SMS 4 / SMS 5 safety mat Product information



Similar documents
CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Contact expander modules

Contact expansion modules

E-STOP relays, safety gate monitors

PNOZsigma - Base units

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Safety automation solutions

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

E-STOP relays, safety gate monitors

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Safety Relays ESM/ESM-F

E-STOP relays, safety gate monitors

Manual Motor Starter MS 116 up to 16 A Technical Data

Safety technique. Emergency stop module BO 5988 safemaster

Electronic overload relay EF19 and EF45

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

PHOENIX CONTACT Features

Electronic overload relay EF65, EF96 and EF146

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

HERZ-Thermal Actuators

Guard locking systems for the protection of man and machine

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Pluggable interface relays CR-P Pcb relays

Thermal-Magnetic Circuit Breaker M1-..

Safety Manual BT50(T) Safety relay / Expansion relay

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

40.3. Control Relays and Timers

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

49 Series - Relay interface modules A. Features

Circuit Breakers. NRC Series. NRC Series

Preset Counter signo 721

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

48 SERIES Relay interface modules 10 A

RM4TG20 three-phase network control relay RM4-T - range V

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Single Channel Loop Detector

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Electric Rotary Actuator - On/Off or programmable control actuator

Thyristor-controlled power supplies and battery chargers

PSR The compact range Description

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Preventa Machine Safety Products

Inductive sensor NI10-M18-Y1X-H1141

Quick Connect. quick - simple - efficient.

PNOZ s3. Safety relays. Operating Manual EN-10

Safe switching and monitoring Solenoid Interlocks

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

A good connection. International approvals.

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Power Supplies 3. SDN-P DIN Rail Series

General 1-2-Opto-electronics Safety Switches 4-Emergency

RY2 miniature industrial relays

Solid-State Timer H3G

Three-phase monitoring relay CM-PFE

Vario-Series Accessories

Data Sheet. Electro-mechanical counters Hengstler 800 series

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

PNOZ s5. Safety relays. Operating Manual EN-09

SAFETY LIGHT CURTAINS

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Series 8146/5-V37 and Series 8150/5-V37

Guide to Safety Edge Systems

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

SEISMIC VELOCITY TRANSDUCER T1-40

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

3/2-way Solenoid Valve, direct-acting, NC or NO

Cable Plug acc. to DIN EN , Form A

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Technical Data. Dimensions

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Speed Control Relays SX2

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

MINI MCR-SL-R-UI(-SP)

Transcription:

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are, for instance, the protection of hazardous areas and surfaces on woodprocessing machines, scissor lifts or punching presses. The safety mats build a uniplanar safety device, which detects the presence of persons. If a person steps onto the safety mat, the connected safety-monitoring module will immediately stop the hazardous movement. The safety mats can be connected in line with each other in order to provide for a smooth and fast protection of hazardous areas. To this end, different standard sizes are available. Futhermore, special sizes or special shapes can be realised upon request. The SMS 4 series is connected to the floor by means of an aluminium profile and special corner sections. As a result of the beveled form of the profile, tripping hazards are avoided. The aluminium profile additionally serves as edge protection, when fork-lift trucks or other floor conveyors drive over the safety mats. In the SMS 5 series, the polyurethane actuating profile is directly moulded to the active surface of the safety mat. The safety mats are characterised by their very robust design and high resistance to acids, caustic solutions, oil and gasoline. In combination with the SRB 301HC/R or SRB 301HC/T safety-monitoring modules, the safety mats meet the requirements of control category 3 to EN 954 1. The safety mat consists of two separate current-carrying steel plates. The plates are held apart by insulating strips. Upon actuation of the pressure-sensitive safety mat, an electrical cross-wire short is produced between the steel plates. The connected safetymonitoring module evaluates this signal and stops the hazardous movement. Contact 2

Calculation of the safety distance to the danger point Safety distance The proper arrangement of the safety mat with regard to the adjacent hazardous area mainly depends on the aftertravel time of the machine and the approaching speed of the operator. The standard EN 999 (Safety of Machinery, Approaching Speed of Body Members) provides a formula to calculate the safety distance for this connection. Safety distance S = K x (T1 +T2) + (1200-0.4 H) S Minimum safety distance in millimetres, measured from the hazardous area to the detection point, the detection line or the protected field K Constant in millimetres per second, derived from data through the approaching speed of the body or the body member (1600 mm/s) H Distance through the reference plane (e.g. the floor) in millimetres (for safety mats generally 0 mm) T1 the maximum response time of the safety device between the triggering of the perceptive element (the safety mat) and the time, at which the safety guard (safety-monitoring module) has switched the output signal to the "OFF" state. T2 the response time of the machine, i.e. the time required to shutdown the machine or to eliminate the risk, after the transmission of the output signal of the safety guard The safety distance therefore generally can be calculated in the following way: S = 1600 mm/s x (T1 +T2) + 1200 mm Example: The safety distance must be calculated with a response time of 142.5 ms for the machine and a response time of 45 ms for the safety guard. The safety mat is installed at ground level. S = 1600 mm/s x (0.045 s + 0.1425 s) + 1200 mm S = 1600 mm/s x (0.1875 s) + 1200 mm S = 300 mm + 1200 mm S = 1500 mm 3

Safety mats SMS 4 SMS 5 A A Certified to EN 1760-1 Response time max. 25 ms Robust design High resistance to chemicals Slip-free surface Cascading possible Special sizes and shapes available on request No additional terminating resistor required Aluminium frame and corner sections available 35 A 35 35 35 A Certified to EN 1760-1 Response time max. 25 ms Robust design High resistance to chemicals Slip-free surface Cascading possible Special sizes and shapes available on request No additional terminating resistor required With moulded ramp profile Technical data Standards: EN 1760-1 Control category: 3 to EN 954-1 Surface material: polyurethane, black Protection class: IP 65 to EN 60529 Ambient temperature: 0 C +60 C Fitting height: 14 mm Weight: 17 Kg / m 2 Actuating force: 150N with round body ø 80mm Cable: 4 x 0.34 mm 2 SMS4 2 pc. 2 x 0.34 mm 2 SMS 5 Cable length: 6m Response time: 25 ms Mechanical life: >1.5 million operations Admissible load: 2000 N / 80 mm ø Inactive edge 10mm Classification: (In combination with safety monitoring module SRB 301 HC) Standards: EN ISO 13849-1; IEC 61508; IEC 60947-5-3 PL: up to d Category: up to 3 PFH value: 1.0 x 10-7 /h for max. 52,500 switching cycles/year and max. 60% contact load SIL: up to 2 in combination with safety monitoring module Mission time: 20 years Legend: A: active surface Legend: A: active surface Total size = A + 2 x 35 mm Approvals F SMS 4-➀ No. Option ➀ Description Active surface 250-500 250 x 500 mm 500-500 500 x 500 mm 500-1000 500 x 1000 mm 750-1000 750 x 1000 mm 1000-1000 1000 x 1000 mm 1000-1500 1000 x 1500 mm Approvals F SMS 5-➀ No. Option ➀ Description Active surface 250-500 250 x 500 mm 500-500 500 x 500 mm 500-1000 500 x 1000 mm 750-1000 750 x 1000 mm 1000-1000 1000 x 1000 mm 1000-1500 1000 x 1500 mm Note Chemical resistance: Water : Resistant 10% acids: Resistant 10% caustic solutions: Resistant Oils: Resistant Gasoline: Resistant Other on request 4

67 SMS 4 safety mats accessories System components System components System components 33,5 90,0 90,0 7 17,8 15 7 3 8,5 13 6 18 67 Ramp rail SMS 4-RS-3000 17,8 15 8,5 SMS 4-BS-3000 fixing rail 3 13 40 18,5 7,5 67 15 Corner section SMS 4-EV 67 15 40 67 SMS 4 Ramp rail 3000 mm long SMS 4-RS 3000 Fixing rail 3000 mm long SMS 4-BS-3000 Corner section (1 pc) SMS 4-EV 5

Safety mats SRB 301HC Safety-monitoring module for safety mats 3 enabling contacts 1 signalling contact Cross-wire detection Feedback circuit to monitor external contactors Monitored start or automatic start LED status indication Plug-in terminals Approvals H F Technical data Standards: IEC/EN 60204-1, IEC/EN 60947-5-1, EN ISO 13849-1; IEC 61508; BG-GS-ET-20 Start conditions: automatic or start button (optionally monitored) With feedback circuit (Y/N): yes ON delay with reset button: 50 ms Drop-out delay on "emergency stop": 20 ms Drop-out delay on "supply failure": 100 ms Rated operating voltage U e : 48... 240 VAC; 24 VAC/DC Frequency range: 50 / 60 Hz Fuse rating for the operating voltage: 230 VAC version: primary side: melting fuse, tripping current >1.0 A; secondary side: internal electronic fuse, tripping current > 0.12 A; 24 VAC/DC version: internal electronic fuse, tripping current > 0.5 A Internal electronic fuse (Y/N): 230 VAC version: no 24 VAC/DC version: yes Current consumption: 230 VAC version: 1.6 W; 4.2 VA 24 VAC/DC version: 1.4 W; 3.3 VA Inputs monitoring: Cross-wire detection: yes Wire breakage detection: yes Earth leakage detection: yes Number of NC contacts: 2 Number of NO contacts: 0 Max. total line resistance: 40 W Outputs: Stop category 0: 3 Stop category 1: 0 Number of safety contacts: 3 Number of signalling outputs: 1 Max. switching capacity of the safety contacts: 250 VAC, 8 A ohmic (inductive with suitable protective circuit) Utilisation category to EN 60947-5-1: AC-15: 230 V / 6 A; DC-13: 24 V / 6 A Mechanical life: 10 7 operations Ambient conditions: Operating ambient temperature: 25 C + 60 C Storage and transport temperature: 25 C + 85 C Protection class: enclosure: IP 40, terminals: IP 20, terminal space: IP 54 Mounting: snaps onto standard DIN rails to DIN EN 60715 Connection type: plug-in type screw terminals min. cable section: 0.25 mm 2 max. cable section: 2.5 mm 2 Weight: 230 VAC version: 340 g; 24 VAC/DC version: 320 g Dimensions (height/width/depth): 100 x 45 x 121 mm Classification: Standards: EN ISO 13849-1; IEC 61508; IEC 60947-5-3 PL: up to e Category: up to 4 PFH value: 5.0 x 10-9 /h for max. 36,500 switching cycles/year and max. 60% contact load SIL: up to 3 Mission time: 20 years SRB 301HC/➀-➁ No. Option Description ➀ R Manual start T Automatic start ➁ 230 V 48... 240 VAC 24 V 24 VAC/DC 6

Safety mats Note Protection of a safety mat Start button with edge detection Feedback circuit S to monitor the external contactors Series-wiring of multiple safety mats possible Reset button J Wiring example L1 A1 S13 S14 S23 S24 X2 X3 13 23 33 41 SMS F1 Control logic K1 A2 ON INA K1 K2 SRB 301HC INB OUT KB K2 14 24 34 42 S KA N 3 M Note The wiring example is shown with the safety mat in non-actuated and de-energised condition. Inductive loads (e.g. contactors, relays, etc.) are to be supressed by means of a suitable circuit 7

K.A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D-42279 Wuppertal Postfach 24 02 63 D-42232 Wuppertal Telefon +49 - (0)2 02-64 74-0 Telefax +49 - (0)2 02-64 74-1 00 E-Mail info@schmersal.com Internet www.schmersal.com 3.000 / L.D. / 06.2009 / Teile-Nr. 1208763 / Ausgabe 01