CARDIOVIT AT-102. Ready for networking with XML output. Get high performance without spending a fortune!



Similar documents
SEMA-200 Data Management Solution Comprehensive management and archiving of your diagnostic data

CARDIOVIT AT lead display. The high-performance, multifunctional ECG wizard that meets highest demands and offers excellent value for money!

Make your practice more efficient in a heartbeat.

THE BEST OF ITS CLASS!

SEMA3. Data management of the future, tailored to your needs

Spirodoc. One Touch Laboratory for respiratory analysis two functional modes: doctor and patient. Spirometer with Touch Screen display

THE BEST OF ITS CLASS!

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

Philips PageWriter Touch ECG System

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

EC-12R EC-12RM EC-12R/S EC-12SResting and Stress ECG Family. Technical specification

Company Profile & product presentation.

ECG Holter Monitoring System MT-101 / MT-200 / MT-210

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

FREJA 300 Relay Testing System

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Quick Connect. quick - simple - efficient.

Twenty years of innovative solutions in Spirometry, Oximetry, Telemedicine

LT-82 Stationary IR Transmitter

Electronic Control Devices The European Product Catalogue 2007

Industrial Balances PREMIUM Series 490 IBK/ITK/ISK

MIR Software Comparison Table. Multilanguage (18 Languages)

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Make your practice more efficient in a heartbeat.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

MAGTROL. DSP6001 High-Speed Programmable Dynamometer Controller. DSP6001 Data Sheet FEATURES APPLICATIONS MOTOR TESTING SOFTWARE DESCRIPTION

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Simpler on the outside. Smarter on the inside.

AT-1 / AT-1smartprint ECG unit

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Handheld portable appliance testers

Temperature & Humidity SMS Alert Controller

1. SAFETY INFORMATION

TORKEL 820 Battery Load Unit

Current Monitoring Kit

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Innovation in Spirometry Oximetry Telemedicine

GE Healthcare. The new MAC * 800

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

INVITATION FOR QUOTATIONS FOR SUPPLY OF EQUIPMENT THIS INVITATION DULY SIGNED ON ALL PAGES SHOULD BE ATTACHED WITH THE QUOTE

D Next-generation LED phototherapy NanoBlu 500

AT Channel ECG Recorder

Current Monitoring Kit QUICK START GUIDE

Frequency selective monitoring and logging of environmental electromagnetic fields

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

touchecg Reference Markets your profession, our mission

AMTRON E-30 Compact heat and cooling meter

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Hand-held thermometer Model CTH7000

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Dash 18X / Dash 18 Data Acquisition Recorder

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

J TB/TW Temperature limiter, temperature monitor

DC Electronic Loads 8500 series

Poor quality welds Machine downtime High maintenance costs Lost revenue

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

SEMA/SDS/MT Software API

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

AT-101. AT Channel ECG Unit. User Guide. Art.-no.: Rev.: c * *

Voltage Regulator SPAU 341 C. Product Guide

Online Infrared Flue Gas Analyzer Gasboard 3000

MANUAL PC1000R

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PIEZOMETER AIRFLOW MEASURING RING

Frequency Converter Fv

Duct Humidity Transmitter

NETWORK ENABLED EQUIPMENT MONITOR

EasyOne Technical Manual

BW-500 BED WEIGHER USER MANUAL

Digital Single Axis Controller

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

Disturbance Recoder SPCR 8C27. Product Guide

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial

SOLAR I-V Rel /07/10

Type-D EEG System for Regular EEG Clinic

GeoMax GNSS Zenith10 & Zenith20 Series

R&S ZNC Vector Network Analyzer Specifications

is then retained absolutely without interruption.

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

SMS GSM Alarm Messenger

DMX2PWM 9 Channel Dimmer Setup Manual

SNMP Web Management. User s Manual For SNMP Web Card/Box

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

CYMAQ Marking System AS200 + DS7050 N-14

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Integrating Sound Level Meter and Datalogger

Transcription:

CARDIOVIT AT-102 Ready for networking with XML output Get high performance without spending a fortune! T h e A r t o f D i a g n o s t i c s

CARDIOVIT AT-102 has it all! The most important Cardiopulmonary Function Tests are combined in one single device: Resting ECG Exercise ECG Spirometry Performance: Intuitive, easy use with direct function keys 12-channel Resting ECG Measurements Interpretation (optional) Serial data transfer to PC for storage of both Resting ECG and Spirometry recordings XML data transfer for Resting ECG to PC or Information Systems via Ethernet or modem interfaces (optional) A4-formated (8.5 x11 inches) printouts on internal or external printer Basic Exercise test capability (optional) Possibility for external monitor connection (optional) Capable of data transfer to the SCHILLER Data Management System SEMA-200 Resting ECG: Operating elements: Integrated 3-channel monitor Alphanumeric keyboard Direct keys for the most important functions Easy Print: Integrated high-resolution A4 (8.5 x11 inches) thermal printer, subsequent printout on thermoreactive paper possible Interface for external printer for A4 (8.5 x11 inches) printouts on regular paper Internal memory for up to 40 records Interface for data-transmission

External monitor LCD with direct function keys Exercise ECG: Interface: RS-232 port for peripheral devices such as treadmills, bicycles etc. Protocols: For exercise ECG, several stand-ard protocols are available for bicycle and treadmill ergometers; the user can either select a standard protocol from a table or define a new protocol J-point settings: J+20, +40, +60, +80 ms; default: +60 ms Display on the LCD: 3 leads can be selected via direct keys Heart rate ST slope and amplitude (in mv/mv/s) of a lead (the lead can be selected in the set-up; default is V5) Stage, time, and current load Blood pressure (Blood pressure measurement: Automatic if a bicycle contains an interface for the blood pressure transfer or manual) Printouts: Online printout: 6 leads on the internal thermal printer 10-sec. printout: A 10-sec. printout can be initiated at any time on the internal thermal printer Two print formats are available for stage printouts on the internal thermal printer: 2*6 25 mm/s and 50 mm/s, 1 page 4*3 + 1 rhythm, 25 mm/s (50 mm/s), 1 page Final report: All test data is listed in a tabular form

SCHILLER extensible Connectivity Ethernet and modem interfaces for XML output (optional) XML Data Transmission (optional) The AT-102 is available with the internal SCHILLER Communication Module (SCM), which transmits Resting ECG data on XML format to a PC or Information Systems via: Ethernet interface; or Built-in analogue modem (optional) This enables the AT-102 to be an integrated part of a larger systems solution Secure transmission of patient data via the Internet is possible using 1024-bit strong encryption Equipped with the add-on SCM Server, the SCHILLER Data Management System SEMA-200 can receive the XML output from the SCHILLER Communication Module Spirometry view in the SCHILLER Data Management System SEMA-200 Spirometry: Unique SP-250 with disposable sensor to reduce the risk of contamination SP-260 with reusable sensor Simple and fast calibration Memory for up to 40 records Inspiratory and exspiratory test; pre and post medication tests Selectable predicted value tables Real-time curves and measurement information on the large screen

Technical Data CARDIOVIT AT-102: EKG-Ausdruck System: Dimensions: 400 x 330 x 101 mm, approx. 5 kg Built-in monitor: 120 x 90 mm effective display area, 320 x 240 dots resolution On-screen status indicators: Battery status, date, time, power source Control panel and keyboard: User-friendly, alphanumeric keyboard, LED indicator and LC display Power supply requirements: 220 240 V (nominal), 50/60 Hz; 110 115 V (nominal), 50/60 Hz; stand-alone operation with built-in rechargeable battery; LED indicator for mains operation, integrated power supply unit Battery capacity: 4 hours of normal use (approx. 300 automatic ECG printouts or 100 spirometry records) Power consumption: Max. 30 VA Line frequency filter: Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by means of adaptive digital filtering (SCHILLER Powerline Filter SPF) Frequency range of digital recording system: 0 Hz 150 Hz (IEC/AHA) Chart paper: Thermo-reactive, Z-folded, 210 mm wide (A4, 8.5 x11 inches) Printing process: High-resolution thermal head printer,8 dots/mm (amplitude axis), 40 dots/mm (time axis) @ 25 mm/s Interfaces: RS-232 interface to connect spirometry sensor, data transmission to PC (SEMA-200) and external modem connection; parallel port for external printer; optional Ethernet interface and optional internal modem for XML data transmission Memory: Possibility to save up to 40 Resting ECG or Spirometry measurements Environmental conditions: Temperature, operating: 10 to 40 C Temperature, storage: -10 to 50 C Relative humidity: 25 to 95% (no condensation) Pressure during operation: 700 to 1060 hpa Safety Standards: Safety Standards: IEC/EN 60601-1; UL 60601-1; C22.2 No. 601.1-M90; IEC/EN 60601-2-25; IEC/EN 60601-1-2 (EMC) Protection Class: I according to IEC/EN 60601-1 (with internal power supply) Applied Part: CF according IEC/EN 60601-1 Conformity: according Directive 93/42/EEC (Medical Devices) Classification: IIa according Directive 93/92/EEC Data record: Patient data (name, age, height, weight, BP), user ID Listing of all ECG recording conditions (date, time, filter) Measurement program (M): ECG measurements results (intervals, amplitudes, electrical axes), average complexes with measurement reference markings Interpretation (C) with adult and pediatric guidance Recording track: 6/12-channel presentation, optimal positioning on a width of 200 mm, automatic baseline adjustment Filter: Myogram filter (muscle tremor filter): 25 Hz or 35 Hz, can be switched on/off (SCHILLER Baseline Stabilizer SBS, SCHILLER Smoothing Filter SSF) ECG amplifier: Simultaneous recording of all 9 active electrode signals (= 12 leads) Sampling frequency: 1000 Hz Pacemaker detection: 2 mv/ 0,1 ms Technical Data for Spirometry (Option): Measured values: FVC: FVC, FEV0.5,FEV1.0, FEV3.0, FEV0.5/FVC, FEV1,0/FVC, FEV3.0/FVC, FEF0.2-1.2, FEF25-75%, FEF75-85%, PEF, FEF25%, FEF50%, FEF75%, FIVC, FIV1.0, FIV1.0/FIVC,FIV1.0/FVC,PIF,FIF50%, FMFT SVC: SVC, ERV, IRV,TV MVV: MVV, RR,TV Presentation possibilities (printout and screen): Flow/volume graph Volume/time graph Table of measured values Realtime flow curve Data record: Patient data (name, age, height, weight), user ID Registration conditions (date, time, date of last calibration) Flow/volume graph and/or volume/time graph Table of measured values with PREDICTED/ACTUAL/ DIFFERENTIAL values Diagnosis guidance Memory for more than 60 ECGs or spirometry records Prediction equation: Adults: ECCS,Austria, Crapo, Morris, Knudson, Knudson76, Polgar, Berglund, Finland, India, Composite Children: Quanjer & Tammeling,Austria, India, Knudson, Knudson76, Polgar Extrapolated predicted values Comparison of PRE/POST medication is possible Standards Compliance: ATS, OSHA, NIOSH SPIROVIT SP-250 Pneumotach Flowsensor for pulmonary function testing with disposable mouthpiece: Dimensions of SP-250: 118 x 36 x 28 mm, approx. 120 g; 4.6 x 1.4 x 1.1 in., approx. 0.26 Ibs Measuring method: Pneumotachometer Measuring accuracy: According ATS < 3% Flow impedance: < 0.2 mbar*s/l at 12 l/s SPIROVIT SP-260 Pneumotach Flowsensor for pulmonary function testing with reusable mouthpiece: Dimensions of SP-260: 125 x 36 x 28 mm, approx. 160 g; 4.9 x 1.4 x 1.1 in., approx. 0.34 Ibs Measuring method, Measuring accuracy, Flow impedance same as SP-250 Scope of delivery: 1 pneumotach sensor; choice of SP-250 disposable (P/N 2.100022) or SP-260 reusable sensor (P/N 2.100551) Accessories: 2 noseclips and either 1 pack of disposable plastic mouthpieces for SP-250 (P/N 2.100077) or 1 pack of disposable filters for SP-260 (P/N 2.100123) 1 operating manual Scope of delivery for CARDIOVIT AT-102 Standard: CARDIOVIT AT-102 Resting ECG with 12 simultaneous leads, pacemaker detection, automatic ECG measurement Accessories: 1 10-lead patient cable 1 set of electrodes or disposable electrodes 1 power cable 1 pack chart paper Operating manual Software options: Computer-aided ECG interpretation for pediatric and adult ECGs (C) Basic exercise test SEMA-200 PC software to save, validate and archieve ECG and spirometry data on PC Hardware options: Equipment trolley Spirometry sensor SP-250 or SP-260 Calibration syringe Vacuum electrode system VAC-100 Spirometrie-Ausdruck External printer External monitor connection Internal SCHILLER Communication Module with optional built-in analogue modem Technical Data are subjet to change without notice. Technical Data for ECG: Patient input circuit: Fully floating and isolated, defibrillationprotected (only with original SCHILLER patient cable) Monitor display: 3-channel display of the selected leads 25, 50 mm/s 5, 10, 20 mm/mv Filter status (on/off) Insufficient electrode contact Heart Frequency, HF mm/mv, mm/s Leads: 12 simultaneous leads: Standard / Cabrera Chart printout speed: 5/10/25/50 mm/s (manual print) Sensitivities: 5/10/20 mm/mv, either automatically adjusted or manually selected Automatic lead programs: 6/12-channel presentations of 12 simultaneously recorded standard leads on one or more A4 (8.5 x 11 inches) pages Numerous printout formats can be selected

ASIA SCHILLER Asia-Pacific 10 C Jalan SS 3/33 Taman Universiti 47300 Petaling Jaya Selangor, Malaysia Phone +603 7877 5336 Fax +603 7877 5744 schiller@top.net.my AUSTRIA SCHILLER Handelsges. m.b.h. Kampmüllerweg 24 A-4040 Linz Phone +43 732 70 99 Fax +43 732 757 000 sales@schiller.at C.I.S. & Russia SCHILLER AG Moscow Representative Office Office 414,1-st Yamskogo Polya street 15 125124 Moscow, Russia Phone/Fax: +7 (095) 970 11 33 +7 (095) 956 29 10 mail@schiller-ag.com www.schiller-cis.com FRANCE SCHILLER MEDICAL SAS 4, rue Louis Pasteur F-67162 Wissembourg Phone +33 3 88 63 36 00 Fax +33 3 88 94 12 82 info@schiller.fr GERMANY SCHILLER Medizintechnik GmbH Rudolf-Diesel-Strasse 14 D-85521 Ottobrunn Phone +49 89 629 9810 Fax +49 89 609 5090 info@schillermed.de INDIA SCHILLER Healthcare India Pvt. Ltd. D.C. Silk Mills Compound A Wing,1st Floor 5, Chunawala Estate, Kondivitta Lane Andheri-Kurla Road, Andheri (E) Mumbai 400 059, India Phone +91 22 826 35 20 Fax +91 22 826 35 25 schiller@vsnl.com SPAIN SCHILLER ESPAÑA, S.A. Avenida Baviera,12-14 Posterior E-28028 Madrid Phone +34 91 713 01 76 Fax +34 91 355 79 33 schiller@schiller-es.com SWITZERLAND SCHILLER-Reomed AG Riedstrasse 14 CH-8953 Dietikon Phone +411 744 30 00 Fax +411 740 37 10 sales@schiller-reomed.ch Part No.: 2.500374 11/04 TURKEY SCHILLER TÜRKIYE Halil Rifat Pasa Mah. Darülaceze Cadd. Perpa Ticaret Merkezi B/Blok No:41 K:2 Okmeydani-Sisli Istanbul Turkey Phone +90 212 210 86 81 (pbx) Fax +90 212 210 86 84 sales@schiller-turkiye.com USA SCHILLER America Inc. 11300 NW 41st Street Miami, Florida 33178, USA Phone +1 786 845 06 20 Fax +1 786 845 06 02 sales@schilleramerica.com Your specialist: T h e A r t o f D i a g n o s t i c s Headquarters: SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, Phone: +41 41 766 42 42, Fax: +41 41 761 08 80, sales@schiller.ch