Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information



Similar documents
Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM9 10(24VDC) Article No.:

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Technicaldata General

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Three-phase monitoring relay CM-PFE

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Catalog. Modular DIN rail components Installation contactors

Bimetallic Overload Relay Specifications

Technical catalogue. Modular DIN rail components Installation contactors

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

48 SERIES Relay interface modules 10 A

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

RM4TG20 three-phase network control relay RM4-T - range V

Pluggable interface relays CR-P Pcb relays

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Safety technique. Emergency stop module BO 5988 safemaster

49 Series - Relay interface modules A. Features

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Relés e Contatores de Estado Sólido SIRIUS

Analog signal converters CC-E I/I Current / current isolators

38 Series - Relay interface modules A

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Manual motor starter MS116

38 Series - Relay interface modules A

E-STOP relays, safety gate monitors

R.C.C.B. s two-pole LEXIC

Thermistor motor protection

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

D-Line Contactors, Overload Relays and Accessories

Switching Devices Contactors and Contactor Assemblies Special Applications

Quick Connect. quick - simple - efficient.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PSR The compact range Description

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Contact expansion modules

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PHOENIX CONTACT Features

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

MasterINTERFACE 39 Series - Relay interface modules

Digital input modules

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

MasterINTERFACE 39 Series - Relay interface modules

Thermal-Magnetic Circuit Breaker M1-..

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Phone: Fax: Web: info@clrwtr.com

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Manual Motor Starter MS 116 up to 16 A Technical Data

HERZ-Thermal Actuators

5SV Residual Current Protective Devices

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

CQM1-SF200/CS1W-SF200

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Contact expander modules

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Bulletin 150 SMC Flex Smart Motor Controller Specifications

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

EMR measuring and monitoring relays

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

SKR - industry relay

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

80 Series - Modular timers 16 A. Features

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Actuator-Sensor-Interface

Electric Rotary Actuator - On/Off or programmable control actuator

Series 8146/5-V37 and Series 8150/5-V37

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Plug and Socket Devices CES 63 A Series 8579

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Transcription:

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC 3 380 V 400 V I e A 115 Max. rating for three phase motors, 50 60 Hz AC 3 220 V 230 V P kw 37 AC 3 380 V 400 V P kw 55 AC 3 660 V 690 V P kw 90 AC 4 220 V 230 V P kw 17 AC 4 380 V 400 V P kw 28 AC 4 660 V 690 V P kw 43 Conventional free air thermal current I th = I e AC 1 at 60 C Open I th = I e A 130 Contacts Can be combined with auxiliary contact Springloaded terminals on the auxiliary and control circuit terminals DILM150 XHI(V).. DILM1000 XHI(V).. 1

Actuating voltage RAC 240 Contact sequence Notes concerning the product group Accessories 1 Overload relay 278442 2 Suppressor 281199 3 Auxiliary contact module 277376 Further actuating voltages 277379 Accessories 281227 The DC operated contactors have integral suppressor circuits (DILM7 DILM15: Varistor). Contactors DILM115, DILM150 and DILM170 have a built in suppressor circuit. Mirror contact for DILM7 01 to DILM32 01 Contactor contact according to EN 50012 General Standards Lifespan, mechanical IEC/EN 60947, VDE 0660, UL, CSA 2

AC operated Operations 10 6 10 DC operated Operations 10 6 10 Operating frequency, mechanical AC operated Operations/h 3600 DC operated Operations/h 3600 Climatic proofing Ambient temperature Open C 25...60 Enclosed C 25...40 Storage C... 40...+80 Mechanical shock resistance (IEC/EN 60068 2 27) Half sinusoidal shock, 10 ms Main contacts N/O contact g 10 Auxiliary contacts N/O contact g 7 N/C contact g 5 Mechanical shock resistance (IEC/EN 60068 2 27) when tabletop mounted Half sinusoidal shock, 10 ms Main contacts Thickness of material for busbar max. Auxiliary contacts Min. rated current = rated uninterrupted current g 10 g 7 N/C contact g 5 Protection type Protection against direct contact when actuated from front (IEC 536) Weight AC operated kg 2 DC operated kg 2,1 Terminal capacity main cable Damp heat, constant, to IEC 60068 2 78 Damp heat, cyclical, to IEC 60068 2 30 IP00 Flexible with ferrule mm 2 1 (10 95) 2 (10 70) Finger and back of hand proof 3

Stranded mm 2 1 (16 95) 2 (16 70) Solid or stranded AWG 8...3/0 Flat conductor Main cable connection screw/bolt Number of segments width thickness Tightening torque Nm 14 Terminal capacity control circuit cables mm 2 (6 16 0.8) M10 Solid mm 2 1 (0.75 4) 2 (0.75 4) Flexible with ferrule mm 2 1 (0.75 2.5) 2 (0.75 2.5) Solid or stranded AWG 18 14 Control circuit cable connection screw/bolt Tightening torque Nm 1.2 Tool Main cable Hexagon socket head spanner SW mm 5 Control circuit cables Pozidriv screwdriver Size 2 Standard screwdriver mm Terminal capacity control circuit cables M3.5 0.8 5.5 1 6 Solid mm 2 1 (0.75 2.5) 2 (0.75 2.5) Flexible mm 2 1 (0.75 2.5) 2 (0.75 2.5) Flexible with ferrule mm 2 1 (0.75 1.5) 2 (0.75 1.5) Solid or stranded AWG 18 14 Tool Stripping length mm 10 Screwdriver blade width mm 3,5 Main conducting paths Rated impulse withstand voltage U imp V AC 8000 Overvoltage category/pollution degree III/3 4

Rated insulation voltage U i V AC 1000 Rated operational voltage U e V AC 1000 Safe isolation to VDE 0106 Part 101 and Part 101/A1 between coil and contacts V AC 690 between the contacts V AC 690 Making capacity (p.f. to IEC/EN 60947) Breaking capacity Up to 690 V A 1610 220/230 V A 1150 380/400 V A 1150 500 V A 1150 660/690 V A 1100 Short circuit rating Short circuit protection maximum fuse Type 2 coordination 400 V gg/gl 500 V A 250 690 V gg/gl 690 V A 250 Type 1 coordination 400 V gg/gl 500 V A 250 690 V gg/gl 690 V A 250 AC AC 1 duty conv. therm. current 3 pole 50 60 Hz open at 40 C I th A 160 at 50 C I th A 142 at 55 C I th A 135 at 60 C I th A 130 enclosed I th A 115 Conventional free air thermal current, 1 pole open I th A 325 enclosed I th A 285 AC 3 duty Rated operational current AC 3 open, 50 60 Hz, 3 pole 5

220/230 V I e A 115 240 V I e A 115 380/400 V I e A 115 415 V I e A 115 440V I e A 115 500 V I e A 115 660/690 V I e A 93 Motor rating 220/230 V P kw 37 240V P kw 40 380/400 V P kw 55 415 V P kw 70 440 V P kw 75 500 V P kw 85 660/690 V P kw 90 AC 4 duty Rated operational current AC 4 open, 50 60 Hz, 3 pole 220/230 V I e A 55 240 V I e A 55 380/400 V I e A 55 415 V I e A 55 440 V I e A 55 500 V I e A 55 660/690 V I e A 45 Motor rating 220/230 V P kw 17 240 V P kw 19 380/400 V P kw 28 415 V P kw 33 440 V P kw 35 500 V P kw 40 660/690 V P kw 43 DC of three phase capacitors open DC 1 operation 60 V I e A 160 110 V I e A 160 220 V I e A 90 6

440 V I e A 4,5 DC 3 operation 60 V I e A 160 110 V I e A 160 220 V I e A 40 440 V I e A 1 DC 5 operation 60 V I e A 160 110 V I e A 160 220 V I e A 40 440 V I e A 1 Current heat loss (3 pole) Current heat loss at I th W 20,3 Current heat loss at I e to AC 3/400 V W 15,9 Impedance per pole m 0,4 Magnet systems Voltage tolerance AC operated Pick up U c 0,8...1,15 Drop out voltage AC operated Drop out U c 0,25...0,6 DC operated Pick up U c 0,7...1,2 DC operated Drop out U c 0,15...0,6 Power consumption of the coil in a cold state and 1.0 U c 50 Hz Pick up VA 180 50 Hz Sealing VA 3,1 50 Hz Sealing W 2,1 60 Hz Pick up VA 170 60 Hz Sealing VA 3,1 60 Hz Sealing W 2,1 50/60 Hz Pick up VA 170 170 50/60 Hz Sealing VA 3,1 3,1 50/60 Hz Sealing W 2,1 2,1 DC operated Pick up W 149 DC operated Sealing W 2.1 Duty factor % DF 100 Switching times at 100 % U c (approximate values) 7

Main contacts AC operated Closing delay ms 28...33 Opening delay ms 35...41 DC operated Closing delay ms 35 Opening delay ms 30 Arcing time ms 15 Permissible residual current with actuation of A1 A2 by the electronics (with 0 signal). Electromagnetic compatibility (EMC) Emitted interference Interference immunity Notes Notes Mounting position, AC and DC operated ma 1 to EN 60947 1 to EN 60947 1 The following applies to magnet systems, voltage tolerance, pickup voltage DC operated DILM17 DILM32: RDC 24 (Umin 24 V DC/Umax 27 V DC) RDC 60 (Umin 48 V DC/Umax 60 V DC) RDC 130 (Umin 110 V DC/Umax 130 V DC) RDC 240 (Umin 200 V DC/Umax 240 V DC) Example: Uc = 0.7 x Umin 1.2 x Umax Uc = 0.7 x 24 V 1.2 x 27 V DC With voltage tolerance and DC operated power consumption the following applies: At least smoothed double pulse bridge rectification or a three phase current rectifier is necessary 8

Dimensions Dimensions 9

distance at side to earthed parts: 10 mm Basic unit with auxiliary contact module Characteristic curve 10

Squirrel cage motor Operating characteristics Starting:from rest Stopping:after attaining full running speed Electrical characteristics Make: up to 6 rated motor current Break: up to 1 rated motor current Utilization category 100 % AC 3 Typical applications Compressors Lifts Mixers Pumps Escalators Agitators Fans Conveyor belts Centrifuges Hinged flaps Bucket elevators Air conditioning system General drives in manufacturing and processing machines Characteristic curve 11

Extreme switching duty Squirrel cage motor Operating characteristics Inching, plugging, reversing Electrical characteristics Make: up to 6 rated motor current Break: up to 6 rated motor current Utilization category 100 % AC 4 Typical applications Printing presses Wire drawing machines Centrifuges Special drives for manufacturing and processing machines Moeller GmbH, Hein Moeller Str. 7 11, D 53115 Bonn E Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2006 by Moeller GmbH. HPL C2007G V2.1 12