FRCC Coordination Procedure. Title: FRCC Reliability Coordinator Contingency Analysis Monitoring Criteria
|
|
|
- Ruby Benson
- 9 years ago
- Views:
Transcription
1 A. Purpose: The FRCC Reliability Coordinator (RC) Contingency Analysis (CA) application is essential to maintaining the reliability of the FRCC Bulk Electric System. The application has the capability to adequately monitor and analyze the FRCC Bulk Electric System (BES) elements and a portion of the adjacent RC s BES that could result in exceeding System Operating Limits (SOL) or Interconnection Reliability Operating Limits (IROL) within the FRCC RC Area. The purpose of this procedure is to ensure that the appropriate FRCC Bulk Electric System (BES) elements are accurately identified and monitored in order to assess potential FRCC BES SOL and IROL violation conditions by the FRCC RC agent. B. Applicability: FRCC Reliability Coordinator (RC) FRCC Balancing Authorities (BAs) FRCC Transmission Operators (TOPs) C. Procedure: The contingency and monitored element selection criteria along with the exceptions to those criteria are summarized in Appendix A and Appendix B of this procedure. This procedure along with the appendices has been developed and reviewed by the FRCC Operating Reliability Subcommittee (ORS) and is intended to establish the minimum monitoring bounds for the FRCC RC CA application. Due to the sensitive nature of specific element information, the complete exceptions lists of this procedure are maintained, on a FRCC Reliability Only Group (ROG) version of Appendix A and Appendix B, with access limited to FRCC ROG personnel. 1.0 Developing the RC CA application contingency list: The FRCC Reliability Coordinator (RC) shall maintain the model used for contingency analysis and include, at a minimum, the following elements as contingencies in the CA application: BES generators of 100 MW and above, and BES facilities 100kV and above except transmission lines that are radially fed and transformers with the low side voltage below 115kV. Credible bus outages identified by the TOPs that are approved by ORS and based on the C2 (Breaker Failure) screening analysis in the FRCC summer and winter transmission assessments as listed in Appendix C. Specifically identified SOLs and IROLs in Appendix A of the FRCC-PROC-RC-FAC-011, System Operating Limits Methodology for the Operations Horizons document will be Revision Date: 4/12/11 Operating Reliability Subcommittee (ORS) Page 1 of 8
2 monitored in accordance with system conditions. This list may include SOLs and IROLs that cannot be shown as a databank rating or single line rating or specifically identified multiple contingencies (e.g. corridor flow limit, interface limit or voltage limits). This may require temporary or continuous CA application monitoring by the RC Agent depending on system conditions. Monitoring shall be in accordance with FRCC-PROC-RC-FAC-011. Any other specific facilities deemed important to the reliability of the FRCC Bulk Electric System not identified in Appendix A of FRCC-PROC-RC-FAC-011, will be identified on the FRCC RC Contingency Exceptions List, which is maintained on the ROG version of Appendix A of this procedure. 2.0 Developing the RC CA application monitoring list: As transmission system element outages are considered in the CA application, the displayed impact of those outages on facilities will be monitored by the FRCC RC Agent and responses coordinated as appropriate. If a potential violation of a monitored limit occurs in excess of the FRCC minimum acceptable reliability conditions (as defined in the Reliability Process for the FRCC Bulk-Power Electric System), the affected entity will be notified. At a minimum, the FRCC RC Agent will monitor for potential violations on the following elements or facilities, when analyzing impacts of contingencies included in the RC CA application. BES facilities 100kV and above except transmission lines that are radially fed and transformers with the low side voltage below 115kV. Any other facilities deemed important to reliability of the FRCC Bulk Electric System will be identified on the FRCC RC Violation Exceptions List, maintained on the Reliability Only Group (ROG) version of Appendix B of this procedure. Responsibilities RC Agent Responsibilities As warranted by significant system topology changes, the FRCC RC Agent will document a benchmark review of the CA application contingencies to the FRCC RC Contingency Analysis Contingency as described in the ROG version of Appendix A of this procedure. As warranted by significant system topology changes, the FRCC RC Agent will document a benchmark review of the CA application monitored violations to the FRCC RC Contingency Analysis Violation Monitoring as described in the ROG version of Appendix B of this procedure. As warranted by significant system topology changes, the FRCC RC Agent will document a benchmark review of the CA application buss contingencies to the Revision Date: 4/12/11 Operating Reliability Subcommittee (ORS) Page 2 of 8
3 FRCC RC Contingency Analysis Violation Monitoring as described in the ROG version of Appendix C of this procedure. Results of the review and any corrective actions will be reported to the FRCC ORS. Operating Reliability Subcommittee (ORS) Responsibilities As warranted by significant system topology changes,, the FRCC ORS will document a review of this procedure, including the minimum criteria and exceptions lists as set forth in the ROG versions of Appendix A and Appendix B of this procedure. This is to ensure that all elements and facilities important to the reliability of the FRCC Bulk Electric System are included in the Reliability analysis supported by the RC CA application. FRCC ORS will evaluate any requests to modify the criteria or exceptions list as set forth in the ROG versions of Appendix A, Appendix B and Appendix C of this procedure. FRCC Operating Entity Responsibilities D. Appendices: As warranted by significant system topology changes, the FRCC Balancing Authorities (BAs) and Transmission Operators (TOPs) will document a benchmark review of their system to the minimum criteria and exceptions lists as set forth in the ROG versions of Appendix A, Appendix B and Appendix C of this procedure, to ensure appropriate contingencies and violations are being monitored by the FRCC RC agents. TOPs shall provide data for IPP generation (100MW or greater) connected to their system BAs shall provide data for IPP generation (100 MW or greater) for which they have firm contracts. Provide notification to the FRCC ORS and the FRCC RC agent if new facilities are placed in service that meet the monitoring criteria set forth in this procedure. Provide written request to the FRCC ORS to include any new facilities on the FRCC RC Contingency Exceptions List, the FRCC RC Violation Exceptions List or the FRCC RC Contingency for Busses List, as set forth in the ROG versions of Appendix A, Appendix B and Appendix C of this procedure. Provide written request to the FRCC ORS to remove any facilities from the FRCC RC Contingency Exceptions List, the FRCC RC Violation Exceptions List or the FRCC RC Contingency for Busses List, as set forth in the ROG versions of Appendix A, Appendix B and Appendix C of this procedure. Revision Date: 4/12/11 Operating Reliability Subcommittee (ORS) Page 3 of 8
4 Appendix A: FRCC RC Contingency Analysis Contingency Appendix B: FRCC RC Contingency Analysis Violation Monitoring Appendix C: FRCC RC Contingency Analysis Contingency for Busses Revision Date: 4/12/11 Operating Reliability Subcommittee (ORS) Page 4 of 8
5 E. Revision History: Revision Date Action Change Tracking Conversion of prior RRO legacy document Specific reference to FRCC SOL and IROL list monitoring criteria added Changed the contingency list to specifically address BES Added language to add credible bus outages to a new Appendix C Added specific multiples to Appendix B. New Revision Date: 4/12/11 Operating Reliability Subcommittee (ORS) Page 5 of 8
6 Appendix A FRCC RC Contingency Analysis Contingency General contingency list criteria: The FRCC Reliability Coordinator (RC) shall maintain the model used for contingency analysis and include, at a minimum, the following elements as contingencies in the CA application: BES generators of 100 MW and above, and BES facilities 100kV and above except transmission lines that are radially fed and transformers with the low side voltage below 115kV. Credible bus outages identified by the TOPs that are approved by ORS and based on the C2 (Breaker Failure) screening analysis in the FRCC Summer and Winter Transmission assessments and listed in Appendix C. Specifically identified SOLs and IROLs in Appendix A of the FRCC-PROC-RC-FAC-011, System Operating Limits Methodology for the Operations Horizons document will be monitored in accordance with system conditions. This list may include SOLs and IROLs that cannot be shown as a databank rating or single line rating or specifically identified multiple contingencies (e.g. corridor flow limit, interface limit or voltage limits). This may require temporary or continuous CA application monitoring by the RC Agent depending on system conditions. Monitoring shall be in accordance with FRCC-PROC-RC-FAC-011. Any other specific facilities deemed important to the reliability of the FRCC Bulk Electric System not identified in Appendix A of FRCC-PROC-RC-FAC-011, will be identified on the FRCC RC Contingency Exceptions List, below FRCC RC Contingency Exceptions List: This list has been created to ensure that appropriate (as determined by ORS) lower voltage element contingencies, corridor threat contingencies and multiple contingencies are documented and available for use by the FRCC RC. The contingencies should be applied to the FRCC Bulk Electric System model by the FRCC RC CA application on an on-going basis or when a specific corridor threat is identified. The current list includes: The information on this list is considered ROG (Reliability Only Group), and is for reliability use only. The actual list is maintained separately with access limited to ROG personnel only. All information is considered ROG (Reliability Only Group), and is for reliability use only *** Do not distribute to non-rog members *** Revision Date: 4/12/11 Operating Reliability Subcommittee (ORS) Page 6 of 8
7 Appendix B FRCC RC Contingency Analysis Violation Monitoring General monitored element list criteria: As transmission system element outages are considered in the CA application, the displayed impact of those outages on facilities will be monitored by the FRCC RC Agent and responses coordinated as appropriate. If violation of a monitored limit occurs in excess of the FRCC minimum acceptable reliability conditions (as defined in the Reliability Process for the FRCC Bulk-Power Electric System), the affected entity will be notified. At a minimum, the FRCC RC will monitor for violations on the following elements or facilities when analyzing impacts of contingencies included in the RC CA application. BES facilities 100kV and above except transmission lines that are radially fed and transformers with the low side voltage below 115kV. Any other facilities deemed important to reliability of the FRCC Bulk Electric System or to individual operating entities, will be identified on the FRCC RC Violation Exceptions List, below. FRCC RC Violation Exceptions List: This list has been created to ensure that appropriate monitoring of post-contingency impacts, are included in the FRCC RC Contingency Analysis application monitored element function. The current list includes: The information on this list is considered ROG (Reliability Only Group), and is for reliability use only. The actual list is maintained separately with access limited to ROG personnel only. Revision Date: 4/12/11 Operating Reliability Subcommittee (ORS) Page 7 of 8
8 Appendix C FRCC RC Contingency Analysis Contingency for Busses The FRCC RC Agent has the capability to add busses to its real-time Contingency List. The busses below have been screened through the semi-annual FRCC Summer and Winter Assessments as part of the C2 ( breaker failure) screening analysis. Based on the results of the C2 assessment, a TOP can request that the FRCC RC add a particular credible bus outage to the real-time Contingency List in the Contingency Analysis application. Below is a list of the credible bus outages on the real-time Contingency List: Revision Date: 4/12/11 Operating Reliability Subcommittee (ORS) Page 8 of 8
DISCUSSION PAPER: Peak Reliability Performance Metrics
DISCUSSION PAPER: Peak Reliability Performance Metrics Executive Summary Performance metrics are critical for any organization in order to encourage improvement, effectiveness and efficiency; to assess
FRCC Standards Handbook. FRCC Automatic Underfrequency Load Shedding Program. Revision Date: July 2003
F R C C FRCC Standards Handbook FRCC Automatic Underfrequency Load Shedding Program Revision Date: July 2003 FRCC Underfrequency Load Shedding Program Modification and Approval Process Requests to modify
Energy Management System (EMS) Model Updates and Quality Assurance (QA)
PJM Manual 3A: Energy Management System (EMS) Model Updates and Quality Assurance (QA) Revision: 10 Effective Date: June 25, 2015 Prepared by: Operation Support Division PJM 2015 PJM 2007 Revision 0, Effective
When this standard has received ballot approval, the text boxes will be moved to the Guidelines and Technical Basis section of the Standard.
CIP-002-5 Cyber Security BES Cyber System Categorization When this standard has received ballot approval, the text boxes will be moved to the Guidelines and Technical Basis section of the Standard. A.
IESO Supply Deliverability Guidelines
PUBLIC IMO_GDL_0021 IESO Supply Deliverability Guidelines Issue 3.0 This document is to be used to evaluate long-term system adequacy and connection assessments Public Disclaimer The posting of documents
3. Purpose: To improve the reliability of the Bulk Electric System by requiring the reporting of events by Responsible Entities.
A. Introduction 1. Title: Event Reporting 2. Number: EOP-004-2 3. Purpose: To improve the reliability of the Bulk Electric System by requiring the reporting of events by Responsible Entities. 4. Applicability:
CIP-014-1 Physical Security. Nate Roberts CIP Security Auditor I
CIP-014-1 Physical Security Nate Roberts CIP Security Auditor I Notes Critical Infrastructure Protection (CIP) Standard CIP-014-1 is currently pending approval by the Federal Energy Regulatory Commission
Summary of CIP Version 5 Standards
Summary of CIP Version 5 Standards In Version 5 of the Critical Infrastructure Protection ( CIP ) Reliability Standards ( CIP Version 5 Standards ), the existing versions of CIP-002 through CIP-009 have
Duke Energy Progress Standards of Conduct Transmission Function Employee Job Titles and Job Descriptions 9/1/13
Duke Energy Progress Standards of Conduct Transmission Function Employee Job Titles and Job Descriptions 9/1/13 Transmission Operations & Planning Carolinas Power System Operations Director Power System
NERC Cyber Security Standards
SANS January, 2008 Stan Johnson Manager of Situation Awareness and Infrastructure Security [email protected] 609-452-8060 Agenda History and Status of Applicable Entities Definitions High Level of
MARKET EVENT REPORT. Scheduling Error Affecting Dispatch of Mintaro Gas Turbine Station. Electricity Market Operations Performance PREPARED BY:
Scheduling Error Affecting Dispatch of Mintaro Gas Turbine Station PREPARED BY: Electricity Market Operations Performance DATE: 26 August 2010 Contents 1 Introduction... 3 2 Background... 3 3 Scheduling
Load Dispatcher (Class Code 5223) Task List
A. Load Dispatching, General Load Dispatcher (Class Code 5223) Task List 1. Prior to work shift speaks to Load Dispatcher(s), reviews hardcopy and computer logs, and looks at the dispatcher's diagram board
Master/Local Control Center Procedure No. 13 (M/LCC 13) Communications Between the ISO and Local Control Centers
Master/LCC Procedure No. 13 - Communications Master/Local Control Center Procedure No. 13 (M/LCC 13) Communications 1. References... 2 2. Background... 3 3. Responsibilities... 3 4. Procedure... 4 4.1
Use Case Task 1-7: Network Equavalents between EMS & Planning
Use Case Task 1-2: Transport Contingency Specifications Page 1 Use Case Task 1-7: Equavalents between EMS & 1 Summary: Export Equavalents from the EMS or another application for use by the application(s).
Generation Interconnection Feasibility Study Report-Web Version. PJM Generation Interconnection Request Queue Position Z1-055
Generation Interconnection Feasibility Study Report-Web Version For PJM Generation Interconnection Request Queue Position Z1-055 South Bend Generation Project March 2014 PJM Interconnection 2014. All rights
16 West Coast Regional Plan
16 West Coast Regional Plan 16.1 Regional overview 16.2 West Coast transmission system 16.3 West Coast demand 16.4 West Coast generation 16.5 West Coast significant maintenance work 16.6 Future West Coast
Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering
Title 20 PUBLIC SERVICE COMMISSION Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES Chapter 02 Engineering Authority: Public Utility Companies Article, 2-121, 5-101 and 5-303, Annotated Code of Maryland.
TERMS AND CONDITIONS
Virginia Electric and Power Company TERMS AND CONDITIONS XXIV. GENERATOR INTERCONNECTION STANDARD Electric generator interconnection service includes only the ability to interconnect an electric generator
Transmission Planning Standards for the Baltimore Gas & Electric Company Transmission System
Transmission Planning Standards for the Baltimore Gas & Electric Company Transmission System Prepared By: Transmission Planning Unit Baltimore Gas & Electric Company Table of Contents 1. INTRODUCTION
SOP-RTMKTS.0060.0005 - Test and Approve Operations Software Applications. Contents
SOP-RTMKTS.0060.0005 - Test and Approve Operations Software Applications Contents 1. Objective... 2 2. Background... 2 3. Responsibilities... 3 4. Controls... 4 5. Instructions... 5 5.1 Document Operations
Report to the Minister Responsible for the Qulliq Energy Corporation. Respecting:
Report to the Minister Responsible for the Qulliq Energy Corporation Respecting: An Application by the Qulliq Energy Corporation For Approval of Major Project Permit to Upgrade the Iqaluit Distribution
Updated SYSTEM IMPACT STUDY OF NEW ENGLAND AREA
CROSS SOUND CABLE PROJECT 330MW HVdc INTERCONNECTION BETWEEN NEW HAVEN, CONNECTICUT AND SHOREHAM, NY Updated SYSTEM IMPACT STUDY OF NEW ENGLAND AREA Subordinate Status Removal and Amendment of Approved
Item 8: Houston Import RPG Project
: Houston Import RPG Project Jeff Billo Manager, Transmission Planning Board of Directors Meeting April 8, 2014 Study Overview ERCOT has determined that there will be a need for additional import capacity
Power System Security Monitoring, Analysis, and Control. George Gross
ECE 573 Power System Operations and Control Power System Security Monitoring, Analysis, and Control George Gross Department of Electrical and Computer Engineering University of Illinois at Urbana-Champaign
Power System Operation Procedure: Short Term Projected Assessment of System Adequacy (ST PASA)
ELECTRICITY INDUSTRY ACT ELECTRICITY INDUSTRY (WHOLESALE ELECTRICITY MARKET) REGULATIONS 2004 WHOLESALE ELECTRICITY MARKET RULES Power System Operation Procedure: Short Term Projected Assessment of System
Job Descriptions. Job Title Reports To Job Description TRANSMISSION SERVICES Manager, Transmission Services. VP Compliance & Standards
Updated July 11, 2013 Job Descriptions Job Title Reports To Job Description TRANSMISSION SERVICES VP Compliance & Standards Develops strategy and business plans for efficient, safe, reliable, regulatorycompliant
Responsibility for Outage Coordination is designated by 4 key artifacts: 1. FERC Order 2000 FERC Order 2000 (Docket No. RM99-2-000; Order No.
1 2 3 4 Responsibility for Outage Coordination is designated by 4 key artifacts: 1. FERC Order 2000 FERC Order 2000 (Docket No. RM99-2-000; Order No. 2000) comments regarding Transmission and Generation
Treasure Valley Electric Plan - Community Advisory Committee
Treasure Valley Electric Plan - Community Advisory Committee What is a transmission line and why are they necessary? A transmission line is used to conduct electricity between two points. Without high
Alberta Reliability Standard Cyber Security System Security Management CIP-007-AB-5
A. Introduction 1. Title: 2. Number: 3. Purpose: To manage system security by specifying select technical, operational, and procedural requirements in support of protecting BES cyber systems against compromise
ATTACHMENT G. Network Operating Agreement
ATTACHMENT G Network Operating Agreement 1. PURPOSE OF NETWORK OPERATING AGREEMENT The purpose of this Agreement is to identify contractual requirements related to Network Integration Transmission Service
References... 4. Appendices... 5. I. INTRODUCTION... 6 A. Background... 6 B. Standards... 6
ISO New England Operating Procedure No. 14 - Technical Requirements for Generators, Demand Resources, Asset Related Demands and Alternative Technology Regulation Resources Effective Date: January 29, 2015
How To Operate The Williston Uvls
WND Winter Operating Guide 2012/2013 1 WND Operating Study Using EQ-890-2012WIN- FINAL.sav developed through the 890 process Got load updates from MDU, Central Power, UM G&T Made several topology updates
GLOSSARY. Glossary of Terms for Capacity Based Demand Response PUBLIC. Issue 3.0 GOT-1
PUBLIC GOT-1 GLOSSARY Glossary of Terms for Capacity Based Demand Response Issue 3.0 This document provides a glossary of terms with definitions used in the Capacity Based Demand Response program. Public
System Operator Certification Program Administrative Guidelines
System Operator Certification Program Send your comments to [email protected] by September 24, 2004 Maintaining NERC System Operator Credential Through the Use of Continuing Education Credit Hours North
Generation and Transmission Interconnection Process
PJM Manual 14A Generation and Transmission Interconnection Process Revision: 18 Effective Date: January 28, 2016 Prepared by Planning Division Generation Interconnection Department PJM 2016 Table of Contents
Transmission Planning Study (Year 2022) for Cherokee 4 Replacement Alternatives. Final Report
Transmission Planning Study (Year 2022) for Cherokee 4 Replacement Alternatives (Required per CPUC Decision No. C10-1328) Final Report (Submitted with Public Service s 2011 ERP) Executive Summary The objective
Kent Active System Management (KASM) Oct 2015 / Matthieu Michel
Kent Active System Management (KASM) Oct 2015 / Matthieu Michel Project Background (update): D Heat Map: SPN D Connection Offers Accepted (Cumulative) 1W D Heat map (June 2015) SPN D Connection Offers
149 FERC 61,140 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION. 18 CFR Part 40. [Docket No. RM14-15-000; Order No.
149 FERC 61,140 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION 18 CFR Part 40 [Docket No. RM14-15-000; Order No. 802] Physical Security Reliability Standard (Issued November 20, 2014) AGENCY:
A. Introduction. B. Requirements. Standard PER-005-1 System Personnel Training
A. Introduction 1. Title: System Personnel Training 2. Number: PER-005-1 3. Purpose: To ensure that System Operators performing real-time, reliability-related tasks on the North American Bulk Electric
Physical Security Reliability Standard Implementation
Physical Security Reliability Standard Implementation Tobias Whitney, Manager of CIP Compliance (NERC) Carl Herron, Physical Security Leader (NERC) NERC Sub-Committee Meeting New Orleans, Louisiana CIP-014
OE-417 ELECTRIC EMERGENCY INCIDENT AND DISTURBANCE REPORT...
U.S. DEPARTMENT OF ENERGY OFFICE OF ELECTRICITY DELIVERY AND ENERGY RELIABILITY Washington, D.C. 20585 OMB No. 1901-0288 Expiration Date: 03/31/2018 Burden Per Response: 2.16 hours Revised: November 2014
Preliminary Feasibility Assessment For. The Rio Tinto Alcan to BCH Transfer Limit of 460 MW. With 50% Series Compensation on Both KMO KIT lines
Preliminary Feasibility Assessment For The Rio Tinto Alcan to BCH Transfer Limit of 460 MW With 50% Series Compensation on Both KMO KIT lines Report : ASP2010-T001 July 2010 Asset Strategy & Planning,
Post Operational Readiness. Operational Services and Performance
Post Operational Readiness Confirmation i Post Operations Certificate 19 th November 2012 Dave Carroll Operational Services and Performance EirGrid Overview Process Pre-Requisites 1. Performance Monitoring
EL PASO ELECTRIC COMPANY (EPE) GENERATOR INTERCONNECTION FEASIBILITY STUDY FOR PROPOSED XXXXXXXX GENERATION ON THE SIERRA BLANCA-FARMER 69 KV LINE
EL PASO ELECTRIC COMPANY (EPE) GENERATOR INTERCONNECTION FEASIBILITY STUDY FOR PROPOSED XXXXXXXX GENERATION ON THE SIERRA BLANCA-FARMER 69 KV LINE El Paso Electric Company System Planning Department April
Robust Adaptive Topology Control
Robust Adaptive Topology Control Mladen Kezunovic, PI Texas A&M University Kory W. Hedman, Co-PI Arizona State University January 14-15, 2015 System Integration Robust Adaptive Topology Control (RATC)
Joint Con Edison LIPA Offshore Wind Power Integration Project Feasibility Assessment
Joint Con Edison LIPA Offshore Wind Power Integration Project Feasibility Assessment March 20, 2009 Joint Con Edison LIPA Offshore Wind Power Integration Project Feasibility Assessment Table of Contents:
TDI's NYC Merchant CHPE Transmission Project with POI at Astoria (NYISO Queue #305) Deliverability Analysis
R103-11 TDI's NYC Merchant CHPE Transmission Project with POI at Astoria (NYISO Queue #305) Deliverability Analysis Prepared for Transmission Developers, Inc. Submitted by: Larry Eng, Staff Consultant
Alberta Reliability Standard Cyber Security Security Management Controls CIP-003-AB-5
A. Introduction 1. Title: 2. Number: 3. Purpose: To specify consistent and sustainable security management controls that establish responsibility and accountability to protect BES cyber systems against
This document should be reviewed at least every two years.
1.0 Change Control Version Date Modification Author(s) Reviews and Approvals by Issue 1 06 August 2007 Initial Document Philip J. Tatro David Wright Issue 2 29 February Removed Confidential from Philip
Network Consulting for Power Grid Optimization
Network Consulting for Power Grid Optimization Project experience in India Network Consulting Competences Page 1 Our worldwide representation Manchester The Hague Denver Schenectady San Diego Houston Mexico
Transmission Function Employees Job Titles and Descriptions 18 C.F.R 358.7(f)(1)
Date of Last Change to the Provided Information August 27 th, 2015 Director, Transmission Operations The employee in this position is responsible for effectively managing the operation of FirstEnergy Utilities
SPECIFICATION COG-2007
Cleco Power LLC SPECIFICATION COG-2007 FOR PARALLEL OPPERATION OF CUSTOMER-OWNED GENERATION ON CLECO S ELECTRICAL SYSTEM Revised: March 7, 2014 CONTENTS ITEM NO. TITLE PAGE NO. 1.0 Scope 3 2.0 Policy On
TRANSMISSION & DISTRIBUTION PLANNING CRITERIA & GUIDELINES
TRANSMISSION & DISTRIBUTION PLANNING CRITERIA & GUIDELINES Issued: September 20, 2010 Revision 3 TABLE OF CONTENTS 09/20/10 I. INTRODUCTION... 1 II. DOCUMENT REVIEW AND UPDATE PROCESS... 1 A. MAJOR REVISION
2012 Workers Compensation Data Call Summary Insurance Oversight Part A
2012 Workers Compensation Data Call Summary Insurance Oversight Part A INTRODUCTION: Revisions to the Illinois Workers Compensation Act (820 ILCS 305/29) in the fall of 2011 required the Department of
Alberta Reliability Standard Cyber Security Personnel & Training CIP-004-AB-5.1
Alberta Reliability Stard A. Introduction 1. Title: 2. Number: 3. Purpose: To minimize the risk against compromise that could lead to misoperation or instability in the bulk electric system from individuals
N-1-1 Contingency Analysis using PowerWorld Simulator
N-1-1 Contingency nalysis using PowerWorld Simulator uthor: PowerWorld Corporation Scott R. Dahman, P.E. Date: March 24, 2010 October 25, 2012 (revised) Table of Contents Background and Objective... 2
Rule 5.500 Fast Track Analysis for National Life Insurance Co.
Rule 5.500 Fast Track Analysis for National Life Insurance Co. For a 500 kw Solar array to be located at 155 Northfield Street in Montpelier, Vermont Green Mountain Power Pam Allen Date: 5/31/13 SECTION
Dynamic Security Assessment in the Future Grid. Vijay Vittal Ira A. Fulton Chair Professor Arizona State University
1 Dynamic Security Assessment in the Future Grid Vijay Vittal Ira A. Fulton Chair Professor Arizona State University 2 Key requirements for DSA Need to perform DSA as close to real time as possible Need
Southern California Edison Revised Cal. PUC Sheet No. 59134-E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.
Southern California Edison Revised Cal. PUC Sheet No. 59134-E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No. 58300-E Schedule TOU-8-RBU Sheet 1 APPLICABILITY Applicable to the additional
Alberta Reliability Standard Cyber Security Configuration Change Management and Vulnerability Assessments CIP-010-AB-1
A. Introduction 1. Title: 2. Number: 3. Purpose: To prevent and detect unauthorized changes to BES cyber systems by specifying configuration change management and vulnerability assessment requirements
BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION'^^ j E DIRECT TESTIMONY RAJESH GUPTA PROJECT MANAGER, ENTERGY SERVICES, INC.
BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION'^^ j E s : D IN THE MATTER OF THE APPLICATION OF ENTERGY ARKANSAS, INC. FOR A CERTIFICATE OF ENVIRONMENTAL COMPATIBILITY AND PUBLIC NEED TO CONSTRUCT AND OPERATE
Future of Electric Distribution Dialogue
Future of Electric Distribution Dialogue Webinar Series Session I: State of U.S. Electric Distribution July 11, 2012 2:00 3:30 p.m. EDT Session I: State of U.S. Electric Distribution 2:00 p.m. Opening
Outage Scheduling Manual
MANUAL 29 Outage Scheduling Manual July 2015 Version: 4.3.1 Effective Date: 07/29/2015 Committee Acceptance: 6/11/2015 OC This document was prepared by: NYISO Energy Market Operations New York Independent
Midwest Reliability Organization Procedure For NERC PRC-012
Midwest Reliability Organization Procedure For NERC PRC-012 A. Introduction The following procedure developed by the MRO Protective Relay Subcommittee (PRS) and Transmission Assessment Subcommittee (TAS)
Request for Quote For CA Single Sign-On Renewal_3-16_JT
Electric Reliability Council of Texas, Inc. (ERCOT) Contract Administration and Procurement Request for Quote For CA Single Sign-On Renewal_3-16_JT Date of Release: March 4, 2016 1 1 GENERAL INFORMATION
Risks and Controls for VAR-001-4 and EOP-004-2. Richard Shiflett Ruchi Ankleshwaria
Risks and Controls for VAR-001-4 and EOP-004-2 Richard Shiflett Ruchi Ankleshwaria 2 Introductions Richard Shiflett Compliance Risk Engineer Joined WECC in February 2014 11 years experience with Bureau
Power System review W I L L I A M V. T O R R E A P R I L 1 0, 2 0 1 3
Power System review W I L L I A M V. T O R R E A P R I L 1 0, 2 0 1 3 Basics of Power systems Network topology Transmission and Distribution Load and Resource Balance Economic Dispatch Steady State System
4.1.1 Generator Owner 4.1.2 Transmission Owner that owns synchronous condenser(s)
A. Introduction 1. Title: Verification and Data Reporting of Generator Real and Reactive Power Capability and Synchronous Condenser Reactive Power Capability 2. Number: MOD-025-2 3. Purpose: To ensure
Generator Interconnection and Deliverability Study Methodology Technical Paper
Generator Interconnection and Deliverability Study Methodology Technical Paper July 2, 2013 Generator Interconnection and Deliverability Study Methodology Table of Contents Introduction... 1 Section One:
SERVICE CLASSIFICATION NO. 14-RA STANDBY SERVICE
Fourth Revised Leaf No. 135 Consolidated Edison Company Superseding Second Revised Leaf No. 135 (Third Revised Leaf No. 135 Canceled) Applicable to Use of Service for SERVICE CLASSIFICATION NO. 14-RA STANDBY
Section 4: Scheduling Philosophy & Tools
Welcome to the Scheduling Philosophy & Tools section of the PJM Manual for Scheduling Operations. In this section you will find the following information: A description of the PJM OI s scheduling philosophy
Transmission Related Station Power Use at Substations
Transmission Related Station Power Use at Substations BUSINESS PRACTICE This Business Practice identifies the cost responsibility for energy consumption at substations by American Transmission Company
CONGESTION MANAGEMENT POLICY
1 (8) CONGESTION MANAGEMENT POLICY Contents 1 General... 2 2 Principles of congestion management... 2 3 Congestion management in the Finnish transmission grid... 3 3.1 Normal situation... 3 3.2 Planned
INTRODUCTION TO HARMONIC ASSESSMENT IN POWER SYSTEMS
INTRODUCTION TO HARMONIC ASSESSMENT IN POWER SYSTEMS LIST OF CONTENT 1. INTRODUCTION... 1 2. HARMONIC VOLTAGE ASSESSMENT REQUIREMENT IN THE UK... 2 3. THE ASSESSMENT... 2 3.1. SYSTEM MODELLING...3 3.2.
REAL TIME DYNAMICS MONITORING SYSTEM (RTDMS ) AND PHASOR GRID DYNAMICS ANALYZER (PGDA) USER TRAINING FOR ERCOT
REAL TIME DYNAMICS MONITORING SYSTEM (RTDMS ) AND PHASOR GRID DYNAMICS ANALYZER (PGDA) USER TRAINING FOR ERCOT SEPTEMBER 16-17, 2014 Electric Power Group. Built upon GRID-3P platform, U.S. Patent 7,233,843,
Northport - Norwalk Harbor Cable (NNC) Tie line
September 9, 008 Northport - Norwalk Harbor Cable (NNC) Tie line Technical Assessment of Operating up to NNC Inter Tie STE Ratings Executive Summary Three (3) 38kV submarine cable circuits (Lines 60, 60,