RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC



Similar documents
RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RM4TG20 three-phase network control relay RM4-T - range V

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

PHOENIX CONTACT Features

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFE

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

48 SERIES Relay interface modules 10 A

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Digital input modules

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

38 Series - Relay interface modules A

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Analog signal converters CC-E I/I Current / current isolators

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Safety technique. Emergency stop module BO 5988 safemaster

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Thermistor motor protection

38 Series - Relay interface modules A

Preset Counter signo 721

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

49 Series - Relay interface modules A. Features

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

80 Series - Modular timers 16 A. Features

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Type: DILM9 10(24VDC) Article No.:

SURGE PROTECTIVE DEVICES

Redundancy Module QUINT-DIODE/40

SINEAX U553 Transducer for AC Voltage

CompactLogix Power Supplies Specifications

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

EMR measuring and monitoring relays

ABB i-bus KNX SA/S Switch Actuators Product Manual

R.C.C.B. s two-pole LEXIC

13 SERIES. Electronic step relays A

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

RY2 miniature industrial relays

Power Supplies 3. SDN-P DIN Rail Series

Quick Connect. quick - simple - efficient.

Voltage Regulator SPAU 341 C. Product Guide

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Type: DILM32 10(24V50HZ) Article No.:

Control Devices Catalogue. Control Devices. Preferred and Standard Products

MasterINTERFACE 39 Series - Relay interface modules

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Contact expansion modules

80 Series - Modular timers 16 A. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Relés e Contatores de Estado Sólido SIRIUS

E-STOP relays, safety gate monitors

Contact expander modules

Energy Management Energy Meter Type EM23 DIN

Technical catalogue. Modular DIN rail components Installation contactors

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

NX safety stand-alone

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

CQM1-SF200/CS1W-SF200

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

DS 600. A contact free flux gate based current measurement sensor 600A rms

E-STOP relays, safety gate monitors

MasterINTERFACE 39 Series - Relay interface modules

PNOZsigma - Base units

Feed-through terminal block - SSK 110 KER-EX

Safety automation solutions

7 - Phaseo power supplies and transformers

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

E-STOP relays, safety gate monitors

Bimetallic Overload Relay Specifications

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Actuator-Sensor-Interface

Transcription:

Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage Supply voltage limits Control circuit voltage limits Power consumption Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Zelio Control Modular measurement and control relays Multifunction control relay For 3-phase supply RM17TE Asymmetry Phase failure detection Phase sequence Undervoltage and overvoltage in window mode Time delay Adjustable 0.1...10 s, 10 % Switching capacity in VA Measurement range 1500 ms for time delay 250 V AC 250 V DC 10 ma at 5 V DC 5 A AC 5 A DC 208...480 V AC 3 phases 183...528 V AC - 12 %, + 10 % Un <= 1.8 VA AC Control circuit frequency 50...60 Hz +/- 10 % Output contacts Nominal output current 1 C/O 5 A Hysteresis 2 % Run up delay at power up Measuring cycle Threshold adjustment voltage Voltage range Adjustment of asymmetry threshold Measurement accuracy Repeat accuracy Measurement error Phase failure sensitivity Response time 0.5 s time delay 1250 VA 183...528 V AC <= 150 ms measurement cycle as true rms value +2...+17 % in the range 480 V AC -2...-12 % in the range 208 V AC -2...-17 % in the range 220 V AC 2...20 % of Un selected 208 V phase to phase 220 V phase to phase 380 V phase to phase 400 V phase to phase 415 V phase to phase 440 V phase to phase 480 V phase to phase 5...15 % of Un selected +/- 10 % of the full scale value 0.5 % for input and measurement circuit 3 % for time delay < 0.05 %/ C with temperature variation < 1 % over the whole range with voltage variation 0.7 Un < 200 ms in the event of a fault The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 7/9/2011 1

Marking CE : 73/23/EEC CE : EMC 89/336/EEC Overvoltage category III conforming to IEC 60664-1 Insulation resistance > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 [Ui] rated insulation voltage 400 V conforming to IEC 60664-1 Supply frequency 50/60 Hz +/- 10 % Operating position Electrical connection Any position without 1 conductor cable 0.2...2.5 mm² AWG24...AWG12 flexible with cable end 1 conductor cable 0.5...4 mm² AWG20...AWG11 solid without cable end 2 conductors cable 0.2...1.5 mm² AWG24...AWG16 flexible with cable end 2 conductors cable 0.5...2.5 mm² AWG20...AWG14 solid without cable end Tightening torque 0.6...1 N.m Housing material Status LED Self-extinguishing plastic 1 LED green for power ON 1 LED yellow for relay ON Mounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715 Electrical durability Mechanical durability Operating rate 100000 cycles 30000000 cycles <= 360 operations/hour under full load Utilisation category AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 Width Product weight 17.5 mm 0.13 kg Environment Immunity to microbreaks 10 ms Electromagnetic compatibility Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to EN/IEC 61000-6-2 Standards EN/IEC 60255-6 Product certifications CSA C-Tick GL GOST UL Ambient air temperature for storage -40...70 C Ambient air temperature for operation -20...50 C Relative humidity 95 % at 55 C conforming to IEC 60068-2-30 Vibration resistance 0.35 mm (f = 5...57.6 Hz conforming to IEC 60068-2-6/IEC 60255-21-1 1 gn (f = 57.6...150 Hz conforming to IEC 60068-2-6/IEC 60255-21-1 Shock resistance 15 gn for 11 ms conforming to IEC 60255-21-1 IP degree of protection IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 Dielectric test voltage 2 kv 1 min AC 50 Hz conforming to IEC 60255-5 2 kv 1 min AC 50 Hz conforming to IEC 60664-1 Non-dissipating shock wave 4 kv conforming to IEC 60255-5 4 kv conforming to IEC 60664-1 4 kv conforming to IEC 61000-4-5 RoHS EUR status Compliant RoHS EUR conformity date 0701 2

Dimensions Drawings Multifunction 3-Phase Supply Control Relays Dimensions and Mounting 3

Connections and Schema Multifunction 3-Phase Supply Control Relays Wiring Diagram 4

Technical Description Function Diagrams Phase Sequence Control, Phase Failure Detection (U measured < 0.7 x nominal supply voltage) and Asymmetry Detection Tt Time delay after crossing of threshold (adjustable on front panel) L1, Phases of the supply voltage monitored L2, L3 A Asymmetry threshold (adjustable from 5...15% of the nominal supply voltage) H Hysteresis 11-12, Output relay connections (refer to Connections and Schema) 11-14 Relay status: black color = energized. Control of Overvoltage and Undervoltage in Window Mode Tt Time delay after crossing of threshold (adjustable on front panel) H Hysteresis U> Overvoltage threshold U< Undervoltage threshold L1, Phases of the supply voltage monitored L2, L3 11-12, Output relay connections (refer to Connections and Schema) 11-14 Relay status: black color = energized. The overvoltage and undervoltage threshold in window mode is adjustable from 2 20% of Un: Un 208 V 220 V 380, 400, 415, 440 V 480 V Voltage threshold (%) < - 12-2 - 17-2 - 20-2 - 20-2 > + 2 + 20 + 2 + 20 + 2 + 20 + 2 + 10 5