ATTACHMENT G. Network Operating Agreement
|
|
|
- Myrtle Hoover
- 10 years ago
- Views:
Transcription
1 ATTACHMENT G Network Operating Agreement 1. PURPOSE OF NETWORK OPERATING AGREEMENT The purpose of this Agreement is to identify contractual requirements related to Network Integration Transmission Service over the Transmission Provider s Transmission System. The parties to this agreement (Parties) agree to adhere to Good Utility Practice, including all applicable reliability criteria as observed in the region. This Agreement requires the Parties to recognize that: (1) The Transmission Provider s Transmission System is directly or indirectly interconnected with transmission systems owned or operated by others; (2) The flow of power and energy between such systems shall be controlled by the physical and electrical characteristics of the facilities involved and the manner in which they are operated; and (3) Part of the power and energy being delivered under these Provisions may flow through such other systems rather than through the Transmission Provider facilities. The Parties shall determine methods and take appropriate actions to assure capability for delivery of power and energy at the points of receipt and delivery, and at additional or alternate points of receipt and delivery as established by the Parties. The Parties shall: (1) Operate and maintain equipment 1 necessary for interconnecting the Transmission Customer with the Transmission Provider s Transmission System. (2) Transfer data 2 between their respective control centers as required to maintain reliability of the Transmission System. (3) Use software programs required for data links and constraint dispatching. 1 Necessary equipment includes, but is not limited to, remote terminal units, metering, communications, telemetering and relaying equipment. 2 Data may include, but is not limited to, data pertaining to instantaneous Spinning and Non-Spinning Operating Reserves, heat rates, fuel costs and operational characteristics of Network Resources, generation schedules for Network Resources, interchange schedules, unit outputs for redispatch, voltage schedules, flows of real and reactive power, loss factors, switch status, breaker status, megawatt (MW)/megaVAr flow on lines, bus voltages, transformer taps and other Supervisory Control and Data Acquisition System (SCADA) and real-time data.
2 (4) Exchange data on forecasted loads and resources necessary for planning and operation. (5) Address other technical and operational considerations required for Tariff implementation, including scheduling protocols. 2. TERM This Agreement shall remain effective through the term of the Service Agreement. 3. ADMINISTRATION OF THE PROVISIONS In the event of any irreconcilable differences between the Tariff and this Agreement, the language of the Tariff shall govern. 4. NOTICE Notices or requests made by either Party regarding these provisions shall be made to the representative of the other Party as indicated in the Service Agreement. 5. DEFINITIONS Unless otherwise defined herein, capitalized terms refer to terms defined in the Tariff or in the Rate Schedules. (c) (d) (e) (f) Automatic Generation Control (AGC) The real-time control scheme used by all Balancing Authorities to meet the NERC requirement that Balancing Authorities continually adjust generation, as necessary and within predetermined limits, to meet Balancing Authority load requirements and scheduled interchange commitments and its obligation to support interconnected frequency. Effective Control Action (ECA) An action which results in a specific mitigating response at a location(s) in the power system related to the disturbances of concern, thereby providing acceptable power system performance. Hourly Data Reported Hourly (HDRH) Hourly kilowatt hour (kwh) and kilovar hour (kvarh) data provided to the Transmission Provider at the end of each hour. HDRH is taken from sources such as the interchange kwh system. Hourly Data Reported Monthly (HDRM) Hourly kwh and kvarh data provided at least monthly to the Transmission Provider. HDRM is taken from sources such as the Revenue Metering System. Operating Reserves The sum of Contingency Reserves and Regulating Reserves plus any on-demand obligations plus any reserves required for interruptible imports. Operational Constraints Limitations on the ability of the Transmission System to operate due to any system emergency, loading condition, or maintenance outage on the
3 Transmission Provider facilities, or on facilities of an interconnected utility, that makes it prudent to reduce Transmission System loadings, whether or not all facilities are in service. (g) (h) (i) (j) (k) (l) Remedial Action Schemes (RAS) Sets of fast automatic control actions employed to ensure acceptable power system performance following electrical disturbances as determined by the Transmission Provider power flows and/or stability studies. These may include generator dropping and load tripping. Revenue Metering System (RMS) A data collection system that electronically measures hourly demand and energy quantities for both kilowatt (kw) and kilovars. The Transmission Provider uses this data on a HDRM basis. Single Contingency The loss of a single generator, transmission line, transformer, bus section or DC monopole under any operating condition or anticipated mode of operation. Technical Requirements For Interconnection To The BPA Transmission Grid A document that includes the detailed technical requirements for connecting transmission lines, loads and generation resources into the BPA Grid. The Technical Requirements for the Connection of Transmission Lines and Loads and the Technical Requirements for the Interconnection of Generation Resources are posted on the Transmission Provider s OASIS. Telemetry A data collection system that provides the Transmission Provider with kilowatt information on load, generation and powerflow, on a continuous, instantaneous basis. Transmission Customer Resource Any Transmission Customer-owned resource, regardless of resource location, and any Third Party (consumer or independent power producer) resource directly connected to the Transmission Customer s transmission or distribution system. 6. INTERCONNECTED FACILITY REQUIREMENTS Ownership (1) Equipment or salvageable facilities owned by one Party and installed on the property of the other Party shall remain the property of the owner, except as noted in this Agreement. (2) A Party must identify its facilities installed on the other Party s property. Facilities include all movable equipment and other salvageable facilities which said Party installed on the other Party s property. Ownership of facilities must be made by affixing permanent suitable markers with the owner s
4 name. The Parties shall jointly prepare an itemized list of the aforementioned equipment. (3) Each Party agrees to be responsible for the cost of complying with all applicable Federal, State and local environmental laws for its own facilities, regardless of where the facilities are located. Safety Design The Transmission Provider requires clearance of equipment during maintenance, modification and testing. Facility interconnections between the Transmission Provider and the Transmission Customer are to be designed and constructed to allow clearance of equipment using isolation devices. Isolation devices must produce a visible air gap between the energized facilities and the equipment to be worked on. Operating procedures associated with this interconnection must comply with the Transmission Provider s Accident Prevention Manual and also with the Transmission Customer s safety manual as specified in writing by the Transmission Customer. (c) Access to Interconnected Facilities (1) Each Party agrees to grant permission to the other to enter its property to perform operations and maintenance, meter reading, inspection or removal of the other s equipment and facilities installed on the first Party s property. (2) In providing the above permission, the first Party waives no rights or remedies with respect to any injury, loss or damage resulting from the other s activities on the first Party s property. 7. RESOURCE AND INTERCONNECTION PRINCIPLES AND REQUIREMENTS Remedial Action Schemes (1) The Transmission Customer may be required (at its cost), to provide or assure the provision of it s pro rata share of RAS required to support the transmission capability of the transmission paths the Transmission Customer uses. (2) If the Transmission Customer is required to provide RAS, then the Transmission Provider and the Transmission Customer shall jointly plan and coordinate the implementation of the RAS. No Party shall unduly withhold consent regarding the implementation of the RAS. The Transmission Customer may implement the required RAS where it chooses on its system, as long as the required level of ECA is obtained. The level of reliability of the RAS design on the Transmission Customer s system shall be at least equal to the level of reliability employed in the design of the overall RAS required to support the transmission capability of the transmission path the Transmission Customer uses.
5 (A) (B) (C) The Transmission Customer s contribution to the total operational responsibility for the RAS shall be the ratio of the Transmission Customer s usage of the Transmission Provider s share of the transmission path, to the total rating of the Transmission Provider s share of the transmission path. The Transmission Provider shall provide the appropriate control signals to the Transmission Customer. The Transmission Customer shall provide the necessary equipment to receive and transmit control signals to and from its transmission, generation and control center facilities to arm and initiate the appropriate ECA or actions determined by the Transmission Provider. (3) Additional information regarding RAS can be found in the Technical Requirements For Interconnection To The BPA Transmission Grid. Operation of Resources (1) The Transmission Customer shall operate its generation resources that interconnect with the Transmission Provider s Transmission System or which are located in the Transmission Provider s Balancing Authority in a manner consistent with Good Utility Practice, and the standards, criteria and requirements of NERC, WECC, NWPP, the Transmission Provider and any applicable reliability authority. (2) The Transmission Customer shall pay the cost of necessary communications installations, and modification of the Transmission Provider s computer hardware and software, including accommodating the Transmission Customer's decisions to change Balancing Authorities. (3) Any resources used by the Transmission Customer to meet its Operating Reserve obligations to the Transmission Provider s Balancing Authority shall meet the same NERC, WECC, NWPP and other applicable requirements, practices and procedures as the Transmission Provider s generating resources providing these same services including, AGC capability, reserve availability, ramp rate, governor response, random testing and a monthly startup test. (c) Interconnection with Third Parties (1) Each Party shall cooperate with other interconnected systems in establishing arrangements or mitigation measures to minimize operational impacts on the other Party s system. (2) Each Party recognizes that a Party s proposed new interconnection or modification of an existing interconnection between its system and the system of a Third Party, may cause adverse effects on the system of the other Party. The
6 Party making such interconnection or modification shall minimize or otherwise compensate for adverse operational impacts to the other Party s system. (d) Interconnection with the Transmission Provider The Transmission Customer shall plan, construct, operate and maintain its facilities and system that interconnect with the Transmission Provider s Transmission System in accordance with Good Utility Practice, including, but not limited to, all applicable guidelines of NERC, WECC and NWPP, the Transmission Provider and any applicable reliability authority, and generally accepted regional practices. Additional information regarding Interconnection Requirements can be found in the Technical Requirements For Interconnection To The BPA Transmission Grid. (e) Generation Integration (1) Resources connected directly to the Transmission Provider s Transmission System or which are in the Transmission Provider s Balancing Authority are subject to compliance with the Transmission Provider s generation integration requirements, Good Utility Practice and all applicable standards of NERC, WECC, NWPP, the Transmission Provider and any applicable reliability authority, and any generally accepted regional practices that are adopted by the Transmission Provider. All resources integrated into a Transmission Customer s system which, by virtue of their point of interconnection, are capable of energizing the Transmission Provider s facilities, must comply with safety requirements of the above standards, including those for relay protection, insulation coordination, switchgear and safety. This requirement typically applies to generators that are integrated into a system that is connected radially from a tapped Transmission Provider transmission line or Transmission Provider substation. With respect to other resources integrated into a Transmission Customer s network, all points of interconnection between the Transmission Provider and the Transmission Customer must be operated and maintained in a manner consistent with Good Utility Practice. (2) The Transmission Customer agrees to notify the Transmission Provider a minimum of eighteen (18) months prior to energization of a resource if such resource is expected to impact the Transmission Provider s Transmission System. (f) The Transmission Provider has the right to revise the Technical Requirements for Interconnection to the BPA Transmission Grid as it deems necessary or appropriate. Upon request, the Transmission Provider shall provide to the Transmission Customer a copy of the Technical Requirements, including any revisions thereto.
7 8. CUSTOMER INFORMATION REQUIREMENT The Transmission Customer shall provide to the Transmission Provider load forecasts, generation forecasts, schedules and any other information necessary to implement Curtailment, Load Shedding and congestion management procedures, and for ATC computations when requested by the Transmission Provider. 9. POWER QUALITY Requirements and information regarding Power Quality can be found in the Technical Requirements For Interconnection To The BPA Transmission Grid. 10. SERVICE INTERRUPTIONS Temporary Load Shifts and Maintenance Notification (1) The Parties may temporarily curtail, reduce or shift deliveries of electric power if any such Party determines that such Curtailment, reduction or load shift is necessary or desirable in case of system emergencies or operational constraints on the system of either Party, or to install equipment in, make repairs to, make replacement within, conduct investigations and inspections of, or perform other maintenance work on the Parties facilities. To the extent reasonable or appropriate, the Parties shall use temporary facilities or equipment to minimize the effect of any such interruption, reduction or load shift. (2) The Transmission Customer must submit a report concerning any such curtailment, reduction or load shift on its transmission system to the Transmission Provider within four (4) days of such curtailment, reduction or load shift. Reports may be made by telephone, mail or other electronic processes. The point of contact for each Party shall be designated pursuant to the Service Agreement. On receipt of the Transmission Customer s report, the Transmission Provider shall adjust the Transmission Customer s billing determinants pursuant to the Transmission Provider s billing procedures. If the Transmission Customer does not submit the report within four (4) days of the curtailment, reduction or load shift, the Transmission Provider shall assess charges based on available data. Additional information regarding Service Interruptions can be found in the Technical Requirements For Interconnection To The BPA Transmission Grid. See paragraph 5(j) above. 11. EMERGENCY PLANNING AND OPERATION The Transmission Provider shall be responsible for planning, coordinating and implementing emergency operation schemes. Examples of such schemes include the NWPP under- frequency Load Shedding program, the under- voltage Load Shedding program and the system restoration plan. There may be additional schemes that meet the NWPP, WECC and applicable reliability authority planning objectives. If the Transmission Provider identifies reliability objectives
8 beyond the NWPP, WCC and applicable reliability authorityobjectives, they shall be communicated to the Transmission Customer(s). The need to identify additional objectives may involve anticipated reduction in system restoration time following blackout or brownout emergencies. The Transmission Customer shall: (1) participate in the development and implementation of Load Shedding programs for system security; (2) install and maintain the required Load Shedding relays, including underfrequency and under-voltage relays; and (3) participate in system restoration planning. Disputes with any of the requirements specified by the Transmission Provider shall be resolved through the dispute resolution process described in the Tariff. Additional information regarding Emergency Planning and Operation can be found in the Technical Requirements For Interconnection To The BPA Transmission Grid. 12. INFORMATION AND METERING REQUIREMENTS Requirements and information regarding Information and Metering Requirements can be found in the Technical Requirements For Interconnection To The BPA Transmission Grid. 13. METERING COSTS Metering of Existing Facilities The Transmission Provider shall be responsible for costs of all Transmission Providerrequired new meter installation or meter replacements at a Transmission Customer facility existing on the Effective Date of this Service Agreement. The Transmission Customer shall be responsible for the costs of: (1) Any meter replacement or new installation at points of delivery which are not required to achieve the best overall plan of service (convenience points of delivery); and (2) Any meters needed because the Transmission Customer changes Balancing Authorities or is displacing transmission from the Transmission Provider; and/or meters requested by the Transmission Customers. Metering of New Transmission Customer Facilities The Transmission Provider shall be responsible for costs associated with installation of the Transmission Provider-approved metering at new facilities established after the Effective Date of this Service Agreement that are connected to the Transmission Provider s Transmission System.
9 The Transmission Customer shall be responsible for the costs of the Transmission Provider approved metering for: (1) all points of generation (resource) integration; (2) all AGC interchange points; and (3) all other points of electrical interconnection, including convenience points of delivery. 14. COMMUNICATIONS Requirements and information regarding Communications can be found in the Technical Requirements For Interconnection To The BPA Transmission Grid.
Reclamation Manual Directives and Standards
Subject: Purpose: Ancillary Generation Services Establishes standards for ancillary generation services. Authority: The Reclamation Act of 1902 (Act of June 17, 1902, 32 Stat. 388), the Town Sites and
SCHEDULE 1. Scheduling, System Control and Dispatch Service
Seventh Revised Volume No. 5 (MT) Original Sheet No. 71 SCHEDULE 1 Scheduling, System Control and Dispatch Service This service is required to schedule the movement of power through, out of, within, or
Load Dispatcher (Class Code 5223) Task List
A. Load Dispatching, General Load Dispatcher (Class Code 5223) Task List 1. Prior to work shift speaks to Load Dispatcher(s), reviews hardcopy and computer logs, and looks at the dispatcher's diagram board
Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering
Title 20 PUBLIC SERVICE COMMISSION Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES Chapter 02 Engineering Authority: Public Utility Companies Article, 2-121, 5-101 and 5-303, Annotated Code of Maryland.
Table of Contents. Real-Time Reliability Must Run Unit Commitment and Dispatch (Formerly G-203) Operating Procedure
No. 2310 Table of Contents Purpose... 2 1. Responsibilities... 2 2. Scope/Applicability... 2 2.1 Background... 2 2.2 Scope / Applicability... 2 3. Detail... 3 3.1 Energy Dispatching... 3 3.1.2 Real-Time
Unitil Energy Systems, Inc. Interconnection Standards For Inverters Sized Up To 100 kva
Unitil Energy Systems, Inc. Interconnection Standards For Inverters Sized Up To 100 kva Issued: August 2009 SIZED UP TO 100 KVA TABLE OF CONTENTS 1.0 Introduction... 1 1.1 Applicability... 1 1.2 Definitions...
Economic Dispatch: Concepts, Practices and Issues
Economic Dispatch: Concepts, Practices and Issues Presentation to the Joint Board for the Study of Economic Dispatch FERC Staff Palm Springs, California November 13, 2005 2 Overview What is economic dispatch?
THE CONNECTICUT LIGHT AND POWER COMPANY TERMS AND CONDITIONS FOR ELECTRIC SUPPLIERS PAGE 1 OF 18
TERMS AND CONDITIONS FOR ELECTRIC SUPPLIERS PAGE 1 OF 18 1. Applicability 1A. The following Terms and Conditions shall apply to every registered Electric Supplier authorized to do business within Connecticut
THE CONNECTICUT LIGHT AND POWER COMPANY, DBA EVERSOURCE ENERGY TERMS AND CONDITIONS FOR ELECTRIC SUPPLIERS PAGE 1 OF 20
TERMS AND CONDITIONS FOR ELECTRIC SUPPLIERS PAGE 1 OF 20 1. Applicability 1A. The following Terms and Conditions shall apply to every registered Electric Supplier authorized to do business within Connecticut
Midwest Reliability Organization Procedure For NERC PRC-012
Midwest Reliability Organization Procedure For NERC PRC-012 A. Introduction The following procedure developed by the MRO Protective Relay Subcommittee (PRS) and Transmission Assessment Subcommittee (TAS)
ENTSO-E Network Code on Emergency and Restoration
ENTSO-E Network Code on Emergency and Restoration Notice 25 March 2015 This Network Code represents ENTSO-E s final proposals in line with the ACER Framework Guidelines on Electricity System Operation
When this standard has received ballot approval, the text boxes will be moved to the Guidelines and Technical Basis section of the Standard.
CIP-002-5 Cyber Security BES Cyber System Categorization When this standard has received ballot approval, the text boxes will be moved to the Guidelines and Technical Basis section of the Standard. A.
Rules on Southern Companies Energy Auction Participation
Southern Company Services, Inc. First Revised Sheet No. 20B Superseding Original Sheet No. 20B Rules on Southern Companies Energy Auction Participation 1.0 Participation; Definitions 1.1 Southern Companies
THE NARRAGANSETT ELECTRIC COMPANY Terms and Conditions for Nonregulated Power Producers
Sheet 1 THE NARRAGANSETT ELECTRIC COMPANY Terms and Conditions for Nonregulated Power Producers The delivery of electricity shall be in accordance with the provisions of law, regulation and these Terms
GENERATING FACILITY INTERCONNECTION AGREEMENT (3 RD PARTY INADVERTENT-EXPORTING) FORM 14-743
Southern California Edison Revised Cal. PUC Sheet No. 50718-E Rosemead, California (U 338-E) Cancelling Original Cal. PUC Sheet No. 31122-E Sheet 1 GENERATING FACILITY INTERCONNECTION AGREEMENT (3 RD PARTY
CURTAILABLE RATE PROGRAM FOR INDIVIDUAL CUSTOMER LOADS
Page 1 of 16 CURTAILABLE RATE PROGRAM FOR INDIVIDUAL CUSTOMER LOADS PROPOSED TERMS AND CONDITIONS January 2015 Page 2 of 16 TABLE OF CONTENTS 1. Definitions... 3 2. Curtailable Load Options... 6 3. Nomination
TERMS AND CONDITIONS
Virginia Electric and Power Company TERMS AND CONDITIONS XXIV. GENERATOR INTERCONNECTION STANDARD Electric generator interconnection service includes only the ability to interconnect an electric generator
N.J.A.C. 14:8-4 NET METERING FOR CLASS I RENEWABLE ENERGY SYSTEMS
N.J.A.C. 14:8-4 NET METERING FOR CLASS I RENEWABLE ENERGY SYSTEMS 14:8-4.1 Scope This subchapter sets forth net metering requirements that apply to electric power suppliers, basic generation service providers
FRCC Standards Handbook. FRCC Automatic Underfrequency Load Shedding Program. Revision Date: July 2003
F R C C FRCC Standards Handbook FRCC Automatic Underfrequency Load Shedding Program Revision Date: July 2003 FRCC Underfrequency Load Shedding Program Modification and Approval Process Requests to modify
General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System
General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System Direction Planification des actifs et expertise de transport February 2011 TABLE OF CONTENTS 1. CONDUCTING
Portland General Electric Company P.U.C. Oregon No. E-18 Original Sheet No. C-1 RULE C CONDITIONS GOVERNING CUSTOMER ATTACHMENT TO FACILITIES
P.U.C. Oregon No. E-18 Original Sheet No. C-1 RULE C CONDITIONS GOVERNING CUSTOMER ATTACHMENT TO FACILITIES 1. Acceptance of Electricity Service By establishing or requesting a POD or by continuing an
ENTSO-E Network Code on Emergency and Restoration
ENTSO-E Network Code on Emergency and Restoration 25 March 2015 Notice This Network Code represents ENTSO-E s final proposals in line with the ACER Framework Guidelines on Electricity System Operation
CONTRACT FOR THE SALE AND PURCHASE OF ELECTRICITY GENERATED BY WIND POWER
CONTRACT FOR THE SALE AND PURCHASE OF ELECTRICITY GENERATED BY WIND POWER ASSISTANCE TO ENERGY SECTOR TO STRENGTHEN ENERGY SECURITY AND REGIONAL INTEGRATION CONTRACT NUMBER EPP-I-08-03-00008-00 AUGUST,
IESO Supply Deliverability Guidelines
PUBLIC IMO_GDL_0021 IESO Supply Deliverability Guidelines Issue 3.0 This document is to be used to evaluate long-term system adequacy and connection assessments Public Disclaimer The posting of documents
Agenda do Mini-Curso. Sérgio Yoshio Fujii. Ethan Boardman. [email protected]. [email protected]
Agenda do Mini-Curso Sérgio Yoshio Fujii [email protected] Ethan Boardman [email protected] Agenda do Mini-Curso Sistemas de Distribuição (DMS) Characteristics of Distribution Network
Net Energy Metering Southern California Edison
NET ENERGY METERING To encourage small electrical customers to install environmentally friendly sources of electrical power, the State of California has passed laws to make the process of interconnecting
Ancillary Services and Flexible Generation
Ancillary Services and Flexible Generation Contents Ancillary Services Overview Types of Ancillary Services Market Impact Benefits of Medium Speed Solution Contact Information What are Ancillary Services?
Transmission Function Employees Job Titles and Descriptions 18 C.F.R 358.7(f)(1)
Date of Last Change to the Provided Information August 27 th, 2015 Director, Transmission Operations The employee in this position is responsible for effectively managing the operation of FirstEnergy Utilities
Piedmont Natural Gas Company, Inc. Tennessee Index of Tariff & Service Regulations
Tennessee Index of Tariff & Service Regulations Rate Schedule 301 Rate Schedule 302 Rate Schedule 303 Rate Schedule 304 Rate Schedule 306 Rate Schedule 307 Rate Schedule 309 Rate Schedule 310 Rate Schedule
ALCOA POWER GENERATING INC. Long Sault Division. Open Access Transmission Tariff
Alcoa Power Generating Inc. Long Sault Division ALCOA POWER GENERATING INC. Long Sault Division Open Access Transmission Tariff The following sheets reflect all revisions submitted to the Federal Energy
Electric Operations Manager
CITY OF ANAHEIM invites applications for the position of: Electric Operations Manager SALARY: $10,602.75 - $14,578.75 Monthly $127,233.00 - $174,945.00 Annually OPENING DATE: 04/07/16 CLOSING DATE: Continuous
SCADA. The Heart of an Energy Management System. Presented by: Doug Van Slyke SCADA Specialist
SCADA The Heart of an Energy Management System Presented by: Doug Van Slyke SCADA Specialist What is SCADA/EMS? SCADA: Supervisory Control and Data Acquisition Retrieves data and alarms from remote sites
San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions August 10, 2015. Electric Grid Operations
San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions August 10, 2015 Electric Grid Operations Director Electric Grid Operations: Responsible for overall transmission
Scope of Restoration Plan
RWG Area Restoration Review Worksheet (10/28/09) EOP-006-02 Directory 8 EOP-005 NYSRG Rule G Text Restoration Plan Requirement R1.Each Reliability Coordinator shall have a Reliability Coordinator Area
Residential Solar Service Agreement (RSSA) Customer Sited Solar Photovoltaic Systems
Residential Solar Service Agreement (RSSA) Customer Sited Solar Photovoltaic Systems This Agreement is made and entered into this day of, 20, ( Effective Date ) by and between the Orlando Utilities Commission
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
AGREEMENT FOR INTERCONNECTION AND PARALLEL OPERATION OF DISTRIBUTED GENERATION
AGREEMENT FOR INTERCONNECTION AND PARALLEL OPERATION OF DISTRIBUTED GENERATION This Interconnection Agreement ( Agreement ) is made and entered into this day of,, by Sharyland Utilities, L.P. McAllen (
EssPro Energy Storage Grid Substation The power to control energy
EssPro Energy Storage Grid Substation The power to control energy EssPro Grid gives you the power to control energy helping to keep smart grids in balance Maximizing the value and performance of energy
Carolina Power & Light Company 51 d/b/a Progress Energy Carolinas, Inc. SERVICE REGULATIONS
Carolina Power & Light Company 51 d/b/a Progress Energy Carolinas, Inc. 1. SERVICE AGREEMENT SERVICE REGULATIONS (d) (e) (f) Description: The Service Agreement (hereinafter sometimes termed "Agreement")
INDEPENDENCE POWER & LIGHT DEPARTMENT Independence, Missouri. Schedule NM-1 Customer-Generator Net Metering Contract Service Rider
AVAILABLE Electric Service is available under this schedule in the entire area served by the Department s existing secondary and primary voltage distribution systems. APPLICABLE To any customer normally
San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions June 4, 2015. Electric Grid Operations
San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions June 4, 2015 Electric Grid Operations Director Electric Grid Operations: Responsible for overall transmission
FIXED CHARGE: This is a cost that goes towards making the service available, including
ELECTRICITY BILL COMPONENTS FIXED CHARGE: This is a cost that goes towards making the service available, including installation and maintenance of poles, power lines and equipment, and 24-hour customer
RIG Acceptance Test (RAT) Procedures
RIG Acceptance Test (RAT) Procedures RIG Acceptance Test (RAT) Procedure 0 Print Date 2 /20/2007 REVISION HISTORY REVISON NO. DATE DESCRIPTION 1.0 Initial Release 0 Update Logo and Links i RIG Acceptance
AUSTIN UTILITIES. CHARACTER OF SERVICE: AC, 60 cycles, 120/240 Volt, three wire, single-phase; or 120 Volt, two wire.
AVAILABLE: Within established City Limits. AUSTIN UTILITIES Schedule (110) Issued 11/12/13 Supersedes (110) Issued 11/13/12 Sheet No. 1 of 1 RESIDENTIAL SERVICE APPLICABLE: To single-family residences
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks Introduction SCADA (Supervisory Controlled and Data Acquisition) controlled multi-step metalenclosed automatic capacitor
Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.
Generation Interconnection System Impact Study Report For PJM Generation Interconnection Request Queue Position X1-114 Sandyston January 2012 Preface The intent of the System Impact Study is to determine
To complete the process for a net metering interconnection, please follow the steps below:
We appreciate your interest in Pacific Power s net metering program. Before purchasing any net metering equipment, we recommend you review the requirements for interconnecting a net metering system to
White Paper. Convergence of Information and Operation Technologies (IT & OT) to Build a Successful Smart Grid
White Paper Convergence of Information and Operation Technologies (IT & OT) to Build a Successful Smart Grid Contents Executive Summary... 3 Integration of IT and OT... 4 Smarter Grid using Integrated
References... 4. Appendices... 5. I. INTRODUCTION... 6 A. Background... 6 B. Standards... 6
ISO New England Operating Procedure No. 14 - Technical Requirements for Generators, Demand Resources, Asset Related Demands and Alternative Technology Regulation Resources Effective Date: January 29, 2015
ENTSO-E Working Draft Network Code on Emergency and Restoration
ENTSO-E Working Draft Network Code on Emergency and Restoration DRAFT FOR THE FOURTH PUBLIC WORKSHOP Notice 22 January 2015 This document reflects the status of the work of Transmission System Operator
METERING CODE. Energy Market Authority of Singapore
METERING CODE Energy Market Authority of Singapore TABLE OF CONTENTS 1 GENERAL AND ADMINISTRATIVE PROVISIONS...1 1.1 Purpose of this Code...1 1.2 To Whom this Code Applies...1 1.3 Prohibition...1 1.4 Definitions...1
GENe Software Suite. GENe-at-a-glance. GE Energy Digital Energy
GE Energy Digital Energy GENe Software Suite Today s utilities have complex requirements that need sophisticated solutions. GE Energy s GENe provides these solutions. Using the latest advances in technology,
New Brunswick Electricity Business Rules
New Brunswick Electricity Business Rules Table of Contents Chapter 1 Chapter 2 Chapter 3 Chapter 4 Administration and Participation Transmission Planning and Connections Reliable Operations Billing and
NPCC Regional Reliability Reference Directory # 8 System Restoration
NPCC Regional Reliability Reference Directory # 8 Task Force on Coordination of Operations Revision Review Record: October 21, 2008 Adopted by the Members of the Northeast Power Coordinating Council, Inc.
PROVO CITY UTILITIES NET METERING LICENSE AGREEMENT
PROVO CITY UTILITIES NET METERING LICENSE AGREEMENT Customer-Owned Electric Generating Systems of 25kW or Less This NET METERING LICENSE AGREEMENT ( Agreement ) is between ( Customer ) and Provo City -
SOUTH CAROLINA. Standard for Interconnecting Small Generation 100 kw or Less with Electric Power Systems (EPS) (Interconnection Standard)
SOUTH CAROLINA Standard for Interconnecting Small Generation 100 kw or Less with Electric Power Systems (EPS) (Interconnection Standard) 1. Overview: This Standard contains the requirements, in addition
Kiwi Energy NY LLC 144 North 7 th Street #417 Brooklyn, NY 11249 1-877- 208-7636 www.kiwienergy.us
Kiwi Energy NY LLC 144 North 7 th Street #417 Brooklyn, NY 11249 1-877- 208-7636 www.kiwienergy.us Natural Gas / Electricity SALES AGREEMENT Customer Disclosure Statement Page 1 Price: Variable rate per
Energy Management Systems (EMS)
Energy Management Systems (EMS) Introduction Abstract This talk deals with the role of an Energy Management System (EMS) in the overall Smart Grid. Why an EMS is needed will be discussed and its importance
ONCOR ELECTRIC DELIVERY COMPANY LLC TARIFF FOR TRANSMISSION SERVICE TO, FROM AND OVER CERTAIN INTERCONNECTIONS REVISION NO. 13
ONCOR ELECTRIC DELIVERY COMPANY LLC TARIFF FOR TRANSMISSION SERVICE TO, FROM AND OVER CERTAIN INTERCONNECTIONS REVISION NO. 13 Sheet No. CONTENTS 1.0 Utility Operations... 5 1.1 Authority... 5 2.0 Wholesale
GLOSSARY. Glossary of Terms for Capacity Based Demand Response PUBLIC. Issue 3.0 GOT-1
PUBLIC GOT-1 GLOSSARY Glossary of Terms for Capacity Based Demand Response Issue 3.0 This document provides a glossary of terms with definitions used in the Capacity Based Demand Response program. Public
OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:
Filed: September 0, 00 EB-00-0 Tab Schedule Page of OPERATIONS CAPITAL.0 INTRODUCTION Operations Capital funds enhancements and replacements to the facilities required to operate the Hydro One Transmission
SMALL GENERATOR INTERCONNECTION AGREEMENT (SGIA) (For Generating Facilities No Larger Than 20 MW)
SMALL GENERATOR INTERCONNECTION AGREEMENT (SGIA) (For Generating Facilities No Larger Than 20 MW) TABLE OF CONTENTS Page No. Article 1. Scope and Limitations of Agreement.... - 1-1.1 Applicability... -
TRANSMISSION OPERATIONS (August 5, 2010)
TRANSMISSION OPERATIONS (August 5, 2010) Managing Director Transmission Operations: Paul B. Johnson The Managing Director - Transmission Operations is responsible for the safe, reliable, costeffective,
Last revised: September 1, 2014 TRANSMISSION FUNCTION TITLES AND JOB DESCRIPTIONS
Last revised: September 1, 2014 TRANSMISSION FUNCTION TITLES AND JOB DESCRIPTIONS EVP, Chief Operations Officer, has primary responsibility for the overall planning, operations and control of the transmission
Agreement for Net Metering and Interconnection Services (Level 1, 2 and 3 Interconnection)
Agreement for Net Metering and Interconnection Services (Level 1, 2 and 3 Interconnection) This Agreement for Net Metering and Interconnection Services ( Agreement ) is made and entered into this day of
Administrative Services for the PJM Interconnection Operating Agreement
PJM Manual 33: Administrative Services for the PJM Interconnection Operating Agreement Revision: 12 Effective Date: March 31, 2016 Prepared by Member Relations PJM 2016 PAGE iii lviii PJM 2008 Revision
Colorado Springs Utilities Interconnection Guidelines For Transmission to Transmission Interconnections Version 1 12/04/2007
Colorado Springs Utilities Interconnection Guidelines For Transmission to Transmission Interconnections Version 1 12/04/2007 I.INTRODUCTION AND GENERAL POLICY 5 A. INTRODUCTION...5 B. THE COLORADO SPRINGS
Smart Energy Consumption and the Smart Grid
Smart Energy Consumption and the Smart Grid Executive Summary The nation s outdated electrical infrastructure is being transformed. Fundamental changes that add intelligence, integrated communications
System Operator Certification Program Administrative Guidelines
System Operator Certification Program Send your comments to [email protected] by September 24, 2004 Maintaining NERC System Operator Credential Through the Use of Continuing Education Credit Hours North
ADMS(Advanced Distribution Management System ) in Smart Grid
ADMS(Advanced Distribution Management System ) in Smart Grid 柯 佾 寬 博 士 Yi-Kuan Ke, Ph.D. 2014/03/28 Smart Grid Solution Smart Grid Solution Overview Smart Grid Solutions Smart Network Operation - Distribution
PEND OREILLE COUNTY PUD. Quality Service at Low Cost RATES FOR ELECTRIC SERVICE
PEND OREILLE COUNTY PUD Quality Service at Low Cost RATES FOR ELECTRIC SERVICE Effective July 1, 2015 Contents What Is a Public Utility District... 2 Services Offered By The District... 3 Residential Service...
NORTH CAROLINA INTERCONNECTION PROCEDURES, FORMS, AND AGREEMENTS. For State-Jurisdictional Generator Interconnections. Effective June 16, 2009
Carolina Power & Light Company 63 d/b/a Progress Energy Carolinas, Inc. (North Carolina Only) NORTH CAROLINA INTERCONNECTION PROCEDURES, FORMS, AND AGREEMENTS For State-Jurisdictional Generator Interconnections
ELECTRIC EPB OF CHATTANOOGA Chattanooga, Tennessee SCHEDULE OF RULES AND REGULATIONS
ELECTRIC EPB OF CHATTANOOGA Chattanooga, Tennessee SCHEDULE OF RULES AND REGULATIONS NOTE: EPB shall mean THE ELECTRIC POWER BOARD OF CHATTANOOGA whose main office is located in Chattanooga, Tennessee.
Post Operational Readiness. Operational Services and Performance
Post Operational Readiness Confirmation i Post Operations Certificate 19 th November 2012 Dave Carroll Operational Services and Performance EirGrid Overview Process Pre-Requisites 1. Performance Monitoring
Guidelines for Large Photovoltaic System Integration
1 Guidelines for Large Photovoltaic System Integration Silviu Darie, PhD(EE), PE(EE) Abstract- The paper summarizes the result of a research project funded by the Department of Energy (DOE) in collaboration
SPECIFICATION COG-2007
Cleco Power LLC SPECIFICATION COG-2007 FOR PARALLEL OPPERATION OF CUSTOMER-OWNED GENERATION ON CLECO S ELECTRICAL SYSTEM Revised: March 7, 2014 CONTENTS ITEM NO. TITLE PAGE NO. 1.0 Scope 3 2.0 Policy On
ENGINEERING COMPETENCIES ENTRY LEVEL ENGINEER. Occupation Specific Technical Requirements
ENGINEERING COMPETENCIES ENTRY LEVEL ENGINEER Responsible for performing entry level engineering analysis, design, plan, review and inspection for small to medium projects and/or designated segments of
sink asset load power pool ISO pool participant bids operating constraints ancillary service declarations
G1 DEFINITIONS In the ISO rules: acceptable operational reason means with respect to a source asset, any one or more of the following: i) a circumstance related to the operation of the generating asset
STATEMENT OF CHARGING METHODOLOGY FOR USE OF ELECTRICITY NORTH WEST LIMITED S ELECTRICITY DISTRIBUTION NETWORK
STATEMENT OF CHARGING METHODOLOGY FOR USE OF ELECTRICITY NORTH WEST LIMITED S ELECTRICITY DISTRIBUTION NETWORK This statement is effective from 1 April 2010 This statement is approved by the Gas and Electricity
Study to Determine the Limit of Integrating Intermittent Renewable (wind and solar) Resources onto Pakistan's National Grid
Pakistan Study to Determine the Limit of Integrating Intermittent Renewable (wind and solar) Resources onto Pakistan's National Grid Final Report: Executive Summary - November 2015 for USAID Energy Policy
CONSTELLATION ENERGY TERMS AND CONDITIONS
CONSTELLATION ENERGY TERMS AND CONDITIONS Purchase of Electric Generation Service. Constellation NewEnergy, Inc. ( Constellation ) agrees to sell, and you agree to buy, your full requirements for residential
Commercial and Industrial Electric Rates
Commercial and Industrial Electric Rates INTERIM DAKOTA ELECTRIC ASSOCIATION SECTION: V 4300 220 th Street West SHEET: 4 Farmington, MN 55024 REVISION: 16 SCHEDULE 36 IRRIGATION SERVICE Availability Available
NORTH LITTLE ROCK ELECTRIC DEPARTMENT NET METERING RULES
NORTH LITTLE ROCK ELECTRIC DEPARTMENT NET METERING RULES TABLE OF CONTENTS DEFINITIONS... D-1 SECTION 1. GENERAL PROVISIONS 1.01. Purpose... 1-1 1.02. Other Provisions... 1-1 SECTION 2. NET METERING REQUIREMENTS
TERMS AND CONDITIONS
XXV. NET METERING A. Applicability and Availability 1. The terms Net Metering Service, Net Metering Customer, Agricultural Net Metering Customer, Agricultural Business, Customer, Person(s), Time-of-Use
Demand Response FAQs
1 Under the current CAISO tariff, assuming it would otherwise meet the requirements under the CAISO tariff and business practice manuals to do so, can the Load associated with a retail meter participate