Edwards FloTrac Sensor & Edwards Vigileo Monitor. Measuring Continuous Cardiac Output with the FloTrac Sensor and Vigileo Monitor



Similar documents
Edwards FloTrac Sensor & Edwards Vigileo Monitor. Understanding Stroke Volume Variation and Its Clinical Application

huidige en toekomstige hemodynamische bewaking

Non Invasive Haemodynamic Monitoring. Nick Harrison BACCN May 2015

Hemodynamic Monitoring: Principles to Practice M. L. Cheatham, MD, FACS, FCCM

Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Factors Affecting Blood Pressure. Vessel Elasticity Blood Volume Cardiac Output

Recent Trends in Hemodynamic Monitoring

Section Four: Pulmonary Artery Waveform Interpretation

Blood Pressure. Blood Pressure (mm Hg) pressure exerted by blood against arterial walls. Blood Pressure. Blood Pressure

Normal Intracardiac Pressures. Lancashire & South Cumbria Cardiac Network

3 rd Russian-Bavarian Conference on Bio-Medical Engineering

Note: The left and right sides of the heart must pump exactly the same volume of blood when averaged over a period of time

OEM MAXNIBP Frequently Asked Questions

Fellow TEE Review Workshop Hemodynamic Calculations Director, Intraoperative TEE Program. Johns Hopkins School of Medicine

Normal & Abnormal Intracardiac. Lancashire & South Cumbria Cardiac Network

Electrocardiography I Laboratory

Milwaukee School of Engineering Case Study: Factors that Affect Blood Pressure Instructor Version

Vtial sign #1: PULSE. Vital Signs: Assessment and Interpretation. Factors that influence pulse rate: Importance of Vital Signs

March 31, Etiometry, Inc. Richard Galgon Independent Consulting Associate Quintiles 5846 Cobblestone Lane Waunakee, Wisconsin 53597

Signal Extraction Technology

Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E

UNDERSTANDING CONTINUOUS MIXED VENOUS OXYGEN SATURATION (SvO 2 ) MONITORING WITH THE SWAN-GANZ OXIMETRY TD SYSTEM

INNOC. Innocare-T. Innomed. Innomed s intensive and anesthesiological monitor system can be used both as a transport or bed-side care unit

Low-gradient severe aortic stenosis with normal LVEF: A disturbing clinical entity

The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.

An Introduction to Blood Pressure

The Sepsis Puzzle: Identification, Monitoring and Early Goal Directed Therapy

Spurious systolic hypertension 143

GE Healthcare. B40 Patient Monitor Connecting intelligence and care.

MICROGRAVITY EFFECTS ON HUMAN PHYSIOLOGY: CIRCULATORY SYSTEM

Update on Small Animal Cardiopulmonary Resuscitation (CPR)- is anything new?

MY TYPE 2 DIABETES NUMBERS

Critical Care Therapy and Respiratory Care Section

Spirodoc. One Touch Laboratory for respiratory analysis two functional modes: doctor and patient. Spirometer with Touch Screen display

Vascular System The heart can be thought of 2 separate pumps from the right ventricle, blood is pumped at a low pressure to the lungs and then back

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

UW MEDICINE PATIENT EDUCATION. Aortic Stenosis. What is heart valve disease? What is aortic stenosis?

HEART HEALTH WEEK 3 SUPPLEMENT. A Beginner s Guide to Cardiovascular Disease HEART FAILURE. Relatively mild, symptoms with intense exercise

Acute heart failure may be de novo or it may be a decompensation of chronic heart failure.

Traumatic Cardiac Tamponade. Shane KF Seal 19 November 2003 POS

Oxygen Transport Calculations M. L. Cheatham, MD, FACS, FCCM

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

From AARC Protocol Committee; Subcommittee Adult Critical Care Version 1.0a (Sept., 2003), Subcommittee Chair, Susan P. Pilbeam

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Fundamentals of Critical Care: Hemodynamics, Monitoring, Shock

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care

Using Current Transformers with the 78M661x

Introduction to Cardiopulmonary Exercise Testing

Responses to Static (Isometric) Exercise

Left to Right Shunts and their Calculation. Ghada El Shahed, MD

High-intensity performance. IntelliVue MP90 patient monitor

Waveforms. INTRODUCTION TO THE HEARTWARE WAVEFORM ipad APP

CHAPTER THREE COMMON DESCRIPTIVE STATISTICS COMMON DESCRIPTIVE STATISTICS / 13

PulseCO: A Less-Invasive Method to Monitor Cardiac Output From Arterial Pressure After Cardiac Surgery

Educational Goals & Objectives

INVESTIGATING HEART RATE AND BLOOD PRESSURE

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

Plastic Film Texture Measurement With 3D Profilometry

Parkland College RTT 213 Syllabus. Respiratory Therapy VI: Management of the Critically Ill Patient

Pressure Sensor Based Estimation of Pulse Transit Time

Optimizing Masimo SET SpO2 Alarm Settings on Select GE Monitors

Inpatient Code Sepsis March Update. Sarah Prebil

Enhancements on SCP-ECG protocol for multi vital-sign handling

Cardiogenic shock: invasive and non-invasive monitoring John T. Parissis Attikon University Hospital Athens, Greece

Over the past decade, the use of evidencebased. Interpretation and Use of Statistics in Nursing Research ABSTRACT

Scatter Plots with Error Bars

Algebra 1 Course Information

Cardiovascular Physiology

HEALTH MANAGEMENT PLAN PROGRAMME

Workshop B: Essentials of Neonatal Cardiology and CHD Anthony C. Chang, MD, MBA, MPH CARDIAC INTENSIVE CARE

High Blood Pressure (Essential Hypertension)

Starling s Law Regulation of Myocardial Performance Intrinsic Regulation of Myocardial Performance

Bedside Monitor BSM-9101K

Section Two: Arterial Pressure Monitoring

Minimally Invasive Cardiac Output Monitoring in the Year 2012

Nellcor Pulse Oximeters with OxiMax Technology from Covidien

X X X a) perfect linear correlation b) no correlation c) positive correlation (r = 1) (r = 0) (0 < r < 1)

CYMAQ Marking System AS200 + DS7050 N-14

Oxygenation and Oxygen Therapy Michael Billow, D.O.

K-Type Thermocouple Sensor User s Guide

Anatomi & Fysiologi The cardiovascular system (chapter 20) The circulation system transports; What the heart can do;

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

Management of the Patient with Aortic Stenosis undergoing Non-cardiac Surgery

Characterizing Digital Cameras with the Photon Transfer Curve

Estimation of Sympathetic and Parasympathetic Level during Orthostatic Stress using Artificial Neural Networks

Mathematics and Statistics: Apply probability methods in solving problems (91267)

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

VITALMONITOR SOFTWARE FOR PATIENT MONITORING

Networked versatility. IntelliVue MP60 and MP70 patient monitors

Mind on Statistics. Chapter 2

Puritan Bennett 980 Ventilator Patient Setup Quick Reference Guide

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

Exploratory data analysis (Chapter 2) Fall 2011

Mathematics Online Instructional Materials Correlation to the 2009 Algebra I Standards of Learning and Curriculum Framework

This unit will lay the groundwork for later units where the students will extend this knowledge to quadratic and exponential functions.

Human Anatomy & Physiology II with Dr. Hubley

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Transcription:

Edwards FloTrac Sensor & Edwards Vigileo Monitor Measuring Continuous Cardiac Output with the FloTrac Sensor and Vigileo Monitor 1

Topics System Configuration Physiological Principles Pulse pressure relationship with stroke volume Calculating Arterial Pressure-Based Cardiac Output (APCO) Assessing pulse pressure Assessing patient specific effects of vascular tone Measuring CO Without a Manual Method of Calibration 2

System Configuration PreSep Catheter (ScvO 2 ) Venous Oximetry Vigileo Monitor Cardiac Output FloTrac Sensor (peripheral artery) The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep central venous catheter for continuous central venous oximetry (ScvO2) 3

Vigileo Monitor Continuously computes stroke volume from the patients arterial pressure signal Displays key hemodynamic parameters on a continuous basis (every 20 sec) Requires NO manual calibration The user simply enters patient age, gender, height and weight to initiate monitoring Advanced waveform analysis compensates for: Patient-to-patient differences in vasculature Real time changes in vascular tone Differing arterial sites Venous oximetry available when used with appropriate Edwards oximetry technology The Vigileo monitor continuously displays and updates Continuous Cardiac Output, Cardiac Index, Stroke Volume, Stroke Volume Index, Systemic Vascular Resistance*, Systemic Vascular Resistance Index*, and Stroke Volume Variation every 20 seconds when used with the FloTrac sensor. DO2 and DO2I are also available for intermittent calculation.** These parameters help guide the clinician in optimizing stroke volume through precision guided management of preload, afterload, and contractility. Vascular tone = vessel compliance and resistance The Vigileo monitor then helps identify the adequacy of cardiac output by monitoring central venous (ScvO2) or mixed venous (SvO2) oxygen saturation when used with Edwards venous oximetry technologies. * These parameters require the CVP value to be slaved from bedside monitor for continuous monitoring. SVR/SVRI can also be assessed on the Derived Value Calculator for intermittent calculations using either slaved or manually entered MAP, CVP, and CO values. **These parameters require the SpO2 and PaO2 values to be manually entered. If CO is being continuously monitored, the calculator will default to the existing CO value. Otherwise, the user may override the continuous value to manually enter CO. 4

FloTrac Sensor The specially designed FloTrac sensor provides the high fidelity arterial pressure signal required by the Vigileo monitor to calculate the stroke volume The Vigileo monitor uses the patient s arterial pressure waveform to continuously measure cardiac output. With inputs of height, weight, age and gender, patient-specific vascular compliance is determined. The FloTrac sensor measures the variations of the arterial pressure which is proportional to stroke volume. Vascular compliance and changes in vascular resistance are internally compensated for. Cardiac output is displayed on a continuous basis by multiplying the pulse rate and calculated stroke volume as determined from the pressure waveform. The FloTrac sensor is easily setup and calibrated at the bedside using the familiar skills used in pressure monitoring. 5

How does the FloTrac system s s APCO algorithm work? (Arterial Pressure-based Cardiac Output) 6

The Relationship of Pulse Pressure to Stroke Volume The difference between these two pressures [systolic and diastolic pressures]... is called the pulse pressure. - Guyton AC, Textbook of medical physiology, WB Saunders, 1991; 221-233. Aortic pulse pressure is proportional to SV and is inversely related to aortic compliance. - Boulain (CHEST 2002; 121:1245-1252) In general, the greater the stroke volume output, the greater is the amount of blood that must be accommodated in the arterial tree with each heartbeat and, therefore, the greater the pressure rise and fall during systole and diastole, thus causing a greater pulse pressure. - Guyton AC, Textbook of medical physiology, WB Saunders, 1991; 221-233. The measurement algorithm starts with the premise that stroke volume is proportional to pulse pressure. We see from these references that the pulse pressure is simply the difference between systolic and diastolic pressure and that an increase in stroke volume will be shown by an increase in pulse pressure. We also see that compliance will have an effect on pulse pressure. That is the greater the compliance for any given SV, the lesser the pulse pressure. 7

pulse pressure is proportional to SV and is inversely related to aortic compliance. Boulain (CHEST 2002; 121:1245-1252) sd(ap) APCO = PR * sd(ap) SV * χ Measures pulse rate Beats identified by upslope of waveforms Pulse rate computed from time period of beats Based upon the basic physiological principle of pulse pressure s (PP) proportionality to SV sd(ap)* utilized to compute a robust assessment of key PP characteristics Computed on a beat by beat basis Compensates for differences in vascular tone (compliance and resistance) Patient-to-patient differences estimated from biometric data Dynamic changes estimated by data and waveform analysis * sd(ap) = standard deviation of arterial pressure, X (pronounced Khi ) Cardiac Output is calculated by multiplying Heart Rate times Stroke Volume. The APCO algorithm uses Pulse Rate calculated from the arterial pressure signal. Stroke Volume is calculated by multiplying the standard deviation of the arterial pressure sd(ap) signal against Khi (X). 8

The calculation of pulse pressure and its proportionality to SV: sd(ap) 9

Trending Stroke Volume Systolic press. PP SV Arterial pressure is sampled at 100 Hz Diastolic press. Changes in stroke volume will result in corresponding changes in the pulse pressure A robust whole waveform measure of the pulse pressure is achieved by taking the standard deviation of the sampled points of each beat sd(ap) Pulse Pressure Stroke Volume SV estimates are calculated every 20 sec Arterial pressure is sampled at 100 times per second (100 Hz). Each sample is a pressure data point measured in mm Hg. This data is analyzed and updated every 20 seconds, utilizing the 2000 data points (20 sec x 100 Hz) collected. The standard deviation (sd(ap)) of these data points is proportional to the pulse pressure, which is proportional to the stroke volume. This method is robust in its assessment of pulse pressure because it looks at the whole waveform. sd(ap) = a measure of variance The Stroke Volume is averaged and displayed every 20 seconds. The user has the capability to choose between a 20 second calculation or 5 minute moving average option. 10

sd is a measure of variation of the AP Therefore, with a constant vasculature AP Variation sd(ap) SV X time X time X time AP Variation sd(ap) SV This graphic shows the relationship between varying arterial pulse pressure and stroke volume in the presence of a constant vasculature. The sd(ap) is simply a statistical tool used in the algorithm for quantitatively assessing the magnitude of pulse pressure, correlated with an estimated stroke volume. Since we know that an individual s vasculature is not constant, an assessment of vascular tone must also be included in the calculation as it will affect the relationship between pulse pressure and stroke volume. 11

Including the effect of vascular tone in the calculation of flow: 12

The Effect of Compliance on PP: Age, Gender and BSA factors Younger Male Higher BSA vs. vs. vs. Older Female Lower BSA For the same volume Compliance inversely affects PP The algorithm compensates for the effects of compliance on PP based on age, gender, and BSA There is a direct relationship (i.e., the shape of the trend shown above) between arterial pressure and large vessel compliance as it relates to a human s age or gender. That is, a male will typically have a more compliant aorta than a female of the same age, and a younger person will have a more compliant aorta than an elderly person. This relationship was quantified and mathematically modeled by Langewouters. Through development of the algorithm, it has also been found that there is a relationship between aortic compliance and BSA. For example, a larger person (higher BSA) will typically have more compliant vessels than a smaller person (lower BSA). As part of the assessment for vascular tone, estimates of aortic compliance based on the above principles are important but not all encompassing. Therefore, in addition to Langewouter s mathematical model, further waveform analysis is conducted by the algorithm to take into account patient specific, real time effects of vascular tone on the waveform. 13

Effect of Vascular Tone The algorithm looks for characteristic changes in the arterial pressure waveform that reflect changes in tone (i.e., MAP, Skewness, Kurtosis) Those changes are included in the continuous calculation of χ MAP Skewness Kurtosis The aortic compliance function (i.e., age, gender, BSA function) within X helps to provide a ballpark estimate of the patient s likely vascular tone. Further analysis of the waveform shape is also a significant factor to providing vascular tone estimates essential to the SV calculation. This method allows for reliable calculation of key flow parameters without manual calibration. X (pronounced khi ) = a symbol for dynamic polynomial functions, a function that continuously adjusts to multiple changing variables Depending upon the state of the patient s vasculature, the arterial waveform will take a shape that can be characterized mathematically. The statistical tools used, in addition to the aforementioned standard deviation, are the mean, skewness and kurtosis. Mean, clinically known as MAP, can provide an indication of the increase or decrease in resistance. Skewness, or symmetry of the data, is also often associated with the stiffness of the patient s vasculature. Kurtosis, a measure of how peaked or flat the data distribution is, provides an indication of the nature of vasculature as well. For example, larger vessels will typically have a flat distribution as compared to peripheral vasculature. Skewness: The angle or slope exhibited on the rise of the waveform. Kurtosis: How flat and wide the waveform is If the shape changes, the mathematical calculation will change, providing a patient-specific, real time assessment of shifts in vascular tone. The greater the magnitude increase in tone, as calculated as a decrease in X, the lesser the weight pulse pressure estimates (i.e., sd(ap)) will have in the SV calculation 14

Requires NO Manual Calibration Other continuous monitoring technologies require calibration to accommodate for the effects of independent variables associated with changing vascular tone The APCO algorithm compensates for the continuously changing effects of vascular tone via analysis of waveform characteristics directly correlated with vascular tone Continuous, patient-specific monitoring without manual calibration In building the algorithm, comparisons were made between known stroke volume with a given PP comparable (i.e., sd(ap)). Furthermore, statistical correlations were found that provided a mathematical model for providing a quantitative assessment of vascular tone effects on SV. The foundations for these correlations are: the known SVs corresponding PP comparables, continuous arterial pressure data, and the patients age, gender, and BSA. By utilizing these empirical data relationships established during development of the algorithm, the system is able to correlate pressure calculations with stroke volume without requiring a manual process of calibration (e.g., thermodilution, lithium dilution washout curve) and remains accurate when changes in tone occur. Other pulse contour or pulse power based technologies require a dilution washout curve to provide a calibration constant, compensating for these algorithms inability to independently assess the ever-changing effects of vascular tone on SV. 15

CCO (and more)... Directly From the Arterial Line The FloTrac sensor enables clinicians to monitor critically ill patients with parameters traditionally only available through more invasive means. 16

Any quotes used in this material are taken from independent third-party publications and are not intended to imply that such third party reviewed or endorsed any of the products of Edwards Lifesciences. Rx only. See instructions for use for full prescribing information. Edwards Lifesciences devices placed on the European market meeting the essential requirements referred to in Article 3 of the Medical Device Directive 93/42/EEC bear the CE marking of conformity. Edwards, the stylized E logo, FloTrac and Vigileo are trademarks of Edwards Lifesciences Corporation. Edwards Lifesciences and PreSep are trademarks of Edwards Lifesciences Corporation and are registered in the United States Patent and Trademark Office. 2006 Edwards Lifesciences LLC All rights reserved. AR01241 17

18