N-1-1 Contingency Analysis using PowerWorld Simulator



Similar documents
Fault Analysis I PowerWorld Corporation

Introduction to PowerWorld Simulator: Interface and Common Tools

PowerWorld Simulator

Energy Management Systems (EMS)

NTTG Study Plan for the Public Policy Consideration Scenario

Transient Stability Analysis with PowerWorld Simulator

Power System Security in Market Clearing and Dispatch Mechanisms

Contouring and Advanced Visualization

OPTIMAL DISPATCH OF POWER GENERATION SOFTWARE PACKAGE USING MATLAB

Running a Load Flow Analysis

Distributed Flexible AC Transmission System (D FACTS) Jamie Weber ext. 13

Generation Interconnection Feasibility Study Report-Web Version. PJM Generation Interconnection Request Queue Position Z1-055

Generator Interconnection and Deliverability Study Methodology Technical Paper

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

RELIABILITY PLANNING CRITERIA

Preliminary Results of Analysis of the Broader Regional Markets Initiatives

Chapter 5. System security and ancillary services

LAB1 INTRODUCTION TO PSS/E EE 461 Power Systems Colorado State University

A progressive method to solve large-scale AC Optimal Power Flow with discrete variables and control of the feasibility

GENe Software Suite. GENe-at-a-glance. GE Energy Digital Energy

Steady-State Power System Security Analysis with PowerWorld Simulator

Dynamic Security Assessment in the Future Grid. Vijay Vittal Ira A. Fulton Chair Professor Arizona State University

Transmission Planning Standards for the Baltimore Gas & Electric Company Transmission System

Post Operational Readiness. Operational Services and Performance

CHAPTER 3 SECURITY CONSTRAINED OPTIMAL SHORT-TERM HYDROTHERMAL SCHEDULING

Load Dispatcher (Class Code 5223) Task List

Network Code on Operational Security

4.1.1 Generator Owner Transmission Owner that owns synchronous condenser(s)

Master/Local Control Center Procedure No. 13 (M/LCC 13) Communications Between the ISO and Local Control Centers

ATTACHMENT G. Network Operating Agreement

Security Policy Review: Credible Event Management. Scope and Methodology Draft for Industry 2014

Linear AC Power Flow for Disaster Management

Preliminary Feasibility Assessment For. The Rio Tinto Alcan to BCH Transfer Limit of 460 MW. With 50% Series Compensation on Both KMO KIT lines

MARKET EVENT REPORT. Scheduling Error Affecting Dispatch of Mintaro Gas Turbine Station. Electricity Market Operations Performance PREPARED BY:

Item 8: Houston Import RPG Project

Power System Simulation for Engineers (PSS/E): Fault Analysis

Record Specification and File Format for Specifying Contingency Definitions and Remedial Actions Schemes

Application Note. Example of user log on Magelis HMI with XB5S5B2L2 biometric switch. Advanced Technical Support - Brazil. Version: 1.

Alberta Reliability Standard Cyber Security Configuration Change Management and Vulnerability Assessments CIP-010-AB-1

Midwest Reliability Organization Procedure For NERC PRC-012

Automatic start of a generator

ECCO International, Inc. 268 Bush Street, Suite 3633 San Francisco, CA 94104

the points are called control points approximating curve

A New Method for Estimating Maximum Power Transfer and Voltage Stability Margins to Mitigate the Risk of Voltage Collapse

Modelling framework for power systems. Juha Kiviluoma Erkka Rinne Niina Helistö Miguel Azevedo

SPECIFICATION COG-2007

IESO Supply Deliverability Guidelines

Power System Operation Procedure: Short Term Projected Assessment of System Adequacy (ST PASA)

Table of Contents. Real-Time Reliability Must Run Unit Commitment and Dispatch (Formerly G-203) Operating Procedure

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

SOP-RTMKTS Test and Approve Operations Software Applications. Contents

Optimal Power Flow Analysis of Energy Storage for Congestion Relief, Emissions Reduction, and Cost Savings

How To Operate The Williston Uvls

Transmission Planning Study (Year 2022) for Cherokee 4 Replacement Alternatives. Final Report

17 Energ y Management Neil K. Stanton, Jay C. Gir i, and Anj an... Bose 17-1 Power System Data Acquisition and Control. .

Cost Benefit Methodology for Optimal Design of Offshore Transmission Systems

Risk of Large Cascading Blackouts

ABB Network Manager in Endesa s Energy Management Center

PSS E. High-Performance Transmission Planning Application for the Power Industry. Answers for energy.

Toward standards for dynamics in future electric energy systems The basis for plug and play industry paradigm

FRCC Standards Handbook. FRCC Automatic Underfrequency Load Shedding Program. Revision Date: July 2003

Study to Determine the Limit of Integrating Intermittent Renewable (wind and solar) Resources onto Pakistan's National Grid

FRCC Coordination Procedure. Title: FRCC Reliability Coordinator Contingency Analysis Monitoring Criteria

INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012

This document should be reviewed at least every two years.

Transmission Function Employees Job Titles and Descriptions 18 C.F.R 358.7(f)(1)

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Issue for the ERCOT Board of Directors

Robust Adaptive Topology Control

TDI's NYC Merchant CHPE Transmission Project with POI at Astoria (NYISO Queue #305) Deliverability Analysis

Pricing Transmission

CIP Cyber Security Configuration Change Management and Vulnerability Assessments

A Brief Review of Electric Power Energy Management Systems Bruce F. Wollenberg University of Minnesota

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Rules on Southern Companies Energy Auction Participation

PREMIUM CLEAN ROOM MONITOR MODELS 8630-CRM-S 8630-CRM-P

A Virtual Environment for Interactive Visualization of Power System Economic and Security Information

Generic Reliability Evaluation Method for Industrial Grids with Variable Frequency Drives

Typical Data Requirements Data Required for Power System Evaluation

CURTAILABLE RATE PROGRAM FOR INDIVIDUAL CUSTOMER LOADS

Optimizing Wind Generation in ERCOT Nodal Market Resmi Surendran ERCOT Chien-Ning Yu ABB/Ventyx Hailong Hui ERCOT

Increasing situational awareness of system operators by highly aggregated dynamic security results. Dr. Uros Kerin

Use Case Task 1-7: Network Equavalents between EMS & Planning

School of Electrical Engineering and Computer Science

Creating a One-line Diagram

EE and Reliability: SCE s LCR RFO and Preferred Resources Pilot. ACEEE Energy Efficiency as a Resource National Conference Mohammed Aliuddin

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

Priority Dispatch in Real Time Operation. Marie Hayden

Opportunity Cost Calculator v2: Energy Market Opportunity Costs Non-Regulatory Opportunity Costs

CALIFORNIA ENERGY COMMISSION. Real-Time Voltage Monitoring and VAR Management System CONSULTANT REPORT OCTOBER 2003 P F. Gray Davis, Governor

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function

Power Technology Issue 106

CIP Cyber Security Configuration Change Management and Vulnerability Assessments

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Power System Security Monitoring, Analysis, and Control. George Gross

Physical Address: City: State: Zip Code:

PC Software for VAV compact and modular controllers

When this standard has received ballot approval, the text boxes will be moved to the Guidelines and Technical Basis section of the Standard.

Transcription:

N-1-1 Contingency nalysis using PowerWorld Simulator uthor: PowerWorld Corporation Scott R. Dahman, P.E. Date: March 24, 2010 October 25, 2012 (revised)

Table of Contents Background and Objective... 2 Definitions... 2 N-1-1 Contingency nalysis Overview... 3 Contingency nalysis... 4 OPF and SCOPF... 5 System djustments after a Secondary Contingency... 6 System djustments after a Primary Contingency... 10 No Post-Contingency System djustments... 12 Objective Functions and Cost Curves... 13

N-1-1 Contingency nalysis Background and Objective NERC Standard TPL-001-1 (Transmission System Planning Performance Requirements) 1 proposes several requirements for demonstrating reliable operation of the power system over the planning horizon. Category P3 and P6 planning events described in TPL-001-1 involve an initial loss of a generator or transmission component, possibly followed by system adjustments, followed by another loss of a generator or transmission component. The approach for conducting analysis with PowerWorld Simulator will depend on if and when system adjustments may be applied to mitigate post-contingent violations, and the degree to which effective system adjustments are understood. Contingencies and system adjustments may be modeled with Simulator's Contingency nalysis tool. System adjustments are modeled explicitly as part of each contingency. Model Criteria may be assigned to actions which only occur under certain system conditions. nalysis using Simulator's optimal power flow (OPF) or security-constrained optimal power flow (SCOPF) may help the system planner identify appropriate actions for system adjustments to mitigate transmission line or interface overloads. (Voltage violations cannot be analyzed with the methods described here.) Contingency nalysis may be performed to evaluate the effectiveness of such system adjustments. Definitions Base Case: The power system in its normal steady-state, operation, with all elements in service that are expected to be in service. Primary Contingency: n loss of one or more system elements that occurs first. Primary Contingency may be a planned or unplanned event. Secondary Contingency: n contingency that occurs after the Primary Contingency. This is usually an unplanned event. System djustments: set of corrective actions executed by automatically by a control system or manually by a system operator to mitigate the effects of a contingency or strengthen the system to withstand a possible future contingency. System adjustments may include the opening or closing of a transmission element; the opening, closing, or redispatch of a generator; the changing of a phase shifting transformer angle; the opening, closing, or changing of the a switched shunt setpoint; or the curtailment of load. System adjustments are sometimes referred to as Remedial ction Schemes (RS) or Special Protection Schemes (SPS). System adjustments may include actions that occur every time a certain contingency occurs or actions that occur only when certain system conditions are met. N-1-1 Contingency: sequence of events consisting of the initial loss of a single generator or transmission component (Primary Contingency), followed by system adjustments, followed by another loss of a single generator or transmission component (Secondary Contingency). Model Criteria: n evaluation of system conditions in Simulator, that if met, would cause a conditional system adjustment to occur. 1 http://www.nerc.com/filez/standards/ssess-transmission-future-needs.html Page 2 of 14

N-1-1 Contingency nalysis N-1-1 Contingency nalysis Overview n overview of a suggested analysis process is shown in Figure 1. Base Case violations? Yes Fix violations No Run Primary Contingencies Traditional N-1 nalysis violations? Yes Model System djustments No pply ith Primary Contingency Run Secondary Contingencies For i = 1 to number of Primary Contingencies violations? No Yes Model System djustments Figure 1 - N-1-1 nalysis Process Several tools and techniques may be used in PowerWorld Simulator for performing each analysis step. Contingency analysis may be used to model the outages and the system adjustments. If all effective system adjustments are well-understood, contingency analysis may be the only tool needed. system that meets N-1-1 criteria would not reveal any violations during any of the Primary Contingencies, or during any of the Secondary Contingencies, with each of the Primary Contingencies as the reference case. Simulator's OPF and SCOPF tools tool may be used to identify possible system adjustments if they are not known. Page 3 of 14

Contingency nalysis N-1-1 Contingency nalysis Contingency analysis may be used to model the entire process depicted in Figure 1. To conduct N-1 analysis (orange sub-process), simply define all of the Primary Contingencies in Simulator's Contingency nalysis tool and run. System adjustments may be incorporated as contingency actions. For system adjustments that are conditional, use Simulator's Model Criteria to define the conditions under which the actions occur. n example is shown in Figure 2. Primary Contingencies Outage Conditional System djustment with Model Criteria Figure 2 - N-1 Contingency nalysis Figure 3 details the process for analyzing the Secondary Contingencies (the blue-shaded subprocess in Figure 1) with Simulator versions 14 and earlier. Page 4 of 14

N-1-1 Contingency nalysis Open Base Case and Primary and Secondary Contingencies For i = 1 to number of Primary Contingencies Select ith Primary Contingency Solve and Set as Reference Skip all contingencies except Secondary Contingencies to be considered with ith Primary Contingency Run Secondary Contingencies Save results to an aux or new pwb file. (Do not overwrite the Base Case.) Figure 3 - Secondary Contingency nalysis in PowerWorld Simulator Simulator also includes a feature (version 15 and later) for building an N-1-1 contingency list from a Primary Contingency list and a Secondary Contingency list. First, build or load the Primary Contingency list, including system adjustments if desired. Then, right click in the contingency grid and choose Insert Special Join ctive Contingencies... Then choose an auxiliary file containing the Secondary Contingencies. Simulator will add a new contingency for every combination of Primary and Secondary Contingency. The original Primary Contingencies will be retained, but they may then be deleted if desired. OPF and SCOPF The OPF and SCOPF tools may be used with the contingency analysis to help identify effective system adjustments to occur in either the base case, following a Primary Contingency or any of Page 5 of 14

N-1-1 Contingency nalysis the Secondary Contingencies. This is just one possible approach, as other tools such as sensitivity analysis and the line loading replicator may also provide valuable insight. NERC Standard TPL-001-1 indicates that "planned system adjustments... are allowed if such adjustments are executable within the time duration applicable to the Facility Ratings." System adjustments might then occur: 1. after the Secondary Contingency, in response to the N-1-1 system state; OR 2. after the Primary Contingency, to adjust the system such that no violations will occur following any possible Secondary Contingency; OR 3. not at all. The system must then be operated such that any possible combination of Primary and Secondary Contingency will not cause a violation. In addition, the OPF and SCOPF may be operated with various mixes of controls. Possible controls include redispatch of generation, curtailment of load, adjustment of phase-shifting transformer angles, adjustment of DC line setpoints, or changes in control area import schedules. The opening and closing of transmission lines cannot be considered as OPF or SCOPF controls, but could be analyzed with line outage or line closure distribution factors. Following adjustments to the Base Case, Primary Contingencies, and Secondary Contingencies, Contingency nalysis may be run as described previously to verify compliance of the system with the appropriate planning requirements. The following describes methods for applying Simulator's tools to the various situations described above. System djustments after a Secondary Contingency In this situation, the OPF is applied to mitigate violations in the post-contingent system state, without considering violations that could exist under further contingencies. Figure 4 illustrates a possible procedure for this analysis. Notes: 1. The system state following the Primary Contingency can be restored by simply restoring the reference state in Simulator. 2. The OPF will use the Contingency Rating Sets selected in the Limit Monitoring Settings for lines, transformers, and interfaces. To model sufficient system adjustments with the OPF controls, make sure that the selected Contingency Rating Sets are appropriate for the system state following the Secondary Contingency. Page 6 of 14

N-1-1 Contingency nalysis Open Base Case and Primary and Secondary Contingencies Select ith Primary Contingency Solve and Set as Reference For i = 1 to number of Primary Contingencies Save any changes to contingency definitions to aux file. Solve the jth Secondary Contingency For j = 1 to number of Secondary Contingencies violations? No Yes minimum control change Select an OPF objective function minimum cost Set generator costs and load benefits ll generator or load redispatches have uniform "cost" per MW Select mix of OPF controls Solve OPF Review control changes Incorporate desired control changes into Secondary Contingency definition Figure 4 - System djustments after a Secondary Contingency with OPF Page 7 of 14

N-1-1 Contingency nalysis The following figures illustrate an example on a 7-bus test case. The outage of the line between buses Four and Five occurred in the Primary Contingency. The outage of the line between buses Seven and Five occurred in the Secondary Contingency, resulting in an overload on the line between buses Two and Five. Figure 5 shows the application of the Secondary Contingency in the Contingency nalysis dialog and Figure 6 shows the resulting post-contingent system, without System djustments. Figure 5 - pplying Secondary Contingency in Simulator Page 8 of 14

N-1-1 Contingency nalysis 153 MW GC ON One 1.05 pu 89 MW 89 MW Two 64 MW 63 MW 80% 1.04 pu 51 MW 4 2 61 MW 57 MW 61 MW 1.00 pu 26 MW 26 MW 132 MW 13 15 GC ON 15 4 Three 121% 56 MW Five 0.97 pu 8 3 Four 1.00 pu 13 4 5 GC ON 20 Six 1.04 pu 51 MW 25 GC ON 1 MW 1 MW 1 MW 1 MW 201 MW GC ON slack Seven 1.04 pu 20 Figure 6 - One-line Diagram of Post-Contingent System Following the application of the OPF, the load at Bus 5 is curtailed and the generator outputs at Buses 1 and 7 are adjusted accordingly. The changes may be viewed in the OPF Dialog as shown in Figure 7. Control Changes Figure 7 - LP OPF Dialog Page 9 of 14

N-1-1 Contingency nalysis Simulator's Difference Flows tool may also be used to show changes in generators, loads, and flows. Figure 8 shows the change in load and generation with the one-line diagram. These system adjustments may then be incorporated into the Secondary Contingency definition and the contingency analysis re-run to verify compliance with N-1-1 criteria. -23 MW GC ON One 0.00 pu 2 2 Two 3 MW 3 MW 0.00 pu 2 MW 2 MW 1 MW 0.00 pu 1 MW 1 MW 24 MW 24 MW GC ON 1 MW Three 1 MW Five 0.01 pu Four 0.00 pu -24 MW GC ON Six 0.00 pu 2 MW GC ON 1 MW 1 MW 1 MW 1 MW -2 MW GC ON slack Seven 0.00 pu Figure 8 - Viewing OPF System djustments and Flow Changes with Difference Flows System djustments after a Primary Contingency In this situation, it is assumed that the system must be able to withstand a Secondary Contingency subsequent to the Primary Contingency, with no violations. Here, the SCOPF is applied to the post-primary Contingency system state, considering the entire set of Secondary Contingencies, to determine if any system adjustments are needed following the Primary Contingency, such that all Secondary Contingencies can occur without overloads. It is assumed that system adjustments will not occur following the Secondary Contingency. Figure 9 illustrates a possible procedure for this analysis. Page 10 of 14

N-1-1 Contingency nalysis Open Base Case and Primary and Secondary Contingencies For i = 1 to number of Primary Contingencies Select ith Primary Contingency Solve and Set as Reference Skip all contingencies except Secondary Contingencies to be considered with ith Primary Contingency Save any changes to contingency definitions to aux file. Run Contingency nalysis violations? No Yes minimum control change Select an OPF objective function minimum cost Set generator costs and load benefits ll generator or load redispatches have uniform "cost" per MW Select mix of OPF controls Solve SCOPF Incorporate desired control changes into Primary Contingency definition Review control changes Figure 9 - System djustments after a Primary Contingency with SCOPF Page 11 of 14

N-1-1 Contingency nalysis No Post-Contingency System djustments In this situation, it is assumed that the Base Case must be able to withstand any sequence of Primary and Secondary Contingencies with no violations. Here, the SCOPF is applied to the Base Case, with the goal of identifying system adjustments for the Base Case. Figure 10 illustrates a possible procedure for this analysis. Open Base Case Define all combinations of Primary and Secondary Contingencies as double element (N-2) contingencies Run Contingency nalysis Yes minimum control change violations? Select an OPF objective function No minimum cost Save new Base Case Set generator costs and load benefits ll generator or load redispatches have uniform "cost" per MW Select mix of OPF controls Solve SCOPF Review control changes Set the current case as the Contingency nalysis reference Incorporate desired control changes into Base Case. To incorporate all changes as dispatched by the SCOPF tool, simply save the case as the new Base Case Figure 10 - System djustments to Base Case with SCOPF Page 12 of 14

N-1-1 Contingency nalysis Objective Functions and Cost Curves Simulator OPF offers two options for the objective function, or the quantity that is being optimized subject to transmission constraints: minimum control change and minimum cost. When considering only generation redispatch for contingency system adjustments, minimum control change is usually the most straightforward and easiest to implement. Here, the OPF relieves the constraints with the minimum redispatch from the starting point. Increasing the output of a generator by one MW incurs the same "cost" as decreasing the output of a generator by one MW. In addition, all controllable generators have the same cost. If loads are incorporated as OPF controls, they also have the same uniform cost per MW to change their value from the present level. However, it may be preferable to associate a higher cost with load curtailment than with generator redispatch or to differentiate costs across different loads and generators. The minimum cost OPF objective function must be used in this case. Curtailable loads may then be assigned appropriate piecewise-linear benefit functions. Generators may be assigned normal piecewiselinear or cubic cost functions. To bias the OPF toward keeping generator controls at the current operating point, a generator may be assigned a piecewise linear cost function with a MW breakpoint at the current operating point. The cost function associated with output below the current output would have a slope equal to the negative of the slope above the current output. minimum of two breakpoints would be used: one at the generator's minimum output and one at the generator's current output. This is shown graphically in Figure 11. Cost ($/h) Slope of line is MWh Price 1 Slope of line is MWh Price 2: Set to -MWh Price 1 MW Break 1: Set to Gen Min MW MW Break 2: Set to Gen MW (present output) Gen Output (MW) Figure 11 - Example Generator Cost Function to Bias Minimum Cost OPF to Present Generator Output; Values in Bold are Input Variables for the Piecewise Linear Cost Curve If the base case changes and the load or current operating point of the generators is different from that which existed when the generator cost curves were created, then the cost curves would require updating to bias the controls to the current operating point. This task can be simplified Page 13 of 14

N-1-1 Contingency nalysis with the use of auxiliary files. For example, the following auxiliary script would give all generators a cost of $10/MWh to deviate from their present outputs: SCRIPT { Selectll(GEN); SetData(GEN, [GenBidMW, GenBidMWHR, GenBidMW:1, GenBidMWHR:1], ["@GenMWMin", -10, "@GenMW", 10], Selected); UnSelectll(GEN); } The case should be solved before establishing the breakpoints since redispatch may be needed to meet the current level of load and losses. When using loads as controls, it is also important to set appropriate minimum and maximum values for each controllable load. The maximum would normally be set to the nominal or starting value of the load, so that a load may be curtailed, but not increased as a system adjustment. Page 14 of 14