Cable Trays Technical Instructions & Specifications



Similar documents
TARIFF CODE and updates standard

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

Mechanical arms, belts and sheets

CABLE TRAY. Introduction

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

FRACASSO SCAFFOLDING PS 720

Installation Manuals Version n. 01 of 14/06/2013

SECTION PIPE HANGERS AND SUPPORTS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Dear costumers, You have just received our new catalogue with KOPOS KOLIN a.s. offer of metal cable support system products. Those types of products

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

INDUSTRIAL ROOFING CASE STUDY: The Advantages of Aluminized Stainless Steel. Roof Installed:

CABLE SUPPORT SYSTEMS

SECTION 4: Cable Ladder Stainless Steel & Aluminium

Switchboard system. NorLine 800

UNIVERSAL RAILING, STEEL

Session 14 Cable Support Systems

Cable management Steel wire cable trays

19 DYNAmax Free Standing Server C A B I N E T s

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Modular Access Floor for Data Center. From Rack to Row to Room to Building

19 DYNAmax Free Standing Server C A B I N E T s

WELAND TERMINOLOGY LOAD BEARING BAR CROSS BAR GRATING TYPE SAF MESH OPENING GRATING. LENGTH, SPAN WIDTH or LENGTH OF LOAD BAR GRATING

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Ruukki Finnera. The most intelligent roof ever seen.

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Product Information 19 / 45HU Data-Center-Rack (Cabinet)

Quality Regulations for Profiles

Master Panel 1000 W Wall

Cable Support Solutions

Timber Decks. Technical Note. March 2007

Anodes and Misc Equipment

Dock Hardware & Accessory Products Catalog

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

European Technical Assessment ETA-10/0153 of 10/06/2015

Master Panel 1000 R5 Roof

DSM 1 (800)

SERVER ROOM CABINET INSTALLATION CONCEPTS

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia Fax:

Metal Pressfitting Pipe Systems

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

Aluminium systems profile selection

WATERPROOFING OF WET ROOMS

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

Terminal Boxes Series 8146

STOCK LIST & BUYER S GUIDE

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Guide to enclosures for potentially explosive atmospheres

Electric Rotary Actuator - On/Off or programmable control actuator

Technical Data. Dimensions

Marine Type Cable Support Systems

Partitioning & Ceiling Product Information

STB Series Enclosures

Luxor. Automatic retractable bollard

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm)

Vitraflex Classic Modular Combination Shower and Changeroom Cubicles (c/w Telescopic Stainless Steel Leg Anchors)

GUARDRAIL POST STEEL

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

DIGITUS Network & Server Cabinets. UNIQUE Series

08. SEK IDC CONNECTORS

Aluminium Standard. Technical Data. Included in delivery

Quarry & Recycling Products

Mitel DECT Base Stations

There is no upside to. down time

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

DEFECTS IN SHEET ROOFING THAT IMITATES ROOF TILES AS A RESULT OF THEIR ANCHORAGE

Supply air diffuser ROKA/RPKA

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

PART 1 GENERAL 1.1 SECTION INCLUDES

North American Stainless

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

DEVIreg 330 (+5 to +45 C)

Uncovered Decks & Porches

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

How To Buy A Designo Grille

MERO Access Floor / Floor systems for data centers * *Ready for Cloud-Computing

Understanding Coating Weight Designations for Zinc-Based Coatings on Steel Sheet Rev 2.2 Jan-04

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

SECTION GUARDA SECURITY WINDOW SCREENS

OIL SPILL CONTAINMENT CONTAINERS AND RACKING

Embedded Parts Introduction - Anchors

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough

Naval construction systems english chinese

Table of Contents. IV. Interior Doors. 1. Product Training 2. Bilco Quote/Order Checklist

Cable Tray Selection-

Scepter PVC Molded Junction Boxes

12.1 Schlüter -KERDI-BOARD

CABLE TRENCH INSTALLATION GUIDE

Asphalt Shingle Application Requirements

Company presentation 03/09/2012

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

INSTRUCTIONS FOR USE

DYWIDAG-SYSTEMS INTERNATIONAL. DYWIDAG Barrier Cable System. Glendale Galleria Parking Structure, Glendale, California

Owner's Manual & Assembly Instructions

Transcription:

Cable Trays Technical Instructions & Specifications

Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased durability easy and quick installation reasonable cost minimum delivery time At the same time, the correct design and selection of the cable tray system is critical for the optimum performance of the system, both in technical and economical terms. For that reason, this catalogue is also a guide to the best selection and use of cable support products. This way, each project s specifications will be fully met with a system of minimum purchase, installation and maintenance costs. The first few pages provide some basic technical instructions for the correct selection of: corrosion resistance cable tray support type dimensions of supports and cable trays material thickness and distance between supports By following the instructions and the detailed product description of each product, engineers can easily select the correct item for each application. GUARANTEE METALLODOMI S.A. covers with limited guarantee of twe (2) years from the day of purchase for all the products manufactured Hot Dip Galvanized According to DIN EN ISO 1461. George Koundourakis General Manager Page 2

Corrosion Resistance Selection Our products are classified according to their corrosion resistance level as follows: 1. Products made of pre-galvanized sheet metal. Method: The sheet metal is dipped in zinc bath at 450 ο C according to the EN ISO 10142 standard. The resulting zinc layer has an average thickness of 20μm. The next step is punching and bending of the metal sheet. The surfaces resulting from cutting and punching are also protected against corrosion (up to 2mm of sheet thickness) due to the formation of zinc oxide. Use: Dry-air, indoor applications. 2. Products made of mild steel sheet and then hot-dip galvanized. Method: The mild steel sheet is punched and formed. The next step is hot-dip galvanizing according to the EN ISO 1461 standard. The resulting zinc thickness is about 60 μm. Use: Indoor applications with high moisture or outdoor applications. 3. Products made of stainless steel. Method: Stainless steel sheet is punched and formed. Use: Special applications, food or chemical industries and seaside installlations. Additional types of corrosion resistance can also be applied and offered: Products made of raw steel sheet, electro-galvanized Products made of mild steel sheet, hot-dip galvanized and epoxy powder coated. 4. Life span The life span of a zinc-coated material cannot be accurately predicted. However, it can be roughly estimated according to environmental conditions: Expected life metal (in years) Environment: Pre-galvanized Hot-dip galvanized Countryside: 6 13 15 50 Coastal: 2 8 5 20 Urban: 4 20 10 35 Industrial: 1 6 3 13 Page 3

Selection of Cable Support System Selection of dimensions: The basic criterion for selecting the suitable cable support system is the type and cross-section of the cables. For example, large cross-section cables which are energy carriers release significant quantities of heat, therefore they need to be routed using cable ladders in order to enable the air flow around the cables. Telephone, network, signal cables or even low power cables can be routed through cable trays. When the cross section and the number of cables to be routed are known, the suitable cable tray cross section can be estimated. The suggested selection process is the following: 1. The sum of cable cross sections is calculated. 2. The result is multiplied by a factor of 1.3 to take into account the random placement of the cables into the cable tray. 3. The new result is multiplied again with a minimum factor of 1.3 to consider some extra free space in the cable tray for possible additional cables to be routed through the cable tray in the future. 4. The cable tray cross section (width x height) that will be selected must be equal to or greater than the result of the above mentioned calculations. In order to facilitate calculations, the following table contains the dimensions of the most commonly used cables. It must be noted however that the values in the table are approximate. The respective tables of the cable manufacturer should be used for better results. Page 4

Diameters and Cross Sections of commonly used Cables Multi-thread Power Cables Single-thread Power Cables Type Diameter Cross section (mm) (cm 2 ) 1 x 4 6,5 0,33 1 x 6 7 0,38 1 x 10 8 0,50 1 x 16 9,5 0,71 1 x 25 12,5 1,23 3 x 1,5 8,5 0,57 3 x 2,5 9,5 0,71 3 x 4 11 0,95 4 x 1,5 9 0,64 4 x 2,5 10,5 0,87 4 x 4 12,5 1,23 4 x 6 13,5 1,43 4 x 10 16,5 2,14 4 x 16 19 2,84 4 x 25 23,5 4,34 4 x 35 26 5,31 5 x 1,5 9,5 0,71 5 x 2,5 11 0,95 5 x 4 13,5 1,43 5 x 6 14,5 1,65 5 x 10 18 2,54 5 x 16 21,5 3,63 5 x 25 26 5,31 7 x 1,5 10,5 0,87 7 x 2,5 13 1,33 Signal Cables Type Diameter Cross section (mm) (cm 2 ) 2 x 2 x 0,6 5 0,20 4 x 2 x 0,6 5,5 0,24 6 x 2 x 0,6 6,5 0,33 10 x 2 x 0,6 7,5 0,44 20 x 2 x 0,6 9 0,64 40 x 2 x 6,6 11 0,95 60 x 2 x 0,6 13 1,33 100 x 2 x 0,6 17 2,27 200 x 2 x 0,6 23 4,15 2 x 2 x 0,8 6 0,28 4 x 2 x 0,8 7 0,38 6 x 2 x 0,8 8,5 0,57 10 x 2 x 0,8 9,5 0,71 20 x 2 x 0,8 13 1,33 40 x 2 x 0,8 16,5 2,14 60 x 2 x 0,8 20 3,14 100 x 2 x 0,8 25,5 5,11 200 x 2 x 0,8 32 8,04 Type Diameter Cross section (mm) (cm 2 ) 1 x 10 10.5 0,87 1 x 16 11,5 1,04 1 x 25 12,5 1,23 1 x 35 13,5 1,43 1 x 50 15,5 1,89 1 x 70 16,5 2,14 1 x 95 18,5 2,69 1 x 120 20,5 3,30 1 x 150 22,5 3,98 1 x 185 25 4,91 1 x 240 28 6,16 1 x 300 30 7,07 3 x 1,5 11,5 1,04 3 x 2,5 12,5 1,23 3 x 10 17,5 2,41 3 x 16 19,5 2,99 3 x 50 26 5,31 3 x 70 30 7,07 3 x 120 36 10,18 4 x 1,5 12,5 1,23 4 x 2,5 13,5 1,43 4 x 6 16,5 2,14 4 x 10 18,5 2,69 4 x 16 21,5 3,63 4 x 25 25,5 5,11 4 x 35 28 6,16 4 x 50 30 7,07 4 x 70 34 9,08 4 x 95 39 11,95 4 x 120 42 13,85 4 x 150 47 17,35 4 x 185 52 21,24 4 x 240 58 26,42 5 x 1,5 13,5 1,43 5 x 2,5 14,5 1,65 5 x 6 18,5 2,69 5 x 10 20,5 3,30 5 x 16 22,5 3,98 5 x 25 27,5 5,94 5 x 35 34 9,08 5 x 50 40 12,57 Page 5

Cable Weight Tables TECHNICAL INSTRUCTIONS Multi-thread Power Cables Type Type Signal Cables Weight (kg/m) 1 x 4 0,08 1 x 6 0,105 1 x 10 0,155 1 x 16 0,23 1 x 25 0,33 3 x 1,5 0,135 3 x 2,5 0,19 3 x 4 0,265 4 x 1,5 0,16 4 x 2,5 0,23 4 x 4 0,33 4 x 6 0,46 4 x 10 0,69 4 x 25 1,64 4 x 35 2,09 5 x 1 0,19 5 x 2,5 0,27 5 x 4 0,41 5 x 6 0,54 5 x 10 0,85 5 x 16 1,35 5 x 25 1,99 7 x 1,5 0,235 7 x 2,5 0,35 Weight (kg/m) 2 x 2 x 0,6 0,03 4 x 2 x 0,6 0,035 6 x 2 x 0,6 0,05 10 x 2 x 0,6 0,065 20 x 2 x 0,6 0,11 40 x 2 x 0,6 0,2 60 x 2 x 0,6 0,275 100 x 2 x 0,6 0,445 200 x 2 x 0,6 0,87 2 x 2 x 0,8 0,04 4 x 2 x 0,8 0,055 6 x 2 x 0,8 0,08 10 x 2 x 0,8 0,115 20 x 2 x 0,8 0,205 40 x 2 x 0,8 0,38 60 x 2 x 0,8 0,54 100 x 2 x 0,8 0,875 200 x 2 x 0,8 1,79 Cable weight calculation: In order to proceed with the selection of cable support system, the total cable weight per meter length must be calculated first. For this calculation, cable weights can be found in tables provided by cable manufacturers. Such a table is provided below. Single-thread Power Cables Type Weight (kg/m) 1 x 10 0,18 1 x 16 0,24 1 x 25 0,35 1 x 35 0,46 1 x 50 0,6 1 x 70 0,8 1 x 95 1,1 1 x 120 1,35 1 x 150 1,65 1 x 300 3,2 3 x 1,5 0,19 3 x 2,5 0,24 3 x 10 0,58 3 x 16 0,81 3 x 50 1,8 3 x 70 2,4 3 x 120 4 4 x 1,5 0,22 4 x 2,5 0,29 4 x 6 0,4 4 x 16 1,05 4 x 25 1,6 4 x 35 1,75 4 x 50 2,3 4 x 70 3,1 4 x 95 4,2 4 x 120 5,2 4 x 150 6,4 4 x 185 8,05 4 x 240 11 5 x 1,5 0,27 5 x 2,5 0,35 5 x 6 0,61 5 x 10 0,88 5 x 16 1,25 5 x 25 1,95 5 x 50 3,5 Page 6

COMMENTS CABLE LADDERS Cable ladders are the most common solution for supporting and routing of cables in an installation. For this reason, cable ladders are available in a variety of sizes and standards, in order to cover the wide range of applications. Cable ladders and their accessories are classified in series Η35, Η60, Η85 and Η110 according to their profile height. It must be noted that all products displayed as perforated in this catalogue, are available in non-perforated form as well. Cable ladders are delivered in 3-meter long pieces. Other lengths between 2.5m and 6m are available on request. The corrosion resistance level available for each product is noted in the following tables with the respective letter: P: Pre-galvanized metal sheet H: Hot-dip galvanized metal sheet S: Stainless steel metal sheet In addition, all available products can be delivered epoxy powder coated to any desired color. TYPE H110 STOCK LENGTH: 3000mm PRODUCT DESCRIPTION PERFORATION: for ease in cable mounting and vetilation, holes 7x30mm in crossshape and hole centers 50mm in x-axis and 25mm in y-axis are punched. BENDED EDGE: on top of side rail for reinforcement and cable protection. Cable ladders can be manufactured from steel sheet pregalvanized acc. to EN ISO 10147 and also available in stock hot-dip galvanized acc. to EN ISO 1461. On request cable ladders made of stainless steel sheets can be manufactured. Page 7

SELECTION OF METAL SHEET THICKNESS & DISTANCE BETWEEN SUPPORTS According to the total cable weight per meter that has been calculated, the metal sheet thickness and the distance between supports can be selected. In this catalogue, a chart is provided for every cable tray type that gives the maximum allowed load per unit length for any combination of sheet metal thickness and distance between supports. By using the charts, the selected cable support system will be both robust and cost effective. Selection of support type The two basic criteria for selecting the support type are: The mounting surface (floor, wall, or ceiling) The load to be supported Our products cover all combinations of mounting surface and load to be supported. MATERIAL THICKNESS t=0,75mm Page 8

SELECTION OF METAL SHEET THICKNESS & DISTANCE BETWEEN SUPPORTS According to the total cable weight per meter that has been calculated, the metal sheet thickness and the distance between supports can be selected. In this catalogue, a chart is provided for every cable tray type that gives the maximum allowed load per unit length for any combination of sheet metal thickness and distance between supports. By using the charts, the selected cable support system will be both robust and cost effective. Selection of support type The two basic criteria for selecting the support type are: The mounting surface (floor, wall, or ceiling) The load to be supported Our products cover all combinations of mounting surface and load to be supported. MATERIAL THICKNESS t=1,00mm Page 9

SELECTION OF METAL SHEET THICKNESS & DISTANCE BETWEEN SUPPORTS According to the total cable weight per meter that has been calculated, the metal sheet thickness and the distance between supports can be selected. In this catalogue, a chart is provided for every cable tray type that gives the maximum allowed load per unit length for any combination of sheet metal thickness and distance between supports. By using the charts, the selected cable support system will be both robust and cost effective. Selection of support type The two basic criteria for selecting the support type are: The mounting surface (floor, wall, or ceiling) The load to be supported Our products cover all combinations of mounting surface and load to be supported. MATERIAL THICKNESS t=1,25mm Page 10

SELECTION OF METAL SHEET THICKNESS & DISTANCE BETWEEN SUPPORTS According to the total cable weight per meter that has been calculated, the metal sheet thickness and the distance between supports can be selected. In this catalogue, a chart is provided for every cable tray type that gives the maximum allowed load per unit length for any combination of sheet metal thickness and distance between supports. By using the charts, the selected cable support system will be both robust and cost effective. Selection of support type The two basic criteria for selecting the support type are: The mounting surface (floor, wall, or ceiling) The load to be supported Our products cover all combinations of mounting surface and load to be supported. MATERIAL THICKNESS t=1,50mm Page 11