Bulletin 150 SMC Flex Smart Motor Controller Specifications



Similar documents
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

SMC -3 Specifications

38 Series - Relay interface modules A

Electronic overload relay EF65, EF96 and EF146

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 Series - Relay interface modules A

Electronic overload relay EF19 and EF45

SMC FLEX QUICK START BULLETIN 150

MasterINTERFACE 39 Series - Relay interface modules

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

48 SERIES Relay interface modules 10 A

RM4TG20 three-phase network control relay RM4-T - range V

80 Series - Modular timers 16 A. Features

USER MANUAL FOR SERIES B. SMC -Flex BULLETIN 150

MasterINTERFACE 39 Series - Relay interface modules

Selection Guide. SMC -3 and SMC Flex Smart Motor Controllers

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

80 Series - Modular timers 16 A. Features

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Safety technique. Emergency stop module BO 5988 safemaster

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Bimetallic Overload Relay Specifications

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

PSR The compact range Description

Phone: Fax: Web: info@clrwtr.com

49 Series - Relay interface modules A. Features

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Three-phase monitoring relay CM-PFE

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Type: DILM32 10(24V50HZ) Article No.:

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Thermistor motor protection

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Analog signal converters CC-E I/I Current / current isolators

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

Type: DILM9 10(24VDC) Article No.:

Voltage Regulator SPAU 341 C. Product Guide

CompactLogix Power Supplies Specifications

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Energy Management Energy Meter Type EM23 DIN

Relés e Contatores de Estado Sólido SIRIUS

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

32VFD Variable Frequency Drives for Centrifugal Chillers

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Power Supplies 3. SDN-P DIN Rail Series

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

How To Use The Vacon 0 Machinery

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

E-STOP relays, safety gate monitors

Quick Connect. quick - simple - efficient.

Technical catalogue. Modular DIN rail components Installation contactors

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Catalog. Modular DIN rail components Installation contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Redundancy Module QUINT-DIODE/40

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

R.C.C.B. s two-pole LEXIC

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

40 Series - Miniature PCB/Plug-in relays A. Features

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Manual motor starter MS116

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Motor Protection and Monitoring

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

PNOZsigma - Base units

Contact expander modules

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

A project to optimise quality and energy efficiency must include metering

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Transcription:

Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering Alarm Contact Status Indication Auxiliary Contacts Pump Control Braking Control SMB Smart Motor Braking Accu-Stop Slow Speed with Braking Functional Design Specifications Standard squirrel-cage induction motor or a Wye-Delta, six-lead motor. 2- and 3-wire control for a wide variety of applications. Front keypad and backlit LCD display. Parameter values can be downloaded to the SMC-Flex Controller with DriveTools programming software and the Cat. No. 20-COMM DPI communication module. One DPI provided for connection to optional human interface and communication modules. Soft Start Current Limit Start Dual Ramp Full Voltage Linear Speed Acceleration Preset Slow Speed Soft Stop Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage, overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault. Amps, volts, kw, kwh, mw, mwh, elapsed time, power factor, motor thermal capacity usage. Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, and ground fault Stopped, starting, stopping, at speed, alarm, and fault. Four fully programmable contacts as normal/up-to-speed/fault/alarm/network (N.O./N.C.), or external bypass (N.O. only). Helps reduce fluid surges in centrifugal pumping systems during starting and stopping period. Starting time is adjustable from 0 30 seconds. Stopping time is adjustable from 0 120 seconds. Provides motor braking without additional equipment for applications that require the motor to stop quickly. Braking current is adjustable from 0 400% of the motor s full-load current rating. Provides controlled position stopping. During stopping, braking torque is applied to the motor until it reaches preset slow speed (7% or 15% of rated speed) and holds the motor at this speed until a stop command is given. Braking torque is then applied until the motor reaches zero speed. Braking current is programmable from 0 450% of full-load current. Used on applications that require slow speed (in the forward direction) for positioning or alignment and also require braking control to stop. Wiring Diagram Line Controller Customer supplied. 33

Power Circuit Control Circuit Device Rating UL/CSA/NEMA IEC 200 AC ( 15%, +10%) 200 415V Rated Operation Voltage 600V 200 600V AC ( 15%, +10%) 200 500V 230 600V AC ( 15%, +10%) 230 /Y 500V Rated Insulation Voltage 600V N/A 500V Rated Impulse Voltage 600V N/A 6000V Dielectric Withstand 600V 2200V AC 2500V 1400V 1400V Repetitive Peak Inverse 600V 1600V 1600V Voltage Rating 1800V 1800V Operating Frequency All 50/60 Hz Utilization Category 5 480 A MG 1 AC-53B:3.0-50:1750 625 1250 A MG 1 AC-53B:3.0-50:3550 5 85 A IP20 Protection Against Electrical 108 480 A N/A IP2X (with terminal covers) Shock 625 1250 A IP00 (open device) DV/DT Protection & 600V RC Snubber Network None Transient Protection & 600V Metal Oxide Varistors: 220 Joules None Rated Operational Voltage 5 480 A 100 240V AC or 24V AC/DC 625 1250 A 110/120V AC and 230/240V AC Rated Insulation Voltage All N/A 240V Rated Impulse Voltage All N/A 3000V Dielectric Withstand All 1600V AC 2000V Operating Frequency All 50/60 Hz Input onstate voltage minimum 85V AC, 19.2V DC / 20.4V AC Input onstate current 20 ma @120V AC / 40 ma @ 240V AC, 7.6 ma @ 24V AC/DC Input offstate voltage maximum 50V AC, 10V DC / 12V AC Input offstate current @ input offstate voltage <10 ma AC, <3 ma DC power is only available with 100 240V control. 34

Short Circuit Protection SCPD Performance 200 600V Type 1 SCCR List Max. Standard Max. Standard Max. Standard Max. Circuit Available Fault Fuse (A) Available Fault Breaker (A) Line Device Operational Current Rating (A) Delta Device Operational Current Rating (A) Max. High Fault 5 10 ka 20 10 ka 20 70 ka 10 25 10 ka 100 10 ka 100 70 ka 50 43 10 ka 150 10 ka 150 70 ka 90 60 10 ka 225 10 ka 225 70 ka 125 85 10 ka 300 10 ka 300 70 ka 175 108 18 ka 400 18 ka 300 70 ka 200 135 18 ka 500 18 ka 400 70 ka 225 201 30 ka 600 30 ka 600 70 ka 350 251 30 ka 700 30 ka 700 70 ka 400 317 42 ka 800 30 ka 800 69 ka 500 361 42 ka 1000 30 ka 1000 69 ka 600 480 42 ka 1200 30 ka 1200 69 ka 800 625 42 ka 1600 42 ka 1600 74 ka 1600 780 42 ka 1600 42 ka 2000 74 ka 1600 970 85 ka 2500 85 ka 2500 85 ka 2500 1250 85 ka 3000 85 ka 3200 85 ka 3000 Max. Fuse (A) 8.7 10 ka 35 10 ka 35 70 ka 17.5 43 10 ka 150 10 ka 150 70 ka 90 74 10 ka 300 10 ka 300 70 ka 150 104 10 ka 400 10 ka 300 70 ka 200 147 10 ka 400 10 ka 400 70 ka 200 187 18 ka 500 18 ka 500 70 ka 300 234 18 ka 700 18 ka 700 70 ka 400 348 30 ka 1000 30 ka 1000 70 ka 600 435 42 ka 1200 30 ka 1200 70 ka 800 549 42 ka 1600 30 ka 1600 69 ka 1000 625 42 ka 1600 30 ka 1600 69 ka 1200 831 42 ka 1600 30 ka 1600 69 ka 1600 850 42 ka 1600 42 ka 2000 74 ka 1600 900 42 ka 1600 42 ka 2000 74 ka 1600 1200 85 ka 3000 85 ka 3200 85 ka 3000 1600 85 ka 3000 85 ka 3200 85 ka 3000 SCPD Performance Type 1 SCCR List Device Max. Ampere Tested North Max. Ampere Tested Max. Standard Available Fault Rating American Style European Style 108 70 ka A070URD33xxx500 6,9 grb 73xxx400 6,6URD33xxx500 135 70 ka A070URD33xxx500 6,9 grb 73xxx400 6,6URD33xxx500 201 70 ka A070URD33xxx700 6,9 grb 73xxx630 6,6URD33xxx700 251 70 ka A070URD33xxx700 6,9 grb 73xxx630 6,6URD33xxx700 Maximum FLC 317 70 ka A070URD33xxx900 6,9 grb 73xxx800 6,6URD33xxx900 361 70 ka A070URD33xxx900 6,9 grb 73xxx800 6,6URD33xxx900 480 70 ka A070D33xxx1250 9 URD 73xxx1250 A100URD73xxx1250 625 70 ka A070URD33xxx1400 6,6URD33xxx1400 780 70 ka A070URD33xxx1400 6,6URD33xxx1400 970 85 ka A070URD33xxx1250 1250 85 ka A070URD33xxx1250 Consult local codes for proper sizing of short circuit protection. Non-time delay fuses (K5 5 (8.7 831 A) devices; Class L 625 1250V (850 1600 A) devices). High capacity fault rating when used with time delay class CC, J, or L fuses. 35

Power Requirements Steady State Heat Dissipation with Control and Fan Power (Watts) Auxiliary Contacts 19/20 (Aux #1) 29/30 (Aux #2) 31/32 (Aux #3) 33/34 (Aux #4) PTC Input Ratings Tach Input 120 240V AC Transformer 75 VA 24V AC Transformer 130 VA Inrush Current 5 A Inrush Time 250 ms Control Module 1 480 A Transient Watts 60 W 24V DC Transient Time 500 ms Steady State Watts 24 W Minimum Allen-Bradley Power Supply 1606-XLP50E 625 1250 A 751 VA (recommended 800 VA) 5 135 A, 20 VA Heatsink Fan(s) (A) 201 251 A, 40 VA 317 480 A, 60 VA 625 1250 A, 150 VA 5 70 25 70 43 81 60 97 85 129 108 91 135 104 Controller Rating (A) 201 180 251 198 317 225 361 245 480 290 625 446 780 590 970 812 1250 1222 Type of Control Circuit Electromagnetic relay Number of Contacts 1 Type of Contacts programmable N.O./N.C. Type of Current AC Rated Operational Current 3 A @ 120V AC, 1.5 A @ 240V AC Conventional Thermal Current I th AC/DC 5 A Make/Break VA 3600/360 Utilization Category AC-15/DC Response Resistance 3400 Ω ±150 Ω Reset Resistance 1600 Ω ±100 Ω Short-Circuit Trip Resistance 25 Ω ±10 Ω Max. Voltage at PTC Terminals (R PTC = 4 kω) < 7.5V Max. Voltage at PTC Terminals (R PTC = open) 30V Max. No. of Sensors. 6 Max. Cold Resistance of PTC Sensor Chain 1500 Ω Response Time 800 ms 0 5V DC, 4.5V DC = 100% Speed Heatsink fans can be powered by either 110/120V AC or 220/240V AC. 36

Environmental Operating Temperature Range -5 50 C (23 122 F) (open) -5 40 C (23 104 F) (enclosed) Storage and Transportation Temperature Range 20 +75 C Altitude 2000 m (6560 ft) Humidity 5 95% (non-condensing) Pollution Degree 2 Resistance to Vibration Resistance to Shock Construction Terminals EMC Emission Levels EMC Immunity Levels Overload Characteristics Certifications Mechanical Operational All 1.0 G Peak, 0.15 mm (0.006 in.) displacement Non-Operational Operational Non-Operational 5 480 A 2.5 G Peak, 0.38 mm (0.015 in.) displacement 625 1250 A 1.0 G Peak, 0.15 mm (0.006 in.) displacement 5 85 A 15 G 108 480 A 5.5 G 625 1250 A 4 G 5 85 A 30 G 108 480 A 25 G 625 1250 A 12 G Power Poles 5 85 A Heatsink thyristor modular design Power Poles 108 1250 A Heatsink hockey puck thyristor modular design Control Modules Thermoset and Thermoplastic Moldings Metal Parts Plated Brass, Copper, or Painted Steel Cable size Line Upper 2.5 95 mm2 (14 3/0 AWG) Line Lower 0.8 2.5 mm2 (18 14 AWG) 5 85 A Load Upper 2.5 50 mm2 (14 1 AWG) Load Lower 0.8 2.5 mm2 (18 14 AWG) Tightening torque 14.7 N m (130 lb.-in.) Power Terminals Wire strip length 18 20 mm (0.22 0.34 in.) 108 135 A One M10 x 1.5 diameter hole per power pole 201 251 A Two M10 x 1.5 diameter holes per power pole 317 480 A Two M12 x 1.75 diameter holes per power pole 625 1250 A Two 13.5 mm (0.53 in.) diameter holes per power pole Power Terminal Markings NEMA, CENELEC EN50 012 Control Terminals M3 screw clamp Clamping yoke connection Other Conducted Radio Frequency Emissions Radiated Emissions Electrostatic Discharge Radio Frequency Electromagnetic Field Fast Transient Surge Transient Current Range Trip Classes Trip Current Rating Number of Poles Open Type Controllers Class A Class A 8 kv Air Discharge Line Delta 5 1...5 1.7 9 25 5...25 8.6 43 43 8.6...43 14.8 75 60 12...60 20.8 104 85 17...85 29.4 147 108 27 108 47 187 135 34 135 59 234 201 67 201 116 348 251 84 251 145 435 317 106 317 183 549 361 120 361 208 625 480 160 480 277 831 625 208 625 283 850 780 260 780 300 900 970 323 970 400 1200 1250 416 1250 533 1600 10, 15, 20, and 30 117% of Motor FLC 3 CE Marked Per Low Voltage Directive 73/23/EEC, 93/68/EEC UL Listed (File No. E96956) 37