Non Invasive Haemodynamic Monitoring. Nick Harrison BACCN May 2015
|
|
- Dora Casey
- 7 years ago
- Views:
Transcription
1 Non Invasive Haemodynamic Monitoring Nick Harrison BACCN May 2015
2
3 Hemodynamic monitoring is a cornerstone of care for the hemodynamically unstable patient, but it requires a manifold approach and its use is both context and disease specific. One of the primary goals of hemodynamic monitoring is to alert the health care team to impending cardiovascular crisis before organ injury ensues.
4 Does it matter which haemodynamic monitor to use? Finally, no monitoring tool, no matter how accurate, by itself has improved patient outcome. Pinskey et al (2005)
5 Adolf Fick The principle: " the total uptake of (or release of) a substance by the peripheral tissues is equal to the product of the blood flow to the peripheral tissues and the arterial-venous concentration difference (gradient) of the substance." It is the blood flow we are interested in: this is cardiac output.
6 Fick The True Gold Standard VO 2, the oxygen consumption, is simply the difference between the inspired and expired O 2. You can measure it with an exhaled gas collection bag. You can also estimate it. Conventionally, resting metabolic consumption of oxygen is 3.5 ml of O 2 per kg per minute, or 125ml O 2 per square meter of body surface area per minute. Lets say the meaty pinkish lump below is the patient.
7 Fick teaches us that VO 2 (oxygen extraction) is determined by the following equation: We can rearrange that to form an equation which calculates cardiac output on the basis of oxygen extraction: So, in a normal person, with a body surface area of 2m 2 and thus with a VO 2 of 250ml per minute, CO = 250ml / (200ml 150ml) = 250 / 50 = 5 L/min
8 Where are we Now? Bolus thermodilution Transpulmonary thermodilution Lithium dilution Doppler technique Pulse contour analysis Carbon dioxide rebreathing Bioimpedence / Bioreactance Echocradiography Peripheral pulse variation
9 Choices, Choices
10 Things to consider Theoretical considerations for choosing among hemodynamic monitoring tools Hardware considerations for choosing among hemodynamic monitoring tools Patient-bound considerations for tailoring hemodynamic monitoring Slagt et al. Critical Care 2010, 14:208
11 The New Gold Standard
12
13 Problems Extreme level invasiveness Advanced training for placement Incorrect parameter interpretation Complications Arrhythmias Pulmonary rupture Air embolism Most studies focusing on the PAC and outcome have shown no positive association between PAC use for fluid management and survival in the ICU. Wheeler et al. N Engl J Med 2006, 354:
14 Doppler Technology Prof Mervyn Singer is Professor of Intensive Care Medicine at University College First described in mid 1970 s and gained popularity in the 1990 s (Gan and Arrowsmith) Measures blood flow velocity in the descending aorta using flexible ultrasound probe ( 4-5MHz). Measurement combined with estimated cross sectional area of aorta, age, height and weight give haemodynamic variables
15
16 Values Stroke Distance: Distance in cm column of blood moves along aorta with every ventricular beat Changes in SD directly related to stroke volume Stroke Volume Amount of blood ejected by heart each beat Flow time Corrected (FTc) Is the duration of flow during systole corrected for the heart rate ( ms) Peak Velocity Highest blood velocity during systole Age dependent - Age 20yrs 50yrs 70yrs PV cm/s cm/s 50-80cm/s
17 Minimally invasive Minimal technical skill required for insertion Good correlation with PAC. Recommended for use in high risk surgery (NICE) Remember Cross section must be accurate Ultrasound beam must be directed parallel to the blood flow Beam direction must NOT undergo any major alterations between measurements (King and Lim (2004), Kauffamn (2000), Prentice and Sonna (2006), Lavdaniti (2008), Tomlin (1975), NICE 2011)
18 Transpulmonary Thermodilution and Pulse Contour Cardiac Output Systems can be divided into 3 categories: Pulse contour analysis requiring and an indicator dilution CO measurement to calibrate the pulse contour (LiDCO, PiCCO, Volumeview ) Pulse contour analysis requiring patient demographic and physical characteristics for arterial impudence estimation (FloTrac, NextFin, Radical 7). Pulse contour analysis that does not require calibration or preloaded data (Most Care System)
19 Pulse Contour Analysis The origin of the pulse contour method of measuring cardiac output is derived from variations in the pulse pressure waveform. In general, the greater the stroke volume, the greater is the amount of blood that must be accommodated in the arterial tree with each heartbeat and, therefore, the greater the pressure rise and fall during systole and diastole, thus causing a greater pulse pressure. The pulse pressure is proportional to stroke volume and inversely related to vascular compliance. Aortic pulse pressure is proportional to SV and is inversely related to aortic compliance. (Chest 2002)
20 Stroke Volume (Pulse pressure ~ Stroke Volume) Aortic Compliance (As the compliance of the vasculature is difficult to measure directly, this is calculated based on age, sex, ethnicity and body mass index (BMI)) Brumfield AMPhysiol Meas 2005;26: Vascular Tone (clinical condition and therapeutic approach)
21 LiDCO First described in Combines pulse power analysis with lithium dilution technique Requires a venous line and arterial catheter Lithium is injected via vein and arterial concentration sampled across a lithium electrode at a rate of 4mls/min. Provides an accurate calibration and corrects for arterial compliance and variation among individuals.
22 Power pulse analysis the magnitude in change of pressure is equal to the magnitude of change in stroke volume The heart rate is calculated by drawing an imaginary line through the arterial waveform. Cardiac output in PulseCo is an estimated figure due to assumption of aortic compliance (Remington et al 1948) uses accepted figure of 250mls. People vary so necessary to calibrate: ΔV / Δbp = calibration x 250 x e k.bp
23
24 Advantages Any arterial site can be used. Damping effects of the transducer system is reduced. Safe and accurate (Hett & Jones 2003) Can be calibrated with any form of CO measurement Good correlation with PAC (Costa et al 2008)
25 Calibration can be time consuming Expense Not recommended in first trimester of pregnancy Under 40kgs Patients receiving NMB can cause delay Aortic valve regurgitation
26 Transpulmonary Thermodilution and Pulse Contour Analysis (TPCO) PiCCO and VolumeView Requires a central vein catheterisation and arterial catheter (femoral preferable) Continuous pulse contour SV is calculated from the area under systolic portion of the arterial waveform Shape of arterial waveform, arterial compliance, SVR These devices use the same basic principles of dilution to estimate the cardiac output as with PAC thermodilution
27
28 PediaSa t Catheter EV1000 Clinical Platform Vigileo Monitor Critical Care Educatio n Product Catalog Request Informat ion Home / Products / Advanced Hemodynamic Monitoring / VolumeView Set / VolumeView System Set Up Advance d Hemody namic Monitori ng Volu mevi ew Syste m Set Up VolumeVie w sensor VolumeVie w femoral arterial catheter VolumeVie w thermistor manifold CVC standard TruWave pressure transducer EV1000 clinical platform Rear view of databox Product DetailsBro chure Models Paramete rs Set Up The Set Education al Materials Quick Guide 2nd Edition Technolog y Overview Video Physiologi c Implication s of Appropriat e Resuscitati on Fluid Responsive ness in the Critically Ill Patient elearning Module Related ProductsE V1000 Clinical Platform PreSep Catheter Experience the Edwards Critical Care System MICROSITE VolumeView sensor VolumeView femoral arterial catheter VolumeView thermistor manifold CVC standard TruWave pressure transducer EV1000 clinical platform Hemodynamic Parameters CO - Calibrated Cardiac Output SV - Calibrated Stroke Volume SVR - Systemic Vascular Resistance SVV - Stroke Volume Variation SVI - Stroke Volume Index Volumetric Parameters EVLW - Extravascular Lung Water PVPI - Pulmonary Vascular Permeability Index GEDV - Global End Diastolic Volume GEF - Global Ejection Fraction
29
30 Advantages Continuous cardiac output monitoring Good accuracy Disadvantages Can be complicated to set up Needs specific femoral artery catheter Remains significantly invasive Can be effected by arrhythmias
31 Vigileo Each of these systems contains a proprietary algorithm for converting a pressure-based signal into a flow measurement. Needs no external calibration Use the equation SV = SD AP x (Khi)ᵡ Analyses the area under the systolic portion of the arterial pressure waveform from the end diastole phase to the end of the ejection phase corresponds to SV.
32 The pulse pressure is obtained by the complete analysis of the arterial waveform and through the calculation of the standard deviation (sd) at each sample points. (sampling rate of 100Hz results in 2000 data points) sd(ap) ~ Pulse Pressure ~ Stroke Volume The SV value is updated every 20 seconds
33 The variations or changes in the vascular tone are integrated in a continuous calibration factor (Khi x ) obtained from a multivariate equation of two major elements : APCO algorithm Biometric variables : age, sex, height (Langewouters et al.) Shape variables : analysis of the different characteristics of the arterial pressure waveform. Skewness (Dissymmetry coefficient) Kurtosis (Flattening coefficient) Pulsatility
34 Advantages Easy to set up Needs no external calibration
35 Areas of Concern Outdated and superseded Over the past 5 years and many software updates much research has identified the Vigileo as inaccurate at determining haemodynamic variables within a host of critical care patients. Poor accuracy with arrhythmia. SVV only reliable in mechanically ventilated patients Requires specific arterial pressure sensor Cannot track changes in large vasomotor swings..
36 Partial CO 2 Rebreathing Uses the Fick principle with CO 2 as the marker gas (Berton & Chorley 2002) System distributed is called NICO (Philips) The CO 2 partial rebreathing technique compares end-tidal carbon dioxide partial pressure obtained during a nonrebreathing period with that obtained during a subsequent rebreathing period. The ratio of the change in end-tidal carbon dioxide and CO 2 elimination after a brief period of partial rebreathing (usually 50 seconds) provides a non-invasive estimate of the CO.
37 Partial CO 2 rebreathing (NICO ) *minimal tidal volume = 200ml
38 There are several limitations to this device including: The need for intubation and mechanical ventilation with fixed ventilator settings and minimal gas exchange abnormalities. Gueret G et al Eur J Anaesthesiology (2006), 23: Variations in ventilator settings, mechanically assisted spontaneous breathing, the presence of increased pulmonary shunt fraction, and hemodynamic instability have been associated with decreased accuracy. Tachibana K et al Anaesthesiology (2003), 98: Considering the limitations of this technology and the potential inaccuracies, the routine use of the CO 2 rebreathing technique to guide fluid and vasopressor therapy cannot be recommended.
39 Thoracic Electrical Bioimpedance impedance = measure of opposition to alternating current (AC) How it works: superficial electrodes applied to chest that both measure and apply voltage current is transmitted through the chest via the path of least resistance (aorta) portion of initial (known) voltage that reaches a distant sensing electrode is measured baseline impedance to the current is recorded with each heartbeat, blood volume and velocity in the aorta change corresponding change in impedance change in impedance used to calculate stroke volume and cardiac output according to algorithm based on changes in thoracic blood volume
40
41 Bioimpedance / Bioreactance Developed since the 1960 s (NASA) 4 electrodes in pairs each pair comprises transmitting and sensing properties High frequency current of known amplitude and frequency across the chest measures changes in voltage. Ratios between voltage and current amplitudes = impedance (Zo), and varies in proportion of amount of fluid in the chest. Changes in impedance correlates with SV:
42 Cheetah NICOM
43 CAPTURES (14 ) PARAMETERS In Real Time TPR : Dynes (MAP / CO)*80 TPR : mmhg * min./liters (MAP / CO) TFCd : % Change in TFC over 15 mins. Vs. baseline TFC CP: MAP*CO/451 CPI: SVR CP/BSA MAP-CVP / CO CO CI SV SVV SVI HR TPR VET MAP NIBP TFC Cardiac Output Cardiac Index Stoke Volume Stroke Volume Variance Stroke Volume Index Heart Rate Total Peripheral Resistance Ventricular Ejection Time Mean Arterial Pressure Non Invasive Blood Pressure Thoracic Fluid Content TFCd % Directional Change in TFC/Time CP CPI Cardiac Power Cardiac Power Index
44 Limitations However, a poor correlation between derived CO and that determined by thermodilution in the setting of a cardiac catheterization laboratory was reported. In the Bioimpedance CardioGraphy (BIG) substudy of the ESCAPE heart failure study, there was a poor agreement among TEB and invasively measured hemodynamic profiles. Kamath et al (2009) Heart J 158: Bioimpedance has been found to be inaccurate in the intensive care unit and other settings in which significant electric noise and body motion exist and in patients with increased lung water. Gujjar et al (2008) J Clin Monit Comput 22: Furthermore, this technique is sensitive to the placement of the electrodes on the body, variations in patient body size, and other physical factors that impact on electric conductivity between the electrodes and the skin (eg, temperature and humidity)
45 This device provides a non-invasive estimation of cardiac output in two steps For this purpose, the device includes an inflatable cuff that is wrapped around a finger. It also includes a photoplethysmographic device that measures the diameter of the finger arteries. At each systole, the photoplethysmographic device senses the increase of the finger arteries diameter. A fast servo controlled system immediately inflates the cuff in order to keep the arteries diameter constant. Therefore, cuff pressure reflects the arterial pressure. Its continuous measurement allows estimation of the arterial pressure curve. The second step is to estimate cardiac output from the non-invasive arterial pressure curve. For this purpose, the Nexfin device includes pulse contour analysis software that computes cardiac output from the arterial pressure curve
46
47 Stroke Volume 10 % Lower PVI = Less likely to respond to fluid administration 24 % 0 0 Maxime Cannesson, MD, PhD Preload
48 Pleth variability index (PVI) is a new algorithm allowing automated and continuous monitoring of respiratory variations in the pulse oximetry plethysmographic waveform amplitude. PVI can predict fluid responsiveness noninvasively in mechanically ventilated patients during general anesthesia
49 Echocardiogram Although echocardiography traditionally is not considered a monitoring device, both transthoracic and transesophageal echocardiography provide invaluable information on both left and right ventricular function, which is crucial in the management of hemodynamically unstable patients. Levitov et al (2012) Cardiol Res Pract: Salem et al (2008) Curr Opin Crit Care 14:
50 Choose wisely.
51 Algorithms
52
53
54 Remember. Treat the patient Don t treat the monitors Depending on the clinical setting, adequate monitoring can definitely help the clinician to better treat his patient and improve the final outcome.
55 Maybe in the Future our patients will look like this!! Oxygenation Perfusion
56 Any Questions
Edwards FloTrac Sensor & Edwards Vigileo Monitor. Measuring Continuous Cardiac Output with the FloTrac Sensor and Vigileo Monitor
Edwards FloTrac Sensor & Edwards Vigileo Monitor Measuring Continuous Cardiac Output with the FloTrac Sensor and Vigileo Monitor 1 Topics System Configuration Physiological Principles Pulse pressure relationship
More informationEdwards FloTrac Sensor & Edwards Vigileo Monitor. Understanding Stroke Volume Variation and Its Clinical Application
Edwards FloTrac Sensor & Edwards Vigileo Monitor Understanding Stroke Volume Variation and Its Clinical Application 1 Topics System Configuration Pulsus Paradoxes Reversed Pulsus Paradoxus What is Stroke
More informationhuidige en toekomstige hemodynamische bewaking
huidige en toekomstige hemodynamische bewaking Stefan De Hert Department of Anesthesiology Ghent University Hospital Ghent University Belgium disclosures? 2 hemodynamic monitoring? ~ adequacy of organ
More informationRecent Trends in Hemodynamic Monitoring
As Published in Recent Trends in Hemodynamic Monitoring by Anne Staylor In critical care, the goal of hemodynamic monitoring is to provide data that guides treatment and prevents morbidity and mortality
More informationFellow TEE Review Workshop Hemodynamic Calculations 2013. Director, Intraoperative TEE Program. Johns Hopkins School of Medicine
Fellow TEE Review Workshop Hemodynamic Calculations 2013 Mary Beth Brady, MD, FASE Director, Intraoperative TEE Program Johns Hopkins School of Medicine At the conclusion of the workshop, the participants
More informationMinimally Invasive Cardiac Output Monitoring in the Year 2012
Chapter 4 Minimally Invasive Cardiac Output Monitoring in the Year 2012 Lester Augustus Hall Critchley Additional information is available at the end of the chapter http://dx.doi.org/10.5772/54413 1. Introduction
More informationHemodynamic Monitoring: Principles to Practice M. L. Cheatham, MD, FACS, FCCM
SUMMARY HEMODYNAMIC MONITORING: FROM PRINCIPLES TO PRACTICE Michael L. Cheatham, MD, FACS, FCCM Director, Surgical Intensive Care Units Orlando Regional Medical Center Orlando, Florida Fluid-filled catheters
More informationDESPITE IMPROVEMENTS in resuscitation and supportive
REVIEW ARTICLE Paul G. Barash, MD Giovanni Landoni, MD Section Editors Noninvasive Cardiac Output Monitors: A State-of the-art Review DESPITE IMPROVEMENTS in resuscitation and supportive care, progressive
More informationCardiogenic shock: invasive and non-invasive monitoring John T. Parissis Attikon University Hospital Athens, Greece
Cardiogenic shock: invasive and non-invasive monitoring John T. Parissis Attikon University Hospital Athens, Greece Disclosures: Research grants by Abbott USA and Orion-Pharma as a member of steering committee
More informationNon-invasive estimation of cardiac output in mechanically ventilated patients
UNIVERSITÀ CAMPUS BIO-MEDICO DI ROMA PhD course in Biomedical Engineering (XXIV - 2009/2011) Non-invasive estimation of cardiac output in mechanically ventilated patients Stefano Cecchini Coordinator Prof.
More informationDoppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19
Doppler Doppler Chapter 19 A moving train with a trumpet player holding the same tone for a very long time travels from your left to your right. The tone changes relative the motion of you (receiver) and
More informationNote: The left and right sides of the heart must pump exactly the same volume of blood when averaged over a period of time
page 1 HEART AS A PUMP A. Functional Anatomy of the Heart 1. Two pumps, arranged in series a. right heart: receives blood from the systemic circulation (via the great veins and vena cava) and pumps blood
More informationIntroduction to Cardiopulmonary Exercise Testing
Introduction to Cardiopulmonary Exercise Testing 2 nd Edition Andrew M. Luks, MD Robb Glenny, MD H. Thomas Robertson, MD Division of Pulmonary and Critical Care Medicine University of Washington Section
More informationLow-gradient severe aortic stenosis with normal LVEF: A disturbing clinical entity
Low-gradient severe aortic stenosis with normal LVEF: A disturbing clinical entity Jean-Luc MONIN, MD, PhD Henri Mondor University Hospital Créteil, FRANCE Disclosures : None 77-year-old woman, mild dyspnea
More informationVentilation Perfusion Relationships
Ventilation Perfusion Relationships VENTILATION PERFUSION RATIO Ideally, each alveolus in the lungs would receive the same amount of ventilation and pulmonary capillary blood flow (perfusion). In reality,
More informationInpatient Code Sepsis March Update. Sarah Prebil
Inpatient Code Sepsis March Update Sarah Prebil 3 hour bundle Time is life Kumar et al. Crit Care Med 2006; 34:1589-1596 But Sarah, why are you harassing us about sepsis? Pilot Results 10 Code Sepsis pabents
More informationUpdate on Small Animal Cardiopulmonary Resuscitation (CPR)- is anything new?
Update on Small Animal Cardiopulmonary Resuscitation (CPR)- is anything new? DVM, DACVA Objective: Update on the new Small animal guidelines for CPR and a discussion of the 2012 Reassessment Campaign on
More informationSection Four: Pulmonary Artery Waveform Interpretation
Section Four: Pulmonary Artery Waveform Interpretation All hemodynamic pressures and waveforms are generated by pressure changes in the heart caused by myocardial contraction (systole) and relaxation/filling
More informationAcute heart failure may be de novo or it may be a decompensation of chronic heart failure.
Management of Acute Left Ventricular Failure Acute left ventricular failure presents as pulmonary oedema due to increased pressure in the pulmonary capillaries. It is important to realise though that left
More information240- PROBLEM SET INSERTION OF SWAN-GANZ SYSTEMIC VASCULAR RESISTANCE. Blood pressure = f(cardiac output and peripheral resistance)
240- PROBLEM SET INSERTION OF SWAN-GANZ 50 kg Pig Rt Jugular 0 cm Rt Atrium 10 cm Rt ventricle 15 cm Wedge 20-25 cm SYSTEMIC VASCULAR RESISTANCE Blood pressure = f(cardiac output and peripheral resistance)
More informationNormal & Abnormal Intracardiac. Lancashire & South Cumbria Cardiac Network
Normal & Abnormal Intracardiac Pressures Lancashire & South Cumbria Cardiac Network Principle Pressures recorded from catheter tip Electrical transducer - wheatstone bridge mechanical to electrical waveform
More informationParkland College RTT 213 Syllabus. Respiratory Therapy VI: Management of the Critically Ill Patient
Parkland College RTT 213 Syllabus Respiratory Therapy VI: Management of the Critically Ill Patient I. Catalog Description RTT 213 Respiratory Therapy VI 3-0-3 Hemodynamic monitoring: cardiovascular anatomy
More informationDirect Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003
Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003 Introduction Direct measurement of arterial blood pressure is obtained via a peripheral
More informationLa valutazione dell emodinamica in corso di insufficienza renale acuta
U.O. Nefrologia, Dialisi, Ipertensione Policlinico S.Orsola-Malpighi Bologna - ITALY La valutazione dell emodinamica in corso di insufficienza renale acuta Elena Mancini, Antonio Santoro La Sindrome Cardio-Renale
More informationLevels of Critical Care for Adult Patients
LEVELS OF CARE 1 Levels of Critical Care for Adult Patients STANDARDS AND GUIDELINES LEVELS OF CARE 2 Intensive Care Society 2009 All rights reserved. No reproduction, copy or transmission of this publication
More informationSection Two: Arterial Pressure Monitoring
Section Two: Arterial Pressure Monitoring Indications An arterial line is indicated for blood pressure monitoring for the patient with any medical or surgical condition that compromises cardiac output,
More informationLeft to Right Shunts and their Calculation. Ghada El Shahed, MD
Left to Right Shunts and their Calculation Ghada El Shahed, MD Professor of Cardiology Ain Shams University Flow through systemic & pulmonary circulations is normally balanced and equal. Two circulations
More informationNORTH WALES CRITICAL CARE NETWORK
NORTH WALES CRITICAL CARE NETWORK LEVELS OF CRITICAL CARE FOR ADULT PATIENTS Throughout the work of the North Wales Critical Care Network reference to Levels of Care for the critically ill are frequently
More informationPhysical Model of the Pulmonary Circulation Designed for Investigation on Cardiac Output Measurement by Means of the Thermodilution Method
Vol. 120 (2011) ACTA PHYSICA POLONICA A No. 4 Optical and Acoustical Methods in Science and Technology Physical Model of the Pulmonary Circulation Designed for Investigation on Cardiac Output Measurement
More informationNormal Intracardiac Pressures. Lancashire & South Cumbria Cardiac Network
Normal Intracardiac Pressures Lancashire & South Cumbria Cardiac Network Principle Pressures recorded from catheter tip Electrical transducer - wheatstone bridge mechanical to electrical waveform display
More information3 rd Russian-Bavarian Conference on Bio-Medical Engineering
3 rd Russian-Bavarian Conference on Bio-Medical Engineering Blood Pressure Estimation based on Pulse Transit Time and Compensation of Vertical Position Dipl.-Inform. Med. Christian Douniama Dipl.-Ing.
More informationOxygenation and Oxygen Therapy Michael Billow, D.O.
Oxygenation and Oxygen Therapy Michael Billow, D.O. The delivery of oxygen to all body tissues is the essence of critical care. Patients in respiratory distress/failure come easily to mind as the ones
More informationOEM MAXNIBP Frequently Asked Questions
Frequently Asked Questions Why does the monitor sometimes inflate the BP cuff, then shortly thereafter reinflate the cuff? How will I know if the monitor is experiencing motion artifact during a measurement?
More informationSymposium 10 Monday, May 21, 2001
5 th World Congress of Echocardiography and Vascular Ultrasound Symposium 10 Monday, May 21, 2001 Feasibility of Transcutaneous Cardiac Output Monitoring Using Continuous Wave Doppler Ultrasound; Ultrasonic
More informationMECHINICAL VENTILATION S. Kache, MD
MECHINICAL VENTILATION S. Kache, MD Spontaneous respiration vs. Mechanical ventilation Natural spontaneous ventilation occurs when the respiratory muscles, diaphragm and intercostal muscles pull on the
More informationUW MEDICINE PATIENT EDUCATION. Aortic Stenosis. What is heart valve disease? What is aortic stenosis?
UW MEDICINE PATIENT EDUCATION Aortic Stenosis Causes, symptoms, diagnosis, and treatment This handout describes aortic stenosis, a narrowing of the aortic valve in your heart. It also explains how this
More informationCardiovascular Physiology
Cardiovascular Physiology Heart Physiology for the heart to work properly contraction and relaxation of chambers must be coordinated cardiac muscle tissue differs from smooth and skeletal muscle tissues
More informationVascular System The heart can be thought of 2 separate pumps from the right ventricle, blood is pumped at a low pressure to the lungs and then back
Vascular System The heart can be thought of 2 separate pumps from the right ventricle, blood is pumped at a low pressure to the lungs and then back to the left atria from the left ventricle, blood is pumped
More informationOxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing*
Oxygenation Chapter 21 Anatomy and Physiology of Breathing Inspiration ~ breathing in Expiration ~ breathing out Ventilation ~ Movement of air in & out of the lungs Respiration ~ exchange of O2 & carbon
More informationMEASURING AND RECORDING BLOOD PRESSURE
MEASURING AND RECORDING BLOOD PRESSURE INTRODUCTION The blood pressure, along with the body temperature, pulse, and respirations, is one of the vital signs. These measurements are used to quickly, easily,
More informationFundamentals of Critical Care: Hemodynamics, Monitoring, Shock
Fundamentals of Critical Care: Hemodynamics, Monitoring, Shock Joshua Goldberg, MD Assistant Professor of Surgery Associate Medical Director, Burn Unit UCHSC Definitions and Principles The measurement
More informationManagement of the Patient with Aortic Stenosis undergoing Non-cardiac Surgery
Management of the Patient with Aortic Stenosis undergoing Non-cardiac Surgery Srinivasan Rajagopal M.D. Assistant Professor Division of Cardiothoracic Anesthesia Objectives Describe the pathophysiology
More informationBASIC STANDARDS FOR RESIDENCY TRAINING IN CARDIOLOGY
BASIC STANDARDS FOR RESIDENCY TRAINING IN CARDIOLOGY American Osteopathic Association and the American College of Osteopathic Internists Specific Requirements For Osteopathic Subspecialty Training In Cardiology
More informationCirculatory System Review
Circulatory System Review 1. Draw a table to describe the similarities and differences between arteries and veins? Anatomy Direction of blood flow: Oxygen concentration: Arteries Thick, elastic smooth
More informationResuscitation in congenital heart disease. Peter C. Laussen MBBS FCICM Department Critical Care Medicine Hospital for Sick Children Toronto
Resuscitation in congenital heart disease Peter C. Laussen MBBS FCICM Department Critical Care Medicine Hospital for Sick Children Toronto Evolution of Congenital Heart Disease Extraordinary success: Overall
More informationAnaerobic and Aerobic Training Adaptations. Chapters 5 & 6
Anaerobic and Aerobic Training Adaptations Chapters 5 & 6 Adaptations to Training Chronic exercise provides stimulus for the systems of the body to change Systems will adapt according to level, intensity,
More informationThe Sepsis Puzzle: Identification, Monitoring and Early Goal Directed Therapy
The Sepsis Puzzle: Identification, Monitoring and Early Goal Directed Therapy Cindy Goodrich RN, MS, CCRN Content Description Sepsis is caused by widespread tissue injury and systemic inflammation resulting
More informationVtial sign #1: PULSE. Vital Signs: Assessment and Interpretation. Factors that influence pulse rate: Importance of Vital Signs
Vital Signs: Assessment and Interpretation Elma I. LeDoux, MD, FACP, FACC Associate Professor of Medicine Vtial sign #1: PULSE Reflects heart rate (resting 60-90/min) Should be strong and regular Use 2
More informationMarch 31, 2016. Etiometry, Inc. Richard Galgon Independent Consulting Associate Quintiles 5846 Cobblestone Lane Waunakee, Wisconsin 53597
DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service March 31, 2016 Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 Etiometry,
More informationHow To Know If A Patient Is Preload Sensitive
The Open Critical Care Medicine Journal, 2010, 3, 33-37 33 Open Access Use of Ultrasound to Assess Fluid Responsiveness in the Intensive Care Unit Moses M. Kitakule * and Paul Mayo * The Division of Pulmonary,
More informationEsophageal Doppler Monitor (EDM) guided individualized goal directed fluid management (igdfm) in surgery - a technical review
Esophageal Doppler Monitor (EDM) guided individualized goal directed fluid management (igdfm) in surgery - a technical review Graham D. Lowe AKC BSc PhD, Barry M. Chamberlain*, Eleanor J. Philpot RGN MSc,
More informationThe EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.
Heart Rate Sensor Heart Rate Sensor (Product No PC-3147) Pulse rate Range: 0 to 200 bpm Resolution: 1 bpm Waveform Range: -2000 to 2000 mv Resolution: 1 mv Introduction The Smart Q Heart Rate Sensor monitors
More informationNew Devices to Monitor Heart Failure and Reduce Hospitalizations
New Devices to Monitor Heart Failure and Reduce Hospitalizations Michael Shochat, BSc, MD, PhD Hillel Yaffe Medical Center, Hadera, affiliated to Technion Israel Institute of Technology, Haifa I, Michael
More informationPulseCO: A Less-Invasive Method to Monitor Cardiac Output From Arterial Pressure After Cardiac Surgery
PulseCO: A Less-Invasive Method to Monitor Cardiac Output From Arterial Pressure After Cardiac Surgery Timothy T. Hamilton, MD, Lynne M. Huber, RN, and Michael E. Jessen, MD The Department of Cardiovascular
More informationCHAPTER THREE COMMON DESCRIPTIVE STATISTICS COMMON DESCRIPTIVE STATISTICS / 13
COMMON DESCRIPTIVE STATISTICS / 13 CHAPTER THREE COMMON DESCRIPTIVE STATISTICS The analysis of data begins with descriptive statistics such as the mean, median, mode, range, standard deviation, variance,
More informationUltrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions
Ultrasound Technologies PD1v vascular pocket doppler Operating Instructions Before using your Pocket Doppler for the first time, please read these operating instructions carefully. 1 INTRODUCTION The UltraTec
More informationMonitoring of Cerebral Blood Flow. Transcranial Doppler Laser Doppler Flowmetry Thermal dilution method (Hemedex)
Monitoring of Cerebral Blood Flow Transcranial Doppler Laser Doppler Flowmetry Thermal dilution method (Hemedex) Ultrasound in Tissue Some Facts: blood cell tissue probe ultrasound travels at a constant
More informationCardiorespiratory Fitness
Cardiorespiratory Fitness Assessment Purpose Determine level of fitness & set goals Develop safe & effective exercise prescription Document improvements Motivation Provide info concerning health status
More informationMilwaukee School of Engineering Gerrits@msoe.edu. Case Study: Factors that Affect Blood Pressure Instructor Version
Case Study: Factors that Affect Blood Pressure Instructor Version Goal This activity (case study and its associated questions) is designed to be a student-centered learning activity relating to the factors
More informationInflammatory or cardiogenic lung edema? It does matter!
Inflammatory or cardiogenic lung edema? It does matter! Dr Xavier MONNET Medical Intensive Care Unit Bicêtre Hospital FRANCE Conflict of interest Inflammatory or cardiogenic lung edema? It does matter!
More informationGRADE 11F: Biology 3. UNIT 11FB.3 9 hours. Human gas exchange system and health. Resources. About this unit. Previous learning.
GRADE 11F: Biology 3 Human gas exchange system and health UNIT 11FB.3 9 hours About this unit This unit is the third of six units on biology for Grade 11 foundation. The unit is designed to guide your
More informationIntroduction Hypothesis Methods Results Conclusions Figure 11-1: Format for scientific abstract preparation
ABSTRACT AND MANUSCRIPT PREPARATION / 69 CHAPTER ELEVEN ABSTRACT AND MANUSCRIPT PREPARATION Once data analysis is complete, the natural progression of medical research is to publish the conclusions of
More informationEvaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS
Blood Pressure Project 9 Blood pressure is a measure of the fluid pressure within the circulatory system. This pressure is required to ensure the delivery of oxygen and nutrients to, and the removal of
More informationScope and Standards for Nurse Anesthesia Practice
Scope and Standards for Nurse Anesthesia Practice Copyright 2013 222 South Prospect Ave. Park Ridge, IL 60068 www.aana.com Scope and Standards for Nurse Anesthesia Practice The AANA Scope and Standards
More informationMagnetic Resonance Quantitative Analysis. MRV MR Flow. Reliable analysis of heart and peripheral arteries in the clinical workflow
Magnetic Resonance Quantitative Analysis MRV MR Flow Reliable analysis of heart and peripheral arteries in the clinical workflow CAAS MRV Functional Workflow Designed for imaging specialists, CAAS MRV
More informationEnhancements on SCP-ECG protocol for multi vital-sign handling
Enhancements on SCP-ECG protocol for multi vital-sign handling G. MANDELLOS, G. KOUTELAKIS, G. TRIANTAFYLLOU, M. KOUKIAS, D. LYMPEROPOULOS Wire Communication Lab, Electrical & Computer Engineering Dept.,
More informationMedical Direction and Practices Board WHITE PAPER
Medical Direction and Practices Board WHITE PAPER Use of Pressors in Pre-Hospital Medicine: Proper Indication and State of the Science Regarding Proper Choice of Pressor BACKGROUND Shock is caused by a
More informationNursing Education and Research
Melissa Meloche Meloche, RN RN, MSN MSN, CCRN Nursing Education and Research Describe the purpose p of common clinical equipment found in the Intensive Care Unit and how this equipment could impact a patient
More informationBergen Community College Division of Health Professions Department of Respiratory Therapy RSP 240 Diagnostic Monitoring and Patient Assessment
Date Revised: August 2014 Semester and Year: Fall 2014 Bergen Community College Division of Health Professions Department of Respiratory Therapy RSP 240 Diagnostic Monitoring and Patient Assessment Course
More informationHEART HEALTH WEEK 3 SUPPLEMENT. A Beginner s Guide to Cardiovascular Disease HEART FAILURE. Relatively mild, symptoms with intense exercise
WEEK 3 SUPPLEMENT HEART HEALTH A Beginner s Guide to Cardiovascular Disease HEART FAILURE Heart failure can be defined as the failing (insufficiency) of the heart as a mechanical pump due to either acute
More informationPulse Oximetry. Principles of oximetry
Pulse Oximetry The principal advantage of optical sensors for medical applications is their intrinsic safety since there is no electrical contact between the patient and the equipment. (An added bonus
More informationLaerdal Patient Monitor Help Page 1 June 14, 2012, Rev E
Laerdal Patient Monitor Help Page 1 Using the Laerdal Patient Monitor The Laerdal Patient Monitor software is used to simulate a typical Patient Monitor found in hospitals and ambulances. It is made available
More informationCorporate Medical Policy
Corporate Medical Policy Cardiac Hemodynamic Monitoring in the Outpatient Setting File Name: Origination: Last CAP Review: Next CAP Review: Last Review: cardiac_hemodynamic_monitoring_in_the_outpatient_setting
More informationCommon Ventilator Management Issues
Common Ventilator Management Issues William Janssen, M.D. Assistant Professor of Medicine National Jewish Health University of Colorado Denver Health Sciences Center You have just admitted a 28 year-old
More informationRome 2009. Disclosure. The speaker cooperates with the following companies. BMeye Drager-Siemens Pulsion. perelao@shani.net
HOW TO PRACTICALLY USE THE VARIOUS MONITORING SYSTEMS? The PiCCO system Azriel Perel Professor and Chairman Department of Anesthesiology and Intensive Care Sheba Medical Center, Tel Aviv University Israel
More informationBlood Pressure. Blood Pressure (mm Hg) pressure exerted by blood against arterial walls. Blood Pressure. Blood Pressure
Blood Pressure Blood Pressure (mm Hg) pressure exerted by blood against arterial walls Systolic pressure exerted on arteries during systole Diastolic pressure in arteries during diastole 120/80 Borderline
More informationAnatomi & Fysiologi 060301. The cardiovascular system (chapter 20) The circulation system transports; What the heart can do;
The cardiovascular system consists of; The cardiovascular system (chapter 20) Principles of Anatomy & Physiology 2009 Blood 2 separate pumps (heart) Many blood vessels with varying diameter and elasticity
More informationElectrocardiography I Laboratory
Introduction The body relies on the heart to circulate blood throughout the body. The heart is responsible for pumping oxygenated blood from the lungs out to the body through the arteries and also circulating
More informationCRITICAL CARE MONITORING: WHAT, WHEN, AND HOW? Susan G. Hackner, BVSc.MRCVS.DACVIM.DACVECC.
CRITICAL CARE MONITORING: WHAT, WHEN, AND HOW? Susan G. Hackner, BVSc.MRCVS.DACVIM.DACVECC. A crucial goal in the critical patient is the maintenance and optimization of cellular (and organ) health. Cellular
More informationPULMONARY PHYSIOLOGY
I. Lung volumes PULMONARY PHYSIOLOGY American College of Surgeons SCC Review Course Christopher P. Michetti, MD, FACS and Forrest O. Moore, MD, FACS A. Tidal volume (TV) is the volume of air entering and
More informationDescribing Sound Waves. Period. Frequency. Parameters used to completely characterize a sound wave. Chapter 3. Period Frequency Amplitude Power
Parameters used to completely characterize a sound wave Describing Sound Waves Chapter 3 Period Frequency Amplitude Power Intensity Speed Wave Length Period Defined as the time it take one wave vibrate
More informationFrom AARC Protocol Committee; Subcommittee Adult Critical Care Version 1.0a (Sept., 2003), Subcommittee Chair, Susan P. Pilbeam
AARC - ADULT MECHANICAL VENTILATOR PROTOCOLS 1. Guidelines for Using Ventilator Protocols 2. Definition of Modes and Suggestions for Use of Modes 3. Adult Respiratory Ventilator Protocol - Guidelines for
More information1.4.4 Oxyhemoglobin desaturation
Critical Care Therapy and Respiratory Care Section Category: Clinical Section: Clinical Monitoring Title: Monitoring of Patients Undergoing Conscious Sedation Policy #: 09 Revised: 05/00 1.0 DESCRIPTION
More informationTCD in Intensive Care
TCD in Intensive Care Background: Transcranial Doppler (TCD) ultrasonography is a technique that uses a hand-held Doppler transducer (placed on the surface of the cranial skin) to measure the velocity
More informationMichael R. Pinsky, M.D., C.M., Dr.h.c., FCCP, MCCM Professor of Critical Care Medicine, Bioengineering, Anesthesiology, Cardiovascular Diseases, and
Michael R. Pinsky, M.D., C.M., Dr.h.c., FCCP, MCCM Professor of Critical Care Medicine, Bioengineering, Anesthesiology, Cardiovascular Diseases, and Clinical & Translational Sciences, Vice Chair for Academic
More informationTRANSPORT OF CRITICALLY ILL PATIENTS
TRANSPORT OF CRITICALLY ILL PATIENTS Introduction Inter-hospital and intra-hospital transport of critically ill patients places the patient at risk of adverse events and increased morbidity and mortality.
More informationPolicies and Procedures. Related to. IABP Therapy
Policies and Procedures Related to IABP Therapy Courtesy of Datascope Corp. Clinical Support Services The following policies and procedures are intended to serve as guidelines for developing hospital policy.
More informationGENERAL EQUATION FOR SPIROMETRY CALCULATION OF VO 2 VO 2(ml O2/min) = (V I (ml O2/min STPD) * F I O 2 ) (V E(ml O2/min STPD) *F E O 2 )
Exercise Testing and Prescription Lab Metabolic Calculation Lab Use Appendix D, lecture materials, and the conversions below to help you complete this lab. This lab is for purposes of practicing metabolic
More informationLab #11: Respiratory Physiology
Lab #11: Respiratory Physiology Background The respiratory system enables the exchange of O 2 and CO 2 between the cells and the atmosphere, thus enabling the intake of O 2 into the body for aerobic respiration
More informationCarbon Dioxide and an Argon + Nitrogen Mixture. Measurement of C p /C v for Argon, Nitrogen, Stephen Lucas 05/11/10
Carbon Dioxide and an Argon + Nitrogen Mixture Measurement of C p /C v for Argon, Nitrogen, Stephen Lucas 05/11/10 Measurement of C p /C v for Argon, Nitrogen, Carbon Dioxide and an Argon + Nitrogen Mixture
More informationNew Cardiothoracic Surgery CPT Codes for 2013
New Cardiothoracic Surgery CPT Codes for 2013 There were several changes to the cardiothoracic surgery CPT codes for 2013. There are five new codes in the general thoracic surgery section, with one revised
More informationSpirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display
Spirodoc 3D Laboratory for respiratory analysis two functional modes: doctor and patient Four devices in one Spirometer with Touch Screen display Pulse Oximeter intelligent with on screen results 3D Accelerometer
More informationPulmonary Diseases. Lung Disease: Pathophysiology, Medical and Exercise Programming. Overview of Pathophysiology
Lung Disease: Pathophysiology, Medical and Exercise Programming Overview of Pathophysiology Ventilatory Impairments Increased airway resistance Reduced compliance Increased work of breathing Ventilatory
More informationChristopher M. Wright, MD, MBA Pioneer Cardiovascular Consultants Tempe, Arizona
Christopher M. Wright, MD, MBA Pioneer Cardiovascular Consultants Tempe, Arizona Areas to be covered Historical, current, and future treatments for various cardiovascular disease: Atherosclerosis (Coronary
More informationLaminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers
Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic
More informationVascular Technology (VT) Content Outline Anatomy & physiology 20% Cerebrovascular Cerebrovascular normal anatomy Evaluate the cerebrovascular vessels
Vascular Technology (VT) Content Outline Anatomy & physiology 20% normal anatomy Evaluate the cerebrovascular vessels hemodynamics Evaluate the cerebrovascular vessels for normal perfusion normal anatomy
More informationSensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care
Sensors / Modules / Monitors Breath Gas Sensing and Monitoring For life supporting systems in intensive, emergency and ambulant care Your competent partner for breath gas sensing and monitoring EnviteC
More informationForced vital capacity: maximal volume of air exhaled with maximally forced effort from a maximal inspiration.
SOP Spirometry 1. General considerations Spirometry serves as a physiological test to quantify pulmonary disease severity and to assess clinical change in respiratory function over time. Standard spirometric
More informationCPT Pediatric Coding Updates 2009. The 2009 Current Procedural Terminology (CPT) codes are effective as of January 1, 2009.
CPT Pediatric Coding Updates 2009 The 2009 Current Procedural Terminology (CPT) codes are effective as of January 1, 2009. NEW CODES Evaluation and Management Services Normal Newborn Care Codes 99431-99440
More informationPredicting Aerobic Power (VO 2max ) Using The 1-Mile Walk Test
USING A WALKING TEST 12/25/05 PAGE 1 Predicting Aerobic Power (VO 2max ) Using The 1-Mile Walk Test KEYWORDS 1. Predict VO 2max 2. Rockport 1-mile walk test 3. Self-paced test 4. L min -1 5. ml kg -1 1min
More information