomes critical. It propagates quickly, releasing intense heat, opaque smoke and toxic substances, which drastically limit the possibility of escape. Here, special devices alert people to EXITs, and extract harmful substances, etc. Those safety elements must be connected to the power network. It is well known that standard smoke detectors are sometimes unreliable because people forget to test and change the batteries regularly. Also, fire-resistant cables are often used to provide power, or to make connections between emergency equipment. In this case, they function as active elements since they must maintain electrical continuity or transmit a signal for an adequate amount of time. Three main technologies are used to produce fire-resistant cables. Initial designs were based on copper conductors wrapped with mica tape(s) and cross-linked polyolefin. Here the core technology is the mica, and the cable performance is related to its quality, nature, suppliers, and taping. The second generation was based on silicone-rubber-insulated conductors. This material has the property of forming a ceramic shield when burning which maintains high electrical resistance. It is the most common solution for building applications. The last one is an innovative Nexans system known under the trademark INFIT. It combines the advantages of both mica and silicone rubber conductors without their drawbacks (mica is difficult to strip silicone is soft and brittle). Figure 3: INFIT insulation after fire Page 5/12

4 Installation concept for safety circuits Safety installations can be considered in two ways. The first one consists in placing fireresistant cables directly within cable management systems (trays, ladders, etc.), having at least equal performance in terms of integrity. This is done easily by standard assemblers. The second solution is more sophisticated and complex. The cables are drawn inside protective systems that are either pre-manufactured or built onsite. These have the advantage of ensuring fire resistance even for standard cables. The inside temperature is never higher than their failure point (>100 C). This special property can be reached, for example, using specific additives releasing water when exposed to high temperatures. Unfortunately, they are extremely sensitive to external threats, such as mechanical shocks. A small fissure is enough to make them unreliable, since heat will penetrate inside. In terms of installation, they are also much more expensive, and timeconsuming. Furthermore, certain building spaces have to be pre-allocated by the architects since they are bulky, and once installed, system maintenance is difficult. Another point is seldom raised. They can easily promote fire propagation inside the building. In the case of short circuit, the standard cables start to burn and the fire quickly progresses along a route throughout the building that is almost impossible to detect. Instead of providing protection, they become a threat. All things considered, it seems much more appropriate and far less expensive to install safety circuits using fire-resistant cables only. Fire Resistance for unprotected Electric Cables Cable Management Systems for fire resistant installations Manufactured Protective Systems for standard cables Built onsite Protective Systems for standard cables Figure 4: safety circuit installation concepts Page 6/12

5 Cable fire-resistance assessment As fire is of great concern, for many years, standardization bodies (IEC, CENELEC as well as national organizations) have been dealing with it. They have proposed various fire-resistant test protocols in order to assess cable reliability. The main differences consist in modifying the test duration, the fire/flame temperature, or adding mechanical stress and water sprays. Moreover, two different philosophies were used: either testing the intrinsic fire resistance of cables, or assessing the performance of cables with their associated management systems. The different testing protocols are described below: 5.1 Example of Intrinsic Fire Resistance protocols International: IEC 60331 part 11 and associated part 21, 23 and 25 IEC 60331-11 & -21 & -23 (cable horizontal on metallic rings) Cable diameter : mm Minimum length : 1200 mm Flame temperature 750 C Ring number : cable dia 10 5 cable dia 10 2 Voltage : cable nominal voltage Duration : 105 min (90min with fire + 15 min under voltage) Function continuity 105 min European: o EN 50200 EN 50200 / IEC 60331-2 («U» mounting on a fire proof frame) Cable diameter : 20 mm Minimum length : 1200 mm / test Flame temperature : 850 C Mechanical shock : each 5 min Bending radius : cable manufacturer Voltage : cable nominal voltage Duration : 15 30 60 90 120 min Function continuity 15-30 - 60-90 - 120 min Page 7/12

o EN 50200 with water spray EN 50200 Annex E & BS 8434-2 («U» mounting on a fire proof frame) Similar to EN 50200 with water spray Flame temperature : 850 C Duration : 30 min (15 min fire & Shock + 15 min fire & shock & water) BS 8434-2 Flame temperature : 950 C Duration : 120 min (60 min fire & Shock + 60 min fire & shock & water) Requirements : Function continuity 30 min (Annex E) Function continuity 120 min ( BS test) o EN 50362 EN 50362 / IEC 60331-1 («U» mounting on a metallic ladder) Cable diameter : > 20 mm Minimum length : 1500 mm Flame temperature 850 C Mechanical shock : each 5 min Bending radius : cable manufacturer Voltage : cable nominal voltage Duration : 15-30 - 60-90 - 120 min Function continuity 15-30 - 60-90 - 120 min France : NFC 32070 test n 3 NFC 32070 CR1 Cable horizontal place in a metallic tube if unarmoured Cable diameter : 0-40 mm Minimum length : 1200 mm Temperature ramp : from 20 to 920 C then a plateau for minimum 15min T = 345 Log (8t min +1) Mechanical shock : 1 each 30s on a tube or the cable if armoured Voltage : cable nominal voltage function continuity 65 min Germany: DIN VDE 0472 part 814 This test is similar to the IEC 60331-11 associated to part 21, except that the fire exposition is 3 hours at 400V plus 24 hours in voltage conditions without fire. Page 8/12

UK o BS 8434-2 (see EN50200 with water spray) o BS 6387 A, B, C, S BS 6387 cat A B C S (cable horizontal on rings) Minimum length : 1200 mm A : 650 C B : 750 C C & S : 950 C Flame temperature : A : 650 C B : 750 C C & S : 950 C Burner position : vertical Voltage : cable nominal voltage Duration : 180 min or 20min for cat S Function continuity 180 min Function continuity 20 min for Cat S o BS 6387 W BS 6387 cat W (cable horizontal on rings) Minimum length : 1500 mm Flame temperature : 650 C Water spray with sprinkler Voltage : cable nominal voltage Test duration : 30 min (15 min fire + 15 min fire & water) Function continuity 30 min o BS 6387 X, Y, Z Fire Testing - BS 6387 cat X Y Z («Z» mounting on a fire proof frame) X : 650 C Y : 750 C Z : 950 C Internal use Cable diameter : 0-20 mm Minimum length : 1200 mm Flame temperature : from 650 to 950 C mechanical shock : each 30s Bending radius : cable manufacturer Voltage : cable nominal voltage Test duration : 15 min Function continuity 15 min Page 9/12

5.2 Example of tests on systems Germany: DIN 4102-12 In this case the systems are tested at their nominal load (between 10 to 30kg/m). The cables are bent to form an S shape on the systems. Test in Furnace (system test DIN 1402-12) Minimum length : 4 m Fire temperature : from ambiant to > 1000 C ( T = 345 Log [8t min +1] ) Bending radius : cable manufacturer Voltage : 400V Duration : 30-60 - 90 min Function continuity 30 60 90 min Belgium: NBN 713020 Here there is no load on the system. The cables cross the wall and are sealed with concrete. Test in Furnace NBN 713020 Minimum length : 4 m Fire temperature : from ambiant to > 1000 C ( T = 345 Log [8t min +1] ) Bending radius : cable manufacturer Voltage : 400V Duration : 60-90 min Function continuity 60 90 min Europe and Future Construction Product Regulation: EN50577 As for DIN4102-12, the systems with a load of 20kg/m and the system shall be of the same class as the cables. Furthermore, cables are bend to form a U or S shape on the systems. Test in Furnace EN50577 Minimum length : 4 m Fire temperature : from ambiant to > 1000 C ( T = 345 Log [8t min +1] ) Bending radius : cable manufacturer Voltage : rated voltage Duration : 15 30-60 - 90-120 min Function continuity 15-30 - 60-90 -120 min Page 10/12

6 From intrinsic cable resistance to system resistance The NFC 323070 standard defines a test allowing the fire-resistance assessment of cables at rated voltage (500V). 1.5m of a cable is placed in a stainless-steel tube and placed in a tubular oven. This furnace heats the cable following the ISO834 timetemperature curve, and mechanical shocks are applied on the tube each 30 seconds. Under these conditions, the cable will maintain its electrical continuity for at least 65 min. Four to five tests will be satisfactory to attest cable conformity. NFC32070 CR1 fire test Protective system This performance was challenged by the French safety authorities, arguing that standard cables installed in 1 hour fire-resistant protective systems were much reliable, robust and safe. Indeed, protective systems using standard cables strongly compete in terms of safety with electrical installations based on fire-resistant cables only. A test initiative was implemented via the Sycabel (French cable association) and technically led by Nexans Research Center-Lyon. The strategy was to quantify the fire-resistant potential of CR1 cables installed on a fire-resistant tray when tested in a large oven simulating a real fire. The objective was to determine whether the electrical integrity was ensured for at least 1 hour. This kind of mounting has the advantage of being less expensive, less cumbersome, and easier to install in comparison with protective systems. The final results widely surpassed our wishes, as all 20 samples fulfilled the requirements (electrical integrity higher than 60 min) with a life-time average of 85 min. This conclusion was presented to the French authorities and validated as at least equivalent to standard cable installed in fire-resistant protective systems. Initially, it will allow us to install our current ALSECURE PLUS and ALSECURE PREMIUM ranges under the marking ALSECURE PLUS SECURISE and ALSECURE PREMIUM SECURISE in U10/J10 areas (hospitals, nursing homes). Moreover, it makes a bridge with the ongoing Construction Product Regulation (CPR). Very soon, fire-resistant cables will be tested this way according to the EN50577 test protocol. In short, the ALSECURE PLUS and ALSECURE PREMIUM ranges are extremely safe for highly sensitive public areas. Page 11/12

7 Conclusion In the case of fire, escape conditions drastically affect the possibilities for people to evacuate a building safely. The EXIT routes must be well identified. Visibility must be high enough to find their way out. People must be informed as soon as possible. And special devices, used to maintain the right conditions for as long as possible, must continue to function flawlessly: exhaust fans, fire/flame or smoke detectors, etc. Various safety strategies can be used to maintain the electrical integrity of safety circuits. It appears that fire-resistant cables and especially the ALSECURE PLUS and ALSECURE PREMIUM ranges installed on fire-resistant cable management systems are relevant, reliable and robust enough to ensure safety. They have demonstrated their intrinsic fire-resistance value and the ability to maintain electrical integrity when installed on cable management systems simulating real electrical installations. For architects and builders, this special solution is bound to be a preferred first choice in comparison to traditional protected systems. Page 12/12