Spring Cage Feed-Through Terminal Blocks ST



Similar documents
PC 4/ 5-STF-7,62. Extract from the online catalog. Order No.:

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.:

Feed-through terminal block - SSK 110 KER-EX

GMKDS 3/ 3-7,62. Extract from the online catalog. Order No.:

The range of rail-mounted terminal blocks. for a perfect electrical installation.

PCB TERMINAL BLOCKS. Product Overview

Redundancy Module QUINT-DIODE/40

MINI MCR-SL-R-UI(-SP)

SMD Terminal Blocks with Push-Buttons

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Electronic housing BC for distributor boards

Block width on rail (mm) Standard block* is shown on blue background

PHOENIX CONTACT Features

ZS10 Screw Clamp Terminal Block

Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs

HARTING Ethernet Cabling 8-poles Overview

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

picomax The Pluggable Connection System

Feed-through terminals

HARTING Ethernet Cabling 4-poles Overview

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Digital input modules

VARIOSUB RJ45/IP20 Plug Connectors

Powermate Range Pitch 7.62

ZS25 Screw Clamp Terminal Blocks Feed-through

Product and functional description

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

The Rail-Mounted Terminal Block System

Analog signal converters CC-E I/I Current / current isolators

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

48 SERIES Relay interface modules 10 A

Automation Solutions. LÜTZE LCOS empty housing for Industrial Automation

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Safety technique. Emergency stop module BO 5988 safemaster

Terminals, W-Series. Contents. Terminals, W-Series. Terminals, W-Series. Terminals, TS 15. Stud terminals. Accessories. Terminals, SAK-Series E.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

49 Series - Relay interface modules A. Features

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

HARTING Ethernet Cabling 4-poles Overview

FASTON Terminals and Connectors

Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059?

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

Cables and Accessories Selection Guide

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet _en_02. 1 Description

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 Series - Relay interface modules A

Type: DILM50(230V50HZ,240V60HZ) Article No.:

SMD TERMINAL BLOCKS. Small is Big!

MasterINTERFACE 39 Series - Relay interface modules

Connecting the Channel A

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Directory chapter 04

Jumper bar BJM. Assembled jumper bar BJD. Assembled jumper bar

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

Modular Terminal Blocks

HARAX circular connector

Industrial circular connectors

MasterINTERFACE 39 Series - Relay interface modules

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

General Purpose Relays Accessories. Accessories Miniature Relay PT

Product Overview. AC 166 The Economic Solution for Electrical Installation

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

TX OPEN RS232/485 module

AMPSEAL* Automotive Plug Connector and Header Assembly

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

High Power Connectors for Power Supply and Power Circuits

Intersection Preassembled 19-inch Rack

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

80 Series - Modular timers 16 A. Features

IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.2 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack.

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

ODU MINI-SNAP. Miniature Cylindrical Connectors with Push-Pull-Locking Series F

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Product Information. HMC 6 Hybrid Motor Cable

SURGE PROTECTIVE DEVICES

Transcription:

Spring Cage Feed-Through Terminal Blocks ST The product family ST with the new spring cage system "mini spring" is extremely space-saving. Space is saved thanks to a clearly smaller spring system without having to give up such familiar quality features as the large insertion space. The outstanding feature of the feed-through terminals is their space-saving design, the generous labeling options and a flexible bridging system. The insertion space of the ST terminal blocks is designed in such a way that flexible conductors with the rated cross section with ferrule can also be wired up without difficulty. The ground terminal blocks with the same shape as the feed-through terminal blocks make contact via simple snapping on the mounting rail and thus take over the ground conductor function. The housings are made of unbreakable polyamide 6.6 of the inflammability class acc. to UL 94. Marking A clear assignment of the connection lines is a prerequisite for unambiguous and correct installation of terminal strips. The ST series is ideally suited to these requirements. The generous labeling option using ZB standard Zack ("quick") strip in the terminal center is always easily accessible and readily recognizable, even when wired. Moreover, each termination point can also be labeled for special applications. available in the number of position 2, 3, 4, 5 and 10. 20-pos. bridges can also be delivered for the 4, 5 and 6 mm terminal block pitches which can be cut to suit your requirements. There is also the possibility of a practical test connection in the bridge shaft of the terminal block. Generous wire entrance The ST series has large conductor openings, which eliminate the need to move up to a large terminal block when ferrules are required. Plug-in bridging system FBS The ST terminal block has dual channels for handling all types of bridging possibilities. By means of plug-in bridges the chain bridging can be achieved either with a 2-pos. standard jumper or with multi-position bridges. The multi-position version is especially useful for fast bridging of multi-position terminal strips. The bridging between non-adjacent terminals can also be handled with this version. The plug-in bridges are Phoenix Contact GmbH & Co. KG 32823 Blomberg, Germany Phone +49 52 35 3-00 Fax +49 52 35 3-4 12 00 www.phoenixcontact.com

Feed-Through Terminal Block ST 1,5 (IEC) rigid flexible I U [mm 2 ] solid stranded AWG [A] [V] IEC 60 947-7-1 0.08-1.5 0.08-1.5 28-16 17.5 500 EN 50 019* 0.08-1.5 0.08-1.5 28-16 17.5 420 * EC Prototype certificate no.: KEMA 01ATEX2129U for mounting on 3 gray terminal width 4.2 blue terminal width 4.2 orange terminal width 4.2 red terminal width 4.2 black terminal width 4.2 ST 1,5 30 31 07 6 50 ST 1,5 BU 30 31 08 9 50 ST 1,5 OG 30 37 01 2 50 ST 1,5 RD 30 37 03 8 50 ST 1,5 BK 30 37 06 7 50 (1) End cover gray D-ST 2,5 30 30 41 7 50 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm 2 white 0.25-0.5 mm 2 gray (3) Plug-in bridge, for 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. ISH 1,5/0,2 32 06 13 1 50 ISH 1,5/0,5 30 31 03 4 50 FBS 2-4 I max. : 17.5 A 30 30 11 6 50 FBS 3-4 17.5 A 30 30 12 9 50 FBS 4-4 17.5 A 30 30 13 2 50 FBS 5-4 17.5 A 30 30 14 5 50 FBS 10-4 17.5 A 30 30 15 8 10 FBS 20-4 17.5 A 30 30 35 2 10 (4) Partition plate, for visual and electrical separation ATP-ST 4 30 30 72 1 50 of terminal groups, 2 mm thick (5) Test adapter, for 4 mm test connector PS and 4 mm safety test connectors, I 4 30 30 92 5 10 making contact in the bridge shaft (6) Modular test connector, for individual assembly of test connector strips, PS-4 30 30 97 0 10 can be labeled with ZBF 4 (7) Warning cover, for the operating shafts of the mini-spring WST 1,5 30 30 95 8 10 ST spring cage terminal blocks (8) Screwdriver, for actuating the tension spring SZF 0-0,4 x 2,5 12 04 50 4 10 (9) Zack strip, flat, for labeling the outer marker grooves white ZBF 4:UNPRINTED 08 08 58 7 10 (10) Zack strip, 10-section, for labeling in the white ZB 4:UNPRINTED 08 05 00 1 10 Width / length / end cover width [mm] 4.2 / 48.5 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44 Maximum load current / cross section [A] / [mm 2 ] 17.5 / 1.5 Rated surge voltage / contamination class [kv] / 6 / 3 Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-1.5 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-1.5 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 0.5 Stripping length [mm] 10 Internal cylindrical gauge (IEC 60 947-1) A 1 Phoenix Contact page 2 of 15

Ground Terminal Block ST 1,5-PE (IEC) rigid flexible [mm 2 ] solid stranded AWG IEC 60 947-7-2 0.08-1.5 0.08-1.5 28-16 EN 50 019* 0.08-1.5 0.08-1.5 28-16 * EC Prototype certificate no.: KEMA 01ATEX2129U Observe the current carrying capacity of mounting rails. for mounting on 3 green-yellow terminal width 4.2 ST 1,5-PE 30 31 51 3 50 (1) End cover gray D-ST 2,5 30 30 41 7 50 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm 2 white 0.25-0.5 mm 2 gray ISH 1,5/0,2 32 06 13 1 50 ISH 1,5/0,5 30 31 03 4 50 (3) Screwdriver, for actuating the tension spring SZF 0-0,4 x 2,5 12 04 50 4 10 (4) Zack strip, flat, for labeling the outer marker grooves white ZBF 4:UNPRINTED 08 08 58 7 10 (5) Zack strip, 10-section, for labeling in the white ZB 4:UNPRINTED 08 05 00 1 10 Width / length / end cover width [mm] 4.2 / 48.5 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44 Maximum load current / cross section [A] / [mm 2 ] Rated surge voltage / contamination class [kv] / 6 / 3 Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-1.5 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-1.5 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 0.5 Stripping length [mm] 10 Internal cylindrical gauge (IEC 60 947-1) A 1 Phoenix Contact page 3 of 15

Feed-Through Terminal Block ST 2,5 (IEC) rigid flexible I U [mm 2 ] solid stranded AWG [A] [V] IEC 60 947-7-1 0.08-4 0.08-2.5 28-12 31 800 EN 50 019* 0.08-4 0.08-2.5 28-12 25/21 550 * EC Prototype certificate no.: KEMA 00ATEX2052U for mounting on 3 gray terminal width 5.2 blue terminal width 5.2 orange terminal width 5.2 red terminal width 5.2 black terminal width 5.2 ST 2,5 30 31 21 2 50 ST 2,5 BU 30 31 22 5 50 ST 2,5 OG 30 37 07 0 50 ST 2,5 RD 30 37 09 6 50 ST 2,5 BK 30 37 12 2 50 (1) End cover gray D-ST 2,5 30 30 41 7 50 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm 2 white 0.25-0.5 mm 2 gray 0.75-1 mm 2 black (3) Plug-in bridge, for 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. ISH 2,5/0,2 30 02 84 3 50 ISH 2,5/0,5 30 02 85 6 50 ISH 2,5/1 30 02 86 9 50 FBS 2-5 I max. : 24 A 30 30 16 1 50 FBS 3-5 24 A 30 30 17 4 50 FBS 4-5 24 A 30 30 18 7 50 FBS 5-5 24 A 30 30 19 0 50 FBS 10-5 24 A 30 30 21 3 10 FBS 20-5 24 A 30 30 22 6 10 (4) Partition plate, for visual and electrical separation ATP-ST 4 30 30 72 1 50 of terminal groups, 2 mm thick (5) Test adapter, for 4 mm test connector PS and 4 mm safety test connectors, I 4 30 30 92 5 10 making contact in the bridge shaft (6) 2.3 mm test connector 1 ), consisting of MPS-RD 02 01 55 3 10 metal part and red insulating sleeve (7) Modular test connector, can be labeled with ZBF 5 PS 5 30 30 98 3 10 (8) Warning cover, for the operating shafts of the mini-spring WST 2,5 30 30 94 1 10 ST spring cage terminal blocks (9) Screwdriver, for actuating the tension spring SZF 1-0,6 x 3,5 12 04 51 7 10 (10) Zack strip, flat, for labeling the outer marker grooves white ZBF 5 :UNPRINTED 08 08 64 2 10 (11) Zack strip, 10-section, for labeling in the white ZB 5:UNPRINTED 10 50 00 4 10 Width / length / end cover width [mm] 5.2 / 48.5 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44 Maximum load current / cross section [A] / [mm 2 ] 31 / 4 Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-2.5 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-2.5 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 0.5 Stripping length [mm] 10 Internal cylindrical gauge (IEC 60 947-1) A 3 Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG 600 / 20 / 26-12 CSA/CUL: [V] / [A] / AWG 600 / 20 / 26-12 1) Further colors on request. Phoenix Contact page 4 of 15

Ground Terminal Block ST 2,5-PE (IEC) rigid flexible [mm 2 ] solid stranded AWG IEC 60 947-7-2 0.08-4 0.08-2.5 28-12 EN 50 019* 0.08-4 0.08-2.5 28-12 * EC Prototype certificate no.: KEMA 00ATEX2052U Observe the current carrying capacity of mounting rails. for mounting on 3 green-yellow terminal width 5.2 ST 2,5-PE 30 31 23 8 50 (1) End cover gray D-ST 2,5 30 30 41 7 50 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm 2 white 0.25-0.5 mm 2 gray 0.75-1 mm 2 black ISH 2,5/0,2 30 02 84 3 50 ISH 2,5/0,5 30 02 85 6 50 ISH 2,5/1 30 02 86 9 50 (3) Screwdriver, for actuating the tension spring SZF 1-0,6 x 3,5 12 04 51 7 10 (4) Zack strip, flat, for labeling the outer marker grooves white ZBF 5 :UNPRINTED 08 08 64 2 10 (5) Zack strip, 10-section, for labeling in the white ZB 5:UNPRINTED 10 50 00 4 10 Width / length / end cover width [mm] 5.2 / 48.5 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44 Maximum load current / cross section [A] / [mm 2 ] Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-2.5 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-2.5 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 0.5 Stripping length [mm] 10 Internal cylindrical gauge (IEC 60 947-1) A 3 / / 26-12 / / 26-12 Phoenix Contact page 5 of 15

Feed-Through Terminal Block ST 4 (IEC) rigid flexible I U [mm 2 ] solid stranded AWG [A] [V] IEC 60 947-7-1 0.08-6 0.08-4 28-10 40 800 EN 50 019* 0.08-6 0.08-4 28-10 34/30 550 * EC Prototype certificate no.: KEMA 00ATEX2129U for mounting on 3 gray terminal width 6.2 blue terminal width 6.2 orange terminal width 6.2 red terminal width 6.2 black terminal width 6.2 ST 4 30 31 36 4 50 ST 4 BU 30 31 37 7 50 ST 4 OG 30 37 13 5 50 ST 4 RD 30 37 15 1 50 ST 4 BK 30 37 18 0 50 (1) End cover gray D-ST 4 30 30 42 0 50 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.25-0.5 mm 2 gray 0.75-1 mm 2 black (3) Plug-in bridge, for 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. ISH 4/0,5 30 02 88 5 50 ISH 4/1 30 02 89 8 50 FBS 2-6 I max. : 32 A 30 30 33 6 50 FBS 3-6 32 A 30 30 24 2 50 FBS 4-6 32 A 30 30 25 5 50 FBS 5-6 32 A 30 30 34 9 50 FBS 10-6 32 A 30 30 27 1 10 FBS 20-6 32 A 30 30 36 5 10 (4) Partition plate, for visual and electrical separation ATP-ST 4 30 30 72 1 50 of terminal groups, 2 mm thick (5) Test adapter, for 4 mm test connector PS and 4 mm safety test connectors, I 4 30 30 92 5 10 making contact in the bridge shaft (6) 2.3 mm test connector 1 ), consisting of MPS-RD 02 01 55 3 10 metal part and red insulating sleeve (7) Modular test connector, can be labeled with ZBF 6 PS-6 30 30 99 6 10 (8) Warning cover, for the operating shafts of the mini-spring WST 4 30 30 95 4 10 ST spring cage terminal blocks (9) Screwdriver, for actuating the tension spring SZF 1-0,6 x 3,5 12 04 51 7 10 (10) Zack strip, flat, for labeling the outer marker grooves white ZBF 6:UNPRINTED 08 08 71 0 10 (11) Zack strip, 10-section, for labeling in the white ZB 6:UNPRINTED 10 51 00 3 10 Width / length / end cover width [mm] 6.2 / 56 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44 Maximum load current / cross section [A] / [mm 2 ] 40 / 6 Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-4 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-4 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 0.5-1 Stripping length [mm] 10 Internal cylindrical gauge (IEC 60 947-1) A 4 Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG 600 / 30 / 20-10 CSA/CUL: [V] / [A] / AWG 600 / 30 / 20-10 1) Further colors on request. Phoenix Contact page 6 of 15

Ground Terminal Block ST 4-PE (IEC) rigid flexible [mm 2 ] solid stranded AWG IEC 60 947-7-2 0.08-6 0.08-4 28-10 EN 50 019* 0.08-6 0.08-4 28-10 * EC Prototype certificate no.: KEMA 00ATEX2129U Observe the current carrying capacity of mounting rails. for mounting on 3 green-yellow terminal width 6.2 ST 4-PE 30 31 38 0 50 (1) End cover gray D-ST 4 30 30 42 0 50 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.25-0.5 mm 2 gray 0.75-1 mm 2 black ISH 4/0,5 30 02 88 5 50 ISH 4/1 30 02 89 8 50 (3) Screwdriver, for actuating the tension spring SZF 1-0,6 x 3,5 12 04 51 7 10 (4) Zack strip, flat, for labeling the outer marker grooves white ZBF 6:UNPRINTED 08 08 71 0 10 (5) Zack strip, 10-section, for labeling in the white ZB 6:UNPRINTED 10 51 00 3 10 Width / length / end cover width [mm] 6.2 / 56 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44 Maximum load current / cross section [A] / [mm 2 ] Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-4 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-4 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 0.5-1 Stripping length [mm] 10 Internal cylindrical gauge (IEC 60 947-1) A 4 / / 20-10 / / 20-10 Phoenix Contact page 7 of 15

Feed-Through Terminal Block ST 6 (IEC) rigid flexible I U [mm 2 ] solid stranded AWG [A] [V] IEC 60 947-7-1 0.2-10 0.2-6 24-8 52 800 EN 50 019* 0.2-10 0.2-6 24-8 45/36 550 * EC Prototype certificate no: KEMA 00ATEX2129U for mounting on 3 gray terminal width 8.2 blue terminal width 8.2 ST 6 30 31 48 7 50 ST 6 BU 30 31 49 0 50 (1) End cover gray D-ST 6 30 30 43 3 50 (2) Plug-in bridge, for 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. FBS 2-8 I max. : 41 A 30 30 28 4 10 FBS 3-8 41 A 30 30 29 7 10 FBS 4-8 41 A 30 30 30 7 10 FBS 5-8 41 A 30 30 31 0 10 FBS 10-8 41 A 30 30 32 3 10 (3) Reducing bridge, for connection of one ST 6 with ST 2,5 or ST 4 RB ST 6-(2,5/4) I max. : 48 A 30 30 86 0 10 (4) Partition plate, for visual and electrical separation ATP-ST 6 30 24 48 1 50 of terminal groups, 2 mm thick (5) Test adapter, for 4 mm test connector PS and 4 mm safety test connectors, I 4 30 30 92 5 10 making contact in the bridge shaft (6) 2.3 mm test connector 1 ), consisting of MPS-RD 02 01 55 3 10 metal part and red insulating sleeve (7) Modular test connector, can be labeled with ZBF 8 PS 8 30 31 00 5 10 (8) Warning cover, for the operating shafts of the mini-spring WST 6 30 30 96 7 10 ST spring cage terminal blocks (9) Screwdriver, for actuating the tension spring SZF 2-0,8 x 4,0 12 04 52 0 10 (10) Zack marker sheet, flat, (11) Zack strip, 10-section, for labeling in the white ZB 8:UNPRINTED 10 52 00 2 10 Width / length / end cover width [mm] 8.2 / 69.5 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 43.5 / 51 Maximum load current / cross section [A] / [mm 2 ] 52 / 10 Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-6 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-6 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 0.5-1.5 Stripping length [mm] 12 Internal cylindrical gauge (IEC 60 947-1) A 5 Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG 600 / 50 / 20-8 CSA/CUL: [V] / [A] / AWG 600 / 50 / 20-8 1) Further colors on request. Phoenix Contact page 8 of 15

Ground Terminal Block ST 6-PE (IEC) rigid flexible [mm 2 ] solid stranded AWG IEC 60 947-7-2 0.2-10 0.2-6 24-8 EN 50 019* 0.2-10 0.2-6 24-8 * EC Prototype certificate no.: KEMA 00ATEX2129U Observe the current carrying capacity of mounting rails. for mounting on 3 green-yellow terminal width 8.2 ST 6-PE 30 31 50 0 50 (1) End cover gray D-ST 6 30 30 43 3 50 (2) Screwdriver, for actuating the tension spring SZF 2-0,8 x 4,0 12 04 52 0 10 (3) Zack marker sheet, flat, (4) Zack strip, 10-section, for labeling in the white ZB 8:UNPRINTED 10 52 00 2 10 Width / length / end cover width [mm] 8.2 / 69.5 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 43.5 / 51 Maximum load current / cross section [A] / [mm 2 ] Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-6 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-6 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 0.5-1.5 Stripping length [mm] 12 Internal cylindrical gauge (IEC 60 947-1) A 5 / / 20-8 / / 20-8 Phoenix Contact page 9 of 15

Feed-Through Terminal Block ST 10 (IEC) rigid flexible I U [mm 2 ] solid stranded AWG [A] [V] IEC 60 947-7-1 0.2-16 0.2-10 24-6 65 800 EC Prototype certificate from 3rd quarter 2002. for mounting on 3 gray terminal width 10.2 blue terminal width 10.2 ST 10 30 36 11 0 50 ST 10 BU 30 36 12 3 50 (1) End cover gray D-ST 10 30 36 64 4 50 (2) Plug-in bridge, for 2-pos. FBS 2-10 I max. : 57 A 30 05 94 7 10 (3) Reducing bridge, for connection of one ST 10 with ST 2,5 or ST 4 RB ST 10-(2,5/4) I max. : 55 A 30 30 87 3 10 (4) 2.3 mm test connector 1 ), consisting of metal part and red insulating sleeve MPS-RD 02 01 55 3 10 (5) Warning cover, for the operating shafts of the mini-spring WAZ 10 08 07 99 9 25 ST spring cage terminal blocks (6) Screwdriver, for actuating the tension spring SZF 3-1,0 x 5,5 12 06 61 2 10 (7) Zack marker sheet, flat, (8) Zack strip, 10-section, for labeling in the white ZB 10:UNPRINTED 10 53 00 1 10 Width / length / end cover width [mm] 10 / 71.5 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 50.5 / 58 Maximum load current / cross section [A] / [mm 2 ] 65 / 16 Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-10 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-10 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 1.5-2.5 Stripping length [mm] 18 Internal cylindrical gauge (IEC 60 947-1) A 6 1) Further colors on request. Phoenix Contact page 10 of 15

Ground Terminal Block ST 10-PE (IEC) rigid flexible I [mm 2 ] solid stranded AWG [A] IEC 60 947-7-2 0.2-16 0.2-10 16-6 65 Observe the current carrying capacity of mounting rails. EC Prototype certificate from 3rd quarter 2002. for mounting on 3 green-yellow terminal width 10.2 ST 10-PE 30 36 13 6 50 (1) End cover gray D-ST 10 30 36 64 4 50 (2) Plug-in bridge, for cross connection in the 2-pos. FBS 2-10 I max. : 57 A 30 05 94 7 10 (3) Screwdriver, for actuating the tension spring SZF 3-1,0 x 5,5 12 06 61 2 10 (4) Zack marker sheet, flat, (5) Zack strip, 10-section, for labeling in the white ZB 10:UNPRINTED 10 53 00 1 10 Width / length / end cover width [mm] 10 / 71.5 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 50.5 / 58 Maximum load current / cross section [A] / [mm 2 ] 65 / 16 Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-10 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-10 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 1.5-2.5 Stripping length [mm] 18 Internal cylindrical gauge (IEC 60 947-1) A 6 Phoenix Contact page 11 of 15

Feed-Through Terminal Block ST 16 (IEC) rigid flexible I U [mm 2 ] solid stranded AWG [A] [V] IEC 60 947-7-1 0.2-25 0.2-16 24-4 90 800 EC Prototype certificate from 3rd quarter 2002. for mounting on 3 gray terminal width 12 blue terminal width 12 ST 16 30 36 14 9 50 ST 16 BU 30 36 15 2 50 (1) End cover gray D-ST 16 30 36 65 7 50 (2) Plug-in bridge, for 2-pos. FBS 2-12 I max. : 76 A 30 05 95 0 10 (3) Reducing bridge, for connection of one ST 16 with ST 2,5 or ST 4 RB ST 16-(2,5/4) I max. : 63 A 30 30 88 6 10 (4) 2.3 mm test connector 1 ), consisting of metal part and red insulating sleeve MPS-RD 02 01 55 3 10 (5) Warning cover, for the operating shafts of the mini-spring WAZ 12 08 07 98 6 25 ST spring cage terminal blocks (6) Screwdriver, for actuating the tension spring SZF 3-1,0 x 5,5 12 06 61 2 10 (7) Zack marker sheet, flat, (8) Zack strip, 10-section, for labeling in the white ZB 10:UNPRINTED 10 53 00 1 10 Width / length / end cover width [mm] 12 / 80 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 51 / 58.5 Maximum load current / cross section [A] / [mm 2 ] 90 / 25 Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-16 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-16 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 1.5-4 Stripping length [mm] 18 Internal cylindrical gauge (IEC 60 947-1) A 7 1) Further colors on request. Phoenix Contact page 12 of 15

Ground Terminal Block ST 16-PE (IEC) rigid flexible I [mm 2 ] solid stranded AWG [A] IEC 60 947-7-2 0.2-25 0.2-16 24-4 90 Observe the current carrying capacity of mounting rails. EC Prototype certificate from 3rd quarter 2002. for mounting on 3 green-yellow terminal width 12 ST 16-PE 30 36 16 5 25 (1) End cover gray D-ST 16 30 36 65 7 50 (2) Plug-in bridge, for 2-pos. FBS 2-12 I max. : 76 A 30 05 95 0 10 (3) Screwdriver, for actuating the tension spring SZF 3-1,0 x 5,5 12 06 61 2 10 (4) Zack marker sheet, flat, (5) Zack strip, 10-section, for labeling in the white ZB 10:UNPRINTED 10 53 00 1 10 Width / length / end cover width [mm] 12 / 80 / 2.2 Height (NS 35/7.5 / NS 35/15) [mm] 51 / 58.5 Maximum load current / cross section [A] / [mm 2 ] 90 / 25 Stranded with ferrule with plastic sleeve [mm 2 ] 0.25-16 Stranded with ferrule without plastic sleeve [mm 2 ] 0.25-16 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] 1.5-4 Stripping length [mm] 18 Internal cylindrical gauge (IEC 60 947-1) A 7 Phoenix Contact page 13 of 15

Feed-Through Terminal Block ST 35 (IEC) rigid flexible I U [mm 2 ] solid stranded AWG [A] [V] IEC 60 947-7-1 2.5-35 2.5-35 14-2 125 800 EC Prototype certificate from 3rd quarter 2002. for mounting on 3 gray terminal width 16 blue terminal width 16 (1) Plug-in bridge, for 2-pos. ST 35 30 36 17 8 10 ST 35 BU 30 36 18 1 10 FBS 2-16 I max. : 101 A 30 05 96 3 10 (2) Reducing bridge, for connection of one ST 35 with ST 2,5 or ST 4 RB ST 35-(2,5/4) I max. : 63 A 30 30 89 9 10 (3) 2.3 mm test connector 1 ), consisting of metal part and red insulating sleeve MPS-RD 02 01 55 3 10 (4) Warning cover, for the operating shafts of the mini-spring WAZ 16 08 07 97 3 10 ST spring cage terminal blocks (5) Screwdriver, for actuating the tension spring SZF 3-1,0 x 5,5 12 06 61 2 10 (6) Zack marker sheet, flat, (7) Zack strip, 10-section, for labeling in the white ZB 10:UNPRINTED 10 53 00 1 10 Width / length / end cover width [mm] 16 / 80 / Height (NS 35/7,5 / NS 35/15) [mm] 59 / 66.5 Maximum load current / cross section [A] / [mm 2 ] 125 / 35 Stranded with ferrule with plastic sleeve [mm 2 ] 2.5-35 Stranded with ferrule without plastic sleeve [mm 2 ] 2.5-35 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] Stripping length [mm] 25 Internal cylindrical gauge (IEC 60 947-1) A 8 1) Further colors on request. Phoenix Contact page 14 of 15

Ground Terminal Block ST 35-PE (IEC) rigid flexible I [mm 2 ] solid stranded AWG [A] IEC 60 947-7-2 2.5-35 2.5-35 14-2 125 Observe the current carrying capacity of mounting rails. EC Prototype certificate from 3rd quarter 2002. for mounting on 3 green-yellow terminal width 16 ST 35-PE 30 36 19 4 10 (1) Plug-in bridge, for 2-pos. FBS 2-16 I max. : 101 A 30 05 96 3 10 (2) Screwdriver, for actuating the tension spring SZF 3-1,0 x 5,5 12 06 61 2 10 (3) Zack marker sheet, flat, (4) Zack strip, 10-section, for labeling in the white ZB 10:UNPRINTED 10 53 00 1 10 Width / length / end cover width [mm] 16 / 100 / Height (NS 35/7,5 / NS 35/15) [mm] 59 / 66.5 Maximum load current / cross section [A] / [mm 2 ] 125 / 35 Stranded with ferrule with plastic sleeve [mm 2 ] 2.5-35 Stranded with ferrule without plastic sleeve [mm 2 ] 2.5-35 Stranded with TWIN ferrule with plastic sleeve [mm 2 ] Stripping length [mm] 25 Internal cylindrical gauge (IEC 60 947-1) A 8 PHOENIX CONTACT 01.04.03 TNR: 5124897-03 http://www.phoenixcontact.com Phoenix Contact page 15 of 15