Factors Influencing Multiplex Real-Time PCR



Similar documents
Real-time PCR: Understanding C t

Essentials of Real Time PCR. About Sequence Detection Chemistries

2.500 Threshold e Threshold. Exponential phase. Cycle Number

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Introduction To Real Time Quantitative PCR (qpcr)

Real-Time PCR Vs. Traditional PCR

QPCR Applications using Stratagene s Mx Real-Time PCR Platform

Highly specific and sensitive quantitation

TaqMan Fast Advanced Master Mix. Protocol

360 Master Mix. , and a supplementary 360 GC Enhancer.

Gene Expression Assays

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

The AB7900Fast and Principles of Real Time PCR

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

User Bulletin #2 ABI PRISM 7700 Sequence Detection System

Validating Microarray Data Using RT 2 Real-Time PCR Products

Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

Real time and Quantitative (RTAQ) PCR. so I have an outlier and I want to see if it really is changed

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Real-time quantitative RT -PCR (Taqman)

StepOne and StepOnePlus Real-Time PCR Systems

Stratagene QPCR Mouse Reference Total RNA

Path-ID Multiplex One-Step RT-PCR Kit

Power SYBR Green PCR Master Mix and Power SYBR Green RT-PCR Reagents Kit

Gene Expression Assay Performance Guaranteed With the TaqMan Assays QPCR Guarantee Program

TaqMan Multiplex PCR Optimization For optimization of Multiplex PCR using 7500/7500 Fast, ViiA 7, and QuantStudio Real-Time PCR Systems

Quantitative Real Time PCR Protocol. Stack Lab

Quantifiler HP and Trio DNA Quantification Kits User Guide

Quantification of Mycobacterium Tuberculosis. 150 tests

RealStar HBV PCR Kit /2012

Quantitative PCR Systems

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

Reagent Guide. Applied Biosystems StepOne and StepOnePlus Real-Time PCR Systems

Getting Started Guide

SYBR Green PCR Master Mix and SYBR Green RT-PCR Reagents Kit

Human Herpes Virus 4 (Epstein Barr)

Fluorescent dyes for use with the

Co Extra (GM and non GM supply chains: Their CO EXistence and TRAceability) Outcomes of Co Extra

QuantiFast Multiplex PCR Handbook

Real-time PCR handbook

Mir-X mirna First-Strand Synthesis Kit User Manual

Pitfalls in qpcr. Primer and probe design and synthesis. Mary Span Eurogentec S.A.

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

Absolute Quantification Getting Started Guide

BacReady TM Multiplex PCR System

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

Introduction to Quantitative PCR

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Quantifiler Kits Quantifiler Human DNA Quantification Kit and Quantifiler Y Human Male DNA Quantification Kit

Applications Guide. Real-Time PCR Applications Guide

SYBR Green Realtime PCR Master Mix -Plus-

QuantStudio 3D AnalysisSuite Software

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

Methods and Application Guide. Introduction to Quantitative PCR

GenScript BloodReady TM Multiplex PCR System

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Sequencing Library qpcr Quantification Guide

Absolute Quantitation Using Standard Curve Getting Started Guide

TaqMan Mutation Detection Assay

Application Guide... 2

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

CopyCaller Software. User Guide

Relative Quantification Applied Biosystems 7300/7500 Real Time PCR System

Methylation Analysis Using Methylation-Sensitive HRM and DNA Sequencing

Lyme Disease. RecA gene. 150 tests. Quantification of Lyme Disease genomes. Advanced kit handbook HB

Genomic DNA detection assay

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

Using TaqMan Endogenous Control Assays to select an endogenous control for experimental studies

Real-time qpcr Assay Design Software

mircute mirna qpcr Detection Kit (SYBR Green)

Absolute Quantifi cation of Gene Expression using SYBR Green in the Eco Real-Time PCR System

Quantification of Hepatitis B Virus. Core Protein Region. 150 tests

PATHOGEN DETECTION SYSTEMS BY REAL TIME PCR. Results Interpretation Guide

Optimizing and Analyzing Real-Time Assays on the SmartCycler II System

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

DyNAmo cdna Synthesis Kit for qrt-pcr

Lyme Disease RecA gene. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere tests. Primerdesign Ltd.

Beginner s Guide to Real-Time PCR

Application Note. Biotechnology Explorer Crime Scene Investigator PCR Basics. Kit: A Real-Time PCR Extension

CompleteⅡ 1st strand cdna Synthesis Kit

Guide to using the Bio Rad CFX96 Real Time PCR Machine

HBV Quantitative Real Time PCR Kit

Real-Time Quantitative PCR Instruments and Consumables

TaqMan Gene Expression Assays. Protocol

Quantification of Propionibacterium acnes. Standard kit 150 tests

Plexor Systems Instrument Setup and Data Analysis for the Applied Biosystems 7300 and 7500 Real-Time PCR Systems

TITRATION OF raav (VG) USING QUANTITATIVE REAL TIME PCR

TaqMan Copy Number Assays. Protocol

REAL TIME PCR USING SYBR GREEN

Accurate and sensitive mutation detection and quantitation using TaqMan Mutation Detection Assays for disease research

HID Real-Time PCR Analysis Software

PicoMaxx High Fidelity PCR System

ab Hi-Fi cdna Synthesis Kit

StepOne and StepOnePlus Real-Time PCR Systems. Remarkably Simple Systems. Simply Remarkable Results.

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Megaplex Pools For microrna Expression Analysis

The following topics are covered in this user bulletin:

Transcription:

APPLICATION NOTE Multiplex Real-Time PCR Factors Influencing Multiplex Real-Time PCR Introduction Multiplex PCR is the simultaneous amplification of more than one target sequence in a single reaction [1]. Specifically, duplex PCR is the amplification of two target sequences in one reaction, triplex PCR is the amplification of three targets, and so on. Multiplex real-time PCR is possible using TaqMan probe based assays, in which each assay has a specific probe labeled with a unique fluorescent dye, resulting in different observed colors for each assay. Real-time PCR instruments can discriminate between the different dyes. The signal from each dye is used to separately quantitate the amount of each target. PCR, which has several advantages over individual reactions (Table 1), is routinely performed in many research labs. However, setting up reliable multiplex PCR can be a challenge as the results need to be validated, and in some situations, optimization of the reaction conditions may be necessary. Challenges Involved in Multiplex Real-Time PCR Multiplex assays must always be validated and often require optimization. Depending on the targets being analyzed and the samples being used, reaction optimization and validation could range from a simple, straightforward exercise to a costly, timeconsuming endeavor. The cost and time involved increase with the number of targets to be investigated. It is absolutely essential that results obtained from multiplex reactions are verified to confirm that the same results would be obtained if the reactions were performed individually. Where sample amounts are extremely limited, Table 1. Key Benefits of Multiplexing. Benefit Cost savings Preservation of limited samples Reliability (e.g., reduced effect of pipetting errors) preamplification using the TaqMan PreAmp Master Mix is a suitable option, particularly if many targets need to be analyzed. This application note outlines the optimization and validation of duplex PCR and provides recommendations for multiplex reactions with a greater number of targets. Primer Design for PCR Applied Biosystems Primer Express Software is recommended for real-time PCR primer and probe design. Primer Express Software is a flexible, easy-to-use program that requires minimal optimization and has been developed specifically for use with Applied Biosystems real-time PCR instruments. The software is capable of automated or manual primer/probe design. When designing and choosing multiple PCR primers for multiplex assays, it is important to consider the following: A primer should not contain bases that are complementary to other bases within the primer (self-complementary), nor should it have complementarity to other primers. Complementarity at the 3' ends should Advantages of Multiplexing Fewer reactions are run, conserving expensive reagents (dntps, enzymes, endogenous controls, etc.) Where sample amount is limited, multiplexing allows more targets to be analyzed using a single aliquot of sample material Data quality can be improved because the target of interest is normalized to the endogenous control within the same aliquot of the sample especially be avoided to minimize the formation of artifact products, often called primer-dimers or primer-oligomers. Tip: Use the free AutoDimer software to check your primers. This tool can be accessed at www.cstl.nist.gov/strbase/autodimerhomepage/ AutoDimerProgramHomepage.htm. A 40 60% GC content is recommended for all primers, avoiding long stretches of any one base. Also, primers should not hybridize to regions of secondary structure within the target as these tend to have a higher melting point than the primer. The primer T m should be the same for all primers used in the multiplex reaction. The length of the amplicon should be 50 150 bp for optimal PCR efficiency. Primers that generate a longer amplicon may result in poor amplification efficiency. If longer amplicons cannot be avoided, it may be necessary to optimize the thermal cycling protocol and reaction components. The primer should be specific for the target. Perform a BLAST search at www.ncbi.nlm.nih.gov/blast.

Optimization of a Reaction Before optimization of a duplex assay, consider the following: 1. What are the relative expression levels of the targets that will be detected? 2. What target will be used as an endogenous control? 3. What is the magnitude of the fold differences that are expected? Since both assays are amplified in the same tube, they compete for the same reagents (dntps and polymerase). It is important that this competition be minimized. The two assays can also inhibit each other through interactions among the four primers, the two probes, the targets or amplicons, or any combination of these. The goal of multiplex PCR is to accurately quantitate the amount of each target present, without interference from competition or inhibition between assays. Relative Expression Levels of the Targets To Be ed There are three possible scenarios for the relative expression levels of the two targets: 1. One of the targets typically the endogenous control is always expressed at much higher levels than the other. 2. The relative expression levels are about the same. 3. Either target can be more abundant than the other in any given sample. Case 1 One target is always more abundant When duplex PCR is performed on a sample in which one target is more abundant, the greater starting quantity of the more abundant target causes the assay for that target to perform better than the other from the start, using up the dntps in the reaction, and leaving little for the other assay. This problem is overcome by limiting the amount of primer for the more abundantly expressed target. As a result, the primers for that assay are used up rapidly, leading the reaction to plateau early and leaving sufficient dntps for the amplification of the less abundant target. Case 2 Targets are of similar abundance Generally, in this situation, neither assay needs to be primer-limited. The assays can simply be run as single or duplex reactions and validated as described below. However, if validation fails, it may be necessary to primer-limit one or both assays to enable the duplexing to perform better. Case 3 Either target may be more abundant If either target could be more abundant than the other, depending on the samples being investigated, then both assays need to be primer-limited. Primer-Limiting Assays Applied Biosystems provides common endogenous control assays for human, mouse, and rat that are available primerlimited and labeled with the VIC dye, which is recommended for multiplexing with FAM dye. These assays can be located at www.appliedbiosystems.com by searching for PDAR (Pre-Developed Assay Reagents). If the required endogenous control target is available, you can begin validating your duplex PCR. However, if it is not, you must primer-limit the assay yourself. The goal of primer-limiting the assay is to find the primer concentration that gives the lowest (earliest) possible value for the more abundant target without distorting the value of the less abundant target. Limiting the primer concentration for the more abundant target has the effect of lowering its ΔRn (Figure 1); however, the should remain unchanged under primerlimited conditions. A sample should be assayed using decreasing amounts of primer in order to determine the optimal primer concentration for each assay. 1.000 A: 100 nm B: 75 nm C: 50 nm D: 25 nm E: 10 nm A Rn (fluorescence) B C D E 1.000 E-1 Increasing Threshold Cycle Figure 1. Determining Primer Limit for 18S rrna. Total RNA (100 ng; Stratagene) was reverse transcribed with the Applied Biosystems High Capacity RNA-to-cDNA Kit and amplified using the indicated primer concentrations in 10 µl reactions. The same is obtained at primer concentrations of 100 and 75 nm, with a lower ΔRn observed at 75 nm. There is an increase in when primer concentrations of 50, 25, and 10 nm are used. As was unchanged at a primer concentration of 75 nm, this was selected as the minimum concentration for amplifying 18S rrna in a duplex reaction. Amplification reactions were performed on an Applied Biosystems 7900HT Fast Real-Time PCR System.

Validating Reactions Make a dilution series of the sample containing seven 10-fold dilutions in triplicate. Run each assay individually and in duplex using each dilution in the series. The setup is summarized in Table 2. Table 2. Summary of Experiment Setup for Validating Reactions. Assay Reactions Number of Wells/Tubes Target A or endogenous control (primer-limited) using sample of known concentration Triplicate simplex reactions using 7 points of a 10-fold dilution series 21 Target B (same sample with known concentration) Triplicate simplex reactions using 7 points of a 10-fold dilution series 21 : Target A (primer-limited) and Target B Triplicate duplex reactions using 7 points of a 10-fold dilution series 21 Representative samples: Target A Triplicate simplex reactions 3 Representative samples: Target B Triplicate simplex reactions 3 Representative samples (Targets A and B, duplex) Triplicate duplex reactions 3 No-template control (NTC), for each target Triplicate simplex reactions and duplex reactions 9 1. General Guidelines Ensure that the dynamic range of the standard curve is broad enough to encompass most of the experimental samples, bearing in mind that the expression levels of the target(s) of interest may vary widely between samples. 2. Dynamic Range Take a careful look at the standard curve, ensuring that there is a good fit of the line to all the standard points, and that the correlation coefficient (R 2 ) of the line is 0.99 or higher. A lower R 2 value indicates that some of the dilutions (usually the lowest, highest, or both) do not sit on the standard curve. Identify the samples that do not sit on the curve and, using the well inspector, omit them, and reanalyze. Please refer to the document Real-Time PCR: Understanding (Publication 136AP01-01) at www.appliedbioystems.com for guidance on how to evaluate an experiment. 3. Relative Quantities Using the dilution series, calculate the relative abundance of the target in a representative sample. The values obtained using the single reactions need to match those obtained from duplexing. Substantial differences between the numbers indicate that there is significant interference between the two reactions, rendering the duplexing data unreliable. If this occurs, it is recommended that you choose an alternative endogenous control assay or a different assay for your target of interest, or run the samples as single reactions. 4. Precision Multiplexing should eliminate differences in relative expression that occur as a result of pipetting errors. Therefore, a variation greater than 3% indicates that other factors, such as competition or inhibition in the duplex reaction, are contributing to the lack of precision. When small differences in relative expression are being investigated, lower precision may cause these differences to be statistically insignificant and will require more replicates to be run. The value of duplexing is reduced if statistically significant data are obtained by running 3 replicate assays as single reactions but 4 or 5 replicates are required to achieve the same level of statistical significance when the reactions are run in duplex. 5. Standard Deviation Determine the standard deviations of samples assayed as single and duplex reactions. If the standard deviation is higher in the duplex reactions but the differences being measured are small, more replicates may be required in order to obtain statistically significant data. However, this increases the cost and reduces the value of duplexing. In this case, you may find that running assays as single reactions is cheaper, easier, and more convenient than duplexing.

Multiplexing With More Than Two Targets It is also possible to perform multiplex PCR with more than two targets. In fact, there are several Applied Biosystems multiplex assays focused mainly on human identification or pathogen detection applications, which are suitable for use on a range of platforms. A typical multiplex PCR to detect three targets using the Quantifiler Duo DNA Quantification Kit on an Applied Biosystems real-time PCR instrument is shown in Figure 3. The recommendations for performing multiplex PCR with more than two targets are the same as for a standard duplex reaction. It is still important to take into consideration the relative abundance within the samples of each of the targets and, if necessary, to consider primer-limiting one or all of the assays. It is also important to validate the multiplex results using the process described above to ensure that there is no competition for reagents within the reaction. Note that the more targets that are assayed in a multiplex reaction, the more likely it is that there will be competition for reagents and inhibition between assays. Bear the following additional recommendations in mind when you plan an experiment to carry out multiplex reactions for more than two targets: Consider using TaqMan MGB probes rather than the TAMRA probes. TAMRA dye is used as the quencher for the TAMRA probes; however, as TAMRA is a fluorescent dye, there is one less filter available for detection (NED /TAMRA filter). MGB quenchers do not emit fluorescence, making possible the use of additional reporter probes labeled with NED. Consider the spectral properties of each dye (intensity of fluorescence, spectral overlap with other dye) within your reaction and aim for the order of amplification for each experiment you perform. That is, organize the assays such that the internal positive control, or the assay containing NED dye, exhibits the lowest values, followed by the assay containing the FAM, VIC, or Cy 5 dye. Ensure that the internal control assay is primer-limited to prevent it from competing with the true targets for reagents. Rn (fluorescence) 1.000 1.000 E-1 5 10 15 20 25 30 5 10 15 20 25 30 Cycle Cycle A. 18S rrna (VIC /TAMRA ) B. Assay X (FAM /MGB) 35 30 25 20 15 10 Slope: -3.46; R 2 : 0.999 Slope: -3.45; R 2 : 0.999 Figure 2. Validation of a Reaction of 18S rrna and Assay X. Seven points of a 10-fold dilution series of template were analyzed by simplex or duplex real-time PCR for 18S rrna (VIC /TAMRA probe; 75 nm primer concentration) (A and C) and Assay X (FAM /MGB probe; 200 nm primer concentration) (B and D) on the Applied Biosystems 7900HT Real-Time PCR Instrument. The duplex reactions for 18S rrna showed exactly the same efficiency as the single reactions, as shown by the standard curve and R 2 values in C. There is inhibition of Assay X when it is run as a duplex, resulting in higher values and different R 2 values, as seen in B and D. Figure 3. Triplex Real-Time PCR Using the Quantifiler Duo DNA Quantification Kit and an Applied Biosystems Real-Time PCR Instrument. The Quantifiler Duo DNA Quantification Kit contains all the necessary reagents for the amplification, detection, and quantitation of a human-specific DNA target (red lines) and a human male-specific DNA target (blue lines), as well as an internal positive PCR control (green lines). A TaqMan MGB probe labeled with VIC dye is used to detect the amplified human target sequence, a TaqMan MGB probe labeled with FAM dye is used to detect the human male amplified target sequence, and a TaqMan MGB probe labeled with NED dye is used for the internal positive control. 1.000 1.000 E-1 5 15 1 2 3 4 5 6 7 0 1 2 3 Dilution Dilution C. 18S rrna Linear Representation D. Assay X Linear Representation Rn 1 0.1 0.01 20 22 24 26 28 30 Cycle Rn (fluorescence) 31 29 27 25 23 21 19 17 Slope: -3.51; R 2 : 0.998 Slope: -3.35; R 2 : 0.999 32 34 36 38

Table 3. Compatibility and Recommendations for Applied Biosystems Real-Time PCR Instruments. Instrument Number of Filters and Dyes Available Passive Reference Dye * Dyes Available for Multiplexing StepOne 3 ROX FAM VIC StepOnePlus 4 ROX FAM VIC NED 7300 4 ROX FAM VIC NED 7500 5 ROX FAM VIC NED Cy 5 7500 Fast 5 ROX FAM VIC NED Cy 5 7900HT Fast 4 ROX FAM VIC NED * ROX dye is recommended for use as a passive reference. Choice of Reagents The choice of master mix used for multiplex PCR can greatly influence the data obtained. Applied Biosystems Gene Expression Master Mix is designed specifically for use in multiplex reactions (Figure 4). Two synthetic templates, target A and target B, were used to compare the effect of master mixes on duplex PCR. Each reaction comprised a dilution series (1:10) of target A and a fixed concentration of target B, for which the reaction was primer-limited. Gene Expression Master Mix performs better than Universal Master Mix for duplex PCR. The Value of Multiplex PCR Careful consideration must be given to performing multiplex PCR, which may be the ideal approach for high-throughput, routine assays. For such assays, the time and cost associated with validation will be offset by the overall cost savings of running a well-optimized multiplex reaction. Once the decision to multiplex is made, strict attention must be paid to primer design, choice of master mix, and optimizing and validating reactions. Most targets can be analyzed by duplex PCR with careful primer design and appropriate choice of master mix. However, the value in multiplexing higher numbers of targets needs careful assessment. The time and expense required to optimize and validate the multiplex PCR data to ensure they are the same as would have been obtained using single reactions may outweigh the potential benefits of the resulting multiplex design. 40.00 35.00 30.00 25.00 20.00 15.00 10.00 5.00 0.00 UMM simplex UMM duplex UMM IPC y = -3.7249x + 33.748 R 2 = 0.9996 y = -4.6264x + 38.624 R 2 = 0.9818 1 2 3 4 5 6 7 A. PCR Using TaqMan Universal PCR Master Mix. 40 35 30 25 20 15 10 5 0 GEMM simplex GEMM duplex GEXMM IPC y = -3.6993x + 37.899 R 2 = 0.9991 y = -3.691x + 37.922 R 2 = 0.9991 1 2 3 4 5 6 7 B. PCR Using TaqMan Gene Expression Master Mix. Figure 4. Reagent Choice Influences Results Obtained by PCR. Duplicate single and duplex real-time PCR assays were performed on samples containing two synthetic templates, target A and target B, using (A) Applied Biosystems Universal Master Mix or (B) Applied Biosystems Gene Expression Master Mix. A dilution series of target A (lowest dilution: 12 copies) was analyzed with a fixed concentration of target B. The assay for target B was primer-limited. There was excellent correlation between the single and duplex reactions when Gene Expression Master Mix was used. Reference 1. Henegariu O, Heerema NA, Dlouhy SR et al. (1997) Multiplex PCR: Critical parameters and step-by-step protocol. Biotechniques 21:504 511.

ORDERING INFORMATION Description Size Part Number TaqMan Gene Expression Master Mix, 1 Mini-Pack 1 x 1 ml (40 rxns) 4370048 TaqMan Gene Expression Master Mix, 1-Pack 1 x 5 ml (200 rxns) 4369016 TaqMan Gene Expression Master Mix, 5-Pack 5 x 5 ml (1,000 rxns) 4369510 TaqMan Gene Expression Master Mix, 1 Bulk Pack 1 x 50 ml (2,000 rxns) 4370074 TaqMan Gene Expression Master Mix Protocol 1 protocol 4371135 For Research Use Only. Not for use in diagnostic procedures. 2010 Life Technologies Corporation. All rights reserved. Trademarks of Life Technologies Corporation and its affiliated companies: Applied Biosystems, AB Logo, FAM, NED, Primer Express, Quantifiler, StepOne, StepOnePlus, TAMRA, VIC. TaqMan is a registered trademark of Roche Molecular Systems, Inc. Cy is a trademark of GE Healthcare. All other trademarks are the sole property of their respective owners. Printed in the USA. 01/2010 Publication 136AP04-01 O-081742 Headquarters 850 Lincoln Centre Drive Foster City, CA 94404 USA Phone 650.638.5800 Toll Free 800.327.3002 www.appliedbiosystems.com International Sales For our office locations please call the division headquarters or refer to our Web site at www.appliedbiosystems.com/about/offices.cfm