Collimation of an Alluna Ritchey-Chrétien telescope



Similar documents
PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24

Alpy guiding User Guide. Olivier Thizy François Cochard

PROFESSIONAL REFRACTOR MODEL

FirstView 3 Reflector Telescope Owner s Manual

Instruction Manual Genesis 200 EQ

The MiniTower GOTO AltAz Mount with GPS and dual Mount set-up #8300

Your first. Buying a scope for the first time can be daunting. We reveal what you shoud look for and how to get up and running.

DSV-2 ALTITUDE-AZIMUTH TELESCOPE MOUNT User Manual

Parts List. The HyperStar Lens Assembly includes three pieces: HyperStar Lens Secondary Mirror Holder Counterweight

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Adjustment (Collimation) of Newtonian- and SC-Telescopes LASER-COLLI TM. Instruction Manual. with the help of the. by Baader Planetarium

ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

A Telescope Operating Manual

CALIBRATION FOR LAL20X & LAL24X

Refractors Give the Best Planetary Images

Yashica MAT EM posted '02

Handy Pinhole Camera (Latin Camera Obscura) to observe the transit of Venus, eclipses and other phenomena occurring on the Sun

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

Telescope Types by Keith Beadman

VISM Evolution Scope Series

Alignement of a ring cavity laser

How to buy a telescope for your institution

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

35mm Twin-Lens Reflex Camera

EnduraLAM 150 User Manual

Chelsea Loft Bed WARNING:

Alpy calibration User Guide. Olivier Thizy François Cochard

High Resolution Planetary Imaging Workflow

E q u a t o r i a l M o d e l Figure 1

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Woody s How To: MallinCam MFR-5 Focal-Reducer

Autoguiding Advanced Techniques

BODY-12, Door Handle - Removal, Installation, and Adjustment

9/16 Optics 1 /11 GEOMETRIC OPTICS

INSTITUTE OF THEORETICAL PHYSICS AND ASTRONOMY MOLĖTAI ASTRONOMICAL OBSERVATORY THE 35/51 CM TELESCOPE OF THE MAKSUTOV SYSTEM (ACT-452) USER'S GUIDE

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

ENGLISH Omni XLT Series Telescopes INSTRUCTION MANUAL Omni XLT 102 Omni XLT 102ED Omni XLT 120 Omni XLT127 Omni XLT 150 Omni XLT 150R

Diffraction of a Circular Aperture

Meade Instruments Corporation 6001 OAK CANYON, IRVINE, CALIFORNIA U.S.A. (949) FAX: (949)

Care and Use of the Compound Microscope

Without obstruction 20 % obstruction 33 % obstruction

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Choosing a Telescope

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

1000-LB. TRAILER JACK OWNER S MANUAL

90 EQ # EQ # EQ-MD # EQ-MD

Instruction Manual Meade 50AZ-P 50mm (2 ) Altazimuth Refracting Telescope

Warning : HαT telescope must NOT be used for solar observation without additional filters. This is the user responsibility to check that his filter

Gear PEPSI CAN STOVE INSTRUCTIONS

Honda CX500 & GL500 Forum

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

A Collection of Solar Finder Designs

Jupiter 8 Service. OR A TALE OF 4 JUPITER 8 s BY KIM COXON

K17.12 Door closers K17. Doors

The Wide Field Cassegrain: Exploring Solution Space

Manual LOGO 400 SE.

Time needed: ~3h for lid replacement only. Add 1h for operation harness in lid and ~2h more for installing drive unit and cable harness in trunk.

900X70 Refractor Telescope Instruction Manual

These Installation Instructions are valid for antennas in the following version:

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

Making a reflector telescope

EPSON SCANNING TIPS AND TROUBLESHOOTING GUIDE Epson Perfection 3170 Scanner

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up

Building an Off-Center Fixture for Turning Pendants

Tips when buying a telescope

Orion EQ-1 Equatorial Mount

SPRITE and BIGFOOT DESKTOP CNC MACHINE KIT ASSEMBLY INSTRUCTIONS

Features: Mounting the Optic

VISM CQB Scope Series

Speed-Mat Rectangle Cutter

Brief description and possible applications of the BAADER HYPERION EYEPIECES

Orion Atlas. EQ Mount INSTRUCTION MANUAL #9830. Customer Support (800) IN 177 Rev. A 11/02

Remote Head REMO ONE. Code Manual

Rodenstock Photo Optics

Manual HSK clamping technology

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Planetary Filters for Small Telescopes

Advanced MakeUp Tips by Kathy Whittington

S&G Model 2937 Group 1 Combination Lock

Manual for GlobePharma Mini-Press II Rotary Tablet Press

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

50 TO 60 INSTALLATION INSTRUCTIONS v1.0

Tips for Selecting Your First Telescope

H EAD TUBE BASICS. Figure 1 - Head tube, front fork and hardware

How to make a Galileian Telescope

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

Go-kart for little race-drivers

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

how to change a watch battery

MOVIEtube CR. Cinematography Rig. Setup Camera Sony PDW-F3 (MTCR-P-10-01) Version / English

Planning Observations

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

In this project, you will be observing at least three objects with a telescope or binoculars, and drawing what you see.

Celestial Sphere. Celestial Coordinates. Lecture 3: Motions of the Sun and Moon. ecliptic (path of Sun) ecliptic (path of Sun)

Interference. Physics 102 Workshop #3. General Instructions

Precision Vise Combinations

KAWAI VERTICAL PIANO REGULATION MANUAL

GREAT FOR VISUAL OBSERVATIONS, AS WELL AS DIGITAL IMAGING

Transcription:

Collimation of an Alluna Ritchey-Chrétien telescope This guide describes how to use your Alluna Ritchey Chrétien telescope in a few steps and adjust it perfectly in a matter of minutes. Collimation is best carried out in daylight. All telescopes are adjusted on the optical bench at the factory as well as possible. Should nevertheless, after shipping and installation, a collimation be necessary, then definitely only to a very small extent. Take care when turning the adjustment screws. Step 1 You require a Takahashi ocular adjustment and to connect to the telescope the adapter M100x1. The Takahashi ocular adjustment and the appropriate adapter that fits all of our RC telescopes, can be purchased from us as accessories. Step 2 Connect the ocular adjustment with the M100x1 adapter 1

Step 3 Then screw the adapter with the ocular adjustment on to the Alluna RC telescope M100x1 output. It is good to extend the output a little with the existing extension tubes. Step 4 The ocular adjustment is now firmly attached to the telescope. The optical axis matches exactly the subsequent use of CCD camera eyepiece or other accessories! Nothing will shake; everything is fitting tightly! Now, the aperture of the telescope should be directed towards a bright wall or white paper. It is advantageous if the telescope points upwards during adjustment, but in no case downwards. Step 5 When looking through the ocular adjustment look with a misaligned system at the accompanying picture. This system we have misaligned strongly for the explanation. The goal is now to make all the visible rings concentric. The ocular adjustment can be moved a bit back and forth. This can precisely be focused on the individual visible rings. 2

Step 6 There are three adjusting screws and three lock screws for the primary mirror and the secondary mirror. Step 7 First, the secondary mirror is always adjusted. Unscrew the three counter-open screws on the secondary mirror holder. By turning the adjustment screws on the secondary mirror holder the smallest inner white point moves which is the marking that is on the secondary mirror. This must be accurately centred to the second inner white ring. If the inner two white rings are centred on each other, the secondary mirror is adjusted already. Do not forget to tighten the counter screws on the 3

secondary mirror holder and at the same time check the adjustment. The locking screws do not need to be very tight. A light even tightening is sufficient. Step 8 Second, the adjustment of the main mirror is carried out. First, the three lock screws must be gently opened on the back plate. Now you need, when looking through the Tak-Colli-Scope, to ensure that the broader black circle is positioned in the slightly narrower outer black circle. Please compare the image on the left with image one above. If between the two circles a very thin white ring is seen uniformly, the primary mirror, and thus the whole RC system is fully adjusted. The adjustment is correct now to 96 to 100%, all takes 4

less than three minutes. The image on the left shows an almost perfectly aligned Alluna RC. If you look closely the main mirror still should be a little "hint" to the bottom right - there the white line is quite a bit wider. Please do not forget to tighten the lock screws of the primary mirror evenly (but not too tight!) while checking the adjustment with the Colli scope. Step 9 Check collimation on the real star With the adjustment on the day the RC should already be very well adjusted. The control and perfection of collimation, you can perform at night on a defocused star. It is best to use to your CCD camera on the telescope output. Then position a medium bright star in the centre. The star will then be defocused as far that you can see well the dark shadow of the secondary mirror in the star discs. If everything is perfect the shadow should be exactly in the centre of the star disc. If not you can readjust a little. Here only the primary mirror is adjusted. Please note that the star should always be in the middle of the image field. 5

Note: Through questions to us, we know that this manual is also used for adjusting Cassegrain and RC telescopes which are not used for Alluna Optics telescopes. Often the results do not meet the expectations of the Tak-Collimations scope. Please note that our RC telescopes are machined very precisely! This means that in Alluna Optics RC systems the primary mirror, the secondary mirror and the baffle tube and the spin is exactly centred on the axis in the OTA system. Mirror shifting of Alluna telescopes is virtually non-existent and the weak point of many telescopes is the focuser which we do not need. Alluna RC telescopes have a modern secondary mirror focusing. The Tak-Colli-Scope is firmly bolted to the telescope on the axis. Just like how the camera is positioned later. In other Cassegrain and RC systems, these axes often do not match, are slanted or shift during load changes (mirror shifting). Often an existing focuser is shaky or askew on the back plate. An adjustment of the visible rings with the Tak-Collimations Scope rarely leads to success in these telescopes. Such telescopes you need to adjust more frequently and directly as possible to the star at the zenith or the main direction of observation used on the observation evening. 6