Permanent Magnet Materials



Similar documents
Magnetic Media Measurements with a VSM

Insertion Devices Lecture 4 Permanent Magnet Undulators. Jim Clarke ASTeC Daresbury Laboratory

Anomalous Hall Effect Magnetometry A Method for Studying Magnetic Processes of Thin Magnetic Films

Measuring Permanent Magnet Characteristics with a Fluxmeter and Helmholtz Coil

Ajit Kumar Patra (Autor) Crystal structure, anisotropy and spin reorientation transition of highly coercive, epitaxial Pr-Co films

CHAPTER 5: MAGNETIC PROPERTIES

2. Permanent Magnet (De-) Magnetization 2.1 Methodology

PERMAGRAPH L. for the computer controlled measurement of hysteresis curves of hard magnetic materials. Introduction.

Figure 1 Hysteresis loop of ferromagnetic material

Guide to Magnetic Materials

KOLEKTOR MAGNET TECHNOLOGY

Nd-Fe-B Magnets, Properties and Applications

EFFECT OF PARTICLE SIZE DISTRIBUTION ON THE MICROSTRUCTURE AND MAGNETIC PROPERTIES OF SINTERED NdFeB MAGNETS

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

UNDERSTANDING PERMANENT MAGNET MATERIALS; AN ATTEMPT AT UNIVERSAL MAGNETIC LITERACY. S. R. Trout Molycorp Magnequench

X-Ray Study of Soft and Hard Magnetic Thin Films

HANDBOOK OF MODERN FERROMAGNETIC MATERIALS

d di Flux (B) Current (H)

HIGH SPEED PERMANENT MAGNET SYNCHRONOUS MOTOR / GENERATOR DESIGN FOR FLYWHEEL APPLICATIONS

Guide to Magnet Design

Edmund Li. Where is defined as the mutual inductance between and and has the SI units of Henries (H).

5. Measurement of a magnetic field

A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS

DIRECT CURRENT GENERATORS

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

SYNCHRONOUS MACHINES

Materials Research for Advanced Data Storage

1 CHAPTER 12 PROPERTIES OF MAGNETIC MATERIALS

FEATURES AND BENEFITS OF DIFFERENT PLATINUM ALLOYS. Kris Vaithinathan and Richard Lanam Engelhard Corporation

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

ABSTRACT 1. INTRODUCTION

Demagnetization Studies on Permanent Magnets - Comparing FEM Simulations with Experiments

HALL EFFECT SENSING AND APPLICATION

Magnetic Materials: Hard Magnets

Lecture 19: Eutectoid Transformation in Steels: a typical case of Cellular

13 ELECTRIC MOTORS Basic Relations

Motors and Generators

Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox

Force on a square loop of current in a uniform B-field.

Experiment: Crystal Structure Analysis in Engineering Materials

Magnetic susceptibility. Basic principles and features on the PPMS.

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: Solon Road FAX:

Chapter 13: Applications of Hard Magnets

HALL EFFECT SENSING AND APPLICATION

maxon DC motor Permanent magnet DC motor with coreless winding

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS

Design and Analysis of Switched Reluctance Motors

Comparison of Synchronous Machines with Neodymium and Ferrite Magnets for Electrical Traction Systems

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

Alternative Linear Motion Systems. Iron Core Linear Motors

Magnets and their specifications

Chapter 7. Magnetism and Electromagnetism ISU EE. C.Y. Lee

How to Optimize Performance and Minimize Size in High Speed Applications High Performance Brushless DC Motors

Iron core Material-Somaloy Unique magnetic properties High purity iron powder Electrically insulated surface. Result in.

Crystal Structure of Aluminum, Zinc, and their Alloys By: Omar Fajardo Sebastian Henao Devin Baines ENGR45, F2014, SRJC

Physics 221 Experiment 5: Magnetic Fields

HOW ACCURATE ARE THOSE THERMOCOUPLES?

Mutual Inductance and Transformers F3 3. r L = ω o

INDUCTOR DESIGN IN SWITCHING REGULATORS

To measure the solubility of a salt in water over a range of temperatures and to construct a graph representing the salt solubility.

Physical Specifications (Custom design available.)

MSE PRECIPITATION HARDENING IN 7075 ALUMINUM ALLOY

Application Note. So You Need to Measure Some Inductors?

Glancing XRD and XRF for the Study of Texture Development in SmCo Based Films Sputtered Onto Silicon Substrates

Capacitors in Circuits

A Practical Guide to Free Energy Devices

The Electrical Properties of Materials: Resistivity

The performance improvement by ferrite loading means - increasing, - increasing of ratio, implicitly related to the input impedance.

Application Information

THE EFFECT OF THE HDDR PROCESS ON THE PRODUCTION OF Pr-Fe-Co-B-Nb SINTERED MAGNETS

Embedded Integrated Inductors With A Single Layer Magnetic Core: A Realistic Option

Chapter 14: Inductor design

Magnet FAQs. Steve Constantinides, Director of Technology Arnold Magnetic Technologies Corporation February 7, Arnold Magnetic Technologies

A Comparison of FC-0208 to a 0.3% Molybdenum Prealloyed Low-Alloy Powder with 0.8% Graphite

Magnetic Dipoles. Magnetic Field of Current Loop. B r. PHY2061 Enriched Physics 2 Lecture Notes

Brush DC Motor Basics. by Simon Pata Business Unit Manager, Brushless DC

The Calculation of G rms

Two bar magnets are brought near each other as shown. The magnets... A) attract B) repel C) exert no net force on each other.

CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager

T. R. Ní Mhíocháin and J. M. D. Coey Physics Department, Trinity College, Dublin 2, Ireland.

ES250: Electrical Science. HW7: Energy Storage Elements

Ampere's Law. Introduction. times the current enclosed in that loop: Ampere's Law states that the line integral of B and dl over a closed path is 0

Magnetic Field of a Circular Coil Lab 12

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Materials Standards for Metal Injection Molded Parts

Miniature High-Torque, DC Servomotors and DC Gearmotors

Introduction to Linear Actuators: Precision Linear Motion Accomplished Easily and Economically

Introduction to Electricity & Magnetism. Dr Lisa Jardine-Wright Cavendish Laboratory

RARE-EARTH PERMANENT MAGNETS: NEW MAGNET MATERIALS AND APPLICATIONS

FORCE ON A CURRENT IN A MAGNETIC FIELD

Objectives. Capacitors 262 CHAPTER 5 ENERGY

Eðlisfræði 2, vor 2007

Demagnetization Tests Performed on a Linear Alternator for a Stirling Power Convertor

An Introduction to AC Field Hall Effect Measurements

INNOVATIVE ELECTROMAGNETIC SENSORS

Transcription:

Measurements with a VSM Permanent Magnet Materials B. C. Dodrill B. J. Kelley Lake Shore Cryotronics, Inc. 575 McCorkle Blvd. Westerville, OH, 43082 Please address correspondence to bdodrill@lakeshore.com

Introduction Permanent magnet materials are of growing interest to the electronics industry and to manufacturers of electro-mechanical devices in that they constitute indispensable elements in many electronic apparatus, circuits, electric motors, consumer, and defense products. The magnets have major influence on the size, efficiency, stability, and cost of these devices and systems. The development of rare-earth magnet materials in the 1970 s profoundly and positively influenced the application of permanent magnet materials owing to their large energy product and increased volume efficiency. The rareearth alloy magnets that have been most extensively studied and developed are SmCo and NdFeB. The presence of rare-earth metals in magnet alloys has a surprising influence on magnetic properties, and hence measurement of magnetic properties is exceedingly important in connection with research and development of new magnet materials. In a similar vein, magnetic measurements are utilized in magnet production and manufacturing environments to ensure quality in the end product and to provide critical process control feedback concerning the magnet manufacturing process itself. This application note will discuss the utility of the Vibrating Sample Magnetometer (VSM) measurement methodology in the characterization of permanent magnet properties, with a particular emphasis on SmCo rare-earth magnet materials. Magnetism and the Permanent Magnet Process A permanent or hard magnetic material retains magnetism or remanence even in the absence of an applied magnetic field and exhibits a large intrinsic coercivity, i.e., the field required to demagnetize the material. Alternatively, magnetically soft materials require application of an external field to exhibit useful magnetic properties, and typically exhibit very small coercivities. The demagnetization curve or 2 nd quadrant of the M(H) or B(H) loop is the most often measured property that dictates a permanent magnets suitability as a magnetic device. Its shape contains information concerning how the magnet will operate under static and dynamic conditions, and hence is a critical parameter in determining the suitability of the material for a specific application. The desirable qualities of a permanent magnet material are; high coercivity (H ci ), high saturation magnetization (M sat or B sat ), high remanence (M rem or B rem ), high energy product (BH) max, and nearly linear 2 nd quadrant B(H) characteristics. Many permanent magnet materials are manufactured so that magnetic properties are enhanced along a preferred axis. This is realized if the crystal lattice structure of the material itself has preferred directions for alignment of the magnetic moments, and is referred to as magnetocrystalline anisotropy. Other permanent magnet materials are manufactured using processes that establish a net alignment of needle-shaped particles or platelets. These magnets base their properties on the shape anisotropy of the particles, where the shape of the particles produces an internal field which may differ from the applied field, leading to enhanced coercivity along the particle major axis. The most widely used type of permanent magnet material is the class of ceramic ferrites which are made from iron oxide, Fe 2 O 3. These are fine particle magnets produced by powder metallurgical methods. They exhibit high coercivities and nearly linear demagnetization curves, and are particularly well suited for many applications, including electric motors. The magnetism of ferrites is founded in the magnetocrystalline anisotropy of the particles.

Figure 1 M(H) and B(H) curves for a sintered NdFeB sample. These data were recorded using a superconducting magnet-based VSM. Alnico magnets represent another commonly used permanent magnet material. In these materials, elongated magnetic particles are precipitated throughout the matrix of an Al-Ni-Fe-Co alloy during the manufacturing process. The magnetism of these materials is due to the shape anisotropy of the particles. It became apparent in the 1960 s that attempts to further enhance or improve the magnetic properties of ferrites and alnico magnets were exhausted. The search then began for other materials with high uniaxial magnetocrystalline anisotropy, high coercivity, and high saturation magnetization. Rare-earth magnet alloys represented the most promising candidates, and advances in the development of these magnetic materials over the last 30 years have had a profound, and far-reaching impact on magnetic devices. The rare-earth magnet materials that have gained the most attention include alloys of SmCo 5, Sm 2, and Nd 2 Fe 14 B. It was believed that the cost and availability of the principle constituents in SmCo would limit their commercial success, so in the 1980 s considerable effort was expended to replace scarce Co with abundant Fe in combination with rare-earth metals, ultimately leading to the development of NdFeB magnets. The question of whether Sm or Nd alloys are preferred depends critically on the specific application to which the magnet material will be used. Where the energy density of Nd alloys is superior to the Sm alloys, the Sm alloys strength is in its thermal stability. For applications where the temperature is stable and to just above room temperature, NdFeB is a better choice. Conversely, for those applications where the temperature may vary significantly, or the magnet material may be subjected to elevated temperature environments, SmCo is a better choice. The Hysteresis Loop: M(H) and B(H) A typical full or major hysteresis loop for a NdFeB sintered magnet is illustrated in figure 1, where both the magnetization M and magnetic induction B are presented. Some of the pertinent parameters extracted from such loop measurements are indicated in the figure. In the context of permanent magnet materials, the 2 nd quadrant is the most pertinent in connection with the utilization of a magnet material in a magnetic device The Vibrating Sample Magnetometer (VSM) is based on vibrating a sample in a magnetic field to produce an alternating emf within a set of suitably placed pick-up or sensing coils. This induced emf is directly proportional to the magnetic moment m or magnetization M of the sample under test. VSM s are used widely since magnetic properties can be measured for a diverse range of sample sizes and configurations, i.e., powders, solids, single crystals, thin films, and liquids, and because they are particularly well suited to allow measurements at both low and high temperatures. In the development of rare-earth magnet materials the VSM has been used extensively to measure saturation, remanence, coercivity, anisotropy fields, etc., and also to measure temperature dependent parameters of interest, for example Curie temperatures. The VSM is an open loop measurement in that the sample and field source (e.g., electromagnet) do not constitute a closed flux line loop. Hence the measured parameters must be corrected for demagnetization effects to yield the true intrinsic material parameters most often of interest for permanent magnet materials. In the open loop measurement, the internal field experienced by a sample differs from the applied field owing to an internal demagnetizing field which depends on the sample geometry under test.

The VSM measures magnetic moment m as a function of applied field H applied. The equations that relate open loop (VSM) to closed loop (BH looper) measurements are (cgsunits): Eq. 1) M(G) = 4pM = 4pm/V where M is the volume magnetization in units of emu/cc, and V = sample volume. The internal magnetic field is related to the applied field via, Eq. 2) H int = H applied - 4pN D M Figure 2 M(G) and B(G) vs. H int for a Sm 2 magnet material at 25 C. where N D = sample demagnetization factor (in SI units), and M is as defined in eq. 1. Values for N D may be determined empirically or analytically, and there are countless references containing demagnetization corrections for various sample geometries. The magnetic induction B and magnetization M are related via, Eq. 3) B = H int + 4pM = H applied + 4pM(1 - N D ). Provided N D values can be determined with reasonable accuracy, the VSM measurement can be used to derive the B(H) curve which is measured directly in the closed loop measurement. Closed loop measurements (BH loopers and hysteresisgraphs being the most common) allow freedom from demagnetization corrections and directly measure the magnetic induction B. The usual practice is to place a magnetic sample between the pole pieces of an electromagnet. The change in flux density of the sample is determined by integration of the induced voltage in a search coil that is wrapped around the sample using a fluxmeter. The sample is in physical contact with the electromagnet pole caps, thus constituting a closed circuit, and therefore eliminating the need for demagnetization corrections since the internal and applied fields are identical. Figure 3 M(G) and B(G) vs. H int for a Sm 2 magnet material at 300 C. Regardless of which technique is used, since the portion of the hysteresis loop that is most often of interest is the demagnetization curve or 2 nd quadrant, it is common to first magnetize a sample specimen to saturation using a magnetizer, and then measure only the 2 nd quadrant M(H) or B(H) characteristics. The magnetization M measured in a VSM may be converted to induction B. Thus, the VSM yields information essentially identical to that acquired in a closed loop measurement if demagnetization corrections are made. The advantages the VSM provides over closed loop measurement techniques are: magnetization M is measured directly, full loop characteristics can be measured to very high fields using superconducting magnet technology, a wider array of sample configurations can be accommodated, and variable temperature measurements are more readily adapted to the VSM configuration. This latter capability is of particular merit in connection with magnetic property measurements of permanent magnet materials since a knowledge of thermal stability versus demagnetization is requisite to application specific magnet design. The remainder of this application note will present VSM M(H) and B(H) data for SmCo samples, and will compare these results with closed-loop (hysteresisgraph) data.

Sm 2 : Measurements With a VSM To compare results obtained using the open loop VSM technique with closed-loop methodologies, demagnetization curves were measured for Sm 2 samples at ambient and elevated temperatures, and compared with hysteresisgraph data. To effect demagnetization corrections, magnet samples were fabricated with a right circular cylinder geometry, from which demagnetization factors N D could be determined with reasonable accuracy. The samples were oriented such that the cylinder axis was at right angles to the applied magnetic field. For this particular sample geometry and field orientation, N D»» 0.3 (in SI units). The sample was initially magnetized to saturation, and then the 2 nd quadrant M(H) characteristics measured in the VSM at room temperature (i.e., 25 C). The M(H applied ) data was then converted to B(H int ) using equations 2 and 3 above to determine; H ci, H c (B = 0), B rem, and BH max. Figure 4 M(H,T) curves for the SmCo magnet material. A VSM furnace assembly, which provides variable temperature capability to 1000 C, was used to conduct M(H,T) measurements at 300, 400, and 500 C. At these elevated temperatures, applied fields of only 15 koe were sufficient for saturation, hence the sample s M(H) characteristics were measured from +15 koe to -15 koe for both saturation, and measurement of the resultant demagnetization curve. Figures 2 and 3 illustrate results of the VSM measurements at 25 C and 300 C, respectively. Both M(G) (eq. 1), and B(G) (eq. 3) are plotted together as a function of the internal (demagnetization corrected) field (eq. 2). Tabulated below are the magnet performance parameters vs. temperature. Figures 4 and 5 show the family of M(H,T) and B(H,T) curves respectively, and graphically illustrate the thermal degradation of magnet properties with increasing temperature. T( C) B r (kg) H ci (koe) BH max (MG Oe) H c (B = 0) (koe) 25 8.95 12.12 19.2 8.61 300 7.91 9.307 14.7 7.139 400 7.38 8.311 12.7 6.438 500 6.59 6.911 9.78 5.466 Figure 5 B(H,T) curves for SmCo magnet material. To compare performance between the VSM and closedloop measurement techniques, another Sm 2 sample (cubic geometry) was measured employing both a VSM and a hysteresisgraph. The sample measured exhibits an energy product in excess of 30 MG Oe, and an intrinsic coercivity near 30 koe at room temperature. Since neither the VSM or hysteresisgraph used in this comparative investigation were capable of producing fields of this magnitude, measurements were conducted at 300 C, where H ci values were within both instruments field range capabilities. The VSM data are shown in Figure 6, and the results of both measurements are tabulated below. These results agree to the few percent level, and thus demonstrate that the VSM is capable of producing results essentially identical to the closed-loop hysteresisgraph measurement. VSM Hysteresisgraph % Variation B r (kg) 10.6 10.38 + 2.1% H ci (koe) 7.573 7.78-2.7% H c (B = 0) 6.795 6.80 < 0.1 % BH max (MG Oe) 24.1 23.42 2.9%

Intrinsic Coercivity: Rate Dependence In comparing measured coercivity values between various, or even identical measurement methodologies, it is important to ensure that the field ramp rate is identical. Many magnetic materials (particularly dispersions) exhibit an intrinsic coercivity which is dependent on field ramp rate, i.e., H ci µln(dh/dt). This property has been extensively studied for certain types of magnetic materials, e.g., particulate recording media, thin film media materials (hard disks), etc. In producing SmCo magnet materials, the constituent powders are mixed together, a reduction/diffusion process is applied to segregate the desired SmCo stoichiometry, and then the particles are milled to the desired final size, typically 5-10 mmm. The materials are multi-phase with complicated microstructures, and therefore also exhibit rate dependent characteristics. Figure 6 M(G) and B(G) at 300 C for a high energy product (>30 MG Oe) SmCo magnet material. Tabulated below are H ci values vs. field ramp rate, dh/dt, for a SmCo alloy. These results are illustrated graphically in Figure 7 where H ci vs. ln(dh/dt) is presented. It s clear that if measurement comparisons between open-loop/closed-loop, or between identical measurement techniques are attempted the field ramp rate must be similarly identical. dh/dt (Oe/s) H ci (koe) 20 6.76 25 6.777 33.3 6.796 50 6.829 75 6.862 200 6.965 Conclusions Figure 7 H ci vs. ln(dh/dt) for a SmCo magnet sample. This application note has discussed the utility of the Vibrating Sample Magnetometer (VSM) measurement methodology for characterizing the demagnetization curve properties of permanent magnet materials. Open-loop (VSM) and closed-loop (hysteresisgraph) results have been compared, and agreement to the few percent level has been demonstrated, provided sample demagnetization corrections are employed. The effect of field ramp rate on the intrinsic coercivity has been discussed, and the VSM s capability for investigating elevated temperature characteristics of permanent magnet materials has also been demonstrated. Acknowledgments Lake Shore gratefully acknowledges Electron Energy Corp for the magnet samples used in this study, and for their collaboration. References 1) Ferromagnetism, R. M. Bozorth, IEEE Press NY, 1951 (original publication date). 2) Advances in Permanent Magnetism, R. J. Parker, John Wiley & Sons NY, 1990. 3) Permanent Magnet Materials and Their Applications, P. Campbell, Cambridge Univ. Press UK, 1994. 4) Rare Earth Metals Based Permanent Magnets, editors F. Andriessen & M. Terpstra, Elsevier Applied Science UK, 1989. 5) Introduction to Magnetism and Magnetic Materials, D. Jiles, Chapman and Hall NY, 1991. Copyright Lake Shore Cryotronics, Inc. 1999