SimplyGo Quick-start guide



Similar documents
Simplify with SimplyGo. Now one POC meets the portable oxygen needs of nearly all of your patients

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

Oxygen simplified EverFlo concentrators reduce the cost of oxygen therapy

What you should know

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

Fits in the palm of your hand. Small and mighty. Stardust II portable diagnostic system

Trilogy accessory guide

Philips Respironics CEU Programs

SimplyGo Promotion Tools user guide

IntelliVue to go. IntelliVue MX40 wearable patient monitor

Restoring a good night s sleep

R0 JH 11/3/11. SimplyGo

Table of contents. Exercise 1 Passive exhalation port 13. Exercise 2 Active exhalation valve 15

A simple solution for your complex patients. The market-leading servo ventilation device System One BiPAP autosv

Titration protocol reference guide

US pricing, advertising, and sales channel policy

Obstructive sleep apnea and type 2 diabetes Obstructive Sleep Apnea (OSA) may contribute to or exacerbate type 2 diabetes for some of your patients.

OXYGEN WITHOUT COMPROMISE

Having a home sleep study? Rest easy. This booklet is designed to answer common questions you may have concerning your upcoming sleep study.

A new way of thinking. Philips Sparq regional anesthesia and pain medicine ultrasound system

Impact Uni-Vent 754 Portable Ventilator

Expand your view. IntelliVue MX600, MX700, and MX800 bedside patient monitors

Canadian pricing, advertising, and sales channel policy

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

HP ProDisplay P19A LED Backlit Monitor. User Guide

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Reocor D External Pacemaker

I have sleep apnea. Now what? A guide to getting the most out of your treatment

MAINTENANCE & TROUBLESHOOTING

Improve your image. ClearVue 350 ultrasound system. The print quality of this copy is not an accurate representation of the original.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Heart of America Medical Center EMR, EMT, EMT-Intermediate & AEMT Protocols

Home Healthcare Solutions

Instructions - THP-700RTS Telephone Headset Radio Transfer Switch with Dry Switch Closure Output

Helpful hints for filing

EverFlo. EverFlo Q EN, DE DSF 4/16/08

Table Of Contents

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

You ll love the Vue. Philips IntelliVue Information Center ix

Dolphin 6500 Mobile Computer. with Windows CE 5.0. Quick Start Guide

PrintPAD CN3/4/3e/4e. User Guide

High-intensity performance. IntelliVue MP90 patient monitor

Connected Care. Philips HeartStart connectivity and data management for EMS professionals

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

CINEMA SB100 powered soundbar speaker

Important Safety Instructions

Introduction. Intended use. Contraindications. General warnings and cautions. Patient Instructions WARNING CAUTION. English

MAINTENANCE & TROUBLESHOOTING

Networked versatility. IntelliVue MP60 and MP70 patient monitors

Replacing the Gateway M675 Keyboard

Infinity C Reference Guide

MZ Series Overview. Introduction. (MZ 220 Illustrated)

Table of Contents. REMstar Auto User Manual 1

PA500II Enterprise Mobile Computer

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Always in touch. Philips PageWriter TC50 cardiograph

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

4.3-inch Back-Up Camera

Magic Remote OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

HP ENVY 24 IPS Monitor. User Guide

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

HP Compaq LE1902x, LE2002x, LE2002xm, and LE2202x LED Backlit LCD Monitors. User Guide

Not just a new ultrasound, a new vision. Philips VISIQ ultrasound

ER102. Emergency Crank Weather Radio Owner s Manual.

Critical Care Therapy and Respiratory Care Section

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

CPAP System User Manual LK 5/12/01

VersaCare Bed. Quick Reference Guide

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE

ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting

PowerPoint Presentation

SYMBOL MC9060 HAND HELD TERMINAL USER MANUAL

HP Bluetooth Pendant Headphones User Guide

GE Simon XT Quick User Guide

Your Simple Guide to Battery. Replacement. Customer Care:

Critical Care Therapy and Respiratory Care Section

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Inogen Minimum Advertised Price (MAP) Policy

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

USER GUIDE. notebook security DEFCON 1# ultra combination cable lock

A passion for patients. Philips Patient Monitoring Services

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Replacing the Gateway M320 Keyboard

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Nokia Bluetooth Headset BH-800 User Guide Issue 2

Radio Dock Adapter Provides alignment and support for your Radio. (Interchangeable for different model Radios.) Radio Connector Module B Rear View

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory

OxySense Portable Series Instrument Quick Start Guide

Impact Uni-Vent 750 Portable Ventilator

Connecting to an AC Power Outlet (Optional) General Description. a Connect the AC adapter to the printer. b Connect the AC power cord to the AC

Advantium 2 Plus Alarm

Hi! Let s get started.

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Reizen Atomic Talking Analog Alarm Clock Item # Instruction Manual

DAB+ / FM Tuner Model: TU-201

On the Go with Oxygen

HP 2400/2500 Ultra Light Docking Station User Guide

GPSMAP 78 series. quick start manual. for use with the GPSMAP 78, GPSMAP 78s, and GPSMAP 78sc

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

Transcription:

SimplyGo Quick-start guide

Getting started This guide is intended to help you get started using the SimplyGo portable oxygen concentrator. If you have questions that are not answered in this guide, please consult the SimplyGo User Manual or contact your homecare provider. Important: The first time you charge the battery, be sure to charge it fully. Do not use the DC power cord for initial charge; instead use AC power. Charge the battery using the AC power cord. Before using SimplyGo for the first time, the battery requires an initial uninterrupted charging time of four hours minimum. This can be accomplished by installing the battery (see step 2 of Quick-start instructions) and using the AC power cord. To charge the battery using the AC power cord provided with your system, follow these steps: 1. Connect the AC power supply s output cable to the SimplyGo power input connector located on the upper right side of the unit. 2. Connect the AC power cord s connector to the AC power supply. 3. Connect the AC power cord s plug to an AC outlet.

Control panel display 1 2 3 4 5 6 1. Power Turns SimplyGo on and off 2. Alarm silence Turns the audible alarm off 3. Mode Selects one of the three possible operating modes 4. Display screen Shows information about the operating status of the device 5. Plus (+)/minus (-) + Increases the displayed setting; - Decreases the displayed setting 6. Cannula connector Oxygen output and connection point for cannula

Quick-start instructions 1. Attach the shoulder strap to the carrying case. Slide SimplyGo into carrying case, secure, and attach shoulder strap if desired. SimplyGo can be operated in or out of the case. 2. Insert the charged battery into the device. There is only one way the battery can be inserted into SimplyGo. Using its handle, position the battery over the battery compartment, lower into place, and press until it snaps into place. After the battery is inserted, check to make sure the battery handle is level with or slightly below the top of the plastic case. 3. Connect a nasal cannula to the oxygen outlet on top of the device. Connect a nasal cannula to the top of SimplyGo. To avoid a disruption of oxygen, route the cannula so that it is not pinched or kinked. A standard single lumen nasal cannula and tubing should be used. SimplyGo works with cannula tubing up to 30 ft. (9 m).

4. Turn on SimplyGo. Turn the device on by pressing the Power button twice. After the first press, the display screen and the button backlights turn on. Press the Power button a second time to place the device in operating mode. This second press helps prevent unwanted starts or inadvertent changes in oxygen flow. The introductory screen momentarily appears followed by the final operating mode screen. 5. Set the mode. Press the Mode button. Note: If the device is operating and the screen is dark, the first press turns on the screen backlight. In this case, press the button a second time to select the mode. Continue pressing the Mode button to scroll through the Pulse, Continuous Flow, or Sleep modes. When the desired mode appears in the display, stop pressing the button and wait. The display will return to the run time screen of the mode you selected, and the device will operate in this mode.

6. Set the flow rate. To set the device s flow setting, press either the + or button. To increase the flow setting, press the + button. To decrease the flow setting, press the button. The device can be set to 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, and 6 in Pulse or Sleep mode. SimplyGo can be set to 0.5, 1, 1.5, and 2 in Continuous Flow mode. Always verify the flow rate when turning on SimplyGo. Mobile cart operation To set up and use the mobile cart, follow these easy steps. 1. Set the mobile cart on a level surface, hold the handle with one hand, and open the base support. 2. With SimplyGo properly positioned in its carrying case, place the device on the base of the cart and secure using the elastic strap on the back of the case.

Oxygen delivery modes Pulse mode When SimplyGo is in the Pulse mode, it detects when the user begins to take a breath and then delivers a pulsed volume of oxygen determined by the setting number. Continuous Flow mode In Continuous Flow mode, a constant flow of oxygen is supplied based on the setting number (in liters per minute). When the desired mode appears in the display, stop pressing the button and wait. The display will return to the run time screen of the mode you selected and the device will operate in this mode. Sleep mode Sleep mode is similar to the Pulse mode; SimplyGo detects when the user begins to take a breath and then delivers a pulsed volume of oxygen determined by the setting number. The Sleep mode differs from Pulse mode in that it has a more sensitive triggering level and delivers a softer, more comfortable pulse for sleeping. If no breath is detected for a period of time, the system automatically delivers a continuous flow of oxygen at a rate consistent with the last used Continuous Flow mode setting. 3. Press down on the PUSH button located at the top of the handle. Then pull the handle upward to extend the cart arm to the desired height. 4. Attach the accessory bag around the cart handle using the bag s elastic strap.

Philips Healthcare is part of Royal Philips Electronics How to reach us www.philips.com/healthcare healthcare@philips.com Asia +49 7031 463 2254 Europe, Middle East, Africa +49 7031 463 2254 Latin America +55 11 2125 0744 Philips Respironics 1010 Murry Ridge Lane Murrysville, PA 15668 Customer Service +1 724 387 4000 800 345 6443 (toll free, US only) Philips Respironics International Headquarters +33 1 47 28 30 82 www.philips.com/respironics North America +1 425 487 7000 800 285 5585 (toll free, US only) Respironics and SimplyGo are trademarks of Respironics, Inc. and its affiliates. All rights reserved. Please visit www.philips.com/simplygo 2011 Koninklijke Philips Electronics N.V. All rights are reserved. Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Hoech WMB 11/21/11 MCI 4104502 PN 1094881